• Title/Summary/Keyword: Alarm Parameter

Search Result 46, Processing Time 0.026 seconds

Establishment of Alarm Criteria for Automatic Water Quality Monitoring System in Korea

  • Lim, Byung-Jin;Hong, Eun-Young;Kim, Hyun-Ook;Jeong, Eun-Sook;Heo, Woo-Myung;Kim, Yoon-Hee
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.4
    • /
    • pp.423-430
    • /
    • 2008
  • As of September 2008,45 Automatic Water Quality Monitoring Systems (AWQMS) have been installed at different sites on the 4 rivers to detect early the presence of pollutants in water and to issue an alarm. We count the number of issuing alarms by AWQMS, however, we will find the alarm has hardly been issued. The reasons for the scarcity of alarm issue are extensively being examined. The National Institute of Environmental Research attributes wrong alarm criteria for each AWQMS station to one the reasons. In this study, a suggestion has been made to modify the current alarm criteria to correspond with characteristics of river water quality. The current system with only two criteria (low and high) should be replaced as four-criteria systems (low, medium, high, and severe) based on cases of other advanced countries and stream conditions of Korea. The highest value of data collected for 5 years was suggested as the alarm criteria for each parameter. Meanwhile the alarm criteria for VOCs, phenol and heavy metals were established as same as drinking water quality criteria.

An Efficient Adaptive Polarimetric Processor with an Embedded CFAR

  • Park, Hyung-Rae;Kwag, Young-Kil;Wang, Hong
    • ETRI Journal
    • /
    • v.25 no.3
    • /
    • pp.171-178
    • /
    • 2003
  • To improve the detection performance of surveillance radars with polarization diversity, we developed an adaptive polarimetric processor and compared it with other polarimetric processors. We derived our adaptive polarimetric processor, called the polarization discontinuity detector (PDD), from the generalized likelihood ratio (GLR) test principle for the unspecified target component. We derived closed-form expressions of its probabilities of detection and false alarm, and compared its performance to that of the adaptive polarization canceller (APC) and Kelly's GLR processor. The PDD had a performance similar to Kelly's GLR in Gaussian clutter, and both the PDD and Kelly's GLR, which have embedded constant false alarm rates (CFARs), outperformed the APC, especially when the target polarization state was close to the clutter's polarization state. The important difference is that the PDD is much simpler than Kelly's GLR for hardware/software implementation, because the PDD does not require a costly two-parameter filter bank to cover the unknown target polarization state as Kelly's GLR does.

  • PDF

Fast PN Code Acquisition with Novel Adaptive Architecture in DS-SS Systems (직접대역확산방식에서 새로운 적응형 구조를 이용한 PN 코드의 빠른 포착)

  • 오해석;임채현;한동석
    • Proceedings of the IEEK Conference
    • /
    • 2000.06a
    • /
    • pp.252-255
    • /
    • 2000
  • In this paper, a fast pseudo-noise (PN) code acquisition with novel adaptive architecture is presented in direct-sequence spread- spectrum (DS-SS) systems. Since an existing acquisition system has a fixed correlation tap size and threshold value, this system cannot adapt to various mobile communication environments and results in a low detection probability or a high false alarm rate and long acquisition time. Therefore, if a correlation tap size and a threshold value can be controlled adaptively according to received signals, problems of ail existing system will be solved. The system parameter varies adaptively by using constant false alarm rate (CFAR) algorithm well known in a field of detection and proposed signal-to-noise ratio (SNR) measurement system. By deriving formulas of the proposed system, the performance is analyzed.

  • PDF

Double-Dwell Hybrid Acquisition in DS-UWB System

  • Wang YuPeng;Chang Kyung-Hi
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.7A
    • /
    • pp.696-701
    • /
    • 2006
  • In this paper, we analyze the performance of double-dwell hybrid initial acquisition in DS-UWB system via detection, miss, false alarm probabilities and mean acquisition time. In the analysis, we consider the effect of the acquisition sequence, and deployment scenario of the abundant multipath components over the small coverage of the piconet in DS-UWB system. Based on the simulation, we obtain various performance on the mean acquisition time by varying the parameters, such as the total number of hypotheses to be searched, subgroup size, and dwell time. Then, we suggest the optimum parameter set for the initial acquisition in DS-UWB system.

A Study on the Reliability Comparison of Median Frequency and Spike Parameter and the Improved Spike Detection Algorithm for the Muscle Fatigue Measurement (근피로도 측정을 위한 중간 주파수와 Spike 파라미터의 신뢰도 비교 및 향상된 Spike 검출 알고리듬에 관한 연구)

  • 이성주;홍기룡;이태우;이상훈;김성환
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.5
    • /
    • pp.380-388
    • /
    • 2004
  • This study proposed an improved spike detection algorithm which automatically detects suitable spike threshold on the amplitude of surface electromyography(SEMG) signal during isometric contraction. The EMG data from the low back muscles was obtained in six channels and the proposed signal processing algorithm is compared with the median frequency and Gabriel's spike parameter. As a result, the reliability of spike parameter was inferior to the median frequency. This fact indicates that a spike parameter is inadequate for analysis of multi-channel EMG signal. Because of uncertainty of fixed spike threshold, the improved spike detection algorithm was proposed. It automatically detects suitable spike threshold depending on the amplitude of the EMG signal, and the proposed algorithm was able to detect optimal threshold based on mCFAR(modified Constant False Alarm Rate) in the every EMG channel. In conclusion, from the reliability points of view, neither median frequency nor existing spike detection algorithm was superior to the proposed method.

