• Title/Summary/Keyword: Aliasing artifacts

Search Result 23, Processing Time 0.02 seconds

Color Image Restoration in Detected Aliasing Region (에일리어싱 영역 검출을 통한 컬러 영상 복원)

  • Kwon, Ji Yong;Kang, Moon Gi
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.105-110
    • /
    • 2016
  • To reduce the cost and volume of a digital camera, a subsampled color filter array(CFA) image is used and demosaicking is applied to estimate the missing color values. However, aliasing, the overlaps of signals in the frequency domain, occurs when signals are subsampled. This causes aliasing artifacts such as false colors and zipper effects in demosaicking processes. In this paper, the algorithm estimating high-quality color images by removing aliasing artifacts in them is proposed. The aliasing region map is estimated using the sub-sampled signals of the CFA image. By using the aliasing region map and the estimated luminance image, the least squares problem of the observation models is designed and aliasing artifacts are eliminated. The experiments demonstrate that the proposed algorithm restores color images without aliasing artifacts.

Temporal Anti-aliasing of a Stereoscopic 3D Video

  • Kim, Wook-Joong;Kim, Seong-Dae;Hur, Nam-Ho;Kim, Jin-Woong
    • ETRI Journal
    • /
    • v.31 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • Frequency domain analysis is a fundamental procedure for understanding the characteristics of visual data. Several studies have been conducted with 2D videos, but analysis of stereoscopic 3D videos is rarely carried out. In this paper, we derive the Fourier transform of a simplified 3D video signal and analyze how a 3D video is influenced by disparity and motion in terms of temporal aliasing. It is already known that object motion affects temporal frequency characteristics of a time-varying image sequence. In our analysis, we show that a 3D video is influenced not only by motion but also by disparity. Based on this conclusion, we present a temporal anti-aliasing filter for a 3D video. Since the human process of depth perception mainly determines the quality of a reproduced 3D image, 2D image processing techniques are not directly applicable to 3D images. The analysis presented in this paper will be useful for reducing undesirable visual artifacts in 3D video as well as for assisting the development of relevant technologies.

  • PDF

MRI Artifacts and Reducing Techniques

  • 강해진
    • Proceedings of the KSMRM Conference
    • /
    • 1999.04a
    • /
    • pp.34-42
    • /
    • 1999
  • 의료영상에서 인공물(Artifacts) 이라 함은 영상이 얻어지는 신체부위와 아무런 관련이 없으나 얻어진 영상에는 마치 영상의 일부분으로 나타나는 모든 것을 가리킨다. 따라서 영상에서 이들 인공물들은 실제 조직의 해부학적인 구조를 나타내지 않으므로 영상 판독에 영향을 주어 잘못된 진단을 초래할 수도 있다. 그러나 MR 영상이 가능한 이래로 새로운 여러 종류의 MR 인공물들이 많이 발견 되었으나 다행스럽게도 거의 모든 MR 인공물들은 쉽게 설명이 가능하며, 따라서 이들 인공물들에 의한 진단 오류의 가능성은 매우 희박한 실정이다. 그러나 새로운 영상방법이나 혹은 새로운 펄스대열이 계속 고안됨에 따라 새로운 종류의 인 공물들이 생겨날 가능성은 항상 존재하고 있다. 지금까지 알려진 여러 MR 인공물들은 그 생겨난 원인에 따라 다음과 같이 크게 세 가지로 분류가 가능하다. I. Motion Artifacts 1. Voluntary motion 2. Involuntary motion 1) Bowel Peristalsis 2) Respiration 3) Cardiac and vessel pulsation 4) Swallowing 3. Fluid motion 1) Blood flow 2) Cerebrospinal fluid flow II. Reconstruction Artifacts 1. Aliasing 2. Partial volume averaging 3. Truncation (Ringing) 4. Central point III. Magnetic and RF Field Related Artifacts 1. Chemical shift 1) First kind 2) Second kind 2. Susceptibility 1) Dental 2) Metal 3. Magic angle 4. Zipper 5. Bad data point 6. RF field inhomogeneity 7. Magnetic field inhomogeneity 8. Eddy current 9. slice overlapping 10. Zebra 11. RF overflow

  • PDF

Artifacts Improvement by using the Echo Planar Imaging and Pre-Saturation Pulse Band techniques of Reduced Field-Of-View in Breast Magnetic Resonance Imaging Examination (유방 자기공명영상검사에서 감소된 영상영역의 에코평면영상기법과 사전포화기법 사용에 의한 인공물 개선)

