• Title/Summary/Keyword: Air-containing mass

검색결과 56건 처리시간 0.022초

공기-수면 음영을 보이는 종괴성 병변 (Air Shadow Containing Mass Lesion in the Chest)

  • 이경석;유관희;박상석;김원;이용철;이양근
    • Tuberculosis and Respiratory Diseases
    • /
    • 제41권1호
    • /
    • pp.63-67
    • /
    • 1994
  • A 70-year-old female patient was admitted due to the impression of lung abscess via local clinic. Chest P-A showed air shadow containing huge mass lesion in the right lower lung field, pericardio phrenic angle. But the patient complained of only mild upper respiratioy tract infection symptoms and the laboratory tests were within normal limits. Barium enema and chest C-T taken right after barium enema were performed in suggestion of the diaphragmatic hernia. Barium filled transverse colon and associated omentum were in the right anterior hemithorax surrounded by the hernial sac. The mass lesion shown in the chest P-A was compatible with the diaphragmatic hernia, Morgagni type. Operative reduction of the herniated bowel and simple closure of the diaphragm was performed.

  • PDF

Calculation of the air ratio in the case of firing gaseous fuels containing incombustibles

  • Cho, Kil-Won;Kunwoo Han;Park, Heung-Soo;Lee, Yong-Kuk;Lee, Kun-Hong
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1998년도 춘계 학술발표회 논문집
    • /
    • pp.43-48
    • /
    • 1998
  • A short-cut equation for the calculation of the air ratio in the case of firing gases containing incombustