Journal of the Korean Academy of Esthetic Dentistry
/
v.30
no.1
/
pp.13-23
/
2021
These days, Clear aligners occupy an important position in dentistry, and have increased in popularity and in the market share of orthodontic treatment system. Currently, the world's No. 1 company occupies a significant portion of the global clear aligner market, and many latecomers are trying to follow. Serafin clear aligner system, which is one of domestic clear aligner systems pursues comprehensive orthodontic treatment, not just target tooth movement. Here I report two orthodontic treatment cases using Serafin clear aligner system.
AFM tip has been used for surface profiling with a fine resolution, but there is a barrier to improve its performance because of the low aspect ratio. Many researchers have solved this problem with attaching carbon nanotube (CNT) to Si-tip. In this paper, we proposed the aligner system that composed of dual type stage system, and these stages could attach a carbon nanotube to tungsten-tip in vacuum condition. We used tungsten tip instead of Si-tip because of its conductivity. The aligner system proposed in this paper has 10 degree-of-freedom that 3 in the first stage and 7 in the second stage. With picomotors and piezotube, the first stage has the resolution about several tens of nm and the second stage has a resolution about a nm. We experimented on characterization of Nano Aligner System and operated picomotors in SEM environment.
This paper presents a development of vision aligner with three channels for the wafer and plate bonding machine in manufacturing of LED. The developed vision aligner consists of three cameras and performs wafer alignment of rotation and translation, flipped wafer detection, and UV Tape detection on the target wafer and plate. Normally the process step of wafer bonding is not defined by standards in semiconductor's manufacturing which steps are used depends on the wafer types so, a lot of processing steps has many unexpected problems by the workers and environment of manufacturing such as the above mentioned. For the mass production, the machine operation related to production time and worker's safety so the operation process should be operated at one time with considering of unexpected problem. The developed system solved the 4 kinds of unexpected problems and it will apply on the massproduction environment.
Proceedings of the Korean Society of Precision Engineering Conference
/
2002.10a
/
pp.536-539
/
2002
In this paper, we developed the automatic optical fiber aligner by image processing and automatic loading system. Optical fiber is indispensable for optical communication systems that transmit large volumes of data at high speed, but super-precision technology in sub-micron units is required for optical axis adjustment, we have developed 6-axis micro stage system for I/O optical fiber arrays, the initial automatic aligning system/software for a input optical array by the image processing technique, fast I/O-synchronous aligning strategy, the automatic loading/unloading system and the automatic UV bonding mechanism. In order to adjust the alignment it used on PC based motion controller, a $10\mu\textrm{mm}$ repeat-detailed drawing of automatic loading system is developed by a primary line up for high detailed drawing. Also, at this researches used the image processing system and algorithm instead of the existing a primary hand-line up. and fiber input array and waveguide chip formed in line by automatic. Therefore, the developed and manufactured optical aligning system in this research fulfills the great role of support industry for major electronics manufacturers, telecommunications companies, universities, government agencies and other research institutions.
The introduction of smart technology provides accuracy, safety, and efficiency to both physicians and patients. Although interest in a clear aligner is increasing among users worldwide, the current clear aligner requires a visit to the hospital every one or two weeks for replacement, which is a very cumbersome process. There is also confusion among dentists and patients because about 40 to 80 devices are made, and calibration is done based on the order and duration of the clear aligner. Therefore, this study designed and developed a clear aligner management system so that communication between the patient and dentist can be smoothly performed by inserting the QR code into the transparent correction device. As a result, the size of the QR code was recognized as $6{\ast}6mm^2$ which can be used in the oral and the recognition distance was 100% within 12 cm. Since the dentist can remotely manage the patient with the proposed system and improve the correction effect, it is possible to manage patients abroad, as well as domestically.
