• Title/Summary/Keyword: Alignment degree

Search Result 197, Processing Time 0.03 seconds

Accuracy of bite registration according to the buccal bite scan range of intra-oral scanner (구강 스캐너의 협측 교합 스캔 부위에 따른 교합 인기의 정확도)

  • Tae-sung Kwon;Dae-hyun Kim;Min-su Kim;Dong-jun Song;Joo-Hun Song
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.3
    • /
    • pp.125-134
    • /
    • 2024
  • Purpose: The aim of this study was to determine which scan range would provide the most accurate bite registration when performing a bite scan after scanning an upper and lower arch using an intraoral scanner. Materials and Methods: The occlusal contact points were recorded using articulating paper for 30 adults, and the results of various ranges of buccal bite scan were compared based on this. Buccal bite scan of 5 ranges (1st premolar to 2nd premolar, 1st premolar to 1st molar, 1st premolar to 2nd molar, 2nd premolar to 1st molar, and canines to another side canine of the maxillary teeth) was performed, and then the buccal bite scan file was used in a CAD program to confirm the occlusal area in the scan file through data editing and alignment, leaving the buccal area of the teeth. Afterwards, the degree of agreement between the occlusal contact points obtained from the articulating paper and the occlusal area obtained from the scan file was compared, and statistical analysis was performed using the homoscedastic T-test (α = 0.05). Results: The alignment success and alignment failure rates among each group were 77.23% and 40.85% in canine to another side canine, 68.23% and 28.89% in bilateral first premolar to second premolar, 63.76% and 29.97% in bilateral first premolar to first molar, 61.31% and 32.04% in bilateral first premolar to second molar, 67.55% and 27.46% in second premolar to first molar. The results of the anterior scan of both canines showed higher alignment success and failure rates compared to the scan results of all maxillary posterior teeth. In the alignment success rate, statistical significance was not found depending on the scan range of the posterior teeth, but in comparing the results of the posterior teeth and both canines, statistical significance was observed except for the scan results of the second premolar to the first molar. There was no statistical significance in the alignment failure rate depending on the scan range of the posterior teeth, and statistical significance was observed in the results of the posterior teeth and both canines. Conclusion: When taking a buccal bite scan, in the case of scanning the anterior teeth, more occlusal area appear than when scanning the posterior teeth, and in the case of scanning the posterior teeth, there is no significant difference in the bite registration depending on the scan range.

The study on the manufacturing intermediary materials for the carbon nanofiber reinforced Cu matrix noncomposite (일방향 탄소나노섬유 강화 Cu 기지 나노복합재료용 중간재 제조에 관한 연구)

  • 백영민;이상관;엄문광
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.10a
    • /
    • pp.46-49
    • /
    • 2003
  • Cu have been widely used as signal transmission materials for electrical electronic components owing to its high electrical conductivity. However, it's size have been limited to small ones due to its poor mechanical properties, Until now, strengthening of the copper at toy was obtained either by the solid solution and precipitation hardening by adding alloy elements or the work hardening by deformation process. Adding the at toy elements lead to reduction of electrical conductivity. In this aspect, if carbon nanofiber is used as reinforcement which have outstanding mechanical strength and electric conductivity, it is possible to develope Cu matrix nanocomposite having almost no loss of electric conductivity. It is expected to be innovative in electric conduct ing material market. The unidirectional alignment of carbon nanofiber is the most challenging task developing the copper matrix composites of high strength and electric conductivity In this study, the unidirectional alignment of carbon nanofibers which is used reinforced material are controlled by drawing process in order to manufacture the intermediary materials for the carbon nanofiber reinforced Cu matrix nanocomposite and align mechanism as well as optimized drawing process parameters are verified via experiments and numerical analysis. The materials used in this study were pure copper and the nanofibers of 150nm in diameter and of $10~20\mu\textrm{m}$ In length. The materials have been tested and the tensile strength was 75MPa with the elongation of 44% for the copper it is assumed that carbon nanofiber behave like porous elasto-plastic materials. Compaction test was conducted to obtain constitutive properties of carbon nanofiber. Optimal parameter for drawing process was obtained by experiments and numerical analysis considering the various drawing angles, reduction areas, friction coefficient, etc Lower reduction areas provides the less rupture of cu tube is not iced during the drawing process. Optimal die angle was between 5 degree and 12 degree. Relative density of carbon nanofiber embedded in the copper tube is higher as drawing diameter decrease and compressive residual stress is occurred in the copper tube. Carbon nanofibers are moved to the reverse drawing direct ion via shear force caused by deformation of the copper tube and alined to the drawing direction.

