• Title/Summary/Keyword: Alignment method

Search Result 1,274, Processing Time 0.027 seconds

Homeotropic Alignment Effect for Nematic liquid Crystal on the Treated $SiO_x$ Thin Film Layer by Sputtering Method (스퍼터링법으로 경사증착한 $SiO_x$ 박막 표면의 액정 수직 배향 효과)

  • Choi, Sung-Ho;Kim, Byoung-Young;Kim, Young-Hwan;Kim, Jong-Hwan;Han, Jung-Min;Hwang, Jeoung-Yeon;Oh, Byeong-Yun;Myoung, Jae-Min;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.04a
    • /
    • pp.66-67
    • /
    • 2006
  • We studied nematic liquid crystal (NLC) alignment effect on the $SiO_x$ thin film deposited $45^{\circ}$ oblique by rf magnetic sputtering system. Pretilt angle and thermal stability characteristic as well as NLC alignment effect were investigated. A uniform liquid crystal alignment effect on the $SiO_x$ thin film was achieved and pretilt angle was about $90^{\circ}$. The thermal stability of the $SiO_x$ thin film was sustained by $200^{\circ}$.

  • PDF

Electro-Optical Performances of In plane Switching(IPS) Cell on the Inorganic Thin Film by Ion Beam(IB) Method (NDLC박막에 이온빔배향법을 사용한 In Plane Switching(IPS) cell의 전기광학특성)

  • Kim, Sang-Hoon;Kim, Jong-Hwan;Kang, Dong-Hoon;Kim, Young-Hwan;Hwang, Jeoung-Yeon;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.04a
    • /
    • pp.64-65
    • /
    • 2006
  • We studied the nematic liquid crystal (NLC) alignment capability by the IB(on bean) alignment method on a NDLC(Nitrogen Diamond Like Carbon) as a-C:H thin film, and investigated electro-optical performances of the IB aligned IPS(In plane switching}cell with NDLC surface. A good LC alignment by IB exposure on a NDLC surface was achieved. Monodomain alignment of the IB aligned IPS cell can be observed. The goodelectro-optical (EO) characteristics of the IB aligned IPS cell was observed with oblique IB exposure on the NDLC as a-C:H thin film for 1 min.

  • PDF

Alignment Effect of Liquid Crystal on new organics thin film using Ultraviolet Exposure method (UV 조사법을 이용한 새로운 무기박막 표면에 액정 배향 효과)

  • Hwang, Jeoung-Yeon;Kang, Hyung-Ku;Choi, Sung-Ho;Oh, Byeong-Yun;Ham, Moon-Ho;Myoung, Jae-Min;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.62-65
    • /
    • 2005
  • We studied the nematic liquid crystal (NLC) alignment capability by the Ultraviolet (UV) alignment method on a-C:H thin-films, and investigated electro-optical performances of the UV aligned twisted nematic (TN)-liquid crystal display (LCD) with the UV exposure on a-C:H thin film surface. A good LC alignment by UV irradiation on a-C:H thin-film surfaces was achieved. Monodomain alignment of the UV aligned TN-LCD can be observed. The good electro-optical (EO) characteristics of the UV aligned TN-LCD was observed with oblique UV exposure on the a-C:H thin film surface for 1min.

  • PDF

Electro-Optical Characteristic for VA-LCD on the $SiO_x$ Thin Film Layer Oblique Deposited by Sputtering Method (스퍼터링으로 경사증착한 $SiO_x$ 박막을 이용한 VA-LCD의 전기광학특성)

  • Choi, Sung-Ho;Hwang, Jeoung-Yeon;Kim, Sung-Yeon;Oh, Byeong-Yun;Myoung, Jae-Min;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.451-452
    • /
    • 2006
  • We studied the electro-optical characteristic of vertical alignment liquid crystal display(VA-LCD) on the $SiO_x$ thin film deposited $45^{\circ}$ oblique by rf magnetic sputtering system. LC alignment characteristic showed homeotropic alignment, and pretilt angle was about $90^{\circ}$. A uniform liquid crystal alignment effect on the $SiO_x$ thin film was achieved and the electro-optical characteristic of the $SiO_x$ thin film deposited $45^{\circ}$ oblique by rf magnetic sputtering system was excellent.

