• 제목/요약/키워드: Alkaline wastewater

검색결과 97건 처리시간 0.022초

수질제어 및 부식억제제에 의한 상수도관의 내부부식 제어 (Internal Corrosion Control of Drinking Water Pipes by pH and Alkalinity Control and Corrosion Inhibitor)

  • 구성은;우달식;이두진;김주환;안효원;문광순
    • 상하수도학회지
    • /
    • 제20권2호
    • /
    • pp.215-223
    • /
    • 2006
  • The internal corrosion of water distribution systems is the main cause for the problem of the public health threat as well as water leakage in the damaged pipeline, red water, and odor and taste of the tap water. This study was examined the effect of chemicals used for pH and alkalinity control and corrosion inhibitors for producing the optimal corrosion control method. Corrosion study at different pH and alkalinity indicated that these control using alkaline chemicals was effective in corrosion rate, Fe release reduction, but examined to be increased in turbidity and corrosion-by-products(TTHMs) problems. The turbidity was slightly increased, requiring caution in controlling corrosion with $Ca(OH)_2$. At pH 9.0, TTHMs concentration is increased two times corn pared with non-control of pH. Using the pipe which had experienced 28 years of exposure, iron release was decreased with the corrosion inhibitor. Consequently, pH, Alkalinity control method using alkaline chemicals must be complemented by corrosion inhibitor application for efficient corrosion control.

PAC 전처리 시 수소이온 농도에 따라 발생 가능한 알루미늄 종에 의한 나노여과막 성능 연구 (Effects of polymeric Al and hydrolysis products of PAC at different pH on performance of nanofiltration with PAC coagulation pretreatment)

  • 최양훈;권지향
    • 상하수도학회지
    • /
    • 제24권1호
    • /
    • pp.15-24
    • /
    • 2010
  • Coagulation can be used for pretreatment of NF membrane filtration. Foulants such as organic matter and particulate can be removed effectively with the process while high flux recovery is maintained. Recently various types of polyaluminium coagulants including polyaluminium chloride(PAC) are commercially available for water treatment. This study examines effects of polymeric Al and hydrolysis products of PAC on nanofiltration membrane performance. Dominant hydrolysis products were polymeric Al, $Al(OH)_3$, and ${Al(OH)_4}^{-1}$ at acidic, neutral, and alkaline pH conditions, respectively. Under acidic pH condition, flux decline was increased with increasing PAC concentrations, possibly due to polymeric Al adsorption on membrane pore and/or surfaces. For neutral and alkaline pH conditions, little flux decline was observed with increasing PAC concentrations except the highest ${Al(OH)_4}^{-1}$ concentration, with which rapid flux decline was shown. Removal of ionic matters was also varied with pH conditions in this study. Especially, conductivity removal was substantially low and $Ca^{2+}$ concentration in the permeate was quite high at neutral pH condition.

효소에 의한 초지용 펠트의 세척효과 (Cleaning Effect of Papermaking Felt with Enzymes)

  • 윤병태;김성보;엄태진;최명재
    • 펄프종이기술
    • /
    • 제37권3호
    • /
    • pp.17-22
    • /
    • 2005
  • The cleaning efficiency of papermaking felt which is contaminated with fiber fines and various micro-materials was investigated and compared between the application of enzyme and commercial detergent. It was found that the cleaning efficiency by the treatment of acidic-based detergent was more efficient than that of alkaline-based one in the conventional commercial detergent. it was also observed that the treatment design of first acidic-based detergent treatment to second alkaline-based detergent procedure was better in the cleaning efficiency, compared to alkaline based-to-acidic based one. The cleaning property of felt with enzyme was resulted in good cleaning efficiency, without any addition of surfactant. Especially, the enzyme treatment under alkaline condition (pH 10) showed a better cleaning result than that under acidic condition(pH 5). The addition of nonionic surfactant to the enzyme increased the cleaning efficiency of felt and decreased the cationic demand of wastewater. These results showed more favour than the application of conventional commercial detergent.

