• Title/Summary/Keyword: All-bond 2

Search Result 793, Processing Time 0.022 seconds

AN EXPERIMENTAL STUDY FOR THE EFFECT OF ALL-BOND 2, GLUMA, SCOTCH BOND MULTI-PURPOSE (수종 상아질 접착제의 제 V급 와동에서의 미세 변연누출에 관한 비교연구)

  • Kang, Chang-Seong;Park, Seong-Ho;Lee, Chong-Suck
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.261-274
    • /
    • 1995
  • This study aimed to evaluate the marginal microleakage of Class V cavities of All-bond 2 (Wet - bonding system), Gluma (Adhesion of resin to exposed collagen fibers), and Scotchbond Multi-purpose(Mild Etching System). Hundred extracted human teeth divided into a control and three experimental groups consisting of eight teeth. The experimental group was further subdivided into All- bond2, Gluma and Scotchbond MP groups, Vitrebond served as the control. The positive control group consisted of specimens filled with resin and with no etching, primer and bonding procesure. Polished specimens underwent temperature changed from $5^{\circ}C$ to $55^{\circ}C$ a thousand times. After thermocycling, speciemens were placed in 2 % methylene blue dye solution for 24 hours in an incubator set at $37^{\circ}C$. The teeth were sectioned buccolingually and the degree of dye penetration was observed with a stereomicroscoped(*20). The following results were obtained. 1. Both the control and the experimental group showed a lower degree of dye penetration on enamel than on dentin margins(p<0.05) 2. Gluma exhibited a statistically significant lower degree of dye penetration than All-bond 2 on enamel margins(p<0.05) Scotchbond MP also exhibited a lower degree of dye penetration than All-bone 2 but was no statistically significant. Gluma and Scotchbond MP exhibited a similar degree of dye penetration. 3. The degree of dye penetration of All-bond 2, Gluma and Scotch bond MP showed no statistically singnificance on enamel margins but was significantly lower than in the control using Vitrebond. 4. All-bond 2 exhibited a statistically significant lower degree of dye penetration than Gluma on dentin margins. All- bond 2 and Scotchbond MP showed a similar degree of dye penetration. 5. The degree of dye penetration of All-bond 2, Gluma and Scotchbond MP showed no statistically significance on dentin margins. There was neither a statistical significance with the control.

  • PDF

Comparative evaluation of micro-shear bond strength between two different luting methods of resin cement to dentin (합착 술식에 따른 레진 합착제의 상아질에 대한 미세전단결합강도의 비교 연구)

  • Lee, Yoon-Jeong;Park, Sang-Jin;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.283-293
    • /
    • 2005
  • The purpose of this study was to evaluate the effect of dual bonding technique by comparing microshear bond strength between two different luting methods of resin cement to tooth dentin. Three dentin bonding systems(All-Bond 2, One-Step, Clearfil SE Bond), two temporary cements (Propac, Freegenol) were used in this study. In groups used conventional luting procedure, dentin surfaces were left untreated. In groups used dual bonding technique, three dentin bonding systems were applied to each dentin surface. All specimens were covered with each temporary cement. The temporary cements were removed and each group was treated using one of three different dentin bonding system. A resin cement was applied to the glass cylinder surface and the cylinder was bonded to the dentin surface. Then, micro-shear bond strength test was performed. For the evaluation of the morphology at the resin/dentin interface, SEM examination was also performed. 1. Conventional luting procedure showed higher micro-shear bond strengths than dual boning technique. However, there were no significant differences. 2. Freegenol showed higher micro-shear bond strengths than Propac, but there were no significant differences. 3. In groups used dual bonding technique, SE Bond showed significantly higher micro-shear bond strengths in One-Step and All-Bond 2 (p<0.05), but there was no significant difference between One-Step and All-Bond 2. 4. In SEM observation, with the use of All-Bond 2 and One-Step, very long and numerous resin tags were observed. This study suggests that there were no findings that the dual bonding technique would be better than the conventional luting procedure.

