• Title/Summary/Keyword: Alkasite restorative

Search Result 8, Processing Time 0.016 seconds

Alkasite restorative material for endodontically treated teeth: a randomized controlled pilot study

  • Davi Ariel Nobuo Bepu;Renata Siqueira Scatolin;Natalia Saud Junqueira Franco;Luiza Pejon Sanchez;Aline Evangelista Souza-Gabriel;Silmara Aparecida Milori Corona
    • Restorative Dentistry and Endodontics
    • /
    • v.49 no.3
    • /
    • pp.24.1-24.13
    • /
    • 2024
  • Objectives: This study aimed to evaluate the clinical performance of an alkasite restorative material in molars that had undergone root canal treatment. Materials and Methods: The research was registered in Brazilian Registry of Clinical Trials. The randomized clinical trial involved 33 patients, each with at least 1 mandibular molar requiring restoration after receiving endodontic treatment. Patients were randomly assigned to receive either bulk-fill resin composite (Tetric N Ceram Bulk Fill, Ivoclar Vivadent) or the alkasite restorative material (Cention N, Ivoclar Vivadent). Upon completion of the restorations, 3 calibrated professionals utilized the United States Public Health Service criteria to assess various factors, including retention, secondary caries, marginal adaptation, restoration color, marginal pigmentation, and anatomical form. Evaluations were conducted at intervals of 7 days, 6 months, and 17 months. Additionally, the assessment encompassed the presence of radiolucent lines adjacent to the restoration, material deficiencies or excess, contact points, and caries recurrence. The data underwent analysis using the Friedman and Mann-Whitney tests (α = 0.05). Results: After 17 months, the results revealed that the alkasite restorative material exhibited greater wear of anatomical shape compared to the bulk-fill resin composite (p = 0.0189). Furthermore, the alkasite restorative material significantly differed from the natural tooth color in most cases (p = 0.0000). However, no other criteria displayed significant differences between the materials or over time (p > 0.05). Conclusions: The alkasite restorative material (Cention N) emerges as a viable option for restoring endodontically treated teeth, displaying clinically acceptable alterations after a 17-month evaluation period.

Color Stability of Alkasite Restorative Material: in vitro Studies (알카자이트 수복재의 색안정성 : 실험실적 연구)

  • Jihye, Ahn;Sangho, Lee;Nanyoung, Lee; Hyewon, Shin;Myeongkwan, Jih
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.4
    • /
    • pp.428-441
    • /
    • 2022
  • The purpose of this study is was to compare the color stability of alkasite and other restorative materials commonly used in the field of pediatric dentistry and to study a color change in response to various beverages. Test specimens of glass ionomer, resin modified glass ionomer, alkasite restorative material, and composite resin were prepared, and the color stability was measured after thermocycling. Each specimen was also subdivided into 5 groups and submerged in PBS, coffee, green tea, coke, and orange juice to analyze the color change from the original CIE L*a*b* values after 7, 14, 21, and 28 days. Composite resin showed the best color stability after thermocycling, followed by alkasite restorative material, glass ionomer, and resin modified glass ionomer. Submerging in various beverages for 7 days resulted in color change in all test specimens, with alkasite restorative material showing less color change than glass ionomer but greater change than composite resin. Alkasite restorative material showed the greatest color change in coffee, followed by green tea and orange juice, but almost no change in coke and PBS even after 28 days of submersion.

Comparison of Microhardness and Compressive Strength of Alkasite and Conventional Restorative Materials (Alkasite와 기존의 수복 재료의 압축강도 및 미세경도 비교)

