• 제목/요약/키워드: All-ceramic materials

검색결과 513건 처리시간 0.023초

All-ceramic versus titanium-based implant supported restorations: Preliminary 12-months results from a randomized controlled trial

  • Weigl, Paul;Trimpou, Georgia;Grizas, Eleftherios;Hess, Pablo;Nentwig, Georg-Hubertus;Lauer, Hans-Christoph;Lorenz, Jonas
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권1호
    • /
    • pp.48-54
    • /
    • 2019
  • PURPOSE. The aim of the present randomized controlled study was to compare prefabricated all-ceramic, anatomically shaped healing abutments followed by all-ceramic abutments and all-ceramic crowns and prefabricated standard-shaped (round-diameter) titanium healing abutments followed by final titanium abutments restored with porcelain-fused-to-metal (PFM) implant crowns in the premolar and molar regions. MATERIALS AND METHODS. Forty-two patients received single implants restored either by all-ceramic restorations (test group, healing abutment, final abutment, and crown all made of zirconia) or conventional titanium-based restorations. Immediately after prosthetic incorporation and after 12 months of loading, implant survival, technical complications, bone loss, sulcus fluid flow rate (SFFR) as well as plaque index (PI) and implant stability (Periotest) were analyzed clinically and radiologically. RESULTS. After 12 months of loading, an implant and prosthetic survival rate of 100% was observed. Minor prosthetic complications such as chipping of ceramic veneering occurred in both groups. No statistical significant differences were observed between both groups with only a minimum of bone loss, SFFR, and PI. CONCLUSION. All-ceramic implant prostheses including a prefabricated anatomically shaped healing abutment achieved comparable results to titanium-based restorations in the posterior region. However, observational results indicate a benefit as shaping the peri-implant soft-tissue with successive provisional devices and subsequent compression of the soft tissue can be avoided.

Survival rate of modern all-ceramic FPDs during an observation period from 2011 to 2016

  • Pott, Philipp-Cornelius;Eisenburger, Michael;Stiesch, Meike
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권1호
    • /
    • pp.18-24
    • /
    • 2018
  • PURPOSE. In literature, many studies compare survival rates of different types of FPDs. Most of them compared restorations, which originated from one university, but from different clinicians. Data about restoration survival rates by only one experienced dentist are very rare. The aim of this study was to evaluate the survival rate of all-ceramic FPDs without the blurring effects of different clinicians. MATERIALS AND METHODS. 153 veneered-zirconia FPDs were observed for follow-up. 22 patients received 131 single crowns and 22 bridges. Because of the different bridge lengths, one unit was defined as a restored or replaced tooth. In total, 201 units were included. Only the restorations performed by the same clinician and produced in the same dental laboratory from 2011 to 2016 were included. Considered factors were defined as "type of unit", "type of abutment", "intraoral region", and "vitality". Modified UHPHS criteria were used for evaluation. Statistical analysis was performed using cox-regression. RESULTS. 189 units (94.0%) showed no kind of failure. 5 chippings (2.4%) could be corrected by intraoral polishing. 4 units (1.9%) exhibited spontaneous decementation. These polishable and recementable restorations are still in clinical use. Chippings or decementations, which lead to total failure, did not occur. One unit was completely fractured (0.5 %). Biological failures (caries, periodontitis or periimplantitis) did not occur. The statistical analysis of the factors did not reveal any significant differences. CONCLUSION. Modern all-ceramic FPDs seem to be an appropriate therapy not only for single restorations but for complex occlusal rehabilitations.

전부도재관의 변연 적합도 비교평가 (Comparative study in marginal accuracy of several all ceramic crowns)

  • 김정미;정수하
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.87-92
    • /
    • 2008
  • Purpose: In this study, we tried to compare marginal accuracy when produce ceramic crown using all ceramic materials and existent metal-ceramic system. Material and methods: All-ceramic systems were E-max (Ivoclar/Vivadent, Lichtenstein), Lava(3M, U.S.A.) and Wol-ceram(Teamziereis, Germany). Metal-ceramic system(PFG) was composed of Au-Pt alloy (Metalor, Switzerlandand) and overlying ceramic(D-sign, Ivoclar/Vivadent, Lichtenstein). We fabricated metal master die with upper diameter of 7.95mm, bottom diameter of 9.00mm, height of 5.00mm, and taper of $6^{\circ}$. All ceramic system used 0.5mm thickness ceramic coping, while metalceramic system used 0.3 thickness metal coping. By adding dentin and enamel ceramics on each coping, a crown with a proximal thickness of 1.0 mm and occlusal thickness of 2.0mm was fabricated. Pressure of 2kg was applied for 10 seconds on each crown with static load compressor. Before and after cementation, we measured the marginal gap at 4 points of each crown using optical microscope. The data was analyzed using a Student's t test and repeated-measures of analyses of variance(ANOVA) followed by a Bonferroni test. A p value<0.05 was considered significant. Results: As experiment results, marginal accuracy of wol-ceram and Lava is no good when compared with marginal accuracy of PFG. But marginal accuracy of E.max is good when compared with PFG. This result showed not significant. The marginal accuracy of E.max is good when compared with marginal accuracy of wol-ceram and Lava. Conclusion: The marginal accuracy of E.max is very good when compared with marginal accuracy of another group.

