• Title/Summary/Keyword: Alarm Unit

Search Result 84, Processing Time 0.029 seconds

Architecture of Signal Processing Module for Multi-Target Detection in Automotive FMCW Radar (차량용 FMCW 레이더의 다중 타겟 검출을 위한 신호처리부 구조 제안)

  • Hyun, EuGin;Oh, WooJin;Lee, Jong-Hun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.5 no.2
    • /
    • pp.93-102
    • /
    • 2010
  • The FMCW(Frequency Modulation Continuous Wave) radar possesses range-velocity ambiguity to identify the correct combination of beat frequencies for each target in the multi-target situation. It can lead to ghost targets and missing targets, and it can reduce the detection probability. In this pap er, we propose an effective identification algorithm for the correct pairs of beat frequencies and the signal processing hardware architecture to effectively support the algorithm. First, using the correlation of the detected up- and down-beat frequencies and Doppler frequencies, the possible combinations are determined. Then, final pairing algorithm is completed with the power spectrum density of the correlated up- and down-beat frequencies. The proposed hardware processor has the basic architecture consisting of beat-frequency registers, pairing table memory, and decision unit. This method will be useful to improve the radar detection probability and reduce the false alarm rate.

A Speaker Change Detection Experiment that Uses a Statistical Method (통계적 기법을 이용한 화자변화 검출 실험)

  • Lee, Kyong-Rok;Kim, Jin-Young
    • Speech Sciences
    • /
    • v.8 no.4
    • /
    • pp.59-72
    • /
    • 2001
  • In this paper, we experimented with speaker change detection that uses a statistical method for NOD (News On Demand) service. A specified speaker's change can find out content of each data in speech if analysed because it means change of data contents in news data. Speaker change detection acts as preprocessor that divide input speech by speaker. This is an important preprocessor phase for speaker tracking. We detected speaker change using GLR(generalized likelihood ratio) distance base division and BIC (Bayesian information criterion) base division among matrix method. An experiment verified speaker change point using BIC base division after divide by speaker unit using GLR distance base method first. In the experimental result, FAR (False Alarm Rate) was 63.29 in high noise environment and FAR was 54.28 in low noise environment in MDR (Missed Detection Rate) 15% neighborhood.

  • PDF

A determination of economic control limits considering process deterioration (공정의 열화를 고려한 경제적 관리한계 결정)

  • 심윤보;김성집
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.21 no.45
    • /
    • pp.237-246
    • /
    • 1998
  • In most statistical process control(SPC), control charts are used in which samples are taken and a suitable statistic is determined and plotted. In these control charts, control limits, ${\mu}{\pm}textsc{k{\sigma}}$, from which a decision is made are mostly ${\mu}{\pm}3{\sigma}$ and current literature in control charts are mainly concerned with detecting a shift in the mean. Therefore, when $\sigma$ is increased considerably after a long time, using control limits set at the first time causes a great deal of economic loss. In this paper the solutions to determine new control limits which maximizes the profit per unit produced and reduce $\sigma$ to economically optimal level for a certain cost when $\sigma$ is increased due to process deterioration are proposed. By applying new control limits, $\alpha$ error decreases considerably compared to apply initial control limits when $\sigma$ is increased due to process deterioration. Therefore, false alarm investigation cost drops down to the level of initial a error. And also this solution provides useful information regarding replacement of a process when the process is reviewed regularly.

  • PDF

A-GPS (Assisted GPS), is this the system we need for indoor location & navigation?

  • Magnusson, Lars E;Gronqvist, Oskar
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.67-70
    • /
    • 2006
  • For a long time the GSM and GPS world has been living side by side. There have been some half hearted attempts to invoke the GPS unit into GSM units but performance and usability has suffered. The A-GPS approach is interesting and we wanted to verify general performance for fleet application and alarm/emergency situations. The result is now promising but still more to enhancements are anticipated. We achieved near acceptable availability (${\sim}70%$) under indoor conditions. Accuracy was as anticipated (50-100 meter) as we are using reflected signals. Time to first fix is in general good in outdoor conditions but too long for indoor conditions (45-60 seconds). We would like manufactures to put some more effort to get better performance in the future as test with Nordnav high sensitivity measurement system proves that conditions indoor are at a level where better performance should be possible.

