• Title/Summary/Keyword: Alignment.

Search Result 4,165, Processing Time 0.03 seconds

The Effects of MAIS Strategic Alignment on Production Performance: The Consideration of AMT (생산기술 첨단화에 따른 관리회계정보시스템 전략적 연계가 생산성과에 미치는 영향)

  • Choe, Jong-Min
    • The Journal of Information Systems
    • /
    • v.26 no.2
    • /
    • pp.25-42
    • /
    • 2017
  • Purpose This study empirically examined the causal relationships among the level of advanced manufacturing technology(AMT), facilitation of alignment, the degrees of strategic alignment of management accounting information systems(MAIS), and the improvement of production performance. Design/methodology/approach Data for this study were drawn from a survey of the current status of AMT used in Korean manufacturing firms. At the beginning, 131 organizations responded to the request for information. However, during the survey, 5 firms withdrew from the survey, and as a result, 126 manufacturing firms were included in the research. In order to collect data, this study administered questionnaires with the participating firms. The survey was conducted during a 4-month period between November 2015 and March 2016. Findings The results showed that the level of AMT has a significant impact on alignment facilitation. A significant causal relationship between alignment facilitation and MAIS strategic alignment was also found. It was shown that under high degrees of MAIS strategic alignment, MAIS must provide broad-scope and integrated types of information. The causal relationships between MAIS strategic alignment and organizational performance were significant and positive. Thus, it is concluded that under high levels of AMT, a high degree of MAIS strategic alignment positively contributes to the improvement of a firm's production performance.

Optimization of Railway Alignment Using GIS (GIS를 이용한 철도선형최적화)

  • 강인준;이준석;김수성
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.727-732
    • /
    • 2002
  • This study is to develop the model of alignment optimization based on design criteria by approaching through alignment of railway design and problems in economy, environment and technology for satisfying traffic volume of the main roads caused by economical and social developments. Now, Geographic Information System isn't applied when designing a present railway in home. And the design of railway alignment is still set on importance of transition curves and cant according to passenger comfort in abroad so tile study of railway alignment is at initiation phase so far. This paper is about decision of optimal alignment between two stations such as starting point and ending point automatically using GIS in optimization of railway alignment. A route between Sungsan city and Shinpung city is the training area and the study compared and evaluated optimal railway route by GIS automatically with present railway route designed. Present optimal fomulas was used in this study for optimization of railway alignment. The model of optimization of railway alignment was developed through topographical elements and it was mentioned by the model of road alignment because of the similarity in design of alignment. But the design of lateral track irregularities, cant fur passenger comfort and motion sickness fellowed by train rolling have to be considered more. Anyway, this study farmed the basis of using GIS and the study should be keep going on in the future.

  • PDF

Development of Three D.O.F Alignment Stage for Vacuum Environment (진공용 3자유도 얼라인먼트 스테이지 개발)

  • Han, Sang-Jin;Park, Jong-Ho;Park, Hui-Jae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.11
    • /
    • pp.138-147
    • /
    • 2001
  • Alignment systems are frequently used under various semiconductor manufacturing environment. Particularly in PDP(Plasma Display Panel) manufacturing process, the alignment system is applied to the combining and sealing processes of the upper and lower glass panels of PDP, where these processes are performed in the vacuum chamber of high vacuum and high temperature. In this paper, the XYΘ-alignment stage is developed to align PDP panels. Because of high vacuum and high temperature environment, the alignment chamber has been designed to isolate the inner part of the alignment chamber from the outer environment of high vacuum and high temperature, in which every part of the alignment stage is inserted. As it is difficult to attach feedback sensors to the alignment stage in the alignment chamber, the alignment stage is implemented with the open loop algorithm, where the parallel link structure has been designed using step-motors and ball-screws for structural simplicity. The kinematic analysis is performed to drive the parallel link structure, based on the experiments of actuation-compensation of the alignment stage. For the error compensation, the hyperpatch model has been used to model the errors. From the experiments, the positional accuracy of the alignment stage can be improved significantly.

  • PDF

Experimental Sensitivity Table Method for Precision Alignment of Amon-Ra Instrument

  • Oh, Eunsong;Ahn, Ki-Beom;Kim, Sug-Whan
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.3
    • /
    • pp.241-246
    • /
    • 2014
  • The Amon-Ra instrument is the main optical payload of the proposed EARTHSHINE satellite. It consists of a visible wavelength instrument and an IR energy channel instrument to measure a global Earth albedo. We report a new sensitivity technique for efficient alignment of the visible channel instrument. Whilst the sensitivity table method has been widely used in the alignment process, the straightforward application of the method tends to produce slow process convergence because of shop floor alignment practice uncertainties. We investigated the error sources commonly associated with alignment practices and used them when estimating the Zernike polynomial coefficients. Aided with single center field wavefront error (WFE) measurements and their corresponding Zernike polynomial coefficients, the method involves the construction and use of an experimental, instead of simulated, sensitivity table to be used for alignment state estimations. A trial alignment experiment for the Amon Ra optical system was performed and the results show that 71.28 nm in rms WFE was achieved only after two alignment iterations. This tends to demonstrate its superior performance to the conventional method.

