• Title/Summary/Keyword: Airborne endotoxin

Search Result 14, Processing Time 0.019 seconds

Comprehensive Review of Endotoxin Level Reported in Metalworking Operations (금속 가공유 취급 공정에서 엔도톡신 발생 및 노출 특성 고찰)

  • Park, Dong-Uk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.405-415
    • /
    • 2014
  • Objectives: The aim of this study is to comprehensively summarize endotoxin levels reported in operations using metalworking fluids(MWFs). Methods: An extensive literature review was conducted of studies reporting endotoxin levels in processes using metalworking fluids. Keyword search terms included 'metalworking fluids', 'machining fluids', 'metalworking operation', 'machining operation' and 'endotoxin', which were used in combination. Results: A total of ten manuscripts were found to report on airborne endotoxin levels from metalworking operations in the automobile industry. Polycarbonate(PC), polyvinyl chloride(PVC) and mixed cellulose ester(MCE) were used to collect airborne endotoxin. Limulus Amebocyte Lysate was mainly used to quantify endotoxin amount. The levels of airborne endotoxin reviewed varied considerably, ranging from < $4EU/m^3$ to $790EU/m^3$, which was found to be far lower than those from cotton and potato processing plants, sawmills, and poultry farms. Several studies assumed that exposure to endotoxin could be a causative agent of respiratory diseases. Conclusions: Inhalation endotoxin exposure levels reported from metalworking operations were found to be lower than those from industries handling organic materials, even though it could be considered as a possible cause for several respiratory diseases.

Evaluation of Environmental Circumstance Within Swine and Chicken Houses in South Korea for the Production of Safe and Hygienic Animal Food Products (일부지역 양돈장 및 양계장 공기중 박테리아, 진균, 내독소 농도)

  • Kim, Young-Hwan;Suh, Hyung-Joo;Kim, Jin-Man;Jung, Yeon-Hoon;Moon, Kyong-Whan
    • Food Science of Animal Resources
    • /
    • v.28 no.5
    • /
    • pp.623-628
    • /
    • 2008
  • This study was undertaken to determine the concentrations of airborne bacteria, fungi, particles, and endotoxin in swine and chicken houses. Six swine buildings and seven chicken houses were randomly selected in southern Gyonggi Province, South Korea. The geometric mean concentrations of airborne bacteria in swine and chicken houses were $2.7{\times}10^5\;CFU/m^3$ and $5.6{\times}10^7\;CFU/m^3$, respectively. The airborne bacteria concentrations in chicken houses were significantly higher than those of swine houses (p<0.05). The geometric mean concentration of airborne fungi in swine houses was $4.9{\times}10^3\;CFU/m^3$, which was higher than the value of $2.1{\times}10^3\;CFU/m^3$ found in chicken houses. The mean concentrations of airborne particles and endotoxin in swine houses were $3.48\;mg/m^3$ and $943.1\;EU/m^3$, and they were $15.43\;mg/m^3$ and $1,430.5\;EU/m^3$ in chicken houses, respectively. A significant difference between swine and chicken houses was found for total dust (p<0.05), but not for endotoxin. In this study, the concentrations of endotoxin in both swine and chicken houses as well as particles in chicken houses were high, and in about 50% of the samples exceeded the worker health safety levels of $614\;EU/m^3$ suggested in previous studies. These results may indicate a considerable respiratory hazard for workers in these environments.

Exposure Assessment for Airborne Biological Agents in Sawmills (제재업의 생물학적인자 노출실태 평가)

  • Park, Hae-Dong;Park, Hyun-Hee;Lee, In-Seop
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.4
    • /
    • pp.274-281
    • /
    • 2010
  • The objectives of this study are (a) to investigate the distribution patterns and exposure concentrations of biological agents in sawmill industries and (b) to compare sampling methods of biological agents. The representative processes of 5 sawmills were selected to measure total airborne bacteria, fungi, endotoxin as well as dust. Airborne bacteria and fungi were measured with one stage impactor, six stage impactor and gelatin filteration methods. Endotoxin was collected with polycarbonate filters and analysed by kinetic chromogenic Limulus Amebocyte Lysate method. Geometric mean levels of airborne bacteria, fungi, endotoxin and dust were 1,864 CFU/$m^3$, 2,252 CFU/$m^3$, 31.5 EU/$m^3$ and 2.4 mg/$m^3$. The ratios of indoor/outdoor concentrations were 3.7 for bacteria, 4.1 for fungi, 3.3 for endotoxin and 9.7 for dust. The respiratory fractions of bacteria were 68.0, 50.9, 49.2 and 45.1% in band-saw, table-saw, rip-saw process and outdoor air. The respiratory fractions of fungi were 78.7, 90.8, 87.5 and 84.8% in band-saw, table-saw, rip-saw process and outdoor air, respectively. There was no significant differences in bacterial concentrations among single stage, six stage impaction and filteration methods. But, fungal concentrations measured with filtration methods were significantly higher than those with impaction methods. Geometric mean levels of airborne bacteria and fungi were higher than the OSHA guideline values of 1,000 CFU/$m^3$. The respiratory fractions of fungi were above 75%. The concentrations of biological agents were significantly different among culture-based sampling methods. In the exposure assessments of biological agents, further studies are needed for the comparisons of diverse sampling methods and the investigations of environmental factors.

