• Title/Summary/Keyword: Airflow control

Search Result 128, Processing Time 0.026 seconds

Analysis of Supply Airflow Control by a Stratified Thermal Model in a VAV System

  • Kim, Seo-Young;Moon, Jeong-Woo;Cho, Hyung-Hee
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.3
    • /
    • pp.46-56
    • /
    • 2001
  • The present study concerns the numerical simulation of a supply airflow control in a variable air volume (VAY) system. A stratified thermal model (multi-zone model) is suggested to predict a local thermal response of an air-conditioned space. The effects of various thermal parameters such as the cooling system capacity, the thermal mass of an air-conditioned space, the time delay of thermal effect, and the building envelope heat transmission are investigated. Further, the influence of control parameters such as the supply air temperature, the PI control factor and the thermostat location on a VAV system is quantitatively delineated. The results obtained show that the previous homogeneous lumped thermal model (single zone model) may overestimate the time taken to the set point temperature. It is also found that there exist the appropriate ranges of the control parameters for the optimal airflow control of the VAV system.

  • PDF

A Study on the Comparison Analysis of Minimum Airflow Control Logic of VAV Terminal Box (VAV 터미널 박스의 최소풍량 제어방식 비교 연구)

  • Cho, Young-Hum;Kang, Su-Hyun;Seong, Yoon-Bok
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.96-102
    • /
    • 2012
  • The minimum airflow of VAV terminal boxes is a key factor for comfort, indoor air quality(IAQ) and energy cost. If the minimum airflow is not reasonable, it would waste energy and make IAQ problems. There are two types of VAV terminal box control logic. One is the single maximum, another is the dual maximum control logic. Dual maximum control logic is more efficiency way to reduce the energy consumption. It has a minimum airflow set point and a heating maximum set point. It allows the minimum airflow set point to be much lower than single maximum control logic. A building simulation was conducted to evaluate the energy consumption and the IAQ according to the control logic of the V AV terminal box. In the simulation, dual maximum control logic can save the energy up to 6.5% compared to the single maximum control logic.

Change in the Plant Temperature of Tomato by Fogging and Airflow in Plastic Greenhouse (포그분사 및 공기유동에 의한 온실재배 토마토의 엽온 변화)

  • Nam, Sang-Woon;Kim, Young-Shik;Seo, Dong-Uk
    • Journal of Bio-Environment Control
    • /
    • v.23 no.1
    • /
    • pp.11-18
    • /
    • 2014
  • To investigate the influence of surrounding environment on the plant temperature and examine the effect of plant temperature control by fogging and airflow, plant temperature of tomato, inside and outside air temperature and relative humidity, solar radiation and wind speed were measured and analyzed under various experimental conditions in plastic greenhouse with two-fluid fogging systems and air circulation fans. According to the analysis of plant temperature and the change of inside and outside air temperature in each condition, inside air temperature and plant temperature were significantly higher than outside air temperature in the control and shading condition. However, in the fogging condition, inside air temperature was lower or slightly higher than outside air temperature. It showed that plant temperature could be kept with the temperature similar to or lower than inside air temperature in fogging and airflow condition. To derive the relationship between surrounding environmental factor and plant temperature, we did multiple regression analysis. The optimum regression equation for the temperature difference between plant and air included solar radiation, wind speed and vapor pressure deficit and RMS error was $0.8^{\circ}C$. To investigate whether the fogging and airflow contribute to reduce high temperature stress of plant, photosynthetic rate of tomato leaf was measured under the experimental conditions. Photosynthetic rate was the highest when using both fogging and airflow, and then fogging, airflow and lastly the control. So, we could assume that fogging and airflow can make better effect of plant temperature control to reduce high temperature stress of plant which can increase photosynthetic rate. It showed that the temperature difference between plant and air was highly affected by surrounding environment. Also, we could estimate plant temperature by measuring the surrounding environment, and use it for environment control to reduce the high temperature stress of plant. In addition, by using fogging and airflow, we can decrease temperature difference between plant and air, increase photosynthetic rate, and make proper environment for plants. We could conclude that both fogging and airflow are effective to reduce the high temperature stress of plant.

