• Title/Summary/Keyword: Al sample

Search Result 1,114, Processing Time 0.025 seconds

Comparison of the Pre-service Elementary Teachers' Understandings of the Basic Concepts of Astronomy and Their Attitudes Toward Astronomy between Korea and Japan (한일 초등 예비교사들의 천문학 기초개념 이해와 천문학에 대한 태도)

  • Lee, Myon-U;Jang, Eun-Suk
    • Journal of the Korean earth science society
    • /
    • v.28 no.7
    • /
    • pp.789-802
    • /
    • 2007
  • This study investigated pre-service elementary teachers' understanding of the basic concepts of and their attitudes toward astronomy in Korea and Japan. The survey instrument called the Astronomy Diagnostic lest (ADT) that was developed by the Collaboration for Astronomy Education Research (CAER) in 1998 was used and modified to tailor to the two countries' contexts, including 12 items written in the two languages, Korean and Japanese. The attitudes toward astronomy were examined by the Survey of Attitudes toward Astronomy (SATA), which was developed by Zeilik et al. in 1999. Cronbach's alpha of this sample of the study was 0.69, while the reliability of SATA was 0.87. All the pre-service elementary teachers in both Korea and Japan showed a low-level understanding of the basic concepts of astronomy. 38% of Korean pre-service elementary teachers had correct answers to the questions regarding the basic conceptions of astronomy, while 37% of Japanese participants had correct answers to them. Although there was no statistically significant difference between Korean and Japanese pre-service elementary teachers, Korean teachers scored higher than Japanese participants in SATA. A significant difference, however, was revealed in the categories of cognitive competence and value of the attitudes toward astronomy (p <.05). In addition, it was found that both Korean and Japanese pre-service elementary teachers scored less than 40% about the basic concepts of astronomy and that they obtained lower scores than the US college students with regard to the attitudes toward astronomy.

Validation Study of Korean Version of Survey of Attitudes Toward Statistics(K-SATS) (한국판 통계에 대한 태도 검사(K-SATS) 타당화)

  • Yi, Hyun-Sook;Jeon, Soo-Hyun
    • The Korean Journal of Applied Statistics
    • /
    • v.22 no.5
    • /
    • pp.1115-1129
    • /
    • 2009
  • Previous research has recently shown that non-cognitive factors such as attitudes toward statistics contribute positively to statistics learning, Hence, helping students develop positive attitudes toward statistics has become one of the essential goals of statistics teaching. A wide variety of instruments assessing attitudes toward statistics were developed and validated in foreign countries, but not many in Korea. The SATS-36(Survey of Attitudes Toward Statistics-36; Schau et al., 1995) has been regarded as one of the most valid measures of attitudes toward statistics. Therefore, this study was designed to validate a Korean version of Survey of Attitudes Toward Statistics(K-SATS). Instead of six factors of the original scale, a five-factor structure including interests, value, cognitive competence, difficulty, and effort was empirically supported by the Korean student sample. The results evidenced high reliability and construct validity of K-SATS. In addition, students' attitudes towards statistics differed across gender, level of statistics courses, degree programs, and major. These findings were discussed in terms of their implications for future research and statistics teaching.

Oxidative Changes in the Ramyon(deep fat fried instant noodles with palm oil) Lipids during Storage (저장중(貯藏中) plam유(油)로 유열처리(油熱處理)한 라면 유지(油脂)의 산패(酸敗))

  • Im, Hong Woo;Choi, Sang Won;Moon, Kwang Deok;Sohn, Tae Hwa
    • Current Research on Agriculture and Life Sciences
    • /
    • v.6
    • /
    • pp.121-127
    • /
    • 1988
  • Ramyon(deep fat fried instant noodle with palm oil) preserved in sunlight, room temp. ($20{\pm}5^{\circ}C$), incubator ($30{\pm}2^{\circ}C$) and corrugated fiber board box to investigate the oxidative changes of the Ramyon lipids. In the study, changes in acid value, peroxide value, carbonyl value, TBA value, fatty acid composition, iodine value and panel test were determined with the lipids extracted from the Ramyon samples in intervals for a period of 20 weeks. Acid value, peroxide value, carbonyl value and TBA value of the Ramyon lipid were increased slightly during the storage in aluminum foil package in the corrugated fiber board box in the dark room. They did not appear the oxidative rancid odor at the end of 20 weeks storage. Acid value, peroxide value, carbonyl value and TBA value of the samples under room temp., incubator slightly during storage, while a sharp increase of those values were noticed with the samples of sunlight. Especially, the TBA value of the Ramyon lipid under sunlight markedly increased within 14 weeks and then decreased. Oxidative rancid odor appeared at the end of 10 weeks storage under sunlight, while it took 18 weeks with the sample stored under room temp. and incubator. During the storage under incubator and sunlight for 18 weeks, the content of oleic, linoleic acid decreased, while palmitic and stearic acid increased. However, only small changes were noticed in iodine value of the samples.

