• 제목/요약/키워드: Air-leakage rate

검색결과 144건 처리시간 0.026초

종이 물성에 따른 판형 전열교환기의 성능 (Performance of a Plate-Type Enthalpy Exchanger Made of Papers Having Different Properties)

  • 김내현;조진표;송길섭;김동훈
    • 설비공학논문집
    • /
    • 제20권8호
    • /
    • pp.547-555
    • /
    • 2008
  • The effects of paper properties such as density, air permeability, water vapor transmission rate on the thermal performance of plate-type enthalpy exchanger were experimentally investigated. Papers having different properties were made from the same pulp by calendering or refining. Enthalpy exchanger samples were made from the papers, and were tested according to the standard test procedure (KS B 6879). Effective efficiencies were obtained, which accounted for the air leakage between supply and exhaust streams. Results showed that paper density affected the sensible heat transfer of the samples. Sensible heat transfer increased with density of the paper. It was also shown that effective efficiency of latent heat transfer was approximately the same independent of the samples, which suggests that papers made of the same pulp show similar water vapor transmission characteristics independent of the degree of calendering or refining. Best performance was obtained for the sample having highest paper density and moderate water vapor transmission ratio.

실차를 이용한 자동차 에어컨 냉매 누출량 평가 (Measurement of R-134a Leakage from Vehicle Equipped Mobile Air Conditioning(MAC) System)

  • 김지영;서충열;이상은;김정수
    • 한국기후변화학회지
    • /
    • 제3권2호
    • /
    • pp.153-159
    • /
    • 2012
  • 자동차 에어컨 냉매로 사용되어온 CFC-12는 1991년부터 1994년에 걸쳐 HFC 계열의 냉매인 R134a로 대체되었으며, R-134a는 현재자동차 에어컨 냉매로 널리 사용되고 있다. 그러나 R-134a는 지구온난화 지수(GWP)가 1,300으로 매우 높으며, 교토의정서에서 정한 6대 온실가스 중에 하나로 포함되어 누출량 관리 및 대체 냉매 개발이 필요한 실정이다. 본 연구에서는 자동차에서 배출되는 $non-CO_2$ 온실가스 배출량 산출을 위한 기초연구로 실차 상태에서의 에어컨 냉매 누출량을 분석하기 위하여 가변온도밀폐실(VT shed)과 Running loss test shed를 이용하여 R-134a의 농도변화를 측정하였다. 대상차종에 대한 주차상태에서 R-134a 누출량을 분석한 결과, 연간 누출량이 6.46~13.28 g/yr 수준으로 기존의 에어컨 시스템을 이용한 누출량 분석결과와 유사한 수준으로 분석되었다. 동일 모델 차량에 단일증발기를 적용한 차량과 이중증발기를 적용한 차량에 대해 냉매 누출량을 비교한 결과, 단일증발기로 구성된 에어컨이 적용된 차량에 비하여 이중증발기가 적용된 에어컨이 장착된 차량에서 누출량이 높게 나타났다. 이는 이중증발기 적용에 따라 에어컨 시스템 구성시 연결부위(호스, 접합부 등)가 추가되면서 해당 부위에서의 누출이 증가된 것으로 보인다. 또한, 차속별 R-134a 농도변화를 분석한 결과, 고속주행시(100 km/hr) 냉매 누출이 증가하였으며, 송풍량 증가에 따른 누출량 변화는 나타나지 않았다.

