• 제목/요약/키워드: Air-curtain nozzle

검색결과 9건 처리시간 0.033초

난방공간에서 에어커튼의 토출각도 변화에 따른 성능 변화 (Performance Variation of the Air Curtain for Various Discharge Angles in Feating Space)

  • 성순경
    • 설비공학논문집
    • /
    • 제22권2호
    • /
    • pp.57-63
    • /
    • 2010
  • Air curtains are widely used for gates of shopping mall, warehouse, cold stores and refrigerated display cabinets. The purpose of the air curtain is to reduce the infiltration of outdoor air and heat loss from the air conditioning space to ambient air. The discharge angle of air curtain is very important as the sealing efficiency is affected by it. This paper presents a performance of single jet air curtain in heating space when the discharge angle of nozzle changes. A numerical simulation is used to study the influence of various parameters on the efficiency of the downward-blowing air curtain device which is installed inside of the wall above the door. The performance of the air curtain is evaluated by sealing efficiency which provides the assessment of the energy savings. A condition of discharge angle that has the highest sealing efficiency is proposed.

터널 화재시 연기확산 차단을 위한 양방향 토출 에어커튼 시스템에 대한 연구 (The Study on the Bi-directional Ejection Air Curtain System for Blocking Smoke Diffusion in case of Tunnel Fire)

  • 양상호;최영석;김정엽;김남구;김경엽
    • 한국유체기계학회 논문집
    • /
    • 제17권5호
    • /
    • pp.43-53
    • /
    • 2014
  • This paper presents a the study on air curtain system of top and bottom bi-directional jet air discharge for blocking the spread of smoke in case of tunnel fire. The five kinds different air curtains of A, B, C, D, and E of models for various performance tested after manufactured. A results of the various performance test obtained the best efficiency from E model air curtain. And optimize the injection angle of the air curtain nozzle through the three-dimensional computational fluid dynamics (CFD) analysis and analyzed the effects of external pressure of tunnel. and also single factor design have been applied. At present, our attention is focused on the velocity distribution(flow width and flow position) of 1.5m on the ground in tunnel. Also, analyzed the influence of draft in the tunnel. Detailed effects of discharge angle of air curtain and velocity at nozzle exit are discussed.

균일한 제트 분출을 위한 에어커튼 노즐 설계 (Air Curtain Nozzle Design for Uniform Jet Expulsion)

  • 박원희;장희철
    • 한국화재소방학회논문지
    • /
    • 제30권4호
    • /
    • pp.39-45
    • /
    • 2016
  • 화재발생시 가장 큰 인명피해를 유발시키는 연기의 안전한 구역으로 유입을 차단하기 위해 방화문 등 출입구 상부에 설치되는 에어커튼 노즐의 최적 설계를 수행하였다. 연기의 유입을 차단을 목적으로 개구부 상부에 설치되는 에어커튼 노즐의 슬릿에서 유동이 편심되지 않고 외부로 균일하게 배출되어야 한다. 유입 풍량, 내부 슬릿 형상, 외부 슬릿 두께 등을 변수로 고려하여 다양한 조건별로 수치해석을 수행하여 최종 형상을 선정하였다. 최종 형상을 시제품으로 제작하여 수치해석 결과와 비교 검증한바 모든 슬릿의 평균 속도에 대한 시험과 수치해석 결과의 상대오차는 1% 미만으로 매우 일치하는 경향을 보였다.

아연도금 부스 환기시스템 개선에 관한 수치해석 (Numerical Analysis on the Improvement of Zinc Plating Booth Ventilation System)

  • 진도훈
    • 한국산업융합학회 논문집
    • /
    • 제24권1호
    • /
    • pp.45-51
    • /
    • 2021
  • The purpose of this study is to suggest the optimal shape for a local air ventilation system for fume removal, which is operated in a zinc galvanizing factory, and to propose the improvement plan for a ventilation system used in a zinc galvanizing factory through flow analysis. A part of the air sprayed by an air curtain goes out. It will be necessary to research the position of an air curtain, its spray angles, and its nozzle shape. In addition, additional research needs to be conducted on the shape of the fan installed before a hood in order to make it easy to induce fume. In a local air ventilation system, air is inhaled from the outside. The higher an inlet negative pressure is, the easier fume is removed. It was found that it was necessary to install an appropriate hole in the wall on the back of a push nozzle in order to reduce an inlet negative pressure.

재래시장의 화재확산 방지를 위한 수막설비 설치 지침 (The Water Curtain Installation Guideline for Fire Spread Prevention in Market)

  • 최정욱;조성우
    • 설비공학논문집
    • /
    • 제28권7호
    • /
    • pp.269-274
    • /
    • 2016
  • This paper aims to suggest the water curtain installation guideline for prevention of fire spread. The water curtain systems play a role in preventing fire spread which is caused by fire flames and radiation heat release from a fire source. The radiation attenuation ratio is affected by the water droplet size, vertical distance from the nozzle and flow rate. This study suggests the water curtain installation guideline as follows : (1) Investigation of a reference store array (2) Calculation of the number of drencher heads (3) Review of the relationship between droplet size and attenuation factor depending on the height of the drencher head (4) Review of a drencher head array and spray overlapping. The reference traditional market in which a fire compartment is installed using a water curtain can be predicted to have a radiation attenuation ratio of 50%.