Characteristics of Intraoral Air Pressure, Airflow in Relation to Phonatory Efficiency in Cleft Palate Speakers

  • Baek, Jin-A;Shin, Hyo-Keun
    • Proceedings of the KSLP Conference
    • /
    • 2003.11a
    • /
    • pp.147-147
    • /
    • 2003
  • Recent aerodynamic and acoustic studies of VPI(velopharyngeal insufficiency) are non-invasive and safety, therefore, many researchers have used it to diagnose the hyper/hyponasality and articulation disorders of cleft palate patients. The purpose of this study was to estimate mainly the oropharyngeal air pressure and over all air flow in cleft lip and palate patients. The pressure-collecting catheter was positioned in the oropharyngel cavity around tongue base. Twelve adult control group and three cleft lip & palate patients were participated to this experimentation. Aerophone II was used to measure peak air flow, mean air flow, phonatory airflow, phonatory efficiency and resistance. The results were as follows: 1) Airflow of cleft lip & palate patients group were higher than those of control group. Fricative sounds /s/ and /s'/ showed the statistic significance of mean airflow and volume data. 2) Intraoral air pressure of cleft lip & palate patients was lower than those of control group.

  • PDF

An Aerodynamic and Acoustic Study of Nasalization in Cleft Palate Speakers. (구개열 언어의 비음화에 관한 공기역학 및 음향학적 연구)

  • Lee, Jong-Han;Shin, Hyo-Keun
    • Speech Sciences
    • /
    • v.5 no.1
    • /
    • pp.105-119
    • /
    • 1999
  • Cleft palate patients have general speech problems with resonance disorders and articulation disorders. The aim of this study is to find the aerodynamic and acoustic characteristics of the nasalization in cleft palate speakers. Thirteen control groups and three cleft palate patients pre- and post operation were selected for these studies. The test words are composed by polysyllabic words: consonants between high vowel /i/ analysis. The cleft palate patients repeated test words pre- and post-operation from one, three and six month periods. The subjects repeated test words on Macquirer and on Nasometer Model 6200-3. The aerodynamic and acoustic results of nasalization show as follows: (1) The nasal rate in overall airflow of aspirated consonant for cleft palate patients shows higher levels than that of the control group. It had decreased since one month after operation. (2) The overall airflow of cleft palate patients is higher than in the control group, however oral air pressure is lower than control group. (3) The nasal airflow and the nasal rate in overall airflow of cleft palate patients has higher than the control group, however its decreased after operation. (4) The nasalance scores of cleft palate patients were 40% higher than that of the control group. The scores did not decrease after operation. The nasalance score of lateral and fricative sounds did not decrease after operation.

  • PDF

Analysis of New Air Control System in Clean Stocker (Clean Stocker내 새로운 방식의 기류제어에 관한 해석)

  • Choe, Gi-Han;Han, Chang-U;Lee, Sang-Ryong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.1
    • /
    • pp.121-130
    • /
    • 2002
  • Clean stockers are being used by semiconductor and TFT-LCD manufacturers to store and buffer work in process. Since an important function of a stocker is to keep the contained material clean. The only way to keep the stored product clean is to provide constant clean airflow the product and through stocker, The airflow across the product prevent contamination from settling on the product. Up to now, stocker typically have been configured to receive their laminar airflow from fan filter units that are located on the side of the stocker This type of stocker may have such problems as complexity of structure, increment of temperature, mechanical vibration, initial investment and running cost. In this study, In order to solve the above mentioned problems, new air control system in stocker is proposed, which is to control open ratios of exits that are located on the side of the stocker without fan filter units. Open ratios of exits need to be optimized for the same quantities of airflow in each exit. In this study, static pressure regain was used for the analysis of the open ratios of exits theoretically and Blue Ridge Numerics FEM software, CFDesign, was used fur simulating airflow in stocker. As a result, Open ratios of exits important to provide constant clean airflow can be obtained by the analysis of static pressure regain and was verified by simulation results. Therefore, new air control system in stocker can be used by the semiconductor and TFT-LCD manufacturers.

A study on the idle speed control under load disturbance (변동에 강인한 공회전속도 제어에 관한 연구)

  • 최후락;장광수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1115-1119
    • /
    • 1996
  • The objective of this paper is to study on the idle speed control sing the fuzzy logic controller under load disturbance. The inputs of the fuzzy controller are error of rpm and rpm variation. The output of fuzzy controller is an ISC motor step. The airflow is controlled by the ISC motor movement and the idle speed is controlled by the airflow control. During the control, air to fuel ratio was checked by LAMBDA sensor. All experiments were carried in real vehicle.

