• Title/Summary/Keyword: Airborne Bacterial

검색결과 47건 처리시간 0.021초

부산시 일부 지하상가 공기중 부유 균주 (Airborne Microorganisms of Some Underground Shops in Pusan)

  • 이용환;정석훈;고광욱;김영기;변주현
    • 생명과학회지
    • /
    • 제10권1호
    • /
    • pp.74-78
    • /
    • 2000
  • This study was investigated to evaluate the distribution of airborne microorganisms at underground shops in Seomyun and Nampodong, Pusan. The number of bacterial colonies on the nutrient agar plate plates were calculated by the open petri dish method for 30 minutes in indoor air of underground shops at every seasons in a year. There was no statistically significant difference between Seomyun and Nampodong in mean colony counts. Isolation rates of Gram positive rods was highest, and Gram positive cocci and Gram negative rods were followed. In Nampodong underground shops, Enterobacteriaceae strains was isolated. Mean colony counts according to seasons was higher at summer and autumn in Seomyun, and spring and winter in Nampodong. In near future, a study on the distribution of bacteria causing respiratory infection should be followed.

  • PDF

일부 학교 내 총부유세균 및 미세먼지의 상관성 비교 (Comparison of Correlation between Total Airborne Bacteria and Particulate Matter in University Spaces)

  • 서혜경;안하림
    • 한국산업보건학회지
    • /
    • 제34권2호
    • /
    • pp.115-124
    • /
    • 2024
  • Objectives: The aim of this study is to assess indoor air quality within and around buildings and evaluate the health risks associated with exposure to indoor air pollution. The study compares IAQ standards established by the World Health Organization with those set by South Korea's Ministry of Environment and Ministry of Education. Methods: The study utilized an Anderson Sampler and DustTrakTM II to collect samples of total airborne bacteria and PM in indoor and outdoor environments. Collected samples were analyzed using biological and biochemical methods. Statistical analysis was conducted using SPSS to examine the correlation between airborne bacteria and PM. Results: The study revealed that the concentration of total airborne bacteria in indoor air generally remained below the Ministry of Environment's standard of 800 CFU/m3, although it surpassed this threshold in certain instances. PM concentrations did not exceed the standards. Indoor fine dust concentration was higher when there were people (P<0.05). There was no difference in total floating bacterial concentrations between indoor and outdoor environments (P=0.184). Finally, there was a correlation between fine dust and airborne bacteria concentrations. Conclusion: The study evaluated the concentrations of total airborne bacteria and PM in indoor air, emphasizing the importance of managing IAQ. Further research in various environments is essential to ensure a healthy indoor environment. The findings underscore the need for ongoing research and management to enhance IAQ and create safer and healthier living environments.

서울시내 종합 병원 공기중의 미생물 분포 (Distribution of Hospital Airborne Microorganisms in Seoul, Korea)

  • Hong, Jun-Bai;Chung, Yun-Hee;Yun hee Chang
    • 한국환경보건학회지
    • /
    • 제29권1호
    • /
    • pp.1-7
    • /
    • 2003
  • 서울에 위치한 20개 종합병원의 중환자실, 일반병동 입원실, 환자대기실과 병원 실외 4곳 공기중의 일반 세균수와 곰팡이수를 측정하였으며, 기회 감염균을 검출하였다. 97-410 cfu/㎥의 일반세균수와 37-77 cfu/㎥의 진균이 검출되었으며 중환자실이 가장 낮은 미생물의 오염도를 보였으며 환자대기실이 가장 높은 오염도를 나타내었다. 18종의 진균이 분리되었으며 Aspergillus spp.가 가장 높은 빈도로 검출되었으며, 그 다음으로 Penicillium, Alternaria, Cladosporium 속 등이 검출되었다. Staphylococcus spp. 중에서는 S. haemolyticus와 S. epidermis가 가장 높은 빈도로 검출되었으며 검출된 Staphylococcus spp. 중 47%가 중환자실에서 검출되었다.

Fungal Distribution of the Janggyeong Panjeon, the Depositories for the Tripitaka Koreana Woodblocks in the Haeinsa Temple

  • Hong, Jin Young;Kim, Young Hee;Lee, Jeong Min;Kim, Soo Ji;Park, Ji Hee
    • 보존과학회지
    • /
    • 제38권1호
    • /
    • pp.64-71
    • /
    • 2022
  • Many investigations have been conducted on the biological damage and environmental conditions necessary to preserve the Janggyeong Panjeon and Daejanggyeongpan (woodblocks). We performed a survey on the concentration and diversity of airborne fungi in the Janggyeong Panjeon and compared them with the results of a survey from 2012. The temperature of the Beopbojeon building was slightly lower, while the relative humidity was higher than those found at the Sudarajang building. The concentration of airborne fungi in the Beopbojeon was 1.44-fold that of the Sudarajang. It was confirmed that the concentration and diversity of airborne fungi in the Janggyeong Panjeon differed depending on the sampling site. In total, 23 fungal genera were identified from the air samples, and 11 fungal and 1 bacterial genera were identified from the surface of the woodblocks. Among these, only five types of fungi were commonly distributed in the indoor air and surface of the Daejanggyeongpan; however, 58.3% of the fungi identified on the surface of the woodblocks were not observed in the in the air samples. The surface-dwelling fungi may accumulate dust to form microbial communities over time.

