• Title/Summary/Keyword: Airflow evaluation

Search Result 67, Processing Time 0.022 seconds

Numerical evaluation of risk rates for contamination sources in a minienvironment (클린룸 국소환경에서 오염원의 위험율에 대한 수치해석적 평가)

  • Noh, Kwang-Chul
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.181-189
    • /
    • 2018
  • In this study, the risk rates of different contamination sources of the contaminant in a minienvironment were analyzed through Computational Fluid Dynamics (CFD) simulation. The airflow pattern characteristics can only predict the qualitative variation of contaminant concentration, but cannot evaluate the quantitative variations in the risk rate of sources. From the results, the ambient contamination sources mainly affect wafers in the Front Opening Unified Pod (FOUP), whereas the internal contamination sources mainly affect wafers laid on the robot arm in the minienvironment. And the purging plenum system is very useful in protecting the wafers in the FOUP from contaminants transferred from the Fan Filter Unit (FFU). However, this system is unable to protect the wafers on the robot arm from internal contaminants and the wafers in the FOUP from sources of the interface between the FOUP and the minienvironment.

Wind Environment Assessment around High-Rise Buildings through Wind Tunnel Test and Computational Fluid Dynamics

  • Min-Woo Park;Byung-Hee Nam;Ki-Pyo You;Jang-Youl You
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.4
    • /
    • pp.321-329
    • /
    • 2022
  • High-rise buildings constructed adjacent to low-rise structures experience frequent damage caused by the associated strong wind. This study aimed to implement a standard evaluation of the wind environment and airflow characteristics around high-rise apartment blocks using wind tunnel tests (WTT) and computational fluid dynamics (CFD) simulations. The correlation coefficient between the CFD and wind tunnel results ranged between 0.6-0.8. Correlations below 0.8 were due to differences in the wake flow area range generated behind the target building according to wind direction angle and the effect of the surrounding buildings. In addition, a difference was observed between the average velocity ratio of the wake flow wind measured by the WTT and by the CFD analysis. The wind velocity values of the CFD analysis were therefore compensated, and, consequently, the correlations for most wind angles increased.

MEAN VALUES OF CEPHALOMETRIC ANALYSIS FROM KOREAN ADULTS WITH ABNORMAL OCCLUSION IN RELATION TO THE DIAGNOSIS OF OBSTRUCTIVE SLEEP APNEA SYNDROME (폐쇄성 수면무호흡증 진단을 위한 한국인 성인 부정교합자의 두부방사선 사진 계측 분석에 의한 연구)

  • Park, Kwang-Ho;Huh, Jong-Ki;Ahn, Je-Young;Kim, Ji-Yong;Lim, Jae-Hyung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.3
    • /
    • pp.267-275
    • /
    • 2005
  • Obstructive sleep apnea syndrome (OSAS) is characterized by sleep-induced obstruction of the upper airway that results in cessation of airflow. Obstruction can occur at a number of points in the airway, but frequently in the oropharynx. A diagnostic evaluation includes cephalometry, computed tomography, magnetic resonance imaging, acoustic reflection technique, polysomnography and fibroptic endoscopy. Cephalometric measurements of the patients with obstructive sleep apnea have revealed that posterior airway anatomy has strong relations with the symptoms of them. A lateral cephalogram is routinely obtained in the radiologic evaluation of sleep apnea patients. The purpose of this study is to provide a the lateral cephalometric korean norms for the diagnosis and treatment of the patients with obstructive sleep apnea by analyzing the abnormal occlusion of Korean adults.

Uncertainty Analysis and Improvement of an Altitude TestFacility for Small Jet Engines

  • Jun, Yong-Min;Yang, In-Young;Kim, Chun-Taek;Yang, Soo-Seok;Lee, Dae-Sung
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.5 no.1
    • /
    • pp.46-56
    • /
    • 2004
  • The verification and improvement of the measurement uncertainty have beenperformed in the altitude test facility for small gas turbine engines, which was built atthe Korea Aerospace Research Institute (KARI) in October 1999. This test is performedwith a single spool turbojet engine at several flight conditions. This paper discussesthe evaluation and validation process for the measurement uncertainty improvements usedin the altitude test facility. The evaluation process, defined as tests before the facilitymodification, shows that the major contnbutors to the measurement uncertainty are theflow meter discharge coefficient, the inlet static and total pressures, the cell pressureand the fuel flow rate. The measurement uncertainty is focused on the primary parametersof the engine performance such as airflow rate, thrust and specific fuel consumption (SFC).The validation process, defined as tests after the facility modification, shows that themeasurement uncertainty, in seal level condition, is tmproved to the acceptable level throughthe facility modification. In altitude test conditions, the measurement uncertainties arenot improved as much as the uncertainty in sea level condition.