  • PDF

Spark Plasma Sintering 법으로 제조한 CoSb3 Skutterudite계 열전소재의 n형 첨가제 효과 (Effect of n-type Dopants on CoSb3 Skutterudite Thermoelectrics Sintered by Spark Plasma Sintering)

  • 이재기;최순목;이홍림;서원선
    • 한국재료학회지
    • /
    • 제20권6호
    • /
    • pp.326-330
    • /
    • 2010
  • $CoSb_3$ Skutterudites materials have high potential for thermoelectric application at mid-temperature range because of their superior thermoelectric properties via control of charge carrier density and substitution of foreign atoms. Improvement of thermoelectric properties is expected for the ternary solid solution developed by substitution of foreign atoms having different valances into the $CoSb_3$ matrix. In this study, ternary solid solutions with a stoichiometry of $Co_{1-x}Ni_xSb_3$ x = 0.01, 0.05, 0.1, 0.2, $CoSb_{3-y}Te_y$, y = 0.1, 0.2, 0.3 were prepared by the Spark Plasma Sintering (SPS) system. Before the SPS synthesis, the ingots were synthesized by vacuum induction melting and followed by annealing. For phase analysis X-ray powder diffraction patterns were checked. All the samples were confirmed as single phase; however, with samples that were more doped than the solubility limit some secondary phases were detected. All the samples doped with Ni and Te atoms showed a negative Seebeck coefficient and their electrical conductivities increased with the doping amount up to the solubility limit. For the samples prepared by SPS the maximum value for dimensionless figure of merit reached 0.26, 0.42 for $Co_{0.9}Ni_{0.1}Sb_3$, $CoSb_{2.8}Te_{0.2}$ at 690 K, respectively. These results show that the SPS method is effective in this system and Ni/Te dopants are also effective for increasing thermoelectric properties of this system.

치과용 지르코니아로 제작된 심미보철물의 임상적 예후에 관한 문헌고찰 (Review of clinical studies applying yttrium tetragonal zirconia polycrystal-based esthetic dental restoration)

  • 김재홍
    • 대한치과기공학회지
    • /
    • 제42권4호
    • /
    • pp.307-312
    • /
    • 2020
  • Application of ceramic materials for fabrication of dental restoration materials has been a focus of interest in the field of esthetic dentistry. The ceramic materials of choice are glass ceramics, spinel, alumina, and zirconia. The development of yttrium tetragonal zirconia polycrystal (YTZP)-based systems is a recent addition to all-ceramic systems that have high strength and are used for crowns and fixed partial dentures. Computer-aided design/computer-aided manufacturing (CAD/CAM)-produced, YTZP-based systems are popular with respect to their esthetic appeal for use in stress-bearing regions. The highly esthetic nature of zirconia and its superior physical properties and biocompatibility have enabled the development of restorative systems that meet the demands of today's patients. Many in vitro trials have been performed on the use of zirconia; however, relatively fewer long-term clinical studies have been published on this subject. The use of zirconia frameworks for long-span fixed partial dentures is currently being evaluated; in the future, more in vivo research and long-term clinical studies are required to provide scientific evidence for drawing solid guidelines. Further clinical and in vitro studies are required to obtain data regarding the long-term clinical use of zirconia-based restorations.