  • PDF

The Explicitly Quasi-linear Relation Between the Order Parameter and Normalized Birefringence of Aligned Uniaxially Anisotropic Molecules Determined Using a Numerical Method (수치해석적인 방법으로 규명한 정렬된 단축이방성 분자들의 질서변수와 상대 복굴절의 준선형 관계식)

  • Kim, Sang Youl
    • Korean Journal of Optics and Photonics
    • /
    • v.27 no.6
    • /
    • pp.223-228
    • /
    • 2016
  • The birefringence of distributed, uniaxially anisotropic molecules like liquid crystals is calculated as the degree of ordering is varied. The relation between the normalized birefringence ${\Delta}n_{rel}$ and the orientational order parameter S is investigated. The distribution function, which enables one to monitor the degree of ordering of liquid crystals including randomly distributed ones, is introduced. Using this distribution function, a series of distributed liquid crystals with order parameters ranging from 0 to 1 are generated, and ${\Delta}n_{rel}$ and S of the correspondingly distributed liquid crystals are calculated. Based on the calculated data, it is revealed that ${\Delta}n_{rel}$ and S satisfy the quasi-linear relation of $S=(1+a){\Delta}n_{rel}-a{\Delta}n^2_{rel}$, where a can be approximated as $n_o{\frac{{\Delta}n}{4}}$. The anisotropy of molecular polarizability is also calculated, using the birefringence, and separately following Vuks' method and Neugebauer's method, and it is shown that the relations between S and the molecular-polarizability anisotropy are also quasi-linear.

The Effect of Abdominal Breathing Exercises on Menstrual Pain (복식호흡 운동이 월경통에 미치는 영향)

  • Pyo, Jeong-Soo;Min, Ju-Hwa;Lee, Dong-Gun;Goo, Bong-Oh
    • PNF and Movement
    • /
    • v.13 no.2
    • /
    • pp.103-109
    • /
    • 2015
  • Purpose: Abdominal breathing exercises are recommended to activate the breathing muscles and the pelvic floor muscles, as well as to increase postural alignment during exhalation. The purpose of this study was to clarify the effect of improving abdominal muscle strength on menstrual pain in women in their twenties using abdominal breathing exercises. Method: In this study, 32 female university students were included as the subjects. The subjects were divided into two groups based on the area of menstrual pain: lumbar pain (n=16) and lower abdomen pain (n=16). The abdominal breathing positions were divided into two positions, which included a hook lying position and hip and knee flexions at $90^{\circ}$ in the supine position. Exercises were used to strengthen the abdominal muscles during exhalation. Four sets of the exercises were completed three times a week over the course of eight weeks. The degree of pain was measured using the Numeric Rating Scale (NRS). Muscle thickness was measured using an ultrasound. Result: The thickness of the transverse abdominis (TrA) and internal oblique (IO) increased in the lower abdomen pain group. However, thickness of the external oblique (EO) did not increased following abdominal breathing. No significant difference in posture was identified in the lower abdomen group. TrA thickness increased significantly in the lumbar pain group. However, thickness did not increase significantly in the lumbar pain group. In addition, the lumbar pain group experienced no significant effects on posture. IO thickness increased following hip and knee flexions at $90^{\circ}$ in the lumbar pain group. Menstrual pain decreased following intervention in both groups. There was no significant difference in the degree of pain reduction between both groups. Conclusion: As examples of alternative medicine, abdominal breathing exercises may be effective in decreasing menstrual pain.

Preparation of Optically Anisotropic Film by Sunset Yellow Chromonic Liquid Crystal (Sunset Yellow 액정 색소를 이용한 광학적 이방성 필름 제조)

  • Kim, Byungchul;Chang, Eugene;Shin, Seunghan
    • Applied Chemistry for Engineering
    • /
    • v.22 no.1
    • /
    • pp.81-86
    • /
    • 2011
  • The aqueous solution of Sunset Yellow-FCF (SY-FCF) began to show schlieren texture at room temperature when its concentration reaches 25 wt%. A further increase of the concentration of SY-FCF to 28 wt% resulted in a perfect nematic liquid crystal phase. However, more than 30 wt% of SY-FCF in aqueous solution was required to make an optically anisotropic film simply by shear coating. In our study, concentration of SY-FCF solution, coating speed, drying temperature, and relative humidity were considered as coating parameters affecting the preparation of optically anisotropic thin films. From analysis of variance analysis (ANOVA), the solution concentration was revealed as a main factor affecting the film thickness. The drying temperature and solution concentration were main factors affecting the transmittance of parallel direction ($T_o$). Especially, SY-FCF aqueous solution with high concentration induced a better alignment of LC columns and produced highly oriented anisotropic films. In this study, optically anisotropic films prepared by 33 wt% of SY-FCF in aqueous solution showed 89.7~98.7% of degree of polarization.