  • PDF

Identification of Atmospheric PM10 Sources and Estimating Their Contributions to the Yongin-Suwon Bordering Area by Using PMF (PMF모델을 이용한 용인.수원 경계지역에서 PM10 오염원의 확인과 상대적 기여도의 추정)

  • Lee, Hyung-Woo;Lee, Tae-Jung;Yang, Sung-Su;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.4
    • /
    • pp.439-454
    • /
    • 2008
  • The purpose of this study was to extensively identify $PM_{10}$ sources and to estimate their contributions to the study area, based on the analysis of the $PM_{10}$ mass concentration and the associated inorganic elements, ions, and total carbon. The contribution of $PM_{10}$ sources was estimated by applying a receptor method because identifying air emission sources were effective way to control the ambient air quality. $PM_{10}$ particles were collected from May to November 2007 in the Yongin-Suwon bordering area. $PM_{10}$ samples were collected on quartz filters by a $PM_{10}$ high-volume air sampler. The inorganic elements (Al, Mn, V, Cr, Fe, Ni, Cu, Zn, Cd, Pb, Si, Ba, Ti and Ag) were analyzed by an ICP-AES after proper pre-treatments of each sample. The ionic components of these $PM_{10}$ samples ($Cl^_$, $NO_3^-$, $SO_4^{2-}$, $Na^+$, $NH_4^+$, $K^+$, $Ca^{2+}$, and $Mg^{2+}$) were analyzed by an IC. The carbon components (OC1, OC2, OC3, OC4, OP, EC1, EC2 and EC3) were also analyzed by DRI/OGC analyzer. Source apportionment of $PM_{10}$ was performed using a positive matrix factorization (PMF) model. After performing PMF modeling, a total of 8 sources were identified and their contribution were estimated. Contributions from each emission source were as follows: 13.8% from oil combustion and industrial related source, 25.4% from soil source, 22.1% from secondary sulfate, 12.3% from secondary nitrate, 17.7% from auto emission including diesel (12.1%) and gasoline (5.6%), 3.1% from waste incineration and 5.6% from Na-rich source. This study provides information on the major sources affecting air quality in the receptor site, and therefore it will help us maintain and manage the ambient air quality in the Yongin-Suwon bordering area by establishing reliable control strategies for the related sources.

Congruence in Leader and Follower Perceptions of Leader-Member Exchange: Relationships with Organizational Commitment and Perceptions of Organizational Politics (리더-구성원 교환관계에 대한 리더와 구성원 지각의 정합성: 조직정치지각과 정서적 조직몰입의 관계를 중심으로)

  • Park, Jae-Chun
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.11
    • /
    • pp.240-252
    • /
    • 2016
  • The purposes of this paper examines the extant to which congruence in leader and follower rating of LMX quality is related to organizational commitment, and perceptions of organizational politics(POPs). A conceptual model is introduced that identifies four combinations of leader and follower LMX ratings of Cogliser et al.(2009): balanced/low LMX(low leader and follower LMX), balanced/high LMX(high leader and follower LMX), follower overestimation(low leader LMX/high follower LMX), follower underestimation(high leader LMX/low follower LMX). The summary of results based on a sample of 236 matched pairs of leaders and followers in KOREA is as follows: First, balanced/high LMX and follower overestimation were associated with relatively high levels of affective organizational commitment, and perceptions of organizational politics. However, follower underestimation and balanced/low LMX was related to low levels of follower outcomes. In particular, follower underestimation and balanced/low LMX were significantly different from balanced/high LMX and follower overestimation. Second, perceptions of organizational politics was negatively related to affective organizational commitment in the four LMX relationship types. Especially, the negative relationship between POPs and organizational commitment was stronger for people who are low as compared with high in LMX quality. Theoretical and practical implications of our findings as well as directions for future research are provided.