  • Lee, Jaeheun;Kim, Hyunjin;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.307-314
    • /
    • 2015
  • This study was conducted in reducing the involuntary motion artifacts because of lungs and heart movements as well as the aliasing artifacts generated during the use of the reduced-FOV EPI technique while performing breast MRI. Performed on a total of 38 obesity female subjects who visited the clinic for pre-examination before surgery within the period from August 1 to November 30, 2014. The 3.0T MRI scanner equipped with a breast scanning coil. Qualitative and quantitative analyses were each used for the evaluation of the acquired images while an Paired T-test and Wilcoxon rank test were performed to check the statistical significance. The variation ratio rose by 15.69% with the additional application of a pre-saturation pulse in the lesion, by 13.72% near the lesion, and 20.63% in the fat and the contrast-to-noise ratio rose by 10.58% in and near the lesion and by 12.03% in the lesion and fat, respectively. there were increases of 22.05% and 21.42% at 0 and 1000 respectively in qulitative evaluation and growth of 16.10% in apparent diffusion coefficient. it showed a statistically significant result(p<0.05) in signal to noise ratio, contrast to noise ratio, diffusion slope coefficient and apparent diffusion coefficient. The involuntary movements artifacts that occur in the phase encoding direction and the aliasing artifacts are considered to be reduced to obtain the best image in the additional use of the pre-saturation pulse as DWI is acquired.

Edge-Adaptive Color Interpolation for CCD Image Sensor

  • Heo, Bong-Su;Hong, Hun-Seop;Gang, Mun-Gi
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • The color interpolation scheme can play an important role in overcoming the physical limitation of the CCD image sensor and in increasing the resolution of color signals, while most conventional approaches result in blurred edges and false color artifacts. In this paper, we have proposed an improved edge-adaptive color interpolation scheme for a progressive scan CCD image sensor with RGB color filter array The edge indicator function proposed utilizes not only the within-channel correlation but also the cross-channel correlation, and reflects the edge characteristics of an image adaptively. The color components unavailable for at each channel are interpolated along the edge direction, not across the edges, so that aliasing artifacts are supressed. Furthermore, we eliminated false color artifacts resulting from the color image formation model in the edge-adaptive color interpolation scheme by adopting the switching algorithm based on the color edge detection. Simulation results of the proposed algorithm indicate that the improved edge-adaptive color interpolation scheme produces quantitatively better and visually more pleasing results than conventional approaches.

Highly Accelerated SSFP Imaging with Controlled Aliasing in Parallel Imaging and integrated-SSFP (CAIPI-iSSFP)

  • Martin, Thomas;Wang, Yi;Rashid, Shams;Shao, Xingfeng;Moeller, Steen;Hu, Peng;Sung, Kyunghyun;Wang, Danny JJ
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.4
    • /
    • pp.210-222
    • /
    • 2017
  • Purpose: To develop a novel combination of controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) with integrated SSFP (CAIPI-iSSFP) for accelerated SSFP imaging without banding artifacts at 3T. Materials and Methods: CAIPI-iSSFP was developed by adding a dephasing gradient to the balanced SSFP (bSSFP) pulse sequence with a gradient area that results in $2{\pi}$ dephasing across a single pixel. Extended phase graph (EPG) simulations were performed to show the signal behaviors of iSSFP, bSSFP, and RF-spoiled gradient echo (SPGR) sequences. In vivo experiments were performed for brain and abdominal imaging at 3T with simultaneous multi-slice (SMS) acceleration factors of 2, 3 and 4 with CAIPI-iSSFP and CAIPI-bSSFP. The image quality was evaluated by measuring the relative contrast-to-noise ratio (CNR) and by qualitatively assessing banding artifact removal in the brain. Results: Banding artifacts were removed using CAIPI-iSSFP compared to CAIPI-bSSFP up to an SMS factor of 4 and 3 on brain and liver imaging, respectively. The relative CNRs between gray and white matter were on average 18% lower in CAIPI-iSSFP compared to that of CAIPI-bSSFP. Conclusion: This study demonstrated that CAIPI-iSSFP provides up to a factor of four acceleration, while minimizing the banding artifacts with up to a 20% decrease in the relative CNR.