아연백법 및 공침공정을 이용한 복합 중금속-시안착염 폐수의 현장처리(II) (The Treatment of Heavy Metal-cyanide Complexes Wastewater by Zn$^{+2}$/Fe$^{+2}$ Ion and Coprecipitation in Practical Plant (II))

  • 이종철;이영만;강익중
    • 대한환경공학회지
    • /
    • 제30권5호
    • /
    • pp.524-533
    • /
    • 2008
  • 도금산업에서 배출되는 폐수는 독성이 강한 시안이온과 시안착화합물, 그리고 다양한 중금속이 함유되어 있다. 이러한 독성이 강한 시안이온 및 시안 착화합물의 처리는 알칼리염소법에 의한 시안 산화처리방법이 가장 일반적으로 잘 알려진 방법이다. 이는 시안이온은 분해 가능하나 시안 착화합물의 처리는 어려운 것으로 알려져 있고, 실제로 산업현장에서 수질환경보전법상 수질배출허용기준(나 지역) 1 mg/L을 초과하는 경우가 빈번하다. 본 연구에서는 앞서 밝힌 아연백법 및 공침공정을 이용한 복합 중금속-시안착염 폐수의 현장처리(I) (아래에서 "현장처리(I)"으로 표시 함)과 비교하여 크롬환원처리 후 Fe/Zn 공침공정을 적용하여 시안착염을 제거하고, 알칼리염소법에 의한 잔류시안 산화처리방법으로 검토하였다. 크롬처리는 6가 크롬을 3가 크롬으로 환원시 환원제로서 NaHSO$_3$를 사용하여 pH 2.0, ORP 250 mV, 반응시간 30 min.에서 99.9% 이상의 최대제거율을 얻을 수 있었다. Fe/Zn 공침에 의한 시안착염 제거실험은 pH 9.5, FeSO$_4$/ZnCl$_2$ 3.0 $\times$ 10$^{-4}$ mol, mixing rpm 240에서 시안이온의 제거효율은 98.24%(잔류시안농도: 4.50 mg/L)로 최대의 결과를 얻었다. 황화물 침전법에 의한 기타중금속(Cu, Ni)처리반응의 조건은 pH 9.0$\sim$10.0, 반응시간 30 min. mixing rpm 240에서 Cu의 경우 Na$_2$S 주입량 3.0 mol에서 99.9%, Ni의 경우 Na$_2$S 4.0 mol에서 93.86%의 최대결과를 얻었다. Fe/Zn공침처리 후 잔류시안농도 4.50 mg/L의 제거를 위하여 알칼리염소법을 실시한 결과 1차 산화반응은 pH 10.0 이상, ORP 350 mV, reaction time 30 min, 2차 산화반응은 pH 8.0 이하, ORP 650 mV, 반응시간 30 min.에서 제거효율 95.33%, 잔류시안농도 0.21 mg/L의 결과를 얻었다. 즉 (1) 크롬환원처리, (2) Fe/Zn 공침공정에 의한 시안착화합물 제거 및 기타 중금속(Cu, Ni) 처리, (3) 알칼리염소법에 의한 잔류시안 산화처리를 실시한 결과(아래에서 "현장처리(II)"로 표시 함) 시안의 잔류농도는 0.21 mg/L로서 수질 및 수생태계보전에 관한 법율의 수질배출허용기준(나 지역) 1 mg/L의 규제치 이하로 처리가 가능하다는 것을 현장 확인할 수 있었고 "현장처리(I)"보다 처리효율적인 측면이나 경제적인 측면에서 모두 양호한 결과를 얻을 수 있었다.

활성탄 개질에 따른 표면 특성 변화가 2,4-dichlorophenol 흡착성능에 미치는 영향 (Effects of chemical modification on surface characteristics and 2,4-dichlorophenol adsorption on activated carbon)

  • 안선경;송원중;박용민;양현아;권지향
    • 상하수도학회지
    • /
    • 제34권6호
    • /
    • pp.425-435
    • /
    • 2020
  • Numerous chemical modifications on activated carbon such as acidic conditioning, thermal treatment and metal impregnation have been investigated to enhance adsorption capacities of micropollutants in water treatment plants. In this study, chemical modification including acidic, alkaline treatment, and iron-impregnation was evaluated for adsorption of 2,4-dichlorophenol (2,4-DCP). For Fe-impregnation, three concentrations of ferric chloride solutions, i.e., 0.2 M, 0.4 M, and 0.8 M, were used and ion-exchange (MIX) of iron and subsequent thermal treatment (MTH) were also applied. Surface properties of the modified carbons were analyzed by active surface area, pore volume, three-dimensional images, and chemical characteristics. The acidic and alkaline treatment changed the pore structures but yielded little improvement of adsorption capacities. As Fe concentrations were increased during impregnation, the active adsorption areas were decreased and the compositional ratios of Fe were increased. Adsorption capacities of modified ACs were evaluated using Langmuir isotherm. The MIX modification was not efficient to enhance 2,4-DCP adsorption and the MES treatment showed increases in adsorption capacities of 2,4-DCP, compared to the original activated carbon. These results implied a possibility of chemical impregnation modification for improvement of adsorption of 2,4-DCP, if a proper modification procedure is sought.