A STUDY ON THE SHEAR BOND STRENGTH AND SCANNING ELECTRON MICROSCOPIC INVESTIGATION OF DENTIN BONDING AGENTS (상아질 접착제의 전단결합강도 및 주사전자현미경적 연구)

  • Lee, Gi-Hwan;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.289-302
    • /
    • 1995
  • The purpose of this study was to estimate the shear bond strength and observe the fractured and interfacial surfaces of various dentin bonding agents used conjunction with a visible light cured composite. The senentytwo human premolars and molars extracted due to periodontal or orthodontic reasons were used and randomely divided into six groups. All the prepared dentin surfaces were treated with Superbond D-liner, Scotchbond Multi-Purpose, All-Bond 2 and Prisma Universal Bond 3 accroding to the manufacturer's instructions. Six specimens were then demineralized in 10 % HCl for 24 hours and the other six specimens were not demineralized in order to observe the interfacial surfaces with Hitachi X-450 SEM at 25Kv. Also shear bond strength were obtained using an Instron Testing Machine with a crosshead speed of 1mm/min. The following results were obtained : 1. Although shear bond strength of Superbond D-Liner(17.35 MPa) and Scotch-bond Multi-Purpose group(17.29 MPa) were higher than the All-Bond 2(12.80 MPa) and Prisma Universial Bond 3 (13.43 MPa), there were no significant statistic differences in the shear bond strength between 4 groups.(P<0.05) As a result of etching to dentin in Prism a Universial BOND 3 experimentally, the resin tag was formed, but shear bond strength was decreased. 2. The resin tag into the opened dentinal tubule was formed in Superbond D-Liner, Scotchbond Multi-Purpose, All-Bond 2(etching) and Prisma Universial Bond 3(etching), but not in the All-Bone 2 and Prism a Universial Bond 3(non-etching). 3. Strong, durable bonds between dentin and dentinal bonding agents are essential, not only resin tag into the dentinal tubules, but also hybrid layer.

  • PDF

A STUDY ON THE EFFECT OF AMALGAM CAVITY LINER APPLICATION ON THE MARGINAL LEAKAGE AND RETENTION OF AMALGAM RESTORATIONS (Amalgambond Liner의 도포가 amalgam 수복재의 변연누출과 유지력에 미치는 영향에 관한 연구)

  • Kim, Tae-Sung;Kim, Jong-Soo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.4
    • /
    • pp.800-817
    • /
    • 1996
  • In this study, we tried to evaluate the effect of Amalgambond liner application on the degree of marginal leakage and retention of amalgam restoration by comparing with that of the Copalite and All-bond 2. The results obtained from this experiment were as follows; 1. Tensile strength representing the bond between amalgam and tooth structure was the highest in Amalgambond, and All-Bond 2, Copalite in descending order. There were statistically significant difference between each group(P<0.05). 2. The degree of microleakage in Amalgambond was lower than that of All-Bond 2, and Copalite, but no stastically significant difference could be found (P>0.05). 3. The liner such as Amalgambond or All-Bond 2 were evaluated to be superior to the conventional Copalite in bond strength as well as in microleakage. But the result of this study could not show the superiority of one material over the others; Amalgambond and All-bond 2. Besides the results of the study, other factors, such as practical convenience, should be considered in determining the selection of material. The support of welldesigned clinical studies on this subject are in demand.