  • PDF

Real Time Alarm System of Enormous Structure Using RTK GPS (RTK GPS를 이용한 대형구조물의 실시간 경보 시스템)

  • 박운용;송연경;이현우
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.22 no.1
    • /
    • pp.11-19
    • /
    • 2004
  • Such social structures as bridges,, buildings, dams and towers have been transformed by their own load or fundamental ground. They have been behaved by other external causes. These regular or irregular behaviors threaten to do their users safety. Therefore, to monitor the load of the structures or reaction shown by them could help to verify their behaviors. RTK GPS allows the use of a static base station and remote rover unit to allow f3r data collection within several seconds and in real time. It is useful for monitoring the behaviors of massive structures like bridges. In this Study, Among GPS methods, we used RTK GPS to analyze the precision of monitoring and then on the basis of it, we developed a monitoring system using RTK GPS when measured the behavior of main tower of a suspension bridge by using RTK GPS. Comparing a deviation between observation values, X axis was Imm, Y axis was 1mm and Z axis 2.2mm. It turned out that it was possible to monitor and measure structures by RTK GPS.

Prototype Implementation of a Context Awareness System by Analyzing Alarm and Neighborhood Environment for Managing Underground Facilities (알람정보와 인접환경 분석을 통한 지하시설물 상황인식 시스템의 프로토타입 구현)

  • Cho, Sung-Youn;Hong, Sang-Ki;Jang, Seok-Woo
    • Spatial Information Research
    • /
    • v.19 no.3
    • /
    • pp.83-93
    • /
    • 2011
  • Since urban facilities have a signigicant meaning that represents the degree of development of nations and cities, it is very important to effectively manage and operate the facilities. In this paper, we propose a context-awareness system for managing urban underground facilities intelligently and develop its algorithm and prototype. The algorithm of the suggested system includes the period from the point when various sensors set up in USN environments sense abnormal signals and make alarms to the point when the context-awareness system analyzes the alarm and sends the analysis results to integrated platform and related modules. We then implement the prototype of the proposed context awareness system and verify the effectiveness of the system by performing unit tests. Our developed prototype will become the basis of actual system development. We expect that the suggested system will be used as a good reference model of related systems managing various types of urban facilities.

DEVELOPMENT OF AN IMPROVED FARE TOOL WITH APPLICATION TO WOLSONG NUCLEAR POWER PLANT

  • Lee, Sun Ki;Hong, Sung Yull
    • Nuclear Engineering and Technology
    • /
    • v.45 no.2
    • /
    • pp.257-264
    • /
    • 2013
  • In Canada Deuterium Uranium (CANDU)-type nuclear power plants, the reactor is composed of 380 fuel channels and refueling is performed on one or two channels per day. At the time of refueling, the fluid force of the cooling water inside the channel is exploited. New fuel added upstream of the fuel channel is moved downstream by the fluid force of the cooling water, and the used fuel is pushed out. Through this process, refueling is completed. Among the 380 fuel channels, outer rows 1 and 2 (called the FARE channel) make the process of using only the internal fluid force impossible because of the low flow rate of the channel cooling water. Therefore, a Flow Assist Ram Extension (FARE) tool, a refueling aid, is used to refuel these channels in order to compensate for the insufficient fluid force. The FARE tool causes flow resistance, thus allowing the fuel to be moved down with the flow of cooling water. Although the existing FARE tool can perform refueling in Korean plants, the coolant flow rate is reduced to below 80% of the normal flow for some time during refueling. A Flow rate below 80% of the normal flow cause low flow rate alarm signal in the plant operation. A flow rate below 80% of the normal flow may cause difficulties in the plant operation because of the increase in the coolant temperature of the channel. A new and improved FARE tool is needed to address the limitations of the existing FARE tool. In this study, we identified the cause of the low flow phenomena of the existing FARE tool. A new and improved FARE tool has been designed and manufactured. The improved FARE tool has been tested many times using laboratory test apparatus and was redesigned until satisfactory results were obtained. In order to confirm the performance of the improved FARE tool in a real plant, the final design FARE tool was tested at Wolsong Nuclear Power Plant Unit 2. The test was carried out successfully and the low flow rate alarm signal was eliminated during refueling. Several additional improved FARE tools have been manufactured. These improved FARE tools are currently being used for Korean CANDU plant refueling.