Optical fiber is indispensable for optical communication systems that transmit large volumes of data at high speed, but super precision technology in sub-micron units is required for optical axis adjustment. We developed the automatic optical fiber by image processing and automatic loading system. we have developed 6-axis micro stage system for I/O optical fiber arrays, the initial automatic aligning system software for a input optical array by the image processing technique, fast I/O-synchronous aligning strategy, the automatic loading/unloading system and the automatic UV bonding mechanism. In order to adjust the alignment it used on PC based motion controller, a $10{\mu}m$ repeat-detailed drawing of automatic loading system is developed by a primary line up for high detailed drawing. Also, at this researches used the image processing system and algorithm instead of the existing a primary hand-line up and fiber input array and waveguide chip formed in line by automatic.
Journal of the Korean Academy of Esthetic Dentistry
/
v.31
no.1
/
pp.11-18
/
2022
Adult patients who need implant and prosthodontic treatment often need treatment to improve the existing occlusion through orthodontic treatment for long-term stable treatment results. However, due to non-aesthetic and uncomfortable orthodontic treatment with orthodontic brackets and wires, many adult patients give up treatment even though they know the need for it. Recently, as digital dentistry has affected all areas of dentistry, clear aligner orthodontic systems have begun to be widely used, and their use is increasing in adults and old-aged people due to the esthetic advantage and convenient oral care. SERAFIN clear aligner system developed in Korea has been developed with the aim of implementing a functional occlusion harmony and is used not only for partial orthodontic treatment but also comprehensive orthodontic treatment. This patient presentation is shown the treatment using SERAFIN clear aligner system for the treatment of patient with TMD, severe extrusion of maxillary second molars, and extracted teeth.
Journal of the Korean Institute of Telematics and Electronics S
/
v.34S
no.12
/
pp.10-18
/
1997
The parallel trabutary signals in the SDH-based transmission system have the frame phase skew due to uneven transmission delays in the data and the clock path. This phase skew must be eliminated prior to synchronously multiplexing process. A new twenty-four channel, 51.84Mb/s DFPA(Digital Frame Phase Aligner) has been designed and fabricated in 0.8.mu.m CMOS gate array. This unique device phase-aligns the skewed input signals with refernce frame synchronous signal and reference clok for subsequent synchronous multiplexing process. the performance of fabricated device is evaluated by the STM-16 transmission system and DS-3 meansurement set. The frame phase margin of +2/-3 bit periods has been demonstrated.
Journal of Institute of Control, Robotics and Systems
/
v.8
no.9
/
pp.812-817
/
2002
This paper presents a development of high accuracy aligner and describes a method to find the orientation of a substantially circular disk shaped wafer with at least one flat region on an edge thereof. In the developed system, the wafer is spun one 360 degree turn on a chuck and the edge position is measured by a linear array to obtain a set of data points at various wafer orientation. The rotation axis may differ from wafer center by an unknown eccentricity. The flat angle is found by fitting a cosine curve to the actual data to obtain a deviation. The maximum deviation is then corrected for errors due to a finite number of data points and wafer eccentricity by calculating an adjustment angle from data points on the wafer fiat. After determining the flat angle the wafer is spun to the desired orientation. The wafer eccentricity can be calculated from four of the data points located away from the flat edge region. and the wafer is then centered.
Recent technological advance have greatly expanded the application of invisible orthodontic treatment using clear thermoplastic materials. However, the final outcomes using clear aligner system do not achieve the level of final goal frequently, which results in case refinement, midcourse correction, or fixed orthodontic treatment. Therefore, mechanical properties of thermoplastic materials should be considered to improve the quality of outcomes. The purposes of this special article were to evaluate the force and stress depending on the materials, deflection and thickness of thermoplastic materials and to evaluate the mechanical properties of thermoplastic materials after repeated loading. Thickness and amount of deflection rather than products and materials showed the largest effect on force and stress. In all products, at least 159 gf of force was required for more than 1.0 mm deflection or when materials with 1.0 mm thickness were deflected. Orthodontic forces delivered by thermoplastic materials depend on the materials, thickness, amount of activation, and intra-oral condition. Proper thickness of thermoplastic materials and deflection level of tooth movement should be decided for the efficient and physiologic tooth movement.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.