  • PDF

EFFECT OF THERMOCYCLING ON BONDING OF COMPOSITE RESIN AFTER DENTIN SURFACE TREATMENTS (상아질 표면처리후 복합레진 수복시 온도변화가 결합에 미치는 영향)

  • Lee, Yong-Woo;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.2
    • /
    • pp.126-142
    • /
    • 1991
  • The purpose of this study was to evaluate the effect of various dentin surface treatments on shear bond strength, microhardness and fracture mode before and after thermocycling. Recently extracted 75 human molars were used. The teeth were sagittal sectioned faciolingually to obtain 150 specimens. They were randomly divided into six groups. Mesial and distal dentinal surfaces of specimens were exposed by grinding and treated respectively with GC-DENTIN CONDITIONER. 10-3 solution of 4-Meta, Cleansar and Primer of GLUMA, Scotchprep of Scotchbond 2, DENTIN CONDITIONER and PRIMER A, B of ALL BOND according to the manufacturers directions. Specimens of one group were not treated. Adhesive agent of Scotchbond 2, were applied and cured on the treated dentin surfaces. After P-50 were cured on them, specimens were stored in 31c water for 24 hours before shear bond strength measurement Shear bond strength was measured in 10 specimens of each group. 10 specimens of each group were thermocycled in $20^{\circ}C$, $60^{\circ}C$,$20^{\circ}C$, $4^{\circ}C$, $20^{\circ}C$ water in order, for 30 seconds respectively, 100 times a day for 7 days. After thermocycling shear bond strength was measured. Microhardness was checked on treated dentin surface and fractured dentin surface in 10 specimens respectievly. Francture modes were observed with SEM The following results were obtained. 1. Before thermocycling. shear bond strengths in the specimens treated with DENTIN CONDITIONER and PRIMER A, B of ALL BOND were significantly higher than those in other specimens(P<0.01). 2. After thermocycling. shear bond strengths in the specimens treated with Cleanser and Primer of GLUMA, Scotchprep of Scotchbond 2 and DENTIN CONDITIONER and PRIMER A, B of AIL BOND were significantly higher than those in specimens not: treated, treated with GC-DENTIN CONDITIONER and 10-3 solution of 4-Meta(P<0.01). Shear bond strengths in the specimens treated with GC-DENTIN CONDITIONER and PRIMER A, B of ALL BOND were significantly higher than those in other specimens except those treated with Scotchprep of Srotchbond 2(P<0.01). 3. Shear bond strengths after thermocycling were reduced in the specimens not treated, treated with GC-DENTIN CONDITIONER and 10-3 solution of 4-Meta and were increased in the specimens treated with Cleanser and Primer of GLUMA, Scotchprep of Scotchbond 2, without significance, compared with those before thermocycling. In the specimens treated with DENTIN CONDITIONER and PRIMER A, B of ALL BOND, shear bond strengths after thermocycling were significantly increased, compared with those before thermocycling(P<0.01). 4. Microhardnesses in the fractured surfaces after shear bond strength measurement were significantly increased in the specimens treated with 10-3 solution of 4-Meta and significantly decreased in the specimens treated with DENTIN CONDITIONER and PRIMER A, B of ALL BOND, compared with those in the treated dentin surfaces(P<0.01). 5. In the specimens treated with Cleanser and Primer of GLUMA, Scotchprep of Scotchbond 2 and DENTIN CONDITIONER and PRIMER A, B of ALL BOND, cohesive fracture modes were observed more than adhesive fracture modes.

  • PDF

A STUDY OF TENSILE BOND STRENGTH ACCORDING TO VARIED TREATMENT METHODS OF NONPRECIOUS METAL SURFACE AND RESIN CEMENTS (비귀금속합금 표면처리방법과 레진시멘트 종류가 접착인장강도에 미치는 영향에 관한 연구)