Tape-Type Liquid Leakage Film Sensor (액체누설 감지용 테이프형 필름센서)

  • Yu, D.K.;Kim, K.S.;Yub, H.K.;Han, G.H.;Jin, D.J.;Kim, J.H.;Han, S.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.2
    • /
    • pp.146-154
    • /
    • 2011
  • The adhesive-tape of a liquid leak film sensor including the alarm system is developed. The sensing film is composed of three layers such as base film layer, conductive line layer, and protection film layer. The thickness of film is 300~500 um, the width is 3.55 cm, and the unit length is 200 m. On the conductive line layer, three conducting lines and one resistive line are formulated by the electronic printing method with a conducting ink of silver-nano size. When a liquid leaks for the electricity to be conducted between the conductive line and the resistive line, the position of leakage is monitored by measuring the voltage varied according to the change of resistance between two lines. The error range of sensing position of 200 m film sensor is ${\pm}1m$.

A Study on Warnning Criteria Investigation of Automated Rainfall Warning System -Focused on Realationship of Water Level, Discharge and Precipitation - (자동우량경보시설 경보발령기준 검토 연구 - 수위, 유출량, 강수량의 관계를 중심으로 -)

  • Ahn, Jae-Chan;Lee, Jong-Seol;Chol, Woo-Chung;Lee, Byong-Ju
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.101-109
    • /
    • 2008
  • Automated rainfall warning system is a facility to prevent casualties who were recreating in the down stream region with operating lead broadcasting or signaling warning automatically when torrential rainfall occurs in mountainous area. But standard of conventional warning does not consider the characteristics of basin, and warning signal. Evacuation signal 1 and evacuation signal 2 are uniformly signaled when the 10minute moving total of observed rainfall is higher than 4 mm, 6 mm, and 8 mm respectively. therefore, local governments and relative agencies had re-established the standard of warning by analyzing the risk water level, critical discharge and reference rainfall, which are considering the characteristics of basin. In this study the standard of conventional and re-established warning of weolseong basin, which is available to acquire a real rainfall. There are analyzed by considering the risk water level, critcal discharge and reference rainfall. Also this study compares rainfall of conventional and re-established warning standard and indentifies problems by analyzing adequacy of rainfall estimation for warning and proposes alternative. The standard of conventional warning which investigates with the converted rainfall(unit of a minute) issued too many alarm. The re-established standard upward has the necessity which will be regulated about the alarm announcement number of times. Considers the safety, upward regulation of alarm standard rainfall is a necessity which will be prudent.

Comparison of the Clinical Performance between Two Pulse Oximeters in NICU: Nellcor $N-595^{(R)}$ versus Masimo $SET^{(R)}$ (신생아 중환자실에서 맥박산소측정기의 감지도 비교: Nellcor $N-595^{(R)}$ versus Masimo $SET^{(R)}$)

  • Lee, Heun-Ji;Choi, Jang-Hwan;Min, Sung-Ju;Kim, Do-Hyun;Kim, Hee-Sup
    • Neonatal Medicine
    • /
    • v.17 no.2
    • /
    • pp.245-249
    • /
    • 2010
  • Purpose: Numerous false alarms by pulse oximetry, which is widely used in neonatal intensive care unit, can delay response to true alarms. Masimo $SET^{(R)}$ was introduced lately, to overcome false alarms by motion. We compared the clinical performance of two devices (Nellcor $N-595^{(R)}$ and Masimo $SET^{(R)}$) for the evaluation of the false alarm frequency during usual motion artifacts and stable state. Methods: A total of 20 preterm infants weighing 1,000-2,500 g were enrolled in the study. The sensors of two devices were placed on the different feet on the same infants, and both devices were programmed to emit an alarm for episode of hypoxemia (SpO2$\leq$85%). The false alarms were defined as episodes of poor correlation with ECG heart rate, poor waveforms, and the absence of obvious signs of hypoxia. We compared the frequency of false alarms between the two devices. Results: The mean chronological age was 20.8 days and the mean body weight was 1,668 g on the study day. The frequency of total false alarm was significantly fewer for Masimo $SET^{(R)}$ pulse oximetry (48 in Nellcor $N-595^{(R)}$, 27 in Masimo $SET^{(R)}$) although the false alarm during usual motion artifacts was not significantly between two devices (32 in Nellcor $N-595^{(R)}$, 19 in Masimo $SET^{(R)}$). Conclusion: The Masimo $SET^{(R)}$ pulse oximetry has fewer false alarm rates and identified more true hypoxic events than Nellcor $N-595^{(R)}$ pulse oximetry. Therefore, it is useful for adequate oxygen therapy and helps to decrease unnecessary handling by clinicians and nurses.