아연백법 및 공침공정을 이용한 복합 중금속-시안착염 폐수의 현장처리(I) (The Treatment of Heavy Metal-cyanide Complexes Wastewater by $Zn^{+2}/Fe^{+2}$ Ion and Coprecipitation in Practical Plant(I))

  • 이종철;강익중
    • 대한환경공학회지
    • /
    • 제29권12호
    • /
    • pp.1381-1389
    • /
    • 2007
  • 중금속 폐수는 다양한 유독성 화합물과 함께 배출되므로 상수원, 토양, 지하수 등의 환경에 악영향을 야기 시킬 수 있다. 이러한 고농도의 복합중금속과 시안착염을 포함한 도금폐수 처리 시 일반적으로 잘 알려진 알카리염소법에 의한($1^{st}$ Oxidation: pH 10, reaction time 30 min, ORP 350 mV, $2^{nd}$ Oxidation: ORP 650 mV) 시안의 잔류농도에 대한 제거효율은 유입수의 시안농도 374 mg/L에 비해 처리 후 잔류시안농도는 3.74 mg/L로써 그 제거효율이 99%로써 상당히 높았으나 수질환경보전법상 수질배출허용기준(나 지역) 1 mg/L 이하에 만족하기 위해서는 2차, 3차 등의 고도처리가 요구됨을 알 수 있었고, 이에 아연백법 및 공침처리공정(reaction time: 30 min, pH: 8.0, rpm: 240)을 적용하여 용해되어 잔류하는 시안착염을 불용성염으로 침전시켜 처리한 결과 잔류시안농도가 1.0 mg/L 이하의 만족할 만한 결과를 있었다. 크롬의 처리는 6가 크롬을 3가 크롬으로 환원(pH: 2.0 max, ORP: 250 mV)시킨 후, 수산화물로 처리(pH: 9.5)시 무난히 99%의 최대 제거효율을 얻을 수 있었다. 폐수 중 나머지 동(Cu)과 니켈(Ni)처리는 황화물 응집침전법을 적용한 결과 최적 pH는 $9.0\sim10.0$에서 $Na_2S$의 최적주입량이 Cu의 경우 0.5 mol에서 99.1%, Ni의 경우 3.0 mol에서 99.0% 이상 제거할 수 있었다. 즉 중금속 복합폐수 중 시안착염은 알카리 염소산화처리법만으로는 수질환경보전법의 규제치 이하로 처리가 불가능 하였고 아연백법 및 공침공정을 같이 적용한 결과 규제치 이하로 처리가 가능하다는 것을 현장 확인할 수 있었다.

호수내의 인 제거에 관한 연구 (A Study on the Removal of Phosphorus in the Lake)

  • 강선홍;김경태
    • 상하수도학회지
    • /
    • 제12권2호
    • /
    • pp.59-66
    • /
    • 1998
  • The feasibility of usage of sludge from water treatment plant and chalk from schools and institutes was investigated to remove the phosphorus in the lakes which induce the eutrophication every year. In this study phosphorus removal efficiencies of sludge and chalk were investigated by changing various factors. Higher phosphorus removal efficiency using larger particle size of chalk was observed which means that the surface area is not an important factor in removing phosphorus in aqueous phase. The proper shaking time and temperature were 2 hours and $25^{\circ}C$, respectively. The removal efficiency using sludge from water treatment plant was almost 100%, which is similar to those of CaO and $Ca(OH)_2$. It means that sludge can be reused in removing phosphorus. It was also found that chalk was better in removing phosphorus under alkaline condition and sludge was better under acidic condition. About 75% phosphorus removal efficiency was observed using sludge from the water sample in Lake Sihwa.

  • PDF

알칼리 활성화 방법에 따른 고로슬래그 경화체 제조 연구 (Research for the production of blast furnace cement mortar using an alkaline activation method)

  • 신재란;이주열;박병현
    • 상하수도학회지
    • /
    • 제30권3호
    • /
    • pp.293-297
    • /
    • 2016
  • This study was performed in order to obtain the effect of the compressive strength of the cured product with manufacturing conditions (amounts of fine aggregate and different types of alkali activator). Material which is the basis of the cured product was used for the blast furnace slag, which has a latent hydraulic activity. Consequently, when using sodium hydroxide as the alkali activator, it is possible to obtain a higher compressive strength than using the calcium hydroxide. And also, it can be added a 10% of fine aggregate with blast furnace slag to improve the compressive strength.