Development of Thin and Parallel XYθ Alignment Stage (박형 병렬구조 XYθ 정렬 스테이지 개발)

  • Kang, Dong-Bae;Ahn, Jung-Hwan;Son, Seong-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.74-79
    • /
    • 2011
  • Alignment systems with multi-axis motions are applied to determine vertical arrangement of multilayer assembly such as LCD, PDP, and MLCC. This study reports the development of XY${\theta}$ alignment stage which is designed as thin-type structure and parallel actuations. The thin-type parallel XY${\theta}$ alignment stage is maintained below $1{\mu}m$ in repeatability error. The squareness and straightness also allow precise motion for the alignment by the developed stage. The measured error is ${\pm}6.25{\mu}m$ in the alignment experiment by the vision system on the parallel XY${\theta}$ alignment stage.

Liquid Crystal Alignment Effects by UV Alignment Method on a Diamond-Like-Carbon Thin Film Surface (Diamond-Like-Carbon 박막표면에 UV 배향법을 이용한 액정 배향 효과)

  • Jo, Yong-Min;Hwang, Jeoung-Yeon;Hahn, Eun-Joo;Paek, Seung-Kwon;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.526-529
    • /
    • 2002
  • We studied the nematic liquid crystal (NLC) aligning capabilities by the UV alignment method on a diamond like carbon (DLC) thin film surface. A good LC alignment by UV exposure on the DLC thin film surface at $200\AA$ of layer thickness was achieved. Also, a good LC alignment by the UV alignment method on the DLC thin film surface was observed at annealing temperature of $180^{\circ}C$. However, the alignment defect of the NLC was observed above annealing temperature of $200^{\circ}C$. Consequently, the good thermal stability of LC alignment by the UV alignment method on the DLC thin film surface can be achieved.

  • PDF

Development of the Precise Multi-Position Alignment Method using a Pitch Motion (피치운동을 이용한 정밀 다위치 정렬기법 개발)

  • Lee, Jung-Shin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.708-715
    • /
    • 2010
  • In Strapdown Inertial Navigation System, alignment accuracy is the most important factor to determine the performance of navigation. However by an existing self-alignment method, it takes a long time to acquire the alignment accuracy that we want. So, to attain the desired alignment accuracy in as little as $\bigcirc$ minutes, we have developed the precise multi-position alignment method. In this paper, it is proposed a inertial measurement matching transfer alignment method among alignment methods to minimize the alignment error in a short time. It is based on a mixed velocity-DCM matching method be suitable to the operating environment of vertical launching system. The compensation methods to reduce misalign error, especially azimuth angle error incurred by measurement time-delay error and body flexure error are analyzed and evaluated with simulation. This simulation results are finally confirmed by experimentations using FMS(Flight Motion Simulator) in Lab and the integration test to follow the fire control mission.

Vertical Alignment of Liquid Crystal on Film of Plant-based Polysaccharide Derivatives

  • Yeonsu Cho;Jihyeon Moon;DaEun Yang;Hyo Kang
    • Elastomers and Composites
    • /
    • v.58 no.1
    • /
    • pp.1-10
    • /
    • 2023
  • In this study, we investigate the liquid crystal (LC) alignment of LC cells created from plant-based polysaccharide derivatives, such as guar gum. Guar gum films exhibit satisfactorily high optical transparency in the visible light region (400-750 nm). For example, the transmittance of polyimide films, which are the most typically used LC alignment layers, is 87%, whereas that of guar gum films deposited onto a glass substrate at a wavelength of 550 nm is approximately 99%. The observed LC alignment depends on the rubbing depth. For example, an LC cell comprising a guar gum film fabricated via rubbing at rubbing depths of 0.1, 0.2, 0.3, and 0.4 mm exhibits a planar LC alignment, whereas it exhibits a vertical LC alignment at a rubbing depth of 0.5 mm. Additionally, the LC alignment is shown to be correlated with the total surface energy of the guar gum films. When the total surface energy of a rubbed guar gum film exceeds 58.10 mJ/m2, an LC cell comprising the guar gum film exhibits a stable and vertical LC alignment. Therefore, guar gum can be used to realize the vertical alignment system of LC via a simple adjustment of the rubbing depth.

Stability of liquid crystal alignment to the electric field

  • Oh, Yu-mi;Im, Ji-Young;Lee, Eun-Kyu;Kim, Jong-Hyun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.834-837
    • /
    • 2006
  • We observed the destruction of the liquid crystal alignment with the repeating scan of strong DC electric field. The strong electric field seems to force the alignment to be scarred permanently and it accumulated with the repetition. In this report we connected alignment destruction behavior and electric field strength to obtain information on the alignment strength. And we compared the behavior between different alignment techniques.

  • PDF

Electron Gun Assembly;Alternative Grid Alignment Systems

  • Brantjes, Con;Zonneveld, Maarten
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.376-378
    • /
    • 2002
  • Within LG.Philips Displays electron gun assembly different grid alignment methods are used. Besides the commonly used mandrel alignment of grids (Inner Reference System, IRS), also a unique Outer Reference System (ORS) is used as grid alignment method in high-end gun assembly. This alignment method combines alignment accuracy with maximum electron optical design freedom and maximum flexibility in electron gun production.

  • PDF