• Title/Summary/Keyword: Airflow Resistance

Search Result 60, Processing Time 0.03 seconds

Development of CFD model for analyzing the air flow and temperature distribution in greenhouse with air-circulation fans (유동팬이 설치된 온실 내 기류 및 기온분포 해석을 위한 CFD 모델 개발)

  • Yu, In-Ho;Yun, Nam-Kyu;Cho, Myeong-Whan;Ryu, Hee-Ryong;Moon, Doo-Gyung
    • Korean Journal of Agricultural Science
    • /
    • v.41 no.4
    • /
    • pp.461-472
    • /
    • 2014
  • This study was conducted to build the CFD simulation model which can quantify the distribution of the meteorological factors in air-heated greenhouse for chrysanthemum according to the location and capacity of air-circulation fan. The CFD model was also verified by experiment. It was judged that SST model was the most appropriate turbulence model which can properly describe the airflow by the air-circulation fan. According to the simulation results, the differences between the measured and predicted temperatures from 18 points at each height in the greenhouse were $0.2{\sim}0.4^{\circ}C$ in average. This showed a good agreement between the predicted data and the measured ones. The developed CFD model can be a useful tool to evaluate and design the air-circulation systems in the greenhouse with various configurations.

Static Pressure Drop as Affected by Moisture and Fine Material in Wheat (밀의 함수율과 미세립자가 정압강하에 미치는 영향)

  • Kim, Y.J.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.4
    • /
    • pp.339-345
    • /
    • 1990
  • 공기통풍 건조시 공기흐름(airflow)에 대한 곡물저항(grain resistance)은 송풍시스템에서 fan의 선정시 매우 중요하다. 지금까지는 공기흐름에 대한 곡물저항은 주로 Shedd의 curve에 준하여 정해졌다. 그러나 실제의 경우 곡물수확 또는 건조시 기계적 원인에 의하여 미세립자(fine material)가 생성된다. 이에 본 연구에서 밀(red hard winter wheat)을 대상으로 송풍량, 함수율, 미세립자량이 정압강하(static pressure drop)에 미치는 영향을 규명하였고, 이러한 변수가 포함된 수학적 모델을 개발하였다. 독립변수는 0.051로부터 $0.203m^3/m^2.sec$에 이르는 7단계의 각각 다른 송풍량과 3단계의 함수율 (11, 13, 15%w.b), 4단계의 미세립자량(0, 2, 4, 8%)이고, 종속변수는 정압강하이다. 정압강하와 test bed에서의 송풍량은 micromanometer를 사용하여 측정하였다. 결과는 독립변수(송풍량, 함수율, 미세립자량)는 모두 정압강하에 significant하게 영향을 미치는 것으로 나타났다. 규정된 범위내에서 함수율이 증가함에 따라 정압강하는 최고 45% 까지 감소되었고, 반면 미세립자량이 증가함에 따라 정압강하는 최고 195%까지 증가되었다. 수집된 data로서 다음과 같은 regression equation이 개발되었다($P=AV+BV^2+C(MO)V+D(FM)V$). 본 연구의 결과는 공기송풍시스팀에서 송풍량, 함수율, 미세립자량이 정압강하에 미치는 영향을 규명하였고, 에너지 절약적 송풍시스템을 설계하는 데 도움이 될 수 있을 것이다.