  • Yang, Tai-Jin;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.335-348
    • /
    • 1996
  • Retention is one of the major factors deciding the success and longevity of resin bonded restorations. The purpose of this study was to find a better resin cement and metal surface treatment method that would enhance the bonding strength. The bonding surfaces of Verabond, one of Ni-Cr-Be alloys, were treated with sandblasting(Group 1), sandblasting and EZ-Oxisor(Group 2), sandblasting and silicoating(Group 3), and than thay were bonded with All-Bond C & B, Panavia 21, Superbond C & B. The specimens were thermocycled, and the tensile bond strength was measured using the unive-rsal testing machine. Also the mode of bond failure was observed. The results were as folows. 1. The Superbond C & B showed the highest bond strength among the three resin cements and decreased in the order of Panavia 21, All-Bond C & B. There was significant differe-nce among them(p<0.05). 2. Group 3 showed the highest bond strength among the three metal surface treatment methods, and there was significant difference compared with Group 1 and Group 2(p<0.05). But there was no significant difference between Group 1 and Group 2. 3. Observing the mode of bond failure, Superbond C & B and Panavia 21 showed mostly cohesive failure in all groups. All-Bond C & B showed all types of bond failure in Group 3, but Group 1 and Group 2 showed only adhesive failure. 4. According to the results of this study, the silicoating method and 4-META containing resin cement were considered to be more acceptable for resin bonded restoration.

  • PDF

EFFECT OF BENZALKONIUM CHLORIDE ON DENTIN BONDING WITH BPDM/HEMA SYSTEM (Benzalkonium Chloride가 BPDM/HEMA계 접착제의 상아질 접착에 미치는 영향)

  • Kwon, Byung-Gyun;Ahn, Sik-Hwan;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.2
    • /
    • pp.569-584
    • /
    • 1996
  • The purpose of this study was to elucidate the effect of benzalkonium chloride on tensile bond strength of BPDM/HEMA dentin bonding. One hundred sixty dentin specimens from freshly extracted bovine mandibular incisors were used, and 0, 0.02, 0.1 or 0.5% benzalkonium chloride solution was applied to the dentin specimen with/after phosphoric acid. 32% phosphoric acid was used when the specimens were bonded with One-Step$^{TM}$, a BPDM/HEMA system and 10% was used when bonded with All-Bond$^{(R)}$ 2, a NTG-GMA/BPDM system. Aelitefil$^{TM}$ composite resin was bonded to the pretreated dentin specimen with the use of All-Bond$^{(R)}$ 2 or One-Step$^{TM}$ dentin bonding agent. After the bonded specimens were stored in $37^{\circ}C$ distilled water for 24 hours, tensile bond strength was measured. The fractured dentin specimens were examined under the scanning electron microscope. The results were as follows : Benzalkonium chloride application after acid-treatment resulted in decrease of dentin bond strength of One-Step$^{TM}$, a BPDM/HEMA system (p>0.05). Benzalkonium chloride application did not exert any influence on dentin bond strength of All-Bond$^{(R)}$ 2, a NTG-GMA/BPDM system (p>0.05). There was no relationship between the concentration or application method of benzalkonium chloride and the dentin bond strength of One-Step$^{TM}$ or All-Bon$^{(R)}$ 2 (p<0.05). On SEM examination of the fractured dentin-resin interface, while mixed failure was prominent in dentin bonding with One-Step$^{TM}$, adhesive and mixed failures were seen together in dentin bonding with All-Bond$^{(R)}$ 2 regardless of the concentration and application method of benzalkonium chloride.

  • PDF

Comparison of Push-out Bond Strengths According to Relining Procedure and Cement Type on Fiber Post (Fiber post의 Relining 방법과 시멘트 유형에 따른 Push-out Bond Strength의 비교)

  • Kang, Hyun-Young;Cho, So-Yeun;Yu, Mi-Kyung;Lee, Kwang-Won;Kim, Kyoung-A
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.3
    • /
    • pp.253-265
    • /
    • 2011
  • When restoring endodontically treated teeth is the mismatch between fiber post size and post space diameter, the resin cement layer is excessively thick in post space and voids are likely to form in it, thus predisposing to de-bonding. The method to overcome this problem is to reline the fiber post with composite resin. This individual anatomic post improves the adaptation of post to root walls and decreases the resin cement thickness. The purpose of this in vivo study was to evaluate the push-out bond strength of fiber post according to relining procedure and luting agents type used for simplicity of clinical procedure. Forty-two extracted teeth were divides into six groups.(n=7) A1: relined fiber post cemented with Luxacore/all-bons 2, A2: non-relined fiber post cemented with Luxacore/all-bond2, B1: relinind fiber post cemented with Calibra/XP-bond, B2: non-relined fiber post cemented with Calibra/XP-bond, C1: relined fiber post cemented with RelyX Unicem, C2: non-relined fiber post cemented with RelyX Unicem Push-out bond strength was affected by interaction between relining procedure and luting agent type. Relined fiber post presented higher push-out bond strength value than non-relined fiber post and statically significant differences(p<0.05) Cementation with RelyX Unicem showed significantly higher bond strength than other luting agents(p<0.05).

