• Title/Summary/Keyword: Air-flow

Search Result 7,003, Processing Time 0.031 seconds

A Prediction of the Air-lift Pump Performance by gas-liquid Flow Charac teristics of Riser (Riser의 기액유동 특성에 따른 Air-lift 펌프의 성능예측)

  • 박찬수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.252-258
    • /
    • 1999
  • As an effective means to convey crushed materials from seabed to on board ship and to raise hazardous or abrasive liquids air-lift pump provides a reliable mechanism due to its simple config-uration and easy-to-operate principle. The present study is focused on fundamental investigation of related performance by the analysis program based on the gas-liquid two-phase flow in circular pipes. The program covers pump operating in isothermal and vertical two-phase flow with Newto-nian liquids. it is summarized as important result that an optimum air mass flow rate exists for the maximum lifted liquid mass flow rate in terms of a given submergence rates and furthermore attachment of downcomer gives little effects on riser performance the conveyed liquid flow rate increases with larger submergence rate.

  • PDF

A Study on the Flow Characteristics of Gasoline Spray across the Suction Air Stream (흡입공기분류를 가로지르는 가솔린 분무의 유동 특성 연구)

  • 김원태;강신재;노병준
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.9
    • /
    • pp.63-74
    • /
    • 1999
  • When a fuel was injected with opening the intake valve of a port fuel injection engine, the spray atomization and flow characteristics in the intake port have a strong influence on the mixture formation of a combustion chamber. Thus , this study was to clarify the spray flow characteristics of the air-assist gasoline spray with fine dropkets across the suction air stream in model intake port. For the simulated opening intake valve in port, suction air stream was varied to 10m/s ∼30m/s. And fuel pressur ewas fixed to 300kPa, but air assist pressure was varied to 0∼25kPa for a vairable spray conditions. Spray flow trajectory was investigated by means of laser sheet visualization and the measurements of droplet sizes and velocities were made by PDPA system. Measured droplets within the spray flow field were subdivided into five size groups and then, the flow characteristics of droplet size groups were investigated to the spray across a suction air stream.

  • PDF

The Effect of Surrounding Gas Flow on the Heat Transfer of the Falling Film Flowing Down the Outside of a Vertical Tube (수직원관 외부 유하액막 열전달에 주변 기체유동이 미치는 영향)

  • 권경민;정시영;김병주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.996-1003
    • /
    • 2002
  • Heat transfer characteristics were investigated for the falling film flowing down the outside of an electrically heated vertical tube. Water was used for the falling film, and its Reynolds number was varied in the range of 70~500. Because water is heated and evaporated as it flows down, both sensible and latent heat transfer should be considered. The effect of the surrounding air movement was investigated by changing the direction of the air injection; without air injection, parallel-flow, and counter-flow. For all cases, sensible teat transfer rate was almost linearly increased with the increasing film flow rate. It was found that the film heat transfer coefficient was hardly influenced by the parallel air flow. However, the counter-flow of air reduced the heat transfer coefficient, which might be caused by the uneven distribution or flooding of the film. At high heat flux, a sudden change of the film heat transfer coefficient was detected as the film flow rate reached the transition value. It is supposed that this phenomenon was caused by the change in the film flow pattern.

Effect of Filler on the Flow of Counter Flow Type Cooling Tower (충진재(Filler)가 대향류형(Counter Flow Type) 냉각탑 유동에 미치는 영향에 대한 연구)

  • Shin, Jeong-Hoon;Lee, Jun-Kyoung;Jin, Cheol-Gyu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.4_2
    • /
    • pp.565-572
    • /
    • 2022
  • The white plume from the cooling tower can be generated by mixing between discharging hot and humid air and cold air outside. This causes various problems such as icing, traffic disturbances, and fire factors in the vicinity, moreover it can also damage the image of a company. Various methods can be used to prevent white plume, one of them is to install a heat exchanger at the outlet of the cooling tower so that the heat exchanger transfers as much heat as possible to lower the temperature. Therefore the air flow path in the cooling tower should be optimized. Installation of the filler can be used to make the air flow better, thus we investigate the effect of filler on the air flow using CFD method. The pressure and velocity profile in the cooling tower could be acquired by the calculations. The filler made the velocity of the air entering the heat exchanger uniform this was because high flow resistance of the filler suppresses the generation of eddy in the cooling tower. But the total air pressure drop increased about 2 times with filler because the pressure drop by the filler accounted for about 60% of the total pressure drop.

Airflow Characteristics of Natural Air Drying for Rough Rice (벼 상온통풍건조시설의 송풍특성)

  • Lee, Hyo-Jai;Kim, Hoon;Han, Jae-Woong
    • The Korean Journal of Community Living Science
    • /
    • v.24 no.3
    • /
    • pp.391-397
    • /
    • 2013
  • This study was conducted to define the characteristics of the fan according to the bed depth of rough rice for the silo used in South Korea. In this study, the characteristics like air flow resistance and air flow rate of the fan were investigated for an independent blowing system with 1 fan and the serial blowing system with 2 fans. In the experiment, the depth of rough rice was determined by 0, 1, 2, 3.2 and 4.5 m for an independent blowing system and the depth of rough rice was 4.5 m for the serial blowing system. The air flow resistances of the blowing fan and the suction fan in an independent blowing system were 55 mmAq and 88 mmAq respectively. In addition, the air flow resistance of the serial blowing system was 61% lower than the blowing fan and 28% lower than the suction fan of the independent blowing system. The air flow rates of the blowing fan and the suction fan in the serial blowing system were 516 $m^3/min$, 570 $m^3/min$, respectively. The former was 22% higher than the blowing fan while the latter was 29% higher than the suction fan in the independence blowing system. In other words, the serial blowing system was superior to the independent blowing system in blowing characteristics because the air flow rate was lower and air flow resistance was higher than the independent blowing system. However, the fan power consumption of the serial blowing system was more than 100% comparing with the independent blowing system.