  • Lee, Kunho;Kim, Jongsoo;Shin, Jisun;Han, Miran
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.3
    • /
    • pp.320-326
    • /
    • 2020
  • The aim of this study was to compare compressive strength and microhardness of recently introduced alkasite restorative materials with glass ionomer cement and flowable composite resin. For each material, 20 samples were prepared respectively for compressive strength and Vickers microhardness test. The compressive strength was measured with universal testing machine at crosshead speed of 1 mm/min. And microhardness was measured using Vickers Micro hardness testing machine under 500 g load and 10 seconds dwelling time at 1 hour, 1 day, 7 days, 14 days, 21 days and 35 days. The compressive strength was highest in composite resin, followed by alkasite, and glass ionomer cement. In microhardness test, composite resin, which had no change throughout experimental periods, showed highest microhardness in 1 hour, 1 day, and 7 days measurement. The glass ionomer cement showed increase in microhardness for 7 days and no difference was found with composite resin after 14 days measurement. For alkasite, maximum microhardness was measured on 14 days, but showed gradual decrease.

Fluoride Release of Several Types of Fluoride-Containing Restorative Materials According to Fluoride Concentration in Toothpaste (치약 내 불소농도에 따른 수종의 불소함유 수복재의 불소 방출량)

  • Chungho, Lee;Jewoo, Lee;Jiyoung, Ra
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.2
    • /
    • pp.197-205
    • /
    • 2022
  • This study was conducted to investigate the fluoride release of fluoride-containing restorative materials in fluoride recharging according to the concentration of fluoride toothpaste used in Korea. Samples of glass ionomer cement, resin-modified glass ionomer cement, alkasite restorative material, and composite resin were prepared and fluoride release was measured on days 1, 3, 7, 14, 21, 28. Thereafter, fluoride-free, 500 ppm, and 1450 ppm fluoride toothpaste was applied to each restorative materials, and the fluoride release was measured on days 1, 3, 7. Glass ionomer cement showed the highest cumulative fluoride release until the 7th day of measurement, and from the 14th day onwards, the resin-modified glass ionomer cement showed the highest cumulative fluoride release, but there was no significant difference. When restorative material groups were recharged with 500 ppm of fluoride toothpaste, the fluoride release was significantly higher only for the alkasite restorative material compared to the fluoride-free toothpaste group (p < 0.017). When restorative material groups were recharged with 1450 ppm of fluoride toothpaste, the fluoride release was significantly higher in all restorative groups compared to the fluoride-free toothpaste group (p < 0.017).

Fluoride Release and Recharge Properties of Several Fluoride-Containing Restorative Materials (수종의 불소함유 수복재의 불소 유리 및 재충전)

  • Lee, Dongyun;Kim, Jongsoo;Han, Miran;Shin, Jisun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.2
    • /
    • pp.196-204
    • /
    • 2020
  • The aim of the study is to compare the fluoride release and recharge properties of glass ionomer cements and 'alkasite'. Specimens of two glass ionomer cements (Fuji IX GP and Riva Self Cure), 'alkasite' restorative material (Cention N) and composite resin (Filtek™ Z350XT) were prepared. The fluoride release of each specimen was measured for 28 days. Thereafter, 1.23% acidulated phosphate fluoride (APF) gel was applied to experimental groups. No treatment was performed on control groups. The fluoride release was measured for additional 7 days to evaluate the fluoride recharge properties of each materials. The fluoride release was highest in Riva Self Cure, followed by Fuji IX GP, Cention N (p < 0.05). Fluoride release of Cention N was measured to be approximately 49% of Fuji IX GP's. After the application of 1.23% APF gel, increases in fluoride release were observed in Riva Self Cure, Fuji IX GP and Cention N (p < 0.05). Fluoride recharge was observed in Cention N as well as in glass ionomer cements. Further studies are required to evaluate the anti-cariogenic properties of Cention N at clinical conditions.