Effect of angulation on the 3D trueness of conventional and digital implant impressions for multi-unit restorations

  • Ozay Onoral;Sevcan Kurtulmus-Yilmaz;Dilem Toksoy;Oguz Ozan
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.6
    • /
    • pp.290-301
    • /
    • 2023
  • PURPOSE. The study aimed to determine the influence of implant angulation on the trueness of multi-unit implant impressions taken through different techniques and strategies. MATERIALS AND METHODS. As reference models, three partially edentulous mandibular models (Model 1: No angulation; Model 2: No angulation for #33, 15-degree distal angulation for #35 and #37; Model 3: No angulation for #33, 25-degree distal angulation for #35 and #37) were created by modifying the angulations of implant analogues. Using a lab scanner, these reference models were scanned. The obtained data were preserved and utilized as virtual references. Three intraoral scanning (IOS) strategies: IOS-Omnicam, ISO-Quadrant, and IOS-Consecutive, as well as two traaditional techniques: splinted open tray (OT) and closed tray (CT), were used to create impressions from each reference model. The best-fit alignment approach was used to sequentially superimpose the reference and test scan data. Computations and statistical analysis of angular (AD), linear (LD), and 3D deviations (RMS) were performed. RESULTS. Model type, impression technique, as well as interaction factor, all demonstrated a significant influence on AD and LD values for all implant locations (P < .05). The Model 1 and SOT techniques displayed the lowest mean AD and LD values across all implant locations. When considering interaction factors, CT-Model 3 and SOT-Model 1 exhibited the highest and lowest mean AD and LD values, respectively. Model type, impression technique, and interaction factor all revealed significant effects on RMS values (P ≤ .001). CT-Model 3 and SOT-Model 1 presented the highest and lowest mean RMS values, respectively. CONCLUSION. Splinted-OT and IOS-Omnicam are recommended for multi-unit implant impressions to enhance trueness, potentially benefiting subsequent manufacturing stages.

Treatment of Distal Tibia Fracture using MIPPO Technique with Locking Compression Plate: Comparative Study of the Intraarticular Fracture and Extraarticular Fracture (잠김-압박 금속판을 사용하여 MIPPO 수기를 적용한 원위부 경골 골절의 치료: 관절내 골절과 관절외 골절의 비교)

  • Chung, Soo-Tae;Kim, Hyung-Soo;Cha, Seung-Do;Yoo, Jeong-Hyun;Park, Jai-Hyung;Kim, Joo-Hak;Jung, Jin-Ha
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.2
    • /
    • pp.162-168
    • /
    • 2009
  • Purpose: To evaluate the efficiency of the minimally invasive percutaneous plate osteosynthesis (MIPPO) with locking compression plate (LCP) for distal tibial metaphyseal intra-articular fracture compared with extra-articular fracture. Materials and Methods: From February 2006 to June 2008, 21 patients with distal tibia metaphyseal intra-articular fracture and 20 patients with extra-articular fracture were treated operatively by MIPPO technique with LCP and followed for at least one year. In the group with intra-articular fracture, mean age was 48.85 years old and a mean follow-up was 15 months. In the other group with extra-articular fracture, mean age was 52.35 years old and a mean follow-up was 14.5 months. The type of fracture was evaluated using the AO/OTA classification and open-fractures were according to the Gustilo-And gron classification. Radiologic evaluation with fracture healing and tibial alignment, clinical evaluation with Olerud and Molander ankle score and restriction of motion were done for treatment. Results: According to AO/OTA classification, There were 21 type A, 15 type B, 5 type C. Average union time of the intra-articular fracture (type B, C) was 18.7 weeks. Average union time of the extra-articular fracture (type A) was 17.1 weeks. All fractures were healed without malunion. There were no difference of mean restriction angle between intra-articular fracture (ankle dorsiflexion was 3.57 degree, plantar-flexion was 5.95 degree) and extra-articular fracture (ankle dorsiflexion was 3 degree, plantar-flexion was 3.75 degree). There were no difference of Olerud and Molander ankle score between them as a mean score of intra-articular and extra-articular was 89.25, 91.25 each other. As a complication, there were 3 case of skin necrosis, 8 case of discomfortable skin tenting by plate and 1 superficial infection, but could be healed by conservative care. Conclusion: MIPPO technique, combined articular reduction, with LCP of distal tibial metaphyseal fracture was a good method with high functional recovery.

