Size Characterization of Urban Airborne Particles Using Sedimentation/Steric Field-Flow Fractionation (Sd/StFFF)

  • Lee, Jae-Yong;Lee, Seung-Ho;Min, Young-Hong;Hyun, Dae-Yeung
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.8
    • /
    • pp.1172-1176
    • /
    • 2003
  • This study aims to investigate the applicability of Sd/StFFF and to develop a method for size characterization of urban airborne particles, focusing primarily on particles larger than about 1 mm. It was found that the airborne concentration vary with time, although no particular seasonal trend was observed. When averaged over time, the airborne concentration was the lowest in the park areas with 99 ㎍/m³. The apartment, industrial, and central city area showed similar levels of the airborne concentrations with 166, 170, and 171 ㎍/m³, respectively. The housing area showed the highest airborne concentration with 201 μg/m³ among all tested areas. A power-programmed Sd/StFFF was used for size analysis of airborne particles with the initial field strength of 300 rpm, $t_a$ = 4, $t_i$ = -16, p = 8, and the flow rate of 7 mL/min. It was found that urban airborne samples were mostly populated by particles having diameters between about 5 to 20 ㎛, although all have broad size distributions ranging up to about 50 ㎛. Under the Sd/StFFF condition used in this study, no significant differences were found in size distributions among the airborne particles collected at different urban sites, and also among those collected at different times.

Real -time Observation on Airborne Particles with Visual Impactor (입자의 실시간 관측이 가능한 임팩터의 설계 및 성능해석)

  • 육세진;안강호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.1
    • /
    • pp.67-76
    • /
    • 2003
  • Recently consideration of health and interest on bio aerosols have been growing steadily. In this study, inertial impactor, which can be used to collect airborne particles and bio aerosols, was newly devised for real-time observation on the particles collected on impaction plate. and named Visual Impactor. Flow field and particle trajectory in the space between nozzle and impaction plate was analyzed numerically, and the collection effciencies were calculated. Calibration and performance evaluation of the Visual Impactor was conducted with polydisperse aerosols generated from 0.1% sodium chloride solution. Cut-off diameter from numerical simulation was in good agreement with that from experimental results. Because of particle bounce and particle deposition on nozzle tip due to short jet-to-plate distance, the collection efficiencies from numerical and experimental analyses were different slightly. Visual Impactor was used to collect airborne particles, and the features of collected particles could be seen in real-time. Airborne particles in different weather conditions (fine, cloudy, and rainy) were sampled and compared one another The features of collected airborne particles were dependent strongly upon relative humidity. In addition, with hours elapsing, shapes and colors of collected particles were changed by evaporation and surface tension, etc.

A Detection of Airborne Particles Carrying Viable Bacteria in an Urban Atmosphere of Japan

  • Hara, Kazutaka;Zhang, Daizhou;Yamada, Maromu;Matsusaki, Hiromi;Arizono, Koji
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.3
    • /
    • pp.152-156
    • /
    • 2011
  • Viable bacteria on water-insoluble airborne particles were detected in the urban atmosphere of Kumamoto ($134^{\circ}45'E$, $32^{\circ}28'N$), Japan, in autumn 2008. Airborne particles were collected onto film-covered Cu meshes under clear weather conditions. The samples were stained by fluorescent stains, and then viewed and photographed with an epifluorescent microscope. Non-biological and bacterial parts in particles larger than 0.8 ${\mu}m$ were distinguished by their morphologies, fluorescent colors and fluorescent intensities. Bacterial viable statuses were discriminated according to cell membrane damage. In total, 2681 particles were investigated and it was found that 78 airborne particles were associated with bacteria. Viable bacteria were identified on 48 particles. A few particles carried multiple viable bacteria. These results provide the evidence that airborne particles act as carriers of viable bacteria in the atmosphere.

Measurement of Airborne Particles and Volatile Organic Compounds Produced During the Heat Treatment Process in Manufacturing Welding Materials