Identification of PM10 Chemical Characteristics and Sources and Estimation of their Contributions in a Seoul Metropolitan Subway Station (서울시 지하역사에서 PM10의 화학적 특성과 오염원의 확인 및 기여도 추정)

  • Park, Seul-Ba-Sen-Na;Lee, Tae-Jung;Ko, Hyun-Ki;Bae, Sung-Joon;Kim, Shin-Do;Park, Duckshin;Sohn, Jong-Ryeul;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.1
    • /
    • pp.74-85
    • /
    • 2013
  • Since the underground transportation system is a closed environment, indoor air quality problems may seriously affect many passengers' health. The purpose of this study was to understand $PM_{10}$ characteristics in the underground air environment and further to quantitatively estimate $PM_{10}$ source contributions in a Seoul Metropolitan subway station. The $PM_{10}$ was intensively collected on various filters with $PM_{10}$ aerosol samplers to obtain sufficient samples for its chemical analysis. Sampling was carried out in the M station on the Line-4 from April 21 to 28, July 13 to 21, and October 11 to 19 in the year of 2010 and January 11 to 17 in the year of 2011. The aerosol filter samples were then analyzed for metals, water soluble ions, and carbon components. The 29 chemical species (OC1, OC2, OC3, OC4, CC, PC, EC, Ag, Al, Ba, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Si, Ti, V, Zn, $Cl^-$, $NO_3{^-}$, $SO_4{^{2-}}$, $Na^+$, $NH_4{^+}$, $K^+$, $Mg^{2+}$, $Ca^{2+}$) were analyzed by using ICP-AES, IC, and TOR after proper pretreatments of each sample filter. Based on the chemical information, positive matrix factorization (PMF) model was applied to identify the $PM_{10}$ sources and then six sources such as biomass burning, outdoor, vehicle, soil and road dust, secondary aerosol, ferrous, and brakewear related source were classified. The contributions rate of their sources in tunnel are 4.0%, 5.8%, 1.6%, 17.9%, 13.8% and 56.9% in order.

Via-size Dependance of Solder Bump Formation (비아 크기가 솔더범프 형성에 미치는 영향)

  • 김성진;주철원;박성수;백규하;이상균;송민규
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.8 no.1
    • /
    • pp.33-38
    • /
    • 2001
  • We investigate the via-size dependance of as-electroplated- and reflow-bump shapes for realizing both high-density and high-aspect ratio of solder bump. The solder bump is fabricated by subsequent processes as follows. After sputtering a TiW/Al electrode on a 5-inch Si-wafer, a thick photoresist for via formation it obtained by multiple-codling method and then vias with various diameters are defined by a conventional photolithography technique using a contact alinger with an I-line source. After via formation the under ball metallurgy (UBM) structure with Ti-adhesion and Cu-seed layers is sputtered on a sample. Cu-layer and Sn/pb-layer with a competition ratio of 6 to 4 are electroplated by a selective electroplating method. The reflow-bump diameters at bottom are unchanged, compared with as-electroplated diameters. As-electroplated- and reflow-bump shapes, however, depend significantly on the via size. The heights of as-electroplated and reflow bumps increase with the larger cia, while the aspect ratio of bump decreases. The nearest bumps may be touched by decreasing the bump pitch in order to obtain high-density bump. The touching between the nearest bumps occurs during the overplating procedure rather than the reflowing procedure because the mushroom diameter formed by overplating is larger than the reflow-bump diameter. The arrangement as zig-zag rows can be effective for realizing the flip-chip-interconnect bump with both high-density and high-aspect ratio.

  • PDF

Convergence Study on Unmet Demand and Influencing Factors in Advanced Cancer Patients Receiving Conventional Chemotherapy (고식적 항암화학요법 받는 진행성 암환자의 미충족 요구와 영향요인에 대한 융합적 연구)

  • Youm, Myeong-Ja;Park, Jeong Sook
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.11
    • /
    • pp.433-441
    • /
    • 2020
  • This study was attempted to use as basic data for developing a nursing intervention program suitable for terminal cancer patients by analyzing the unmet needs of advanced cancer patients receiving palliative chemotherapy and identifying the influencing factors. The subject of the study consisted of 71 patients with advanced cancer who were admitted to a university hospital and received palliative chemotherapy, and the research tool used CNAT (Comprehensive Needs Assessment tool in Cancer) developed by Shin et al., and data analysis was an independent sample. It was analyzed by t-test, ANOVA and multiple regression analysis. As a result of the study, the medical staff's area was the highest at 2.34 ± 0.63 out of 4 points, followed by psychological problems (2.09 ± 0.53) and information education (1.69 ± 0.45). Factors influencing unmet needs include educational background (β=.207, p=.047), thoughts on death (β=-.269, p=.018), diagnosis (β=-.283, p=. 013). Based on the results of this study, it is necessary to consider the needs of the medical staff in advanced cancer patients, provide psychological support, and consider ways to meet the needs according to academic background and diagnosis.