Effect of Mechanical Agitation on Generation of Airborne Bacteria and Endotoxin in Exhaust Gases from Lab-Scale Composting of Sewage Sludge (실험실 규모 하수슬러지 퇴비화공정에서 기계적 교반이 배출가스 내 부유세균과 내독소의 발생특성에 미치는 영향)

  • Kim, Ik-Hyeon;Kim, Ki-Youn;Phae, Chae-Gun;Kim, Dae-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.3
    • /
    • pp.143-148
    • /
    • 2012
  • This study was performed to investigate the concentration variation of airborne bacteria and endotoxin by the temperature in the compost pile in order to identify the generation characteristics of biological factors in the exhaust gases generated from lab-scale sludge compositing reactors (0.06 $m^3$ of total reactor volume). Airborne bacteria showed the highest concentration of generation ($1.03{\times}10^5\;CFU/m^3$) in the composting reactor without mechanical agitation, and similar change tendency to temperature variation of composting, but somewhat lower statistical significance (p>0.05). In the compost reactor with mechanical agitation, endotoxin showed similar generation characteristic to temperature variation of composting (statistical significance; p<0.05) and the highest generation concentration to 1,415 EU/$m^3$. Mechanical agitation of the composting process affected activity of microorganism and positive generation of endotoxin in exhaust gases. Endotoxin and airborne bacteria showed similar tendency of generation, especially the highest statistical correlation was observed in the compost reactor without mechanical agitation (statistical significance: p<0.01).

An Assessment of Environmental Characteristics Associated with the Level of Endotoxin Concentration in Hospital Lobbies (일부 종합 병원 로비의 공기 중 엔도톡신 농도에 미치는 환경 요인 평가)

  • Lee, Kyeong-Min;Yeom, Jeongkwan;Lee, Wonjae;Ryu, Seung-Hun;Park, Dongjin;Park, Dong-Uk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.3
    • /
    • pp.310-320
    • /
    • 2014
  • Backgrounds: Endotoxin, which found in the outer membrane of the gram-negative bacteria cell wall, makes up almost all of the lipopolysaccharide(LPS). When people are exposed to endotoxin,it can result in diverse health effects such as an airway irritation and inflammation, fever, malaise, bronchitis, allergic asthma, toxic pneumonitis, hypersensitivity lung disease. Cases among the elderly, children or pregnant can occur more frequently than a healthy adult if they are repeatedly exposed to the existing endotoxin. Therefore, we investigated and assessed the environmental characteristics associated with the airborne endotoxin concentration level in six hospital lobbies. Method: Endotoxin from indoor air in six hospital lobbies was measured by an area sampling method and analyzed according to American Society for Testing and Materials International(ASTM international) E2144-01. Total suspended particulate(TSP), carbon dioxide($CO_2$), temperature and humidity were also measured by using direct reading measurements or airborne sampling equipment at the same time. Environmental characteristics were appropriately divided into two or three groups for a statistics analysis. One-way analysis variable(one-way ANOVA) was used to examine a difference of the endotoxin concentration, depending on the environmental characteristics. In addition, only variables with p-value(p<0.25) were eventually designed to the best model by using multiple regression analysis. Results: The correlation analysis result indicated that TSP(p=0.003) and $CO_2$(p<0.0001) levels were significantly associated with endotoxin concentration levels. In contrast, temperature(p<0.068) and humidity(p<0.365) were not associated with endotoxin concentration. Levels of endotoxin concentration were statistically different among the environmental characteristics of Service time(p=0.01), Establishment of hospital(p<0.001), Scale of hospital(p=0.01), Day average people using hospital(p=0.03), Cleaning time of lobby(p=0.05), Season(p<0.001), and Cleaning of ventilation system(p<0.001) according to ANOVA. Finally, the best model(Adjusted R-square=72%) that we designed through a multiple regression test included environmental characteristics related to Service time, Area of lobby, Season, Cleaning of ventilation system, and Temperature. Conclusions: According to this study, our result showed a normal level of endotoxin concentration in the hospital lobbies and found environmental management methods to reduce the level of endotoxin concentration to a minimum. Consequently, this study recognized to be requirement for the management of ventilation systems and an indoor temperature in order to reduce the level of endotoxin concentration in the hospital lobbies.

Microbial Assessment in Metal-Working Fluids Handling Industry (금속가공유 취급 작업장의 생물학적 인자 노출평가)

  • Park, Hyunhee;Park, Dongjin;Park, Hae Dong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.3
    • /
    • pp.300-309
    • /
    • 2014
  • Objectives: The objective of this study is to evaluate microbial exposure hazards in the metal-working fluids(MWF) handling industry. Methods: Air quality parameters(airborne bacteria, fungi, endotoxin and oil mist) and bulk MWF in storage tanks were evaluated at 54 points at nine sites in South Korea. Results: The geometric means(GM) of culturable airborne bacteria, fungi, endotoxin and oil mist concentration were $133CFU/m^3$(n=376, range $7{\sim}6,510CFU/m^3$), $159CFU/m^3$(n=381, range $7{\sim}8,469CFU/m^3$), $8.06EU/m^3$(n=103, range $0.34{\sim}280.4EU/m^3$) and $0.20mg/m^3$(n=104, range $0.01{\sim}2.87mg/m^3$), respectively. The ratio of indoor to outdoor concentration was 2.7 for bacteria, 6.1 for endotoxin, and 4.8 for oil mist. Even though average airborne bacteria concentration did not exceed recommended exposure limits($1,000CFU/m^3$), MWF in the storage tanks was highly contaminated with bacteria(arithmetic mean $2.1{\times}10^6CFU/ml$) and exceeded recommended bacteria limits($10^5CFU/ml$). Conclusions: It is necessary for MWF handling workplaces to conduct periodical biohazard inspection of MWF storage tanks. Additionally, further research may be necessary to establish biological occupational exposure limits.

Secular Trend in Indoor Dust Levels with a Comparison of Indoor and Exhaust Outlet Dust Levels in Swine Confinement Buildings (비육돈사 공기중 분진 수준에 대한 시계열적 분석 및 돈사내외부 분진 수준 비교분석)

  • Kim, HyoungAh;Kim, ChangYul;Gautam, Ravi;Yang, SuJeong;Acharya, Manju;Jo, JiHoon;Maharjan, Anju;Sin, SoJung;Song, EunSeob;Lee, YoonBum;Kim, Hyocher;Kim, Kyung-ran;Lee, Kyung-suk;Heo, Yong
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.6
    • /
    • pp.630-637
    • /
    • 2019
  • Objectives: This study was performed to evaluate the secular changes in indoor airborne dust or endotoxin levels in the dust from swine confinement buildings. Indoor levels were compared with the level at the exhaust outlet in order to examine the contribution potential of indoor dust to nearby ambient air dust. Methods: Comparisons were made on inhalable and respirable dust levels reported in 2002, 2012, and 2017 from 14, 10, and 36 swine fattening confinement buildings in Korea, respectively. This data was produced by the same research group. Levels of endotoxin adsorbed into inhalable or respirable dust were also compared. Samples of inhalable or respirable dust were collected indoors and at exhaust outlets from 17 swine fattening confinement buildings in 2019, and dust levels were compared between the indoor and the outlet. Results: The outlet inhalable dust level (0.111 mg/㎥) was approximately 19% of that from indoors, and the respirable dust level (0.033 mg/㎥) was approximately 74% of that from indoors. The outlet respirable dust levels were lower than the airborne fine dust levels in the towns where those farms are located. No significant difference was observed in the inhalable dust levels among the years examined, but the respirable dust level in 2017 (0.143 mg/㎥) was significantly lower than in 2002 (0.328 mg/㎥). The level of endotoxin in inhalable dust was significantly higher in 2017 (722 EU/㎥) than in both 2002 (75 EU/㎥) and 2012 (171 EU/㎥). Conclusion: Even though no apparent contribution from swine farm indoor dust to nearby ambient air dust was observed in terms of amount, a certain control strategy to reduce the production of airborne dust and endotoxin from swine farms is merited.