Evaluation of the Oxygen Transfer Parameters (α and F) of a Coarse Bubble Aeration System by Off-gas Column Test (Off-gas Column Test를 이용한 하수처리장 심층포기시스템의 산소전달 매개변수(α와 F)의 산정)

  • Kim, Chul Woong;Lee, Se Ho;Shin, Dong Rok;Lee, Ji Yong;Park, Jae Han;Ahn, Yoon Hee;Ko, Kwang Baik
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1119-1122
    • /
    • 2006
  • Aeration by using diffusers usually requires approximately 50~90% of the total electricity needed to operate WWTP (WasteWater Treatment Plant)s. Accurate evaluation of the oxygen transfer efficiency for an aeration system, and recommendation of a better alternative may help saving WWTP operational costs. Appropriate techniques and methods to achieve this purpose have not been introduced in Korea. In this study, in-process analysis was performed for a coarse bubble aeration system by the off-gas method to evaluate its applicability in Korea. To accomplish this analysis, an off-gas test, unsteady-state clean water test and steady-state off-gas column test was conducted and comparisons to other aeration systems were made. The ${\alpha}$ and the F estimated from the results of the unsteady-state clean water test and the steady-state off-gas column test were 0.61 and 0.90 respectively in a coarse bubble aeration system. The comparison of P.E tube diffusers laid out single spiral roll and ceramic dome diffusers laid out full floor coverage showed that the oxygen transfer efficiency of the coarse bubble aeration system was less than or similar to other aeration systems. But, airflow rates per unit area were 4~5 times greater than other aeration systems. In regards to the oxygen transfer efficiency for airflow rates per unit area, a retrofit to higher efficiency diffusers was urgently needed. This study showed proved that off-gas methods can apply to evaluate diffuser performances to estimate operating factors and to compare other aeration systems in Korea.

Non-Contact Level on Air Levitation Table with Porous Chamber Array (다공성 패드를 갖는 챔버의 배열에 따른 공기 부상 테이블의 비접촉 부상 수준에 대한 연구)

  • Kim, Joon Hyun;Jeong, Young Suk;Lee, Tae Geol;Kim, Tae Hoon;Jung, Hyo Jae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.6
    • /
    • pp.913-920
    • /
    • 2013
  • This paper presents an applicable basic design that can configure non-contact levitation table for conveying a large sheet of glass. The suggested air levitation table consists of a series of air chambers with porous pads and fans as the conveyor system. The air supply chambers are arrayed to supply an adequately strong upward airflow for supporting the glass. Levitation is controlled by the size and discharge velocity, of the chamber arrays, as well as the glass supporting height. After pre-evaluation of the glass rigidity and the filer functional performance, a one-way fluid structure interface (FSI) analysis is performed for predicting pressure and deflection working of the 8G glass in the transverse and longitudinal directions, respectively. After comparing calculated levels of flatness of the glass, it determines the chamber array for the linear non-contact conveying motion.

Survey evaluation of thermal boundary condition in the inside and outside of double skin facade

  • Shin, Hyun-Cheol;Jang, Gun-Eik
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.29-35
    • /
    • 2015
  • Purpose: Double skin facade is a representative advantageous passive technology of building skin in the aspect of energy saving and environment improvement, reduces heat loss with buffer space in winter season and enhances indoor air and comfort of residents by activating natural ventilation in mid-season. However, in summer season, temperature increase in the intermediate space due to solar energy from exterior transparent skin could be a potential problem; also, relatively weak buoyancy of air caused by low density difference between double-skin facade could increase cooling load as air of intermediate space in high temperature hangs. However, proof data is insufficient to objectify such phenomenon. Method: In this study, researchers surveyed air temperature of intermediate space and airflow and diagnosed its cause targeting on applied multistory facade in the building which gives thermal uncomfort to residents. Also, the researchers produced Solar-air heat transfer coefficient meter, measured thermal boundary condition of double-skin facade, and presented the result of measurement as an objectified verification material regarding overheating phenomenon in the intermediate space of double-skin facade in summer season. Result: Inefficient condition was verified that total heat increases and overheating due to insufficient natural ventilation in multistory facade. In addition, logic behind preceding research was objectified and verified regarding high temperature phenomenon in the intermediate space which could increase cooling load in summer season.