Assessment of Fluoride Release through Dentin Adhesive in the Alkasite Restorative Material and Giomer (알카자이트 수복재와 자이오머의 상아질 접착제를 투과하는 불소 유리 평가)

  • Kim, Haeni;Park, Howon;Lee, Juhyun;Seo, Hyunwoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.4
    • /
    • pp.367-375
    • /
    • 2021
  • This study evaluated the fluoride release of alkasite restorative material (ARM) and giomer penetrating the dentin adhesive layer. Twenty specimens were prepared for each restorative material, and dentin adhesive with uniform thickness was applied to half of them. The prepared specimens were placed in a polyethylene tube containing 2.0 mL of deionized water and deposited in a 37.0℃ water bath for the study duration. The amount of fluoride release was measured on the 1st, 3rd, 7th, 14th, 21st, and 28th days after deposition. The dentin adhesive applied to the ARM and giomer could not completely block the fluoride release; however, it significantly reduced its amount. The cumulative amount of fluoride release of the ARM after 28 days was higher than that of the giomer regardless of the application of dentin adhesive.

Surface Roughness and Microbial Adhesion After Finishing of Alkasite Restorative Material (피니싱 처리 이후 알카자이트 수복재의 표면거칠기와 미생물 부착)

  • Park, Choa;Park, Howon;Lee, Juhyun;Seo, Hyunwoo;Lee, Siyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.2
    • /
    • pp.188-195
    • /
    • 2020
  • This study is aimed to evaluate and compare the surface roughness and microbial adhesion to alkasite restorative material (Cention N), resin-modified glass ionomer (RMGI), and composite resin. And to examine the correlation between bacterial adhesion and surface roughness by different finishing systems. Specimens were fabricated in disk shapes and divided into four groups by finishing methods (control, carbide bur, fine grit diamond bur, and white stone bur). Surface roughness was tested by atomic force microscope and surface observation was performed by scanning electron microscope. Colony forming units were measured after incubating Streptococcus mutans biofilm on specimens using CDC biofilm reactor. Cention N surface roughness was less than 0.2 ㎛ after finishing procedure. Control specimens of resin and Cention N specimens were significantly (p = 0.01) rougher. Pearson correlation coefficient (PCC = 0.13) indicated a weak correlation between surface roughness and S. mutans adhesion to the specimens. Compared with resin specimens, RMGI and Cention N showed lower microbial adhesion. Surface roughness and bacterial adhesion were not significantly different, regardless of the finishing systems.

Comparative Analysis of Water Absorption and Water Solubility of Alkasite-based Restorative Material

  • Myeong-Gwan Jih;Hye-Jin Cho;Eu-Jin Cha;Tae-Young Park
    • Journal of Korean Dental Science
    • /
    • v.16 no.1
    • /
    • pp.74-79
    • /
    • 2023
  • Purpose: Cention N (Ivoclar Vivadent) was a recently introduced alkasite-based restorative material that was expected to replace amalgam and glass ionomer cement. This material was an esthetic restoration with adequate mechanical strength and release of fluoride and calcium. The purpose of this study was to measure the water sorption and water solubility of Cention N and evaluate its long-term durability compared to other esthetic restorations (Resin-Modified Glass Ionomer cement [RMGIC], Giomer, Composite Resin). Materials and Methods: Twenty specimens each of Cention N (CN), Resin Modified-Glass Ionomer Cement (FJ), Giomer (BF), and Composite Resin (FZ) were made. After each specimen was completely dried in a desiccator for 24 hours using a vacuum pressure pump, the specimen was weighed (m1). After that, the specimen was immersed in distilled water at 37℃ for 7 days, stored in a drying oven, and weighed (m2). After drying completely for 24 hours in a desiccator, the specimen was weighed (m3) to calculate the water absorption and water solubility using Formulas 1 and 2. The measured values were statistically processed and analyzed using SPSS, and the significance level was set at 0.05. Result: When measuring water sorption, FJ (122.61 ㎍/mm3) showed significantly higher water sorption than CN (35.42 ㎍/mm3) (P<0.05). There was no significant difference between FZ (18.03 ㎍/mm3) and BF (14.76 ㎍/mm3) (P=0.930). When measuring water solubility, CN (6.65 ㎍/mm3) showed significantly higher water solubility than FJ (1.47 ㎍/mm3) (P<0.05). Conclusion: Cention N had lower water sorption than RMGIC, but higher water solubility, indicating that it is more vulnerable to moisture and has lessened long-term durability.