혐기성 회분식 배양에서 양돈폐수의 NH$_4$-Nitrogen이 혐기성 미생물에 미치는 영향 (The Influence of Ammonium-Nitrogen on Anaerobic Microorganisms in Swine Wastewater by Batch-Fermentation.)

  • 김연옥
    • 한국미생물·생명공학회지
    • /
    • 제26권2호
    • /
    • pp.173-178
    • /
    • 1998
  • 본 연구에서는 양돈폐수의 생물학적 처리의 난점 중 하나인 NH$_4$-N이 혐기성 미생물에 미치는 영향을조사하기 위해 폐수를 여러 가지 비율로 희석하여 혐기성 회분식 배양을 시도하였으며 COD제거율과 NH$_4$-N의 농도를 측정 비교하였다. 또한 MgO를 첨가하여 폐수내의 NH$_4$-N를 $MgNH_4PO_4{cdot}6H_2O$의 결정체로 형성시킨 후 침전 제거하고 같은 조건에서 배양하였다. 3개월 이상 원폐수에서 적응된 master culture는 75%의 폐수와 25%의 희석수에서 빠른 COD 제거율을 보였으며, MAP법으로 NH$_4$-N를 60% 제거한 폐수에서는 200시간 후 80%이상의 COD 제거율을 보였다. 같은 조건에서 NH$_4$-N를 함유하고 있는 폐수는 50%정도의 COD 제거율을 보여, MAP법으로 NH$_4$-N를 제거한 폐수의 혐기성소화가 월등함을 알 수 있다. 특히 중요한 결과는 NH$_4$-N 농도가 혐기성 미생물에 미치는 영향보다는 C:N의 비율이 2이하일 때 치명적인 영향을 줌을 규명하였으며 MAP법에 의해 형성된 struvit는 혐기성 미생물에 독성 영향을 주지 않음을 알 수 있었다.

  • PDF

마그네시아를 이용한 돈분 폐수의 악취 저감(현장 시험) (Odor Reduction of Pig Wastewater Using Magnesia (in-situ test))

  • 배수호;유건상
    • 대한화학회지
    • /
    • 제66권3호
    • /
    • pp.202-208
    • /
    • 2022
  • 본 연구는 악취 제거용 반응조를 제작한 후, 현장 시험을 통해 마그네시아(MgO)를 이용하여 돈분 폐수에서 발생하는 악취를 최대한 저감하기 위한 최적 조건을 얻고자 하였다. 이를 위해 마그네시아의 충진양, 돈분 폐수의 주입량, 폭기 방식, 폭기양, 폭기 시간이 고려되었다. 현장 시험은 돈분 폐수 저장소를 갖추고 있는 청운 가축농장에서 실시하였다. 돈분 폐수(500 kg) 무게 대비 마그네시아의의 첨가량을 증가시킬수록 암모니아와 황화수소의 발생량은 점차적으로 감소하는 경향을 보였다. 현장시험 결과, 반응조에 마그네시아를 0.8% 첨가하여 2일 동안의 폭기 시 돈분 폐수 중의 암모니아(NH3)는 65%, 황화수소(H2S)는 77% 감소하였다. 반응조 안의 돈분 폐수의 초기 pH는 8.2이었고 마그네시아를 0.8%까지 넣었을 때의 pH는 9.2를 나타내었다. 이러한 경향으로 비추어 볼 때, 마그네시아가 돈분 폐수 내의 pH를 점차적으로 상승시켜 약알칼리 상태로 만든다는 것을 알 수 있었다. pH가 증가함에 따라 폐수 내에 존재하는 암모니아 가스의 일부분은 공기 중으로 기화되고, 나머지 일부는 용해되어 있는 마그네슘이온, 인산이온과 화학결합한 후 침전되어 제거된다. 기존에 가축 농가의 대부분은 돈분 폐수의 악취를 제거하여 퇴비로 만들기 위해서 미생물을 활용한 6개월간의 폭기 과정을 거쳐야 했다. 대조적으로 미생물 활동에 영향이 없는 화학적 반응을 통해서 2일 내에 돈분 폐수로부터 악취를 저감할 수 있는 효과를 현 연구를 통해 입증하였다.