A Study on the Biological Hazards Exposure for Waste Handling Industries in Korea (국내 폐기물 취급업의 생물학적 인자 노출실태)

  • Park, Hyunhee;Park, Hae Dong;Lee, Inseop
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.4
    • /
    • pp.265-275
    • /
    • 2012
  • Objectives: The aim of this study was to investigate the distribution patterns and exposure concentrations of biological hazards in waste handling industries. Methods: We selected 3 recyclable waste sorting plants(RWS), 2 food recycling plants(FR), 1 landfill area(LA) and 1 waste incineration plant(WI). Total airborne bacteria and fungi were measured with single stage impactor and gelatin filters. Endotoxin and glucan were measured with polycarbonate filters in total and respirable dust. Results: The geometric mean of airborne bacterial concentration was the highest in FR($3,273CFU/m^3$), followed by LA, RWS, and WI as 1,334, 934, and $860CFU/m^3$. The fungal concentrations were 6,031, 5,052, 3,307, and $713CFU/m^3$ in RWS, WI, FR, and LA, respectively. By process, WI pit showed the highest concentrations of bacteria, fungi, and endotoxin, followed by inside of bulldozer in LA. The indoor to outdoor ratios of bacteria, fungi, endotoxin and glucan were 2.3, 4.0, 2.3, and 5.0 in RWS, 29.5, 4.9, 7.6, and 5.0 in FR, 5.3, 8.7, 26.8, and 9.5 in WI, respectively. Conclusions: We found that biological hazards, specifically bacteria in FR, fungi in RWS and endotoxin in WI pit and bulldozer at LA, should be controlled to prevent worker's respiratory diseases.

Exposure Assessments on Biological Contaminants in Homes of Allergy Patients - Bacteria, Fungi, House Dust Mite Allergen and Endotoxin (알레르기 환자 가정에서 생물학적 유해인자에 대한 노출평가 -세균, 진균, 집먼지 진드기 알레르겐, 내독소를 대상으로)

  • Moon Kyong Whan;Byeon Sang Hoon;Choi Dal Woong;Kim Young Whan;Lee Jang Hee;Lee Eun Il
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.2 s.83
    • /
    • pp.120-126
    • /
    • 2005
  • To assess exposure of allergy patients to a biological environment, measurements were made of levels of airborne bacteria and fungi, house dust endotoxin and mite allergens in homes of 7 allergy patients and 12 healthy families. Concentrations of airborne total bacteria and the ratio of indoor and outdoor concentrations(I/O) in allergy patient's homes were high compared to non-allergy houses. But no significant differences could be shown for the concentration of spores of viable fungi and staphylococcus in indoor air between the homes of allergic patients and healthy families. The results of investigation on house dust mites, Dermatophagoids farinae were detected in all mattress samples and the levels in the allergy patient's homes were generally high, with individual measurements exceeding $2{\mu}g/g$ dust found in $30\%$ samples. In contrast with, Dermatophagoids pteronyssinus were detected in only $60\%$ samples and the concentrations were very low. The levels of endotoxin in dust samples collected from the allergy patient's home mattresses were higher than those of control houses. There was a positive correlation between the endotoxin levels and the house dust mite allergens.

Research on Exposure to Total Dust and Endotoxin during Planting and Harvest Tasks at Cucumber, Yellow Melon and Potato Farms (오이, 참외, 감자 작목에서의 정식, 수확작업시 총분진과 엔도톡신 노출 특성에 관한 연구)

  • Kim, Hyo Cher;Lee, Kyung Suk;Chae, Hye Seon;Min, Kyung Doo;Kim, Kyung Ran;Park, Yoon Suk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.4
    • /
    • pp.412-420
    • /
    • 2013
  • Objectives: This study was conducted in order to evaluate personal and area exposure to airborne total dust and endotoxin during harvest and planting tasks at cucumber, yellow melon and potato farms Materials and Methods: Total dust was measured with NIOSH method 0500. Endotoxin were measured using a 37 mm glass fiber filter which was connected to an air pump calibrated to 2 LPM, and then analyzed with a Turbidmetric kinetic method. Results: The average(arithmetic mean) concentrations of total dust in the personal samples were $0.10-3.81mg/m^3$ for cucumbers, $0.21-1.19mg/m^3$ for yellow melon, and $0.08-2.72mg/m^3$ for potato. There was a significant difference in the harvest task among the three farm types(p=0.019 of personal sample, p=0.048 of area sample), in which the air concentration for potatoes was higher than with cucumbers and yellow melons. Conclusions: It was found that potatoes(planting and harvest) should be considered the first priority for studying and reducing total dust exposure.