초등학교 실내환경에서 공기 중 세균과 진균의 분리 및 특성 (Isolation and Characterization of Airborne Bacteria and Fungi in Indoor Environment of Elementary Schools)

  • 김나영;김영란;김민규;조두완;김종설
    • 미생물학회지
    • /
    • 제43권3호
    • /
    • pp.193-200
    • /
    • 2007
  • 울산 소재 초등학교 3곳의 교실과 복도에서, 배양가능한 공기중 세균과 진균의 농도를 조사하고, 이들 미생물을 분리한 후 동정하였다. 세균과 진균의 포집에는 충돌식 공기 채취기를 사용하였으며, 세균수와 진균수의 측정에는 각각 plate count agar와 dichloran rose bengal chloramphenicol agar를 사용하였다. 학기 중 세균 농도는 교실에서 $168{\sim}3,887MPN/m^3$ 복도에서 $168{\sim}6,339MPN/m^3$의 범위였으며, 진균 농도는 교실에서 $34{\sim}389MPN/m^3$, 복도에서 $91{\sim}507MPN/m^3$의 범위로, 상황과 학교에 따른 측정값의 편차는 세균에서 진균보다 더 크게 나타났다. 분리한 세균의 84%는 그람양성으로 관찰되었는데, 전체 시험한 세균의 61%는 Micrococcus 속으로, 이중 75%는 M. luteus로 확인되었으며, Staphylococcus속은 전체의 10%수준이었다. Micrococcus 속의 주요 발생원은 사람으로 생각되며, 함유한 색소나 높은 세포벽 함량 등의 생리적 특징이 이들 세균의 공기중 생존력을 높이는 것으로 추측된다. 포집한 시료로부터 15속의 사상성 진균을 확인할 수 있었으며, Cladosporium 속, Aspergillus 속, Penicillium속 등이 분리한 진균의 69%를 차지하였다. 1개 학교의 교실에서는 Stachybotrys속이 검출되었는데, 이 속의 S. chartarum은 많은 진균독소를 생산하는 것으로 잘 알려져 있다. 독소생산과 관련이 깊은 Aspergillus 속, Penicillium속, Stachybotrys 속에 대한 종 수준에서의 동정, 분리한 진균의 독소생산능력, 공기중 진균독소 검출 및 진균 농도와의 상관관계 분석 등에 대한 보다 체계적인 연구가 필요하다고 판단된다.

제재업의 생물학적인자 노출실태 평가 (Exposure Assessment for Airborne Biological Agents in Sawmills)

  • 박해동;박현희;이인섭
    • 한국산업보건학회지
    • /
    • 제20권4호
    • /
    • pp.274-281
    • /
    • 2010
  • The objectives of this study are (a) to investigate the distribution patterns and exposure concentrations of biological agents in sawmill industries and (b) to compare sampling methods of biological agents. The representative processes of 5 sawmills were selected to measure total airborne bacteria, fungi, endotoxin as well as dust. Airborne bacteria and fungi were measured with one stage impactor, six stage impactor and gelatin filteration methods. Endotoxin was collected with polycarbonate filters and analysed by kinetic chromogenic Limulus Amebocyte Lysate method. Geometric mean levels of airborne bacteria, fungi, endotoxin and dust were 1,864 CFU/$m^3$, 2,252 CFU/$m^3$, 31.5 EU/$m^3$ and 2.4 mg/$m^3$. The ratios of indoor/outdoor concentrations were 3.7 for bacteria, 4.1 for fungi, 3.3 for endotoxin and 9.7 for dust. The respiratory fractions of bacteria were 68.0, 50.9, 49.2 and 45.1% in band-saw, table-saw, rip-saw process and outdoor air. The respiratory fractions of fungi were 78.7, 90.8, 87.5 and 84.8% in band-saw, table-saw, rip-saw process and outdoor air, respectively. There was no significant differences in bacterial concentrations among single stage, six stage impaction and filteration methods. But, fungal concentrations measured with filtration methods were significantly higher than those with impaction methods. Geometric mean levels of airborne bacteria and fungi were higher than the OSHA guideline values of 1,000 CFU/$m^3$. The respiratory fractions of fungi were above 75%. The concentrations of biological agents were significantly different among culture-based sampling methods. In the exposure assessments of biological agents, further studies are needed for the comparisons of diverse sampling methods and the investigations of environmental factors.