  • Myoungho Lee;Sungyo Jung;Geonho Do;Yeram Yang;Jongsu Kim;Chungsik Yoon
    • Safety and Health at Work
    • /
    • v.14 no.2
    • /
    • pp.215-221
    • /
    • 2023
  • Background: There is little information about the airborne hazardous agents released during the heat treatment when manufacturing a welding material. This study aimed to evaluate the airborne hazardous agents generated at welding material manufacturing sites through area sampling. Methods: concentration of airborne particles was measured using a scanning mobility particle sizer and optical particle sizer. Total suspended particles (TSP) and respirable dust samples were collected on polyvinyl chloride filters and weighed to measure the mass concentrations. Volatile organic compounds and heavy metals were analyzed using a gas chromatography mass spectrometer and inductively coupled plasma mass spectrometer, respectively. Results: The average mass concentration of TSP was 683.1±677.4 ㎍/m3, with respirable dust accounting for 38.6% of the TSP. The average concentration of the airborne particles less than 10 ㎛ in diameter was 11.2-22.8×104 particles/cm3, and the average number of the particles with a diameter of 10-100 nm was approximately 78-86% of the total measured particles (<10 ㎛). In the case of volatile organic compounds, the heat treatment process concentration was significantly higher (p < 0.05) during combustion than during cooling. The airborne heavy metal concentrations differed depending on the materials used for heat treatment. The content of heavy metals in the airborne particles was approximately 32.6%. Conclusions: Nanoparticle exposure increased as the number of particles in the air around the heat treatment process increases, and the ratio of heavy metals in dust generated after the heat treatment process is high, which may adversely affect workers' health.

Concentration Characteristics of Indoor and Outdoor Airborne Total Fiber Particles and Identification of Asbestos in Gyeongnam Provinces (경남지역의 실내외 공기 중 총섬유 입자의 농도특성 및 석면 입자의 확인)

  • Park, Hee-Eun;Park, Jeong-Ho;Kim, Hyoung-Kab
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.2
    • /
    • pp.119-127
    • /
    • 2012
  • Objectives: The aim of this study is to identify concentration characteristics of indoor and outdoor airborne total fiber particles and asbestos in Gyeongnam Provinces. Methods: This study investigated concentration characteristics of indoor fiber particles from 748 schools and 38 public facilities as well as outdoor particles from 11 sites through PCM (phase contrast microscope). SEM/EDX (scanning electron microscope/energy dispersive using X-ray analysis) was used to obtain physicochemical information of asbestos fiber particles. The study identified asbestos rate in the 15 samples from indoor and outdoor airborne total fiber particles. Results: 1. The average indoor airborne concentrations of total fiber particles were $0.0011{\pm}0007$ f/cc in schools and $0.0015{\pm}0007$ f/cc in public facilities by PCM. Over 90% of the fiber particles were identified as single fibers. 2. The average outdoor airborne concentrations of total fiber particles were $0.0007{\pm}0002$ f/cc, and they were lower than those of indoor airborne concentrations. 3. The results showed that the form of asbestiform was diverse as skein of thread like form and long needle, which was relatively narrower than that of glass fiber and rock wool. 4. The results of SEM/EDX analysis of 15 areas where total fiber particle was relatively high showed that the form was rather similar to that of asbestos, but chemical composition was proven to be non-asbestos. Conclusions: The concentration of indoor and outdoor airborne total fiber particles of Gyeongnam Provinces satisfied the IAQ (Indoor air quality) level of 0.01 f/cc and asbestos was not found in most of the samples by SEM/EDX.

Distribution of Airborne Microorganisms in Yellow Sands of Korea

  • Choi, Dae-Sung;Park, Yong-Keun;Oh, Sang-Kon;Yoon, Hee-Ju;Kim, Jee-Cheon;Seo, Won-Jun;Cha, Seung-Hee
    • Journal of Microbiology
    • /
    • v.35 no.1
    • /
    • pp.1-9
    • /
    • 1997
  • Distribution of airborne microorganisms was determined with two different types of air samplers, the Anderson cascade sampler and the Aerobioscope sampler, in the vicinity of Taejon. The size distribution of particles carrying bacteria and fungi was concurrently measured. The concentration of detected viable airborne particles was greatly varied. It was observed that the number of microbial particles increased in April and October. The most isze o particles carrying bacteria was larger than 4.7 .mu.m in mean aerodiameter, which made up 69.8% of the total particle fraction. About 63.2% of fungi-carrying particles were smaller than 4.7 .mu.m in aerodiameter. The distribution of particles on Yellow Sand Phenomena days was also analyzed. The number of fine particles having mass median aero-diameter from 1.0 to 10.mu.m increased on Yellow Sand Phenomena days to about 6 times that on normal days and the n umber of colony forming unit (CFU/$\textrm{m}^3$) of airborne bacteria also increased by 4.3 times in April. The reuslts from the Anderson sampler showed that the concentration of bacteria increased greatly on the fraction of fine particles ranging from 0.6 $\mu$m to 4.7 $\mu$m in diameter. Unlike the increase in bacterial floraon Yellow Sand Phenomena days, the fungal concentration slightly decreased and showed a normal size distribution parttern. This study suggests that a long-range transmission of bacteria results form bacteria adsorbing onto the fine particles during the Yellow Sand Phenomena.

  • PDF

Development of wet-sampler for collection and fractionation of micron-sized particles (마이크로 입자의 습식 수집 및 분획 장치 개발)

  • Eum, Chul-Hun;Kang, Dong-Young;Lee, Seung-Ho
    • Analytical Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.429-434
    • /
    • 2011
  • In this study, a wet-sampler was developed for collection in water and simultaneous fractionation of micron-sized particles (e.g., pigment, airborne, etc.). In this new device, three cylinders (partially filled with water) through which air was forced to pass for sample collection are connected in a series. Particles of different sizes are collected in different cylinders, allowing simultaneous fractionation. An uniqueness of this new device is that it does not use any membrane filter. Microparticles are collected directly in cylinders filled partially with water. Also the particles are simultaneously fractionated within this device while they are being collected. The new device was employed for collection of airborne particles. The collected airborne particles were fractionated by using sedimentation field-flow fractionation, SdFFF), and observed with an optical microscopy (OM) for size and shape analysis. Also AAS and ICP-AES were used for composition analysis of the airborne particles. It is expected that the new device is applicable to collection and analysis of size distribution of various types of microparticles.

A Study on the Particles Density Estimation in Seoul Metropolitan (서울시 미세먼지의 밀도 추정에 관한 연구)

  • Kim, Shin-Do;Kim, Chang-Hwan;Hwang, Ui-Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.2
    • /
    • pp.131-136
    • /
    • 2008
  • The variation of the particle size distribution and density as well as the chemical composition of aerosols is important to evaluate the particles. This study measured and analyzed airborne particles using a scanning mobility particle sizer (SMPS) system and an aerodynamic particle sizer (APS) at the University of Seoul during every season. The highest particle number concentration of airborne particles less than $0.9\;{\mu}m$, occurred in winter, while the highest particle number concentration of airborne particles more than $0.9\;{\mu}m$, occurred in spring. Mass concentration appeared highest at spring. Also, when we compared $\beta$-ray's mass concentration with calculated mass concentration by using the SMPS-APS system during each season, density of the winter is $1.92\;g/cm^3$, spring density is $1.64\;g/cm^3$, fall density is $1.57\;g/cm^3$. We found out that PM10 density was differ every season. However, while the calculated density is whole density for PM10 the density of each diameter was different. In this study the density estimation equation of the QCM cascade impactor measured mass concentration of each diameter.

Characterizations of Airborne Fiber Particle Concentrations in Public Facilities and Schools (다중이용시설 및 학교 교사내 실내공기중 섬유상 입자의 농도 특성)

  • Park, Jeong-Ho;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.19 no.4
    • /
    • pp.509-516
    • /
    • 2010
  • This study was investigated the characteristics of indoor air concentration of fiber particles in 30 public facilities and 245 schools by PCM (phase contrast microscopy). Also SEM/EDX (scanning electron microscope / energy dispersive using X-ray analysis) was used to obtain physicochemical information of asbestos fiber and to classify asbestos and non-asbestos of fiber particles. The airborne concentrations of fiber particles were $0.0009\pm0.0009$ counts/mL in public facilities and $0.0012\pm0.0006$ counts/mL in schools by PCM. All the samples were satisfied with the IAQ (indoor air quality) level of 0.01 counts/mL. In classification of 4 type shapes, over 80% of the fiber particles were identified as single fiber type. And this study analysed airborne fiber particles in 4 sites for identifying asbestos of by SEM/EDX. The asbestos fibers in most samples could not be found.

Characterization of Odorant Compounds from Mechanical Aerated Pile Composting and Static Aerated Pile Composting

  • Kumari, Priyanka;Lee, Joonhee;Choi, Hong-Lim
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.4
    • /
    • pp.594-598
    • /
    • 2016
  • We studied airborne contaminants (airborne particulates and odorous compounds) emitted from compost facilities in South Korea. There are primarily two different types of composting systems operating in Korean farms, namely mechanical aerated pile composting (MAPC) and aerated static pile composting (SAPC). In this study, we analyzed various particulate matters (PM10, PM7, PM2.5, PM1, and total suspended particles), volatile organic compounds and ammonia, and correlated these airborne contaminants with microclimatic parameters, i.e., temperature and relative humidity. Most of the analyzed airborne particulates (PM7, PM2.5, and PM1) were detected in high concentration at SAPC facilities compered to MAPC; however these differences were statistically non-significant. Similarly, most of the odorants did not vary significantly between MAPC and SAPC facilities, except for dimethyl sulfide (DMS) and skatole. DMS concentrations were significantly higher in MAPC facilities, whereas skatole concentrations were significantly higher in SAPC facilities. The microclimate variables also did not vary significantly between MAPC and SAPC facilities, and did not correlate significantly with most of the airborne particles and odorous compounds, suggesting that microclimate variables did not influence their emission from compost facilities. These findings provide insight into the airborne contaminants that are emitted from compost facilities and the two different types of composting agitation systems.