Effects of one or two applications of all-in-one adhesive on microtensile bond strength to unground enamel (Unground enamel에 대한 all-in-one adhesive의 1회 또는 2회 적용이 미세인장 결합강도에 미치는 영향)

  • Son, Chang-Yong;Kim, Hyeon-Cheol;Hur, Bock;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.6
    • /
    • pp.445-451
    • /
    • 2006
  • The purposes of this study were to compare the effects of one or two applications of all-in-one adhesives on microtensile bond strengths (${\mu}$TBS) to unground enamel and to investigate the morphological changes in enamel surfaces treated with these adhesives using a scanning electron microscopy (SEM). Twenty-five noncarious, unrestored human mandibular molars were used. The unground enamel surfaces were cleansed with pumice. The following adhesives were applied to lingual, mid-coronal surfaces according to manufacture's directions; Clearfil SE bond in SE group, Adper Prompt L-Pop$^{TM}$1 coat in LP1 group, 2 coats in LP2 group, Xeno$^{\R}$III1 coat in XN1 group, and 2 coats in XN2 group. After application of the adhesives, a hybrid light-activated resin composite was built up on the unground enamel. Each tooth was sectioned to make a cross-sectional area of approximately 1.0 mm$^2$ for each stick. The microtensile bond strength was determined. Each specimen was observed under SEM to examine the morphological changes. Data were analyzed with one-way ANOVA. The results of this study were as follows; 1. The microtensile bond strength values were; SE (19.77 ${\pm}$ 2.44 MPa), LP1 (13.88 ${\pm}$ 3.67 MPa), LP2 (14.50 ${\pm}$ 2.52 MPa), XN1 (14.42 ${\pm}$ 2.51 MPa) and XN2 (15.28 ${\pm}$ 2.79 MPa). SE was significantly higher than the other groups in bond strength (p < 0.05). All groups except SE were not significantly different in bond strength (p < 0.05). 2. All groups were characterized as shallow and irregular etching patterns.

In vitro Measurement of the Mechanical Properties of Resin Infiltrant: Viscosity, Penetration Pattern, Surface Roughness, Microhardness (초기 법랑질 우식 병소에 대한 Resin infiltrant의 점도, 침투 양상, 표면 조도 및 미세경도)

  • Hong, Seung-Hyun;Kim, Min-Jeong;Cho, Hye-Jin;Yu, Mi-Kyung;Lee, Kwang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.1
    • /
    • pp.81-90
    • /
    • 2011
  • In this study, we observed the penetration of the resin infiltrant into natural initial caries by SEM and CLSM, evaluated the pH and viscosity of resin infiltrant and several adhesives(All-bond 2, Scotchbond Multi-purpose, Clearfil SE bond), and measured the surface roughness and the microhardness on permanent teeth before and after applied resin infiltrant into initial enamel caries. The viscosity(Pa.s) was observed for resin infiltrant($0.173{\pm}0.012$), All-bond 2($0.754{\pm}0.030$), Scotchbond Multi-purpose($1.46{\pm}0.137$), and Clearfil SE bond($1.28{\pm}0.125$). The pH was measured for resin infiltrant (4.7), All-bond 2(7.5), Scotchbond Multi-purpose(8.2), and Clearfil SE bond(4.67). An application procedure of resin infiltrant increased the surface roughness and the microhardness insignificantly(p>0.05), when compared to non-applied specimens.