  • PDF

The Tense-Lax Question and Intraoral Air Pressure in English Stops

  • Kim, Dae-Won
    • Speech Sciences
    • /
    • v.9 no.4
    • /
    • pp.113-130
    • /
    • 2002
  • Measurements were made of pressure rise time (PoRT), voice cessation time, flattened peak intraoral air pressure (Po), pressure static time (PoST), pressure-fall time and the duration of oral closure as four English speakers uttered isolated nonsense $V_{1}CV_{2}$ words containing /b/ and /p/ ($V_{1}=V_{2}$ and the V was /$\alpha$/), with stress on either $V_{1}orV_{2}$ alternately. The hypothesis tested was: The tense stop consonant. will be characterized either by a higher Po or a longer PoST, and/or by both against lax. Findings: (1) PoRT was significantly greater in /b/ than /p/, (2) the voiceless stop /p/ produced generally greater mean Po, averaged across five tokens, than its voiced counterpart /b/, but statistically insignificant, and (3) altogether, across stress, tokens and subjects, the difference in the calculated pressure static time (PoSTc), i.e., PoST + PoRT, between /p/ and /b/ was highly significant (p $\leq$ 0.003). Although further investigations remain to be taken, the results strongly supported the linguistic hypothesis of tense-lax distinction, with /b/ being lax and /p/ tense. Airflow resistance at the glottis and supraglottal air volume are assumed to be responsible for much of difference in PoRT between /p/ and /b/. The PoSTc reflecting, although indirectly, the respiratory efforts during the oral closure of a stop, was a convincing phonetic parameter of the consonantal tenseness based on respiratory efforts. The effects of stress on Po and PoSTc were inconsistent, and the shorter PoRT than consonantal constriction interval was always accompanied by Po and PoST.

  • PDF

Thermo-hydraulic Effect of Tubular Heat Exchanger Fitted with Perforated Baffle Plate with Rectangular Shutter-type Deflector

  • Md Atiqur Rahman
    • Korean Chemical Engineering Research
    • /
    • v.62 no.2
    • /
    • pp.191-199
    • /
    • 2024
  • A study was conducted on a tubular heat exchanger to improve its heat transfer rate by using a novel baffle plate design with discontinuous swirling patterns. The design consisted of perforated baffle plates with rectangular air deflectors positioned at varying angles. The tubes in the heat exchanger were arranged in a consistent alignment with the airflow direction and exposed to a uniform heat flux on their surfaces. Each baffle plate included sixteen deflectors inclined at the same angle and arranged in a clockwise pattern. This arrangement induced a swirling motion of the air inside a circular duct where the heated tubes were located, leading to increased turbulence and improved heat transfer on the tube surfaces. The spacing between the baffle plates was adjusted at different pitch ratios, and the Reynolds number was controlled within a range of 16,000 to 29,000. The effects of pitch ratios and inclination angles on the heat exchanger's performance were analyzed. The results indicated that using a baffle plate with rectangular deflectors inclined at 30° and a pitch ratio of 1.2 resulted in an average increase of 1.29 in the thermal enhancement factor.

The Role of the Electroglottography on the Laryngeal Articulation of Speech (전기 Glottography(EGG)를 이용한 후두구음역학적 특성)

  • 홍기환;박병암;양윤수;서수영;김현기
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.8 no.1
    • /
    • pp.18-26
    • /
    • 1997
  • There are two types of phonetic study, acoustic and physiologic, for differentiating the three manner categories of Korean stop consonants. On the physiologic studies, there are endoscopic, electromyographic(EMG), electroglottographic(EGG) and aerodynamic studies. In this study, I tried to investigate general features of Korean stops using EGG study for the open quotient of vocal fold and baseline shift during speech, and aerodynamic characteristics for e subglottal air pressure, air flow and glottal resistance at consonants. On the aerodynamic study, the glottalized and aspirated stops may be characterized by e increasing subglottal pressure comparing with lenis stop at consonants. The airflow is largest in the aspirated stops followed by lenis stops and glottalized. The glottal airway resistance (GAR) showed highest in the glottalized followed by the lenis, but lowest in e aspirated during e production of consonants, and showed highest in e aspirated, but low in the glottalized and lenis during the production of vowel. The glottal resistance at consonant showed significant difference among consonants and significant interaction between subject and types of consonant. The glottal resistance at vowel showed significant difference among consonants, and e interaction occured between subject and types of consonant. The electroglottography(EGG) has been used for investigating e functioning of e vocal folds during its vibration. The EGG should be related to the patterns of the vocal fold vibration during phonation in characterizing the temporal patterns of each vibratory cycle. The purpose of this study is to investigate the dynamic change of EGG waveforms during continuous speech. The dynamic changes of EGG waveforms fir the three-way distinction of Korean stops were characterized that the aspirated stop appears to be characterized by largest open quotient and smallest glottal contact area of the vocal folds in e initial portion of vocal fold vibration ; the lenis stop by moderate open quotient and glottal contact area ; but the glottalized stop by smallest open quotient and largest glottal contact area. There may be close relationship between the OQ(open quotient) in the initial voice onset and the glottal width at the time of consonant production, the larger glottal width just before vocal fold vibration results in the smaller OQ of the vocal fold vibration in the initial voice onset. The EGG changes of baseline shift during continuous speech production were characterized by the different patterns for the three types of Korean consonants. The small and less stiffness change of baseline shift was found for the lenis and the glottalized, and the largest and stiffest change was found for the aspirated. On the baseline shift for the initial voice onset, they showed so similar patterns with for the consonant production, larger changed in the aspirated. for the lenis and the glottalized during the initial voice onset, three subjects showed individual difference each other. I suggest at s characteristics were strongly related with articulatory activity of vocal tract for the production of consonant, especially for the aspirated stop. The suspecting factors to affect EGG waveforms are glottal width, vertical laryngeal movement and the intrapharyngeal pressure to neighboring tissue during connected spech. So the EGG may be an useful method to describe laryngeal activity to classify pulsing conditions of the larynx during speech production, and EGG research can be controls for monitoring the vocal tract articulation, although above factors to affect EGG would have played such a potentially role on vocal fold vibratory behavior obtained using consonant production.