Knowledge, Barriers and Attitudes Towards Breast Cancer Mammography Screening in Jordan

  • Abu-Helalah, Munir Ahmad;Alshraideh, Hussam Ahmad;Al-Serhan, Ala-Aldeen Ahmad;Kawaleet, Mariana;Nesheiwat, Adel Issa
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.9
    • /
    • pp.3981-3990
    • /
    • 2015
  • Background: Breast cancer is the most common type of cancer in Jordan. Current efforts are focused on annual campaigns aimed at increasing awareness about breast cancer and encouraging women to conduct mammogram screening. In the absence of regular systematic screening for breast cancer in Jordan, there is a need to evaluate current mammography screening uptake and its predictors, assess women's knowledge and attitudes towards breast cancer and screening mammograms and to identify barriers to this preventive service. Materials and Methods: This cross-sectional study was conducted in six governorates in Jordan through face-to-face interviews on a random sample of women aged 40 to 69 years. Results: A total of 507 participants with mean age of $46.8{\pm}7.8$ years were interviewed. There was low participation rate in early detection of breast cancer practices. Breast self-examination, doctor examination and periodic mammography screening were reported by 34.9%, 16.8% and 8.6% of study participants, respectively. Additionally 3.8% underwent breast cancer screening at least once but not periodically, while 87.6% had never undergone mammography screening. Reported reasons for conducting the screening were: perceived benefit (50%); family history of breast cancer (23.1%); perceived severity (21.2%); and advice from friend or family member (5.8%). City residents have shown higher probability of undergoing mammogram than those who live in towns or villages. Results revealed negative perceptions and limited knowledge of study participants on breast cancer and breast cancer screening. The most commonly reported barriers for women who never underwent screening were: fear of results (63.8%); no support from surrounding environment (59.7); cost of the test (53.4%); and religious belief, i.e. Qadaa Wa Qadar (51.1%). Conclusions: In the absence of regular systematic screening for breast cancer in Jordan, the uptake of this preventive service is very low. It is essential for the country of Jordan to work on applying regular systematic mammography screening for breast cancer. Additionally, there is a need for improvement in the current health promotion programmes targeting breast cancer screening. Other areas that could be targeted in future initiatives in this field include access to screening in rural areas and removal of current barriers.

Association between Circulating Vitamin D, the Taq1 Vitamin D Receptor Gene Polymorphism and Colorectal Cancer Risk among Jordanians

  • Atoum, Manar Fayiz;Tchoporyan, Melya Nizar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.17
    • /
    • pp.7337-7341
    • /
    • 2014
  • Background: The physiological role of vitamin D extends beyond bone health and calcium-phosphate homeostasis to effects on cancer risk, mainly for colorectal cancer. Vitamin D may have an anticancer effect in colorectal cancer mediated by binding of the active form $1,25(OH)_2D$ to the vitamin D receptor (VDR). The Taq1 VDR gene polymorphism, a C-to-T base substitution (rs731236) in exon 9 may influence its expression and function. The aim of this study wass to determine the 25(OH)D vitamin D level and to investigate the association between circulating vitamin D level and Taq1VDR gene polymorphism among Jordanian colorectal cancer patients. Materials and Methods: This case control study enrolled ninety-three patients and one hundred and two healthy Jordanian volunteers from AL-Basheer Hospital/Amman (2012-2013). Ethical approval and signed consent forms were obtained from all participants before sample collection. 25(OH)D levels were determined by competitive immunoassay Elecsys (Roche Diagnostic, France). DNA was extracted (Promega, USA) and amplified by PCR followed by VDR Taq1 restriction enzyme digestion. The genotype distribution was evaluated by paired t-test and chi-square. Comparison between vitamin D levels among CRC and control were assessed by odds ratio with 95% confidence interval. Results: The vitamin D serum level was significantly lower among colorectal cancer patients (8.34 ng/ml) compared to the healthy control group (21.02ng/ml). Patients deficient in vitamin D (less than 10.0 ng/ml) had increased colorectal cancer risk 19.2 fold compared to control. Only 2.2% of CRC patients had optimal vitamin D compared to 23.5% among healthy control. TT, Tt and tt Taq1 genotype frequencies among CRC cases was 35.5%, 50.5% and 14% compared to 43.1%, 41.2% and 15.7% among healthy control; respectively. CRC patients had lower mean vitamin D level among TT ($8.91{\pm}4.31$) and Tt ($9.15{\pm}5.25$) genotypes compared to control ($21.3{\pm}8.31$) and ($19.3{\pm}7.68$); respectively. Conclusions: There is significant association between low 25(OH)D serum level and colorectal cancer risk. The VDRTaq1 polymorphism was associated with increased colorectal cancer risk among patient with VDRTaq1 TT and Tt genotypes. Understanding the functional mechanism of VDRTaq1 TT and Tt may provide a strategy for colorectal cancer prevention and treatment.