Distribution of Airborne Microorganisms in Yellow Sands of Korea

  • Choi, Dae-Sung;Park, Yong-Keun;Oh, Sang-Kon;Yoon, Hee-Ju;Kim, Jee-Cheon;Seo, Won-Jun;Cha, Seung-Hee
    • Journal of Microbiology
    • /
    • 제35권1호
    • /
    • pp.1-9
    • /
    • 1997
  • Distribution of airborne microorganisms was determined with two different types of air samplers, the Anderson cascade sampler and the Aerobioscope sampler, in the vicinity of Taejon. The size distribution of particles carrying bacteria and fungi was concurrently measured. The concentration of detected viable airborne particles was greatly varied. It was observed that the number of microbial particles increased in April and October. The most isze o particles carrying bacteria was larger than 4.7 .mu.m in mean aerodiameter, which made up 69.8% of the total particle fraction. About 63.2% of fungi-carrying particles were smaller than 4.7 .mu.m in aerodiameter. The distribution of particles on Yellow Sand Phenomena days was also analyzed. The number of fine particles having mass median aero-diameter from 1.0 to 10.mu.m increased on Yellow Sand Phenomena days to about 6 times that on normal days and the n umber of colony forming unit (CFU/$\textrm{m}^3$) of airborne bacteria also increased by 4.3 times in April. The reuslts from the Anderson sampler showed that the concentration of bacteria increased greatly on the fraction of fine particles ranging from 0.6 $\mu$m to 4.7 $\mu$m in diameter. Unlike the increase in bacterial floraon Yellow Sand Phenomena days, the fungal concentration slightly decreased and showed a normal size distribution parttern. This study suggests that a long-range transmission of bacteria results form bacteria adsorbing onto the fine particles during the Yellow Sand Phenomena.

  • PDF

일부 어린이집의 실내공기 중 메치실린내성 포도알균의 오염 실태 및 특성 (A Study on the Concentration and Characteristics of Methicillin-resistant Staphylococci in the Indoor Air of Childcare Facilities)

  • 김종오;김영진
    • 한국환경보건학회지
    • /
    • 제39권5호
    • /
    • pp.447-455
    • /
    • 2013
  • Objectives: This study aims to understand the concentration, diversity, and antibiotic characteristics of staphylococci present in the indoor air of child-care facilities. Methods: Air sampling was performed from October 2012 to January 2013 in 120 child-care facilities in Seoul, Korea. Methicillin-resistant bacteria were selected from the total obtained airborne bacteria and subjected to 16S rRNA analysis for methicillin-resistant staphylococcal species determination. Identified staphylococcal strains were tested for resistance to a range of antibiotics. Results: Average total airborne bacterial concentration was $508.9{\pm}246.3CFU/m^3$. Indoor concentration of total airborne bacteria had a significant positive correlation with the $CO_2$ concentration in the child-care facilities. Methicillin-resistant staphylococci were present in 13.3% of the child-care facilities studied. A total of four species (S. epidermidis, S. cohnii, S. saprophyticus, S. sp.) and 55 strains were identified from the indoor air of the child-care facilities. Staphylococcus cohnii was the most common species (54.5%), followed by S. epidermidis (38.2%). All of the isolated staphylococcal strains exhibited high resistance to oxacillin, erythromycin, mupirocin, and ceftizoxime. Especially, S. saprophyticus strains showed more multidrug resistance to oxacillin, vancomycin, clindamycin, erythromycin, lincomycin, ceftizoxime, mupirocin, and tetracycline than did other species. Conclusion: The results of this study showed that a monitoring system for multidrug-resistant bacteria is needed in facilities for children, as the community-associated infections of these bacteria are increasing.

대학 구내식당 식품위생환경의 세균오염도 조사연구 (A Study on Bacterial Contamination of Cooking Environments of Food Service Operations at University)

  • 박성준;윤현선;이수진;양민지;권보미;이정훈;고광표
    • 한국환경보건학회지
    • /
    • 제40권2호
    • /
    • pp.88-97
    • /
    • 2014
  • Objectives: The aim of this study was to evaluate the occurrence of microbiological contamination of kitchen utensils and environments of food service operations at university located in Seoul, Korea. Methods: We collected swab samples from the surfaces of knives, chopping boards, floors, and drains, as well as drinking water and airborne bacteria samples from 20 food service operations. Three bacterial indicators and five food poisoning bacteria were measured quantitatively and qualitatively, respectively. We used selective culture media and the PCR assay targeting 16S rRNA gene for the microbiological analysis. Results: We detected bacterial indicators on knives or chopping boards in eight different food service operations and, three food service operations (I, M, and O) showed more than 3 log colony forming units $(CFU)/100cm^2$ on their knives, significantly higher than the others. The levels of bacterial indicators on the floors and drains in the cooking areas were much higher than those on the cooking utensils. S. aureus was detected on 10 floors and 8 drains. Culturable bacteria were identified in 5 drinking water samples, and food service operation B ($431.1CFU/m^3$) and C ($551.2CFU/m^3$) showed more than $400CFU/m^3$ of total airborne bacteria. Conclusions: These results suggest that some of food service operations in this study may require additional investigation to secure the microbial safety of cooking environments. In addition, further actions including hygiene education for employees and proper guidelines to maintain clean cooking environments should be prepared.