  • PDF

Characteristics of $Al_2O_3$ Short Fiber/Al-Si-Mg Alloy Composites Fabricated by Rheo-compocasting and Hot Extrusion (Rheo-compocasting 및 열간압출에 의하여 제조한 Al-Si-Mg / $Al_2O_3$단섬유강화복합재료의 특성)

  • Lee, Hag-Ju;Hong, Chun-Pyo
    • Journal of Korea Foundry Society
    • /
    • v.11 no.4
    • /
    • pp.293-302
    • /
    • 1991
  • Aluminum alloy matrix composites reinforced with various amounts of $Al_2O_3$ short fibers have been produced by a combined technique of rheo-compocasting and hot extrusion. Distribution of fibers in the composites fabricated by rheo-compocasting was relatively uniform. A good degree of uniaxial fiber alignment has been achieved by hot extrusion, but a lot of fibers fractured during extrusion. The tendency of fiber fracturing increases as the aspect ratio and the amount of fibers increase. Relatively good bonding between fiber and matrix was obtained by the formation of $MgAl_2O_4$ and Mg(Al, Fe)$_2O_4$ at the interface between fiber and matrix. In extruded composites, fiber-strengthening effect was relatively small since a lot of fibers fractured during hot extrusion. On the other hand, dispersion strengthening effect may increase. In order to improve the fiber strengthening effect, it is important to optimize the extrusion condition with consideration of metal flow in extrusion die.

  • PDF

The effect of the spinning conditions on the structure of mesophase pitch-based carbon fibers by Taguchi method

  • Jiang, Zhao;Ouyang, Ting;Yao, Xiangdong;Fei, Youqing
    • Carbon letters
    • /
    • v.19
    • /
    • pp.89-98
    • /
    • 2016
  • Taguchi’s experimental design was employed in the melt spinning of molten mesophase pitch to produce carbon fibers. The textures of the obtained carbon fibers were radial with varied crack angles, as observed by scanning electron microscopy and polarized optical imaging. The diameter, crack angle, preferred orientation, and tensile modulus of the produced samples were examined to investigate the influence of four spinning variables. The relative importance of the variables has been emphasized for each characteristic. The results show that thicker carbon fiber can be obtained with a smaller entry angle, a higher spinning temperature, a reduced winding speed, and an increased extrusion pressure. The winding speed was found to be the most significant factor in relation to the fiber diameter. While it was observed that thicker carbon fiber generally shows improved preferred orientation, the most important variable affecting the preferred orientation was found to be the entry angle. As the entry angle decreased from 120° to 60°, the shear flow was enhanced to induce more ordered radial alignment of crystallite planes so as to obtain carbon fibers with a higher degree of preferred orientation. As a consequence, the crack angle was increased, and the tensile modulus was improved.

A Development of the Operating Speed Estimation Model of Truck on Four-lane Rural Highway (지방부 일반국도 4차로의 화물차 주행속도 예측모형 개발)

  • Park, Min Ho;Lee, Geun Hee
    • International Journal of Highway Engineering
    • /
    • v.16 no.5
    • /
    • pp.173-182
    • /
    • 2014
  • PURPOSES : The purpose of the study is to a) explore the operating speed of trucks on rural highways affected by road geometry, and thereby b) develop a predictive model for the operating speed of trucks on rural highways. METHODS : Considering that most of the existing studies have focused on cars, the current study aimed to predict the operating speed of trucks by conducting linear regression analysis on the speed data of trucks operating on the linear-curved-linear portions of the road as a single set. RESULTS : The operating speed in the plane curve portion increased with the length of the curve, and decreased with a lower vertical grade and a smaller curve radius. In the straight plane portion, the operating speed increased with a larger curve radius(upstream), and decreased with an increase in the change of the vertical grade, depending on the length of the vertical curve. CONCLUSIONS : This study developed estimation models of truck for operational speed and evaluated the degree of safety for horizontal and vertical alignments simultaneous. In order to represent whole area of the rural highway, the models should be ew-analyzed with vast data related with road alignment factor in the near future.