Evaluation of the Utility of Self Produced MRI Radiofrequency Shielding Material (자체 제작한 자기공명영상 고주파 차폐체의 유용성 평가)

  • Lee, Jin-Hoe;Lee, Bo-Woo
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.11
    • /
    • pp.89-94
    • /
    • 2020
  • This paper proposes a better shielding method to over sampling technique. The new method uses aluminum foil for RF shielding. As a result of the phantom test, when the over-sampling technique was applied, the aliasing artifact was reduced by about 94% compared to before the application, and the case where the aluminum shielding band was applied was also reduced by about 92% compared to before application. In addition, the scan time also increased by more than 3 times in the case of the over-sampling technique, while it was found that there was no change from before the application of the aluminum shielding band Therefore, it was confirmed that the shielding band using aluminum foil can effectively remove aliasing artifacts without increasing the scan time..

Directionally Adaptive Aliasing and Noise Removal Using Dictionary Learning and Space-Frequency Analysis (사전 학습과 공간-주파수 분석을 사용한 방향 적응적 에일리어싱 및 잡음 제거)

  • Chae, Eunjung;Lee, Eunsung;Cheong, Hejin;Paik, Joonki
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.8
    • /
    • pp.87-96
    • /
    • 2014
  • In this paper, we propose a directionally adaptive aliasing and noise removal using dictionary learning based on space-frequency analysis. The proposed aliasing and noise removal algorithm consists of two modules; i) aliasing and noise detection using dictionary learning and analysis of frequency characteristics from the combined wavelet-Fourier transform and ii) aliasing removal with suppressing noise based on the directional shrinkage in the detected regions. The proposed method can preserve the high-frequency details because aliasing and noise region is detected. Experimental results show that the proposed algorithm can efficiently reduce aliasing and noise while minimizing losses of high-frequency details and generation of artifacts comparing with the conventional methods. The proposed algorithm is suitable for various applications such as image resampling, super-resolution image, and robot vision.

Magnetic Resonance Image Analysis using MESH for High-frequency Shielding (고주파 차폐용 Mesh를 이용한 자기공명영상 분석)

  • Shin, Woon-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.975-982
    • /
    • 2021
  • The purpose of this study is to evaluate the effect on the phantom for magnetic resonance imaging located nearby by partially shielding RF with a mesh made thinner than hair composed of copper, black metal, and polyester using metallic materials of titanium, which are commonly used for esophageal stents and implants in the body. Magnetic resonance images according to field of view (FOV) were analyzed in the Spin Echo T1 weighted images of TR 500 ms, TE 20 ms, NEX 1, and slice thickness 5mm using a Cardiac coil of 3T Achieva X-series. Aliasing artifact did not occur in FOV 304 mm × 304 mm, but it occurred in 250 mm × 250 mm and 170 mm × 170 mm. In FOV 170 mm × 170 mm, when a mesh was not used, the SNR was measured with 78.23, and when separated by standing a mesh in the middle, it was 215.05, and when completely shielded with a mesh, the SNR was 366.44. In addition, when completely shielded with a mesh, the aliasing artifact was also removed, and signal intensities on the left, middle and right of the image were also able to obtain homogeneous images compared to the previous two cases. In conclusion, if RF is partially shielded with a mesh, aliasing artifact can be removed, and magnetic resonance images with excellent image resolution and homogeneity can be obtained using a small FOV.

MRI Artifacts

  • 최순섭
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.51-57
    • /
    • 1997
  • MRI의 artifact는 대부분 신호의 부호화 방향에 따라서 방향성을 가지는데, 이를 요약해보면, 위상부호화 방향의 artifact에는 motion artifact, flow artifact, RF noise등이 있고, 주파수 부호화 방향의 artfact는 susceptibility artfact, chemical shift artifact, central line artifact등이 있으며, 양방향 모두 생길수 있는 것은 Aliasing artifact와 Gibb's phenomenon이고, 전체적으로 영샹의 질을 떨어뜨리는 것은 susceptibility artifact, Eddy current, cross talk등이 있다. 이런 artifact는 대부분은 MRI 자체의 물리적 특성에 다소간 기인하므로, artifact가 없는 양호한 영상을 얻기 위해서는 MRI의 설치 단계부터 관심이 필요하고, MRI의 기본원리와 다양한 artifact에 대해 이해함으로써, 제거 가능한 artifact는 제거하여 양질의 영상을 만들고 판독시의 오류를 피할 수 있도록 해야할 것이다.

  • PDF