  • PDF

Effects of LC Alignment by Controlling Ion-beam Energy Density (이온빔 에너지 밀도 조절에 따른 액정 배향 효과)

  • Park, Hong-Gyu;Lee, Kang-Min;Oh, Byeong-Yun;Kim, Byoung-Yong;Kang, Dong-Hun;Han, Jin-Woo;Kim, Young-Hwan;Ok, Chul-Ho;Han, Jeong-Min;Lee, Sang-Keuk;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.399-399
    • /
    • 2007
  • Recently, it is widely studied to liquid crystal (LC) alignment using ion-beam exposure. Because conventional rubbing method has some problems such as defects from dust and electrostatic charges during rubbing process. Therefore rubbing-free techniques like ion-beam method are strongly required. We studied LC alignment by controlling ion-beam energy density and electro-optical (EO) characteristics of twisted nematic LC on the polyimide surface. In this experiment, a good uniform alignment of the nematic liquid crystal (NLC) with the ion-beam exposure on the polyimide (PI) surface was observed. In addition, it can be achieved the good EO properties of the ion-beam-aligned twisted nematic liquid crystal display (TN-LCD) on PI surface.

  • PDF

Effects of Self-Traction Exercises on the Vertebral Alignment, Muscle Strength, and Flexibility of Adults in Their Twenties with Scoliosis

  • Kim, Yongmin;Jeon, Changkeun;Yoo, Kyoungtae
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.10 no.2
    • /
    • pp.1810-1817
    • /
    • 2019
  • Background: Effect of cervical and lumbar tractions on the reduction in the angle of curvature and the effect of a correction exercise or a general traction method on balance, muscle strength, pain, and body alignment, however insufficient research has been undertaken on self traction exercises targeting patients with scoliosis. Purpose: To determine the effect of cervical and lumbar tractions on the reduction in the angle of curvature and the effect of a correction exercise or a general traction method on balance, muscle strength, pain, and body alignment. Design: Randomized controlled clinical trial (single blinded) Methods: Twelve adults(20s) with scoliosis were included in this study and performed a traction program that was composed of a 5-min warm-up exercise, a 15-min main exercise, and a 5-min cool-down exercise (25 minutes in total), three times a week for four weeks. The Chiro traction machine was used for the self-traction exercise. Vertebral alignment, muscle strength, and flexibility were compared before and after the intervention using the paired T-test. Results: The scoliosis angle, pelvic torsion, and lumbar extensor were significantly changed by intervention; however, there was no significant difference in flexibility. Conclusion: The results revealed that self-traction exercise activated blood flow through the extension and contraction of muscles, effectively increasing the function of the muscles around the vertebrae.

Measurement and Correction of PCB Alignment Error for Screen Printer Using Machine Vision (1) (머신비전을 이용한 PCB 스크린인쇄기의 정렬오차측정 및 위치보정 (1))

  • 신동원
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.6
    • /
    • pp.88-95
    • /
    • 2003
  • This paper presents the measurement and correction method of PCB alignment errors for PCB screen printer. Electronic equipment is getting smaller and yet must satisfy high performance standard. Therefore, there is a great demand for PCB with high density. However conventional PCB screen printer doesn't have enough accuracy to accommodate the demand fur high-resolution circuit pattern and high-density mounting capacity of electronic chips. It is because the alignment errors of PCB occur when it is loaded to the screen printer. Therefore, this study focuses on the development of the system which is able to measure and correct alignment errors with high-accuracy. An automatic optical inspection part measures the PCB alignment errors using machine vision, and the high-accuracy 3-axis stage makes correction for these errors. This system used two CCD cameras to get images of two fiducial marks of PCB. The geometrical relationship between PCB, cameras, and xy$\theta$ stage is derived, and analytical equations for alignment errors are also obtained. The unknown parameters including camera declining angles and etc. can be obtained by initialization process. Finally, the proposed algorithm is verified by experiments by using test bench.

