• 제목/요약/키워드: Airconditioner Load

검색결과 6건 처리시간 0.019초

확산 Markov 프로세스 모델을 이용한 Queueing System 기반 지능 부하관리에 관한 연구 (A Study on the Intelligent Load Management System Based on Queue with Diffusion Markov Process Model)

  • 김경동;김석현;이승철
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.891-897
    • /
    • 2009
  • This paper presents a novel load management technique that can lower the peak demand caused by package airconditioner loads in large apartment complex. An intelligent hierarchical load management system composed of a Central Intelligent Management System(CIMS) and multiple Local Intelligent Management Systems(LIMS) is proposed to implement the proposed technique. Once the required amount of the power reduction is set, CIMS issues tokens, which can be used by each LIMS as a right to turn on the airconditioner. CIMS creates and maintains a queue for fair and proper allocation of the tokens among the LIMS requesting tokens. By adjusting the number tokens and queue management policies, desired power reduction can be achieved smoothly. The Markov Birth and Death process and the Balance Equations utilizing the Diffusion Model are employed for evaluation of queue performances during transient periods until the static balances among the states are achieved. The proposed technique is tested using a summer load data of a large apartment complex and give promising results demonstrating the usability in load management while minimizing the customer inconveniences.

인버터에어컨에 능동역률개선회로 적용에 관한 연구 (A Study On The Application Of Active Power Factor Correction Circuit In Inverter Airconditioner)

  • 김태덕;배영돈;박윤서
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.306-308
    • /
    • 1996
  • The demands of minimizing the reactive power and reducing the current harmonics are increasing nowdays. The inverter airconditioner needs high inductive power and it operates with wide load ranges. Conventionally, an huge LC passive filter is used in airconditioner to improve the power factor and to reduce current harmonics which doesn't give good results. In this paper, a design of active power factor correction(APFC)circuit for inverter airconditioner is described. To improve the P.F and reduce the current THD, average current controlled APFC is designed and tested. The problems of APFC implementation, their solution and testing results are described.

  • PDF

인버터 에어컨의 입력 역률 개선 및 하모닉 저감에 관한 연구 (A Study on the Input Power Factor Correction & THD Reduction of Inverter Airconditioner)

  • 김성환;이인호;유지윤;김태덕;배영돈;박윤서
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.235-237
    • /
    • 1995
  • The demands of minimizing the reactive power and reducing. the current harmonics are increasing nowadays. The inverter airconditioner needs high power and it operates with wide load range. Conventionally, ah huge LC passive filter is used in airconditioner to improve the P.F and to reduce current harmonics which doesn't gives good results. In this paper, a design of active power factor correction(PFC) circuit for inverter air conditioner is described. To improve the P.F and to reduce the THD, an average current controlled active PFC is designed and tested. Experimental results show that the developed system achieves almost unity P.F and low THD for all load range.

  • PDF

자동차 냉방기용 내부 풀리의 냉간 단조 공정 설계 (Process Design in Cold Forging of a lnner Cylindrical Pulley for Automobile Airconditioner)

  • 김동진;정덕진;김병민;최재찬
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1995년도 춘계학술대회논문집
    • /
    • pp.62-70
    • /
    • 1995
  • The inner pulley is automobile component used as airconditioner clutch assembly. in cold forging of the inner pulley . the design conditions are the same between inner length and outer length, the uniform hardness and the no shape change in inner fillet radius due toa piercing. In industries, the design of forging processes is performed based on an experience-oriented technology, that is, designer's experiences and expensive trial and error. Using the rigid -plastic finite element simulation, we propose the optimal process conditons and design of preform or redesign of final product shape without defects prodicted by metal flow, distribution fo strain, forging load during forging processes form initial workpiece to final product.

  • PDF

하계 피크전력 감소를 위한 냉방기제어시스템 개발 및 적용 (The development and implementation of airconditioner control system for peak load clipping)

  • 문홍석;조선구;이원빈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.783-787
    • /
    • 1996
  • The rapid growth of air conditioning load has become a main reason of peak load increase in summer. In connection with this, we surveyed the load management projects of utilities world wide and their detailed activities. This study is to develop a remote load control system using computer and radio communications. We finished the field-test of this system on August 1995 in Seoul area. During the field-test, the remote load control of air conditioners was proved to be well-timed. Two control modes, group control and all control, are available for the user to select. The transmission reliability of the load control signal was very good and the functions of system hardware as well as the software were excellent. So we confirmed the applicability of the load control system including the pager communication network. In this paper, detailed information on the system functions and experimental results are described.

  • PDF

큐잉모델에 기초한 자율 지능 부하 관리 시스템 연구 (A Study of Autonomous Intelligent Load Management System Based on Queueing Model)

  • 이승철;홍창호;김경동;이인용;박찬엄
    • 조명전기설비학회논문지
    • /
    • 제22권2호
    • /
    • pp.134-141
    • /
    • 2008
  • 본 논문은 전력회사와 수용가가 실시간으로 상호 협력하면서 효율적으로 여름철 냉방부하를 관리하여 첨두부하를 저감하기 위한 기법에 대하여 기술한다. 전력회사가 필요 관리량을 수용가 측에 요청하면 부하관리 요청을 받은 수용가, 예를 들면 대규모 아파트 단지의 중앙 지능관리 서버(Central Intelligent Management Server: CIMS)가 자율적인 관리를 통하여 요구받은 관리전력 이내로 부하율을 조정하도록 한다. 부하율을 관리하기 위한 수단으로CIMS는 필요 관리 부하전력에 따라 냉방기를 가동할 수 있는 권리에 해당하는 적정 수의 토큰(Token)을 발행하고 각 세대내의 냉방기를 제어할 수 있는 다수의 로컬 지능관리 서버(Local Intelligent Management Server: LIMS)들이 각 집안의 상황에 따라 냉방기를 가동하기 원할 경우에 전체 관리 서버에게 냉방기를 가동할 수 있는 권리에 해당하는 토큰을 요청하도록 한다. CIMS는 LIMS들의 토큰 요청을 관리하기 위한 큐(Queue)를 구성하여 관리하고 토큰을 요구한 각 LIMS들은 토큰을 할당받는 대로 자신이 담당하는 세대내의 냉방기를 가동하고 일정조건이 만족되면 자율 또는 타율로 토큰을 반납하여 큐에서 기다리는 다른 LIMS들에게도 토큰이 할당될 수 있도록 한다. 큐 운영 정책에 다양한 냉방기 운용 환경 정보를 반영하고 CIMS와 LIMS간에 원만한 상호 협력을 위하여 지능형 멀티 에이전트(Multi-Agent) 시스템으로 구성하고 이들을 계층구조의 네트워크로 연결하였다. 제안하는 기법을 서울의 한 아파트단지의 여름철 전력수요 데이터를 예로 하여 예상되는 대기 시간과 지원 받을 수 있는 전력요금 규모를 산정해 보았으며, 비교적 적은 수용가의 불편으로 큰 부하관리 효과를 얻을 수 있는 것을 알 수 있었다.