A Review of the Flashover Performance of High Voltage Insulators Constructed with Modern Insulating Materials

  • Khatoon, Shabana;Khan, Asfar Ali;Singh, Sakshi
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권5호
    • /
    • pp.246-249
    • /
    • 2017
  • Pollution flashover of outdoor insulators is a common risk, which affects the safe operation of overhead transmission networks. Early electrical power systems, which feature insulators made from ceramic materials have been used all over the world with good performance. At present, non-ceramic insulators are in common use, as a result of their good electrical as well as mechanical properties. The aim of this paper is to discuss and compare the flashover performance of insulators typically used in power lines, such as, porcelain, ethylene-propylene-diene-monomer (EPDM) rubber, room temperature vulcanized (RTV) and high temperature vulcanized (HTV) coated silicone rubber. The effect of various parameters, including the severity of pollution, ice accumulation, and shade profile, are considered.. From the studies reviewed it was concluded that there is a distinct difference in the flashover voltages of different types of insulators, and the silicone provides the best flashover performance of all insulating materials.

Homologous 산화물 ZnkIn2O3+k(k=1∼9)의 열전 특성 (Thermoelectric Properties of ZnkIn2O3+k(k=1∼9) Homologous Oxides)

  • 남윤선;최정규;홍정오;이영호;이명현;서원선
    • 한국재료학회지
    • /
    • 제13권8호
    • /
    • pp.543-549
    • /
    • 2003
  • In order to investigate the thermoelectric properties of $Zn_{k}$ $In_2$$O_{ 3+k}$ homologous compounds, the samples of $Zn_{k}$ /$In_2$$O_{3+k}$ / (k = integer between 1 and 9) were prepared by calcining the mixed powders of ZnO and $In_2$$O_3$fellowed by sintering at 1823 K for 2 hours in air, and their electrical conductivities and Seebeck coefficients were measured as a function of temperature in the range of 500 K to 1150 K. X-ray diffraction analysis of the sintered samples clarified that single-phase specimens were obtained for $Zn_{k} /$In_2$$O_{3+k}$ with k = 3, 4, 5, 7, 8, 9. Electrical conductivity of the $Zn_{k}$ $In_2$$O_{3+k}$ / decreased with increasing temperature, and decreased with increasing k for k $\geq$ 3. The Seebeck coefficient was negative at all the temperatures for all compositions, confirming that $Zn_{k}$ $In_2$$O_{3+k}$ / is an n-type semiconductor. Absolute values of the Seebeck coefficient increased linearly with increasing temperature and increased with increasing k for k $\geq$ 3. The temperature dependence of the Seebeck coefficient indicated that Z $n_{k}$I $n_2$ $O_{3+k}$ could be treated as an extrinsic degenerate semiconductor. Figure-of-merits of Z $n_{k}$I $n_2$ $O_{3+k}$ were evaluated from the measured electrical conductivity and Seebeck coefficient, and the reported thermal conductivity. Z $n_{7}$ I $n_2$ $O_{10}$ has the largest figure-of-merit over all the temperatures, and its highest value was $1.5{\times}$10$^{-4}$ $K^{-1}$ at 1145 K.5 K.

Physical characteristics of ceramic/glass-polymer based CAD/CAM materials: Effect of finishing and polishing techniques

  • Ekici, Mugem Asli;Egilmez, Ferhan;Cekic-Nagas, Isil;Ergun, Gulfem
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권2호
    • /
    • pp.128-137
    • /
    • 2019
  • PURPOSE. The aim of this study was to compare the effect of different finishing and polishing techniques on water absorption, water solubility, and microhardness of ceramic or glass-polymer based computer-aided design and computer-aided manufacturing (CAD/CAM) materials following thermocycling. MATERIALS AND METHODS. 150 disc-shaped specimens were prepared from three different hybrid materials and divided into five subgroups according to the applied surface polishing techniques. All specimens were subjected up to #4000 grit SiC paper grinding. No additional polishing has been done to the control group (Group I). Other polishing procedures were as follows: Group II: two-stage diamond impregnated polishing discs; Group III: yellow colored rubber based silicone discs; Group IV: diamond polishing paste; and Group V: Aluminum oxide polishing discs. Subsequently, 5000-cycles of thermocycling were applied. The analyses were conducted after 24 hours, 7 days, and 30 days of water immersion. Water absorption and water solubility results were analyzed by two-way ANOVA and Tukey post-hoc tests. Besides, microhardness data were compared by Kruskal-Wallis and MannWhitney U tests (P<.05). RESULTS. Surface polishing procedures had significant effects on water absorption and solubility and surface microhardness of resin ceramics (P<.05). Group IV exhibited the lowest water absorption and the highest microhardness values (P<.05). Immersion periods had no effect on the microhardness of hybrid ceramic materials (P>.05). CONCLUSION. Surface finishing and polishing procedures might negatively affect physical properties of hybrid ceramic materials. Nevertheless, immersion periods do not affect the microhardness of the materials. Final polishing by using diamond polishing paste can be recommended for all CAD/CAM materials.