  • PDF

An Aerodynamic Study of Velopharyngeal Closure Function in Cleft Palate Patients (구개열 환자의 비인강폐쇄 기능에 대한 공기역학적 연구)

  • Ahn, Tae-Sub;Yang, Sang-Ill;Shin, Hyo-Keun
    • Speech Sciences
    • /
    • v.1
    • /
    • pp.237-259
    • /
    • 1997
  • Cleft Palate speech appears to have hyper/hyponasality with velopharyngeal insufficiency and articulation disorders. Previous studies on Cleft Palate speech have shown that speech tends to have lower airflow and air pressure. To examine the aerodynamic characteristics of Cleft Palate speech, Aerophone II Voice function Analyzer was used. We measured sound pressure level, airflow, air pressure and glottal power. Three Cleft Palate adults and five normal adults participated in this experiment. The test words are composed of: (1) the sustained vowel /o/ (2) /CiCi/, where C is one of three different stop consonants in Korean (3) /bimi/. Subjects were asked to produce /bimi/ five times without opening their lips. All the data was statistically tested by t-test for Cleft Palate patients before operation groups and control groups and paired t-test for Cleft Palate patients before and after operation groups. The results were as follow: (1) Cleft Palate patients generally speak with incomplete oral closure and lower oral air pressure. As a result, the SPL of Cleft Palate before operation is 3 dB lower than control groups. (2) Airflow of Cleft Palate in phonation and articulation is lower than that of control groups. However, it increased after operation. Lung volume and mean airflow in phonation are significantly increased (p<0.05). (3) Although velopharyngeal function (velar opening rate) of Cleft Palate is poor in comparison with control groups, it was recovered after operation. In this event maximum flow rate and mean airflow rate are significantly increased (p<0.05). (4) Air pressure of Cleft Palate in speech is lower than that of control groups. In general, the air pressure of Cleft Palate increased after operation. In this event air pressure of glottalized consonant is significantly increased (p<0.04). (5) Glottal Power(mean power, mean efficient and mean resistant) of Cleft Palate patients is lower than that of control groups. But mean efficient and mean resistant of Cleft Palate patients increased significantly (p<0.05) after operation.

  • PDF

CHARACTERISTICS OF OROPHARYNGEAL AIR PRESSURE, AIRFLOW IN CLEFT PALATE PATIENTS (구개열 환자에서의 구강인두압력 및 공기유량에 관한 음성학적 특징)

  • Baek, Jin-A
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.1
    • /
    • pp.13-20
    • /
    • 2006
  • The articulation disorders associated with velopharyngeal insufficiency (VPI) in cleft palate patients are interested to clinicians particularly. The purpose of this study was to investigate mainly the oropharyngeal air pressure and overall air flow in cleft palate patients. The pressure-measuring catheter was positioned at the midportion of the oropharyngeal cavity with a facial mask. Test words were composed of 9 meaningless polysyllabic words and 17 meaningful words. Aerophone II and Nasometer II were used to measure peak air pressure, mean air pressure, maximum flow rate, volume, phonatory flow rate, nasalance. The data shows that airflow of the cleft palate patient group were higher than those of the control group. Intraoral air pressure of the cleft palate patient group was lower than those of the control group. The first vowel formant and first Bandwidths of the cleft palate patient group were higher than those of the control group.

Effects of Atmospheric Stability and Surface Temperature on Microscale Local Airflow in a Hydrological Suburban Area (대기 안정도와 지표면 온도가 미세규모 국지 흐름에 미치는 영향: 수문지역을 대상으로)

  • Park, Soo-Jin;Kim, Do-Yong;Kim, Jae-Jin
    • Atmosphere
    • /
    • v.23 no.1
    • /
    • pp.13-21
    • /
    • 2013
  • In this study, the effects of atmospheric stability and surface temperature on the microscale local airflow are investigated in a hydrological suburban area using a computational fluid dynamics (CFD) model. The model domain includes the river and industrial complex for analyzing the effect of water system and topography on local airflow. The surface boundary condition is constructed using a geographic information system (GIS) data in order to more accurately build topography and buildings. In the control experiment, it is shown that the topography and buildings mainly determine the microscale airflow (wind speed and wind direction). The sensitivity experiments of atmospheric stability (neutral, stable, and unstable conditions) represent the slight changes in wind speed with the increase in vertical temperature gradient. The differential heating of ground and water surfaces influences on the local meteorological factors such as air temperature, heat flow, and airflow. These results consequentially suggest that the meteorological impact assessment is accompanied by the changes of background land and atmospheric conditions. It is also demonstrated that the numerical experiments with very high spatial resolution can be useful for understanding microscale local meteorology.