  • PDF

A Study on the Airflow Distribution in the Diagonal Ventilation Circuit for the Design of a High Level Radioactive Waste Repository (고준위 방사성 폐기물 처분장 설계를 위한 Diagonal 환기 회로 내 공기량 분배에 관한 연구)

  • Hwang, In-Phil;Choi, Heui-Joo;Roh, Jang-Hoon;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.22 no.3
    • /
    • pp.173-180
    • /
    • 2012
  • In this study, diagonal ventilation circuits that are advantageous in air flow direction control were studied. Based on the results of the study, it could be seen that air volumes in diagonal ventilation circuits could also be calculated using numerical formulas or programs if the air volumes and air flow directions to be infused into diagonal branches are determined in advance as with other serial/parallel circuits. To apply the results, design plans for high level radioactive waste repositories applied with diagonal ventilation circuits and parallel ventilation circuits. To compared the each design plans and obtain expected operation results, ventilation network simulations were conducted through the Ventsim program which is a ventilation networking program. Based on the results, in the case of diagonal repositories that was expected to cause great increases in resistance, fan pressure was 1570 pa, total flux was 84 $m^3/s$, fan efficiency was 76.4%, fan power consumption was 181.2 kW and annual fan operating costs were 178,710,838 and thus maximum around 8% differences were shown in pressure and flux values and a difference of around 1.5% was shown in terms of operating costs.

Water-blocking Asphyxia of N95 Medical Respirator During Hot Environment Work Tasks With Whole-body Enclosed Anti-bioaerosol Suit

  • Jintuo Zhu;Qijun Jiang;Yuxuan Ye;Xinjian He;Jiang Shao;Xinyu Li;Xijie Zhao; Huan Xu;Qi Hu
    • Safety and Health at Work
    • /
    • v.14 no.4
    • /
    • pp.457-466
    • /
    • 2023
  • Background: During hot environment work tasks with whole-body enclosed anti-bioaerosol suit, the combined effect of heavy sweating and exhaled hot humid air may cause the N95 medical respirator to saturate with water/sweat (i.e., water-blocking). Methods: 32 young male subjects with different body mass indexes (BMI) in whole-body protection (N95 medical respirator + one-piece protective suit + head covering + protective face screen + gloves + shoe covers) were asked to simulate waste collecting from each isolated room in a seven-story building at 27-28℃, and the weight, inhalation resistance (Rf), and aerosol penetration of the respirator before worn and after water-blocking were analyzed. Results: All subjects reported water-blocking asphyxia of the N95 respirators within 36-67 min of the task. When water-blocking occurred, the Rf and 10-200 nm total aerosol penetration (Pt) of the respirators reached up to 1270-1810 Pa and 17.3-23.3%, respectively, which were 10 and 8 times of that before wearing. The most penetration particle size of the respirators increased from 49-65 nm before worn to 115-154 nm under water-blocking condition, and the corresponding maximum size-dependent aerosol penetration increased from 2.5-3.5% to 20-27%. With the increase of BMI, the water-blocking occurrence time firstly increased then reduced, while the Rf, Pt, and absorbed water all increased significantly. Conclusions: This study reveals respirator water-blocking and its serious negative impacts on respiratory protection. When performing moderate-to-high-load tasks with whole-body protection in a hot environment, it is recommended that respirator be replaced with a new one at least every hour to avoid water-blocking asphyxia.

Correlation of Tracheal Cross-sectional Area with Parameters of Pulmonary Function in COPD (만성 폐쇄성 폐질환에서 기관의 단면적과 폐기능지표와의 상관관계)

  • Lee, Chan-Ju;Lee, Jae-Ho;Song, Jae-Woo;Yoo, Chul-Gyu;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo;Chung, Hee-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.628-635
    • /
    • 1999
  • Background : Maximal expiratory flow rate is determined by the size of airway, elastic recoil pressure and the collapsibility of airway in the lung. The obstruction of expiratory flow is one of the major functional impairments of emphysema, which represents COPD. Nevertheless, expiratory narrowing of upper airway may be recruited as a mechanism for minimizing airway collapse, and maintaining lung volume and hyperinflation by an endogenous positive end-expiratory pressure in patients with airflow obstruction. We investigated the physiologic role of trachea in respiration in emphysema. Method : We included 20 patients diagnosed as emphysema by radiologic and physiologic criteria from January to August in 1997 at Seoul Municipal Boramae Hospital. Chest roentgenogram, high resolution computed tomography(HRCT), and pulmonary function tests including arterial blood gas analysis and body plethysmography were taken from each patient. Cross-sectional area of trachea was measured according to the respiratory cycle on the level of aortic arch by HRCT and calibrated with body surface area. We compared this corrected area with such parameters of pulmonary function tests as $PaCO_2$, $PaO_2$, airway resistance, lung compliance and so on. Results : Expiratory cross-sectional area of trachea had significant correlation with $PaCO_2$ (r=-0.61, p<0.05), $PaO_2$ (r=0.6, p<0.05), and minute ventilation (r=0.73, p<0.05), but inspiratory cross-sectional area did not (r=-0.22, p>0.05 with $PaCO_2$, r=0.26, p>0.05 with $PaO_2$, and r=0.44, p>0.05 with minute ventilation). Minute ventilation had significant correlation with tidal volume (r=0.45, p<0.05), but it had no significant correlation with respiratory frequency (r=-0.31, p>0.05). Cross-sectional area of trachea had no significant correlation with other parameters of pulmonary function including $FEV_1$, FVC, $FEV_1$/FVC, peak expiratory flow, residual volume, diffusing capacity, airway resistance, and lung compliance, whether the area was expiratory or inspiratory. Conclusion : Cross-sectional area of trachea narrowed during expiration in emphysema, and its expiratory area had significant correlation with $PaCO_2$, $PaO_2$, and minute ventilation.

  • PDF

The Influence of Fat-Free Mass to Maximum Exercise Performance in Patients with Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환에서 제지방량이 최대운동능력에 미치는 영향)

