• Title/Summary/Keyword: Akers clasp

Search Result 12, Processing Time 0.015 seconds

EFFECTS OF ABUTMENT SPLINTING ON STRESS DISTRIBUTION IN UNILATERAL DISTAL EXTENSION RPD (지대치 연결고정에 따른 편측성 후방연장 국소의치에서의 응력분포)

  • Ahn Hee-Young;Jin Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.2
    • /
    • pp.154-166
    • /
    • 2004
  • Statement of problem: In distal extension removable partial denture, the preservation of health of abutment teeth are very important, but they are always subjected to unfavorable stress. Purpose: The purpose of this study was performed to investigate the effects of abutment splinting and design of direct retainer on the stress distribution of abutments in unilateral distal extension removable partial dentures. Material and method: Abutments were splinted by different method. In group 1, autment teeth were not splinted, in group 2, canine and 1st premolar were splinted, and in group 3, canine, 1st and 2nd premolars were all splinted. Three different types of direct retainer such as Akers clasp, RPI clasp, and wrought wire clasp were designed. Strain was measured with Switch & Balance Unit(SB-10, Measurement Group Instruments Division, Raleigh USA) and Strain Indicator(P-3500, Measurement Group Instruments Division, Raleigh, USA) 15kg of vertical and oblique loads was applied at central fossa of missing 2nd molar area. Results : The strain on lingual side of 2nd premolar was the greatest, and abutment splinting induced decrease of strain on buccolingual side of 2nd premolar. The strain of loaded area was decreased by abutment splinting and there was no statistical difference of strain between Group2 and Group 3, and strain on 2nd premolar in wrought wire clasp was the least. Conclusion: Within the limitations of this study, splinting of two distal abutment teeth is enough for stress distribution widely, and wrought wire clasp was more benefitable than others.

A 3-DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS ON THE SUPPORTING TISSUES OF REMOVABLE PARTIAL DENTURES WITH VARIOUS RETAINER DESIGNS (국소의치 유지장치의 설계변화에 따른 지지조직의 3차원적 유한요소법 응력분석)

  • Kim, Ki-Sook;Kim, Kwang-Nam;Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.413-439
    • /
    • 1995
  • The purpose of this study was to evaluate the stress distribution developed in the supporting structures by mandibular distal extension removable partial dentures with 2 different direct retainer designs and with or without indirect retainer and abutment splinting. The examined direct retainers on the second bicuspid abutment tooth were Akers clasp and RPA clasp, the indirect retainer was located on the mesial fossa of the first bicuspid, and the first and second bicuspid were splinted in case of tooth splinting. Total 8 cases were compared and analyzed with 3-dimensional finite element method. 150N were applied vertically on the artificial teeth of the removable partial denture, and then stress distribution patterns were analyzed and compared. The results were as follows : 1. The forces transmitted to the abutment tooth were primarily from the occlusal rests. 2. The abutment tooth was displaced distally when the force was applied. The compressive stress was observed at the distal root surface of the abutment tooth and the tensile stress, at the mesial root surface. 3. The denture base was displaced posteriorly and inferiorly when the force was applied. At the more distal portion of the denture base, the greater displacement was observed.And the anterior portion of the major connector was displaced superiorly. 4. The occlusal rest placed on the distal part of the abutment tooth tended to tip the tooth more posteriorly than did one on the mesial part of that tooth. 5. Severe superior displacement was observed at the anterior portion of the major connector in case of removable partial dentures without indirect retainer. 6. In case of tooth-splinting, the stress was distributed through all the root surface of both abuments. In case of no tooth-splinting, the stress was concentrated on the distal root surface of the primary abutment.

  • PDF