Liquid Crystal Orientation Properties on Homogeneous Polymer Surface by Various Alignment Methods

  • Kim, Young-Hwan;Lee, Kang-Min;Kim, Byoung-Yong;Oh, Byeong-Yun;Han, Jeong-Min;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.1
    • /
    • pp.16-19
    • /
    • 2009
  • We have studied the liquid crystal alignment properties for various alignment methods on the homogeneous polyimide surface. Suitable liquid crystal alignment for one-side alignment cell on the polyimide surface by all alignment method was observed. Highly pre-tilt angle of the NLC for both-side rubbing cell was measured. But, low pre-tilt angle of the NLC for one-side ion beam and UV irradiation cell was observed. We consider that the pre-tilt angle of NLC for one-side ion beam and UV irradiation on the PI surface is lower than that of the PI surface with rubbing. Also, the suitable transmittance-voltage curves for the one-side rubbing TN-LCD on the PI surface with one-side UV irradiation were measured. Also, good response time characteristics of the one-side rubbing TN-LCD on the polyimide surface with one-side UV irradiation can be measured.

Development of Solution Algorithm for Multi-dimention Road Alignment Design Considering Low-Carbon (탄소저감형 다차원 도로선형설계를 위한 솔루션 알고리즘 개발)

  • Kang, Jeon-Yong;Shim, chang-su
    • Journal of KIBIM
    • /
    • v.5 no.4
    • /
    • pp.11-22
    • /
    • 2015
  • Government efforts for green growth policy initiatives demand low-carbon technologies in the road construction industry. The purpose of this paper is to develop an algorithm of a road alignment design solution for establishing the multi-dimensional information, and to calculate carbon emission quantity due to the geometric design elements in the planning phase of road alignment. The paper developed a calculation method for carbon emission quantity by drawing a speed profile reflected in the operating speed, acceleration and deceleration, which are majors factor of carbon emissions while driving and by applying a carbon emission factor. From this effort, it enabled alignment planning to reduce carbon emission. Object-based parametric design methods of the cross-sections were proposed for alignment planning, and the paper demonstrated a BIM-based road alignment planning solution. The proposed solutions can provide multi-dimensional information on carbon emission quantity and cross section elements through driving simulation. It is expected to allow construction of eco-friendly roads by deriving optimal road alignment to minimize environmental costs.

Effects of Three Week 3D Pilates Breathing Exercise on Spinal Curvature, Trunk Imbalance and Alignment of Healthy Adults

  • Kim, Seongyeol
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.10 no.2
    • /
    • pp.1797-1802
    • /
    • 2019
  • Background: Breathing is the essential step of Pilates exercise and can be used to activate core muscles. Although the effects of breathing exercise on pain, breathing muscles, and cervical posture have been extensively studied, little is known about the impact of Pilates breathing on spinal posture and alignment. Purpose: To determine the effect of 3D-Pilates breathing exercise on spinal curvature and alignment of healthy adults during corrected to normal alignment. Design: One group pre-post test design Methods: Eighteen participants were given a 3D-pilates breathing exercise twice a week (20 minutes per session) for three weeks and warmed up for 10 minutes before each exercise session. To examine spinal curvature and alignment of each subject, this study used radiation free rasterstereography (Formetric III, Germany). Paired t-test and Wilcoxon signed rank test were performed to determine the difference between pre and post exercise. Results: There were statistically significant differences in height (p<.001), kyphosis angle (p<.05), trunk imbalance (p<.05), kyphotic apex (p<.01), cervical fleche (p<.05), pelvic tilt (p<.01), and lateral deviation (p<.05) between before and after 3D Pilates breathing exercise. However, there was no significant difference in lordosis angle. Conclusions: The study results indicated that three week 3D-pilates breathing exercise program could be presented as an effective rehabilitation method for improving spinal curvature and alignment.