  • Mun, Yeung Chul;Park, Hye Jung;Shin, Kyeong Cheol;Chung, Jin Hong;Lee, Kwan Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.4
    • /
    • pp.346-354
    • /
    • 2002
  • Background : Dyspnea and a limitation in exercise performance are important cause of disability in patients with chronic obstructive pulmonary disease(COPD). A depleted nutritional state is a common problem in patients with a severe degree of chronic airflow limitation. This study was carried out to assess the factors determining the maximum exercise capacity in patients with COPD. Methods : The resting pulmonary function, nutritional status, and maximum exercise performance was assessed in 83 stable patients with moderate to severe COPD. The nutritional status was evaluated by bioelectrical impedance analysis. Maximum exercise performance was evaluated by maximum oxygen uptake($VO_2max$). Results : Among the 83 patients, 59% were characterized by nutritional depletion. In the depleted group, a significantly lower peak expiratory flow rate(p<0.05), Kco(p<0.01) and maximum inspiratory pressure(p<0.05), but a significantly higher airway resistance(p<0.05) was observed. The maximum oxygen uptake and the peak oxygen pulse were lower in the depleted group. The $VO_2max$ correlated with some of the measures of the body composition : fat-free mass(FFM), fat mass(FM), body mass index(BMI), intracellular water index(ICW index), and pulmonary function : forced vital capacity(FVC), forced inspiratory vital capacity(FIVC), diffusion capacity(DLCO) : or maximum respiratory pressure : maximum inspiratory pressure(PImax), maximum expiratory pressure(PEmax). Stepwise regression analysis demonstrated that the FFM, DLCO and FIVC accounted for 68.8% of the variation in the $VO_2max$. Conclusion : The depletion of the FFM is significant factor for predicting the maximum exercise performance in patients with moderate to severe COPD.

Genetic Polymorphisms of the $\beta_2$-Adrenergic Receptor in the Severity of Bronchial Asthma (기관지 천식 환자에서 천식 증상의 정도에 따른 $\beta_2$ 교감신경 수용체의 유전자 다형성)

  • Shim, Jae-Jeong;Kim, Jei-Hyung;Lee, Seung-Yong;Kwan, Young-Hwan;Lee, So-Ra;Lee, Sang-Youb;Kang, Se-Yong;Kang, Yong-Koo;Cho, Jae-Youn;In, Kwang-Ho;Won, Nam-Hee;Yoo, Se-Hwa;Kang, Kyung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.77-89
    • /
    • 1998
  • Background: Genetic and environmental factors are known to affect the incidence and severity of asthma. Stimulation of $\beta_2$-Adrenergic Receptor ($\beta_2$AR) results in smooth muscle relaxation, leading to decrease in resistance of airflow. The gene encoding the $\beta_2$AR has recently been seguenced. The $\beta_2$AR genotype at the polymorphic loci of codons 16, 27, 34, and 164 was known to cause changes in the amino acids. The relationships between the structure of the $\beta_2$AR and its functions are being elucidated. Purpose : The gene encoding the $\beta_2$AR was carried out to assess the frequency of polymorphisms in bronchial asthma, to determine wheather these polymorphisms have any relation to the severity, or nocturnal symptoms in bronchial asthma. Methods: The subjects studied were 103 patients with bronchial asthma, which consisted of 30 mild episodic, 32 mild persistent, 17 moderate, and 24 severe asthma patients. The polymorphisms of the $\beta_2$AR gene were detected by mutated allele specific amplification (MASA) method at the codons 16,27,34, and 164. Results: The most frequent polymorphism was arginine 16 to glycine. The other two polymorphisms, valine 34 to methionine and glutamine 27 to glutamic acid occured in 11 and 6 patients respectively. The polymorphism of threonine 164 to isoleucine was not found in our enrolled patients. The homozygous polymorphism of $\beta_2$AR gene was found in only arginine 16 to glycine (12.6%). The heterozygous polymorphisms of $\beta_2$AR gene were in arginine 16 to glycine, valine 34 to methionine, and glutamine 27 to glutamic acid, as 65.1 %,10.7%, and 5.8% respectively in asthma patients. The presence of agrginine 16 to glycine heterozygous or/and homozygous polymorphism was associated in severe asthma (p=0.015), but there was no association between the other three polymorphisms and the severity of asthma. The frequency of the $\beta_2$AR gene polymorphisms was no relation in nocturnal asthma as compared with non-nocturnal asthma. Conclusion: The arginine 16 to glycine polymorphism of the $\beta_2$AR gene is the most frequently found in asthma patients and association with severe asthma. But there was no association between the polymorphism of the $\beta_2$AR gene and nocturnal asthma.

  • PDF