상악 중절치 삭제 시 수복 디자인과 변연부 위치에 따른 부피 변화 (Volume difference in upper central incisor preparation according to the changes of restorative design and marginal location)

  • 김종현;박영범;김성태;이근우
    • 대한치과보철학회지
    • /
    • 제49권2호
    • /
    • pp.152-160
    • /
    • 2011
  • 연구 목적: 상악 중절치에 여러 가지 수복물 설계와 변연부 위치를 설정하여 치아 삭제를 하였을 때 나타나는 치아 삭제량의 변화를 평가하기 위함이다. 연구 재료 및 방법: 36개의 상악 중절치 레진 인공치가 실험에 사용되었다. 수복물의 디자인에 따라 이들은 4개의 군으로 나뉘었다. 그리고 각각의 군은 다시 변연부의 위치에 따라 3개의 세부 군으로 나뉘었다. 삭제되지 않은 치아의 부피가 미세단층촬영을 이용해 측정되었고 같은 방법으로 삭제 후의 치아의 부피가 측정되었다. 이 측정된 영상들을 서로 겹쳐서 비교함으로 삭제 전과 후의 부피 변화를 알아보았다. 결과: 수복물 설계에 따른 삭제 전과 후의 부피 변화량은 다음과 같은 순서로 변화량의 차이를 보였다: traditional laminate veneer < full laminate veneer < all ceramic crown < metal ceramic crown. One-Way ANOVA와 다중비교 Tukey로 유의수준5%에서 통계 분석한 결과 각각의 군에서는 다음과 같은 순서로 변화량의 차이를 보였다: CEJ 1 mm 상방 < CEJ < CEJ 1 mm 하방 (P<.05). 부피 변화를 백분율로 나타낸 수치를 보면 all ceramic crown과 metal ceramic crown 에서는 31 - 48% 로 나타났고 laminate veneer에서는 14 - 30%로나타났다. Laminate veneer에서 나타난 부피 변화량은 metal ceramic crown의 1/3로 나타났다. The full laminate (CEJ 1 mm 하방)와 all ceramic crown (CEJ 1 mm 상방)는 유사한 부피 변화를 보였다. Metal ceramic crown은 all ceramic crown과 비교하였을 때 13.7% 더 많은 부피 변화를 보였다. 결론: 수복물의 설계와 변연부 위치의 변화에 따라 부피 변화의 차이가 존재한다.

비금속 포스트 코어가 전부도재관에 미치는 광학적인 영향 (OPTICAL EFFECTS OF NONMETALLIC POST AND CORE SYSTEMS ON ALL-CERAMIC CROWNS)

  • 김성원;조인호;임주환;임헌송
    • 대한치과보철학회지
    • /
    • 제40권5호
    • /
    • pp.493-506
    • /
    • 2002
  • Recently as the esthetic concerns about dental prosthesis have been increased, the nonmetallic post and core systems have been introduced clinically to improve the color and the low optical transmittance of conventional casting metal post and core systems. The purpose of this study was to compare and analyze the optical transmittance and the shade changes of all-ceramic crowns with two nonmetallic post and core systems. The experimental groups were classified as follows : Total 27 specimens(9 samples in each group) were evaluated. Group I : Natural teeth as a control group Group II : CosmoPost and $Empress^{(R)}$ core (Ivoclar-Vivadent, Liechtenstein) Group III : $LIGHT-POST^{TM}$ and $LIGHT-CORE^{TM}$ (Bisco, U.S.A.) In all group, all-ceramic crowns were fabricated with the same shade of IPS $Empress^{(R)}$ II (Ivoclar-Vivadent, Liechtenstein) after abutment preparation, and then two kinds of spectrophotometers, UV 3101 PC (Shimadzu, Japan) and CM 503i (Minolta Co. Ltd. Japan), were used to measure the optical transmittance and the color value. The following results were obtained : 1. The optical transmittance of each group without all-ceramic crowns, was siginificantly decreased in order of Group III, I and II (p<0.05). 2. The optical transmittance of each group with all-ceramic crowns cemented, were siginificantly decreased in order of Group I, II and III (p<0.05). 3. In comparison with the shade of all-ceramic crowns, there were no significant differences between groups regardless of the cementation. 4. In comparison with the shade changes in each group after the cementation of all-ceramic crowns, there were no significant differences between groups. From the above results, it is thought that the selection among materials used in this study doesn't influence greatly the esthetic restoration, because the differences of optical transmittance were so small that those were clinically insignificant.