Effect of combined sodium hyaluronate and carboxymethyl cellulose on ocular surface in rat dry eye model

  • Moon, Jong-Gab;Ku, Sae-Kwang;Kwon, Young-Sam
    • Korean Journal of Veterinary Research
    • /
    • v.56 no.3
    • /
    • pp.155-160
    • /
    • 2016
  • This study was conducted to evaluate three different mixed formulations of sodium hyaluronate (SH) and carboxymethyl cellulose (CMC) using a low-humidity air flow-induced rat dry eye model and determine the most suitable mixture. The total thickness of the cornea, corneal epithelial thickness, corneal stroma thickness, damaged corneal epithelium percentage region, thickness of the bulbar conjunctiva epithelium, number of goblet cells, goblet cell occupation percentage region, and damaged bulbar conjunctiva epithelium percentage region were measured by histomorphological evaluation. After 5 h exposure to drying airflow, the thickness of the cornea and conjunctiva was decreased with desquamation of the corneal and conjunctiva epithelium. However, these dry eye symptoms were markedly inhibited by treatment with the reference and test formulations. More favorable effects on decreased thickness were detected in response to the CMC than the SH. However, SH had a greater protective effect against corneal and conjunctiva epithelial damage. The application of a mixture of 0.1% SH and 0.2% CMC showed more favorable effects on the corneal and conjunctival damage and the stabilization of the ocular surface than SH or CMC alone.

Evaluation of Comfortableness in Railroad Electric Rolling Stock - Focused on Temperature and Humidity - (철도 전동차내의 쾌적성 평가에 관한 연구 - 온도 및 습도를 중심으로 -)

  • 박덕신;배상호;정병철;이주열
    • Journal of the Korean Society for Railway
    • /
    • v.6 no.1
    • /
    • pp.41-48
    • /
    • 2003
  • Most of people spends their times in indoor about 85% of a day. Thus, indoor is more serious than outdoor concerned with the health. We discussed comfortableness in a railroad electric rolling stock, and focused on temperature and humidity. Electric rolling stock is one of major public transportation system because of an increasing in population and heavy traffic problems. The passengers are under the influence of indoor air quality such as air temperature, relative humidity and air velocity. Ventilation system in electric rolling stock should be designed for the health and comfort. One of the main aims is to create an acceptable thermal environment without draught problem. The draught sensation increases when the air temperature decreases and the air velocity increases. Airflow in electric rolling stork is turbulent. Temperature and humidity gradients in electric rolling stock have been studied. And, the difference between mean temperature and rotative humidity measured at 0.7, 0.9, 1.2, 1.7m above the floor. It has been found that temperature and relative humidity with large fluctuations caused more draught complaints.

A Numerical Analysis on the Outside Pressure Distribution by Outdoor Wind Effect in a High-rise Residential Building (수치해석을 이용한 초고층 주거건물에서 외풍영향에 의한 외벽 압력 분포 분석)

  • Kim, Chi-Wan;Yang, Soon-Chang;Ahn, Young-Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.10
    • /
    • pp.639-645
    • /
    • 2011
  • The object of this study is to analyze and evaluate outdoor wind pressure effect in a high-rise residential building when seasonal wind blow on coast area. The target building consists of 3 tower buildings over 250m in height. For the evaluation of the outdoor wind effect, CFD simulation was performed. The results of the simulations are as follows : 1) In that case of high-rise building, horizontal stream is more affected than vertical stream. 2) In case of summer season northeasterly wind, building pressure distributions are unstable and surface pressures of outside are effected respectively. 3) In case of winter season westerly wind, building preassure differentiations are not so much because of screening effects of the B, and the C buildings. 4) In case of winter season northwesterly wind, front wind affects on the A building directly because of no obstacles.