에어분사구 설치에 따른 폴리우레아 도막 방수·방식재의 비산 발생 저감에 관한 연구 (A study on the Reduction of Scattering of Polyurea Coating for Waterproofing and Anti-Corrosion by Installing Air Jet Nozzle)

  • 김선도;박완구;박진상;조일규;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.236-237
    • /
    • 2017
  • This study discusses the development of waterproofing layer jet-spray nozzle that forms a three-dimensional air cell. This nozzle has an air flow generation mechanism in the air groove of the attachment cell part located at the end of the injection nozzle. Since the air grooves also function as an air curtain, the airborne particles generated when the waterproof material is sprayed is effectively blocked. In the past, spraying of the waterproof material through the high pressure was possible, but this technology allows stable injection due to the static agitation method, and various problems caused by particle generation has been (damages to neighboring areas, economic loss, etc.) minimized.

  • PDF

유리커튼월 수막시스템 분무헤드의 화재 실험 연구 (Fire Experiment for a Water Curtain Nozzle in a Double Glazed Curtain Wall System)

  • 김성원;남지우;조성욱;유홍선;남준석;김동준
    • 한국화재소방학회논문지
    • /
    • 제30권3호
    • /
    • pp.31-40
    • /
    • 2016
  • 최근 초고층 건물 외벽에는 유리 커튼월 시스템이 많이 적용되고 있으며, 이러한 초고층 건물은 화재 발생 시 연돌효과 및 외부 기류에 따라 수직으로 화재가 급격하게 확산되는 특성을 가지고 있다. 기존에 사용되고 있는 스프링클러헤드는 상층부로의 화재 확산을 효과적으로 방지 할 수 없기 때문에 화재시 막대한 재산 및 인명피해를 초래한다. 따라서 본 연구에서는 보다 넓은 유리커튼월 면적을 방호할 수 있는 수막을 형성하고 층간 화재 확산을 방지 할 수 있는 수막 헤드를 개발하였다. 수막 헤드의 성능을 검증하기 위하여 살수 실험 장치를 구성하고 이를 활용하여 기존 스프링클러 헤드와 살수 패턴을 비교, 분석하였다. 상층부로의 화재 전파 차단 성능을 검토하기 위하여 2층 유리커튼월로 구성되어 있는 실험 장치를 활용하여 화재 실험을 수행하였다. 이를 통해 본 연구에서 제시한 수막 헤드가 기존 스프링클러헤드 보다 효과적으로 화염을 차단하는 것을 확인하였고 수치해석을 통해 최초 크랙 위치 및 파단 임계 온도를 분석하였다.

터널 화재시 물분무노즐에 의해 형성되는 제연수막의 연기층 확산방지성능에 관한 실험적 연구 (Experimental Research on Effects of Water Sprayed Curtain On Anti-diffusion of Fire Gases in Case of Tunnel Fire)

  • 박형주;최영상;지남용
    • 한국건축시공학회지
    • /
    • 제4권1호
    • /
    • pp.97-103
    • /
    • 2004
  • In case of a fire in road or railway tunnel it is always necessary to keep the escape condition as good as possible. Most of the victims of major fires in tunnels are because they couldn't leave the tunnel in time and were trapped by smoke, or rescue teams couldn't reach the place of the accident due to low visibility and high temperature. In spring 2003 a comprehensive field experiment was undertaken in a large scaled tunnel in Youngin City to test the effectiveness of a new water spray curtain system, designed to the air qualify inside of a tunnel in case of fire during passenger's escape to safe routes, In order to control the smoke propagation, fixed water sprayed nozzles were used to make water curtain system, which can be installed or hanging water piping line below ceiling. The experiment was accompanied by an extensive measurement campaign in order to measure temperature dropping effect and flow conditions as well as CO concentration for various water sprayed curtains produced by sprinkler heads or water spray nozzle. Eventually comparison analysis were undertaken to investigate the performance of water curtains under fixed water pressure. Therefore most effective water curtain system was presented on the basis of water droplet size in long tunnel.

터보 팬 2류체 노즐로 구성한 포그 분무장치를 이용한 온실 내 공기의 냉각 효과 (Cooling Effect of Air in Greenhouse Using A Fog Sprayer Consisted of Two-fluid Nozzle with Turbo Fan)

  • 김태규;민영봉;김도완;김명규;문성동;정태상
    • 농업생명과학연구
    • /
    • 제46권3호
    • /
    • pp.119-127
    • /
    • 2012
  • 여름철 고온기 온실 내 효율적 증발냉방을 위하여 다량 포그 분무가 가능하고 설치비용이 저렴하도록 한 터보팬 2류체 노즐로 포그 분무장치를 구성하고 소형 유리온실에 2.2 m 높이로 설치하여 냉방시험을 실시하였다. 이 장치의 분무시험 결과 평균분무입경이 $29{\mu}m$이고 1대당 포그 분무량은 $160m{\ell}/min$로 비산반경 2 m이내에서 입자들이 모두 증발하는 것으로 나타났다. 이 장치를 평면적 $228m^2$인 단동 유리온실에 2대를 설치하여 냉방실험한 결과, 외기의 온도 $30.2^{\circ}C$, 상대습도 81.2%인 때 온실 내 공기의 온도 $28.8^{\circ}C$, 상대습도 87.5%의 낮은 냉각효과를 나타내었다. 문헌 조사와 냉방실험 결과로부터 여름철 우리나라 남부지역의 외기온 $35^{\circ}C$를 기준으로 단동온실은 50% 차광에서 증발냉각에 의해 온실 내 공기온도를 외기온보다 $2{\sim}3^{\circ}C$ 낮추려면 환기회수 1회/분, 물분무량은 $10m{\ell}/min/m^2$인 것으로 추정되었다.