Wavelet circular harmonic function frequency selective joint transform correlator for rotation invariant pattern recognition (회전불변 패턴인식을 위한 WCHF-FSJTC)

  • 방준학;이하운;노덕수;김수중
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.2
    • /
    • pp.94-103
    • /
    • 1997
  • The WCHF-FSJTC (wavelet circular harmonic function frequency selective joint transform correlator) using th wavelet transformed CHF as the reference image in FSJTC is proposed for rotation invariant pattern recognition. Since the wavelet transform has the property of feature extraction, the proposed system can have the better DC (discrimination cpability) and the higher SNR(signal to noise ratio) compared with the conventional CHF-CJTC(circular harmonic function conventional joint transform correlator). And since the structure of the proposed system is FSJTC which can eliminate auto-correlation and cross-correlation between input images, it can eliminate false alarm caused by the overlapping among correlation peaks. The used wavelet functio is the morlet function, which is proper for the reference image used in this paper. the optimal dialation parameter and oscillation frequency of the wavelet function are also achieved with varying the parameters of the wavelet function. The computer simulation shows that the proposed system has the best performance when the dilation parameter is 0.8 and the oscillation frequency is 0.48.

  • PDF

Selection and Analysis of Operating Parameters for Condition Monitoring of Emergency Diesel Generator at Nuclear Power Plant (원자력발전소 비상디젤발전기 상태감시를 위한 운전인자 선정에 관한 연구)

  • Park, J.H.;Choi, K.H.;Lee, S.G.;Park, J.E.
    • Journal of Power System Engineering
    • /
    • v.11 no.3
    • /
    • pp.3-8
    • /
    • 2007
  • The emergency AC power supply system of the nuclear power plant is designed to supply the power to the nuclear reactor at the emergency operating condition. The safety function of the diesel generator at the nuclear power plant is to supply AC electric power to the plant safety system whenever the preferred AC power supply is unavailable. The reliable operation of onsite emergency diesel generator should be ensured by a conditioning monitoring system designed to maintain and monitor and forecast the reliability level of diesel generator. To do this kind of diesel generator condition monitoring we reviewed several operating factors and history of the wolsong unit 3 diesel generator and selected the proper conditioning monitoring operating factors.

  • PDF

An Expert System Using Diagnostic Parameters for Machine tool Condition Monitioring (공작기계 상태감시용 진단파라미터 전문가 시스템)

  • Shin, Dong-Soo;Chung, Sung-Chong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.10
    • /
    • pp.112-122
    • /
    • 1996
  • In order to monitior machine tool condition and diagnose alarm states due to electrical and mechanical faults, and expert system using diagnostic parameters of NC machine tools was developed. A model-based knowledge base was constructed via searching and comparing procedures of diagnostic parameters and state parameters of the machine tool. Diagnostic monitoring results generate through a successive type inference engine were graphically displayed on the screen of the console. The validity and reliability of the expert system was rcrified on a vertical machining center equipped with FANUC OMC through a series of experiments.

  • PDF

DGA Gases related to the Aging of Power Transformers for Asset Management

  • Kweon, Dongjin;Kim, Yonghyun;Park, Taesik;Kwak, Nohong;Hur, Yongho
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.372-378
    • /
    • 2018
  • Life management technology is required as the failure risk of aged power transformers increases. Asset management technology is developed to evaluate the remaining life, establish the replacement strategies, and decide the optimal investment based on the reliability and economy of power transformers. The remaining life assessment uses data such as installation, operation, maintenance, refurbishment, and failure of power transformers. The optimal investment also uses data such as maintenance, outage, and social costs. To develop the asset management system for power transformers, determining the degradation parameters related to the aging of power transformers and evaluating the condition of power transformers using these parameters are important. In this study, since 1983, 110,000 Dissolved Gas Analysis (DGA) data have been analyzed to determine the degradation parameters related to the aging of power transformers. The alarm rates of combustible gases ($H_2$, $C_2H_2$, $C_2H_4$, $CH_4$, and $C_2H_6$), TCG, CO, and $CO_2$ were analyzed. The end of life and failure rate (bathtub curve) of power transformers were also calculated based on the failure data from 1981 to 2014. The DGA gases related to discharge, overheating, and insulation degradation were determined based on alarm and failure rates. $C_2H_2$, $C_2H_6$, and $CO_2$ were discharge, oxidation, and insulation degradation parameters related to the aging of power transformers.

Reference Model Updating of Considering Disturbance Characteristics for Fault Diagnosis of Large-scale DC Bus Capacitors (대용량 직류버스 커패시터의 고장진단을 위한 외란특성 반영의 레퍼런스 모델 개선)

  • Lee, Tae-Bong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.213-218
    • /
    • 2017
  • The DC electrolytic capacitor for DC-link of power converter is widely used in various power electronic circuits and system application. Its functions include, DC Bus voltage stabilization, conduction of ripple current due to switching events, voltage smoothing, etc. Unfortunately, DC electrolytic capacitors are some of the weakest components in power electronics converters. Many papers have proposed different algorithms or diagnosis method to determinate the ESR and tan ${\delta}$ capacitance C for fault alarm system of the electrolytic capacitor. However, both ESR vary with frequency and temperature. Accurate knowledge of both parameters at the capacitors operating conditions is essential to achieve the best reference data of fault alarm. According to parameter analysis, the capacitance increases with temperature and the initial ESR decreases. Higher frequencies make the reference ESR with the initial ESRo value to decrease. Analysis results show that the proposed DC Bus electrolytic capacitor reference ESR model setting technique can be applied to advanced reference signal of capacitor diagnosis systems successfully.