Dosimetrical Analysis of Reactor Leakage Gamma-rays by Means of Scintillation Spectrometry

  • Jun, Jae-Shik
    • Nuclear Engineering and Technology
    • /
    • 제5권4호
    • /
    • pp.291-309
    • /
    • 1973
  • TRIGA Mark II와 III 원자로의 여러가지 가동조건에 있어서 노벽으로 부터의 누설 ${\gamma}$선에 의한 조사선양률을 3"$\times$3"원통형 NaI(T1) 섬광계수기와 400 channel파 고분석장치로 측정하였는데 측정된 spectrum으로부터 조사선양률을 산출하는데는 실제적면에서 복잡하기 짝이 없는 response matrix 방법대신 정도가 좋으면서도 비교적 그 과정이 단순한 Moriuchi의 specturm -조사선양률 환산 이론을 적용하였다. 연구결과에 따르면 노심에서 발생된 누설 ${\gamma}$선의 기본적인 spectrum 형태는 원자로의 열출력이나 차장벽에 의한 강도의 감쇠에 별로 영향을 받지 않고 있으며 원자로 누설${\gamma}$선에 의란 전조사선양률의 공기중에서의 감쇠는 폭 넓은 energy분포에도 불구하고 지수함수적 감쇠를 하고 있음이 판명되있다. 이 전조사선양률은 원자로의 열출력에 대체로 비례하고 있으나 TRIGA Mark III과 같은 가동형노심의 경우는 측정된 spectrum이 매우 다양한바, 그로부터 산출된 전조사선양률의 크기에는 관계없이, spectrum 분해방법을 적용하여 노심에서 발생된 누설 ${\gamma}$선과 원자로가동중 발생되는 여지 ${\gamma}$선의 기여를 판별 해석하는데 성공하였다.

  • PDF

KayPENTAX Phonatory Aerodynamic System Model 6600의 수행방법에 따른 공기역학 변수 비교 (Comparison of Aerodynamic Variables according to the Execution Methods of KayPENTAX Phonatory Aerodynamic System Model 6600)

  • 고혜주;최홍식;임성은;최예린
    • 말소리와 음성과학
    • /
    • 제7권4호
    • /
    • pp.93-99
    • /
    • 2015
  • In case of PAS test, the air is sometimes leaked although the mask is tightly attached to the face, which is not reliable on the measured values. Therefore, this study aimed to assist the clinical practice suggesting the test method of PAS without air leakage. In the healthy subjects with 12 males and 12 females over 19 years old, three types of tests were performed on the voicing efficiency among the protocol of PAS Model 6600. They are; first, to attach the mask tightly to the face holding the handle of PAS with the subject's two hands (Method 1); second, to attach the mask tightly to the face holding the handle of PAS with the subject's one hand and pushing the body of PAS strongly with the other hand (Method 2); and third, to attach the mask tightly to the face pushing the upper part of the mask by the tester when the subject attached the mask to his or her face holding the handle of PAS with two hands (Method 3). Upon the study analyses, the mean negative pressure, the mean phonogram, subglottic air pressure, and voicing efficiency were shown to be statistically significantly different during PAS test in males depending on the methods. (p<.05) In case of females, only the target airflow rate showed significant difference depending on the methods during PAS test. (p<.001) In conclusion, Method 2 enhanced the noise level and strength while Method 1 was likely to leak the air more compared to the other two methods in males. In case of females, Method 1 showed significant leakage of the air flow. Not to allow the air flow leakage without affecting the outcome of PAS test, it will be the most useful for the tester to push the mask to the subject's face tightly (Method 3).

Fibrin Glue가 자연기흉의 재발에 미치는 영향 (The Effect of Fibrin Glue as a Prevention Against Spontaneous Pneumothorax)

  • 이석열
    • Journal of Chest Surgery
    • /
    • 제24권6호
    • /
    • pp.570-578
    • /
    • 1991
  • The spontaneous pneumothorax is the sudden collapse of the lung usually by air leakage from the ruptured sub-pleural bleb and has high recurrence rate. For prevention against recurrence, many drugs such as tetracycline, talcum powder, quinacrine, etc. have been used but the effects are not satisfactory. We reduced the recurrence rate successfully by the fibrin glue instillation through the chest tube. From the January 1989 to September 1990, we have managed 65 patients of spontaneous pneumothorax with closed thoracostomy and fibrin glue[fibrinogen 1gm/50ml with approtinin 3, 000kIU /ml, thrombin 5, 000IU /ml in 3% each 10ml] instillation through the chest tube. And we compared the results with those of 106 patients of spontaneous pneumothorax who were managed only by the closed thoracostomy from January 1985 to December 1988. Only the patients who visited our hospital with recurrence were considered as the recurred cases but the others were considered as not recurred. And the removal of chest tubes usually done 3 days after cessation of air leakage or 2 days after fibrin glue instillation Statistical analysis was done by X2-test. The results were as followings: 1. The recurrence rate of fibrin glue instillation group was lower than that of non-instillation group[1st attack: 15.1% versus 27.6% p<0, 05, the 2nd attack: 33.3% versus 73.7% p<0.01, the total 18.5% versus 35.8% p<0.01]. 2. The mean duration of chest tube drainage in the fibrin glue instillation group was shorter than non-instillation group[4.24$\pm$1.36 days versus 4.48$\pm$1.73 days p<0.05]. 3. The mean duration of hospitalization was shorter in the instillation group [8.12$\pm$3.5 days versus 10.8$\pm$3.8 days p<0.05] The complications were transient mild fever, chest pain, pleural effusion in 46 cases of 65 patients, but those didn`t make any problem. We concluded that the fibrin glue is effective in the reduction of recurrence rate, obliteration of air leakage and duration of hospitalization.

  • PDF

자연기흉의 흡인법 치료 효과 (Closed Thoracostomy of Spontaneous Pneumothorax : Clinical Comparison of Suction with No Suction)

  • 임승우;이동협;이정철
    • Journal of Chest Surgery
    • /
    • 제24권9호
    • /
    • pp.890-894
    • /
    • 1991
  • We have performed a prospective study to assess the efficacy of suction drainage in 45 patients with primary spontaneous pneumothorax and 15 patients with secondary spontaneous pneumothorax, treated by closed chest tube drainage with underwater seal during the period Jan. 1990 to Dec. 1990 at the Department of Thoracic and Cardiovascular Surgery, Yeungnam University Hospital. The patients were divided randomly into two groups, 28 cases receiving suction and the other 32 cases no suction. The success rate was 82.1% for the former and 87.5% for the latter with the overall success rate of 85.0% and there was no significant difference in success rate between the two groups According to the causes and the extent of pneumothorax, the difference between the success rates of the two groups was also not significant statistically. But according to the duration of air leakage, suction group under 2 days showed a high success rate[46.4%] and the same group with 3-4 days, a relatively low success rate[21.4%] compared with that of the former. We conclude that the suction treatment is somewhat valuable in shortening the tubing time in patients with small amounts of air leakage, but it doesn`t seem to increase the success rate in all patients.

  • PDF

베이즈 분류기를 이용한 수냉식 냉동기의 고장 진단 방법에 관한 실험적 연구 (An Experimental Study on Fault Detection and Diagnosis Method for a Water Chiller Using Bayes Classifier)

  • 이흥주;장영수;강병하
    • 설비공학논문집
    • /
    • 제20권7호
    • /
    • pp.508-516
    • /
    • 2008
  • Fault detection and diagnosis(FDD) system is beneficial in equipment management by providing the operator with tools which can help find out a failure of the system. An experimental study has been performed on fault detection and diagnosis method for a water chiller. Bayes classifier, which is one of classical pattern classifiers, is adopted in deciding whether fault occurred or not. Failure modes in this study include refrigerant leakage, decrease in mass flow rate of the chilled water and cooling water, and sensor error of the cooling water inlet temperature. It is possible to detect and diagnose faults in this study by adopting FDD algorithm using only four parameters(compressor outlet temperature, chilled water inlet temperature, cooling water outlet temperature and compressor power consumption). Refrigerant leakage failure is detected at 20% of refrigerant leakage. When mass flow rate of the chilled and cooling water decrease more than 8% or 12%, FDD algorithm can detect the faults. The deviation of temperature sensor over $0.6^{\circ}C$ can be detected as fault.

CFD를 이용한 Double Layer 슬롯 다이 헤드의 메니스커스 형성 연구 (Study of Meniscus Formation in a Double Layer Slot Die Head Using CFD)

  • 김기은;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제23권2호
    • /
    • pp.65-70
    • /
    • 2024
  • Using a computational fluid dynamics(CFD) simulation tool, we have provided a coating guideline for slot-die coating with a double layer slot die head. We have analyzed the fluid dynamics in terms of the coating speed, flow rate ratio, and viscosity ratio, which are critical for the stability of coating meniscus. We have identified the common coating defects such as break-up, air entrainment, and leakage by varying the coating speeds. The flow rate ratio is the critical parameter determining the wet film thickness of the top and bottom layers. It is shown that when the flow rate ratio exceeds or equals 1.8, air entrainment occurs due to insufficient hydraulic pressure in the bottom layer, even though the total flow rate remains constant. Furthermore, we have found that the flow of the bottom layer is significantly affected by the viscosity of top layer. The viscosity ratio of 4 or higher obstructs the flow of the bottom layer due to the increased hydraulic resistance, resulting in leakage. Finally, we have demonstrated that as the viscosity ratio increases from 0.1 to 10, the maximum coating speed rises from 0.4 mm/s to 1.6 mm/s, and the minimum wet film thickness decreases from 800 ㎛ to 200 ㎛.

  • PDF

배기열(排氣熱) 회수용(回收用) 축류(軸流) 회전형(回轉形) 현열교환기(顯熱交換器)의 최적설계(最適設計)에 관한 연구(硏究) (A Study on the Optimum Design of Axial Rotary Sensible Heat Exchanger for the Heat Recovery of Exhaust Gas)

  • 최영돈;박상동;우정선;태춘섭
    • 설비공학논문집
    • /
    • 제3권2호
    • /
    • pp.131-141
    • /
    • 1991
  • A method of optimum design of an axial rotary sensible heat exchanger for the heat recovery of exhaust gas from the air conditioning space was developed in consideration of economics of investment cost and profit according to the installation of heat exchangers. Leakage rate of exhaust gas was calculated and the correlation for the pressure drop due to leakage of exhaust gas was proposed. Heat transfer between the matrix and exhaust and intake gas was analysed to calculate the effectiveness of heat exchanger, which was used for the optimum design of rotary heat exchanger. The results show that optimum rotational speed increases as the length of rotor increases and there exists optimum NTU which maximizes the gain of total cost according to the installation of rotary heat exchanger.

  • PDF

세라믹 열교환기의 성능평가를 위한 실험적 연구 (An Experimental Study for Performance Evaluation of a Ceramic Heat Exchanger)

  • 최현수;신동훈
    • 한국연소학회지
    • /
    • 제16권1호
    • /
    • pp.46-51
    • /
    • 2011
  • Exhaust gas of an industrial furnace used at such as metallurgy or ceramic manufacturing usually contains thermal energy with high temperature which can be recycled by heat exchanger. However, when the temperature of the exhaust gas is high such as more than $1,000^{\circ}C$, ordinary metallic heat exchanger cannot fully recover the heat due to the limitation of operating temperature depending on the material property. In the present study, a compact ceramic heat exchanger of cross flow type is introduced and evaluated by heat exchange rate and operating temperature. The ceramic heat exchanger can endure the gas temperature more than $1,300^{\circ}C$, and its volumetric heat exchanging rate exceeds 1 MW/$m^3$. The experimental data is also compared with the previous numerical result which shows reasonable agreement. Meanwhile, the gas leakage rate is measured to be about 3~4%, and heat loss to environmental air is about 23~26% of the fuel energy.