Estimation of Air Flow Rate in Automotive Ventilated Seat (자동차 통풍 시트의 유량 평가)

  • Lee, Hyun-Hee;Kim, Tae-Kyung;Lee, Kwangju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.34-40
    • /
    • 2016
  • In ventilated seats for cars, air flow is generated by a fan and passed through a foam pad, foam filter, and seat cover. There is a significant loss of air flow in this process, and it is not easy to analyze the amount delivered to the driver. Another difficulty is the geometric complexity of the air flow passage inside the seats. In this paper, the air flow through a foam pad was analyzed. Proper modeling of the bumps in the ventilation mat was found to be important in the analysis. Air flow is lost when it passes through the porous pad foam, which was measured and used to correct the analysis results. The corrected analysis results were in a good agreement with the experimental results. The amount of air flow delivered to a driver was measured using an airflow cone. Only 35.7% of the air flow from the fan was delivered.

Numerical Simulation of Flow Field and Air Pollutatnts Concentration in Kwangyang Bay (광양만권의 유동장 및 대기오염농도예측)

  • 정용현
    • Journal of Environmental Science International
    • /
    • v.9 no.5
    • /
    • pp.397-402
    • /
    • 2000
  • Numerical simulation model using nesting method and considering topographic features was developed to predict atmospheric environments atmospheric flow temperature and diffusion of air pollutants in Kwangyang bay where having complex areas of point sources Korea. In addition developed simulation model was used tracing of spreading range of pollutants when a gas leaks suddenly from Yeo-cheon industrial complex. by comparing the measured and calculated data on atmospheric flow temperature and diffusion of air pollutants the results showed that this model can be well applied and complicated topography affected the diffusion of air pollutants.

  • PDF

A Study on the Dehumidification Control to Prevent Condensation for Radiant Floor Cooling (바닥복사냉방의 결로방지를 위한 제습제어에 관한 연구)

  • 김용이;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.137-143
    • /
    • 2003
  • In the forming of an integrated system of radiant floor cooling and dehumidifying, chilled coil can be used for cooling and dehumidification. Therefore, it is necessary to find the efficient control method which can eliminates latent load efficiently. This study has been conducted to find this method by dividing the dehumidification system into 3 types according to the control variables and analyzing characteristics of each system. To prevent the floor surface condensation, the amount of condensation can be manipulated by water temperatures, water flow rates in chilled coil, and air flow rates passing by it. So dehumidification system control can be divided into constant air flow control and variable air flow control. Regarding dehumidification control, variable air flow control, which eliminates latent load rather than sensible load, is preferable to constant flow control.

Study of Pressure and Flow in the Air-Cleaner of Commercial Vehicle (디젤엔진의 공기청정기내 압력 및 유동분포에 관한 연구)

  • 류명석;구영곤;김경훈;맹주성
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.3
    • /
    • pp.47-53
    • /
    • 1997
  • The importance of intake system can not be overstressed in the recent heavy duty commercial vehicle design. The basic requirements of intake system are to have less flow resistance and better air cleaning performance which have direct effects on the performance and service life of engine. In order to improve the performance of engine intake system, the flow phenomena in the intake system should be fully understood. With readily availble CFD code, the numerical analysis becomes the more reliable tools for flow optimization in recent design work. In this research, flow field in the intake system was analyzed by STAR-CD, the 3-D computational fluid dynamics code. Especially, the flow inside of air cleaner was thoroughly analyzed. Pressure distribution and velocity profile in the air cleaner and intake duct was obtained. Having the dust seperated from incoming air at the expense of less pressure drop is the ultimate goal for the research.

  • PDF

The influence of co-axial air flow on the breakup length of a smooth liquid jet (平滑流의 分裂길이에 미치는 同軸氣流의 영향)

  • 김덕줄;이충원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.6
    • /
    • pp.1390-1398
    • /
    • 1988
  • The purpose of this study was experimentally to investigate the disintegration process and disintegration mechanism when co-axial air flows vertically for the longest smooth liquid jet. These were affected by liquid velocity, air velocity, air-to-liquid diameter ratio, nozzle shape, and air-liquid contacting position. That is, this process of disintegration of the liquid jet was similar to that occurred when liquid pressure was increased. At Reynolds number of 10, 000 and below, the changes in the breakup length represent different tendency according to liquid flow rate. The influence of air flow on the disintegration of liquid jet was different according to air-to-liquid diameter ratio, air orifice diameter, nozzle shape and contacting position of liquid and air. In particular, when the tip of liquid nozzle was inside the air orifice, the effect of air flow was the larger than outside the air orifice. The effect of liquid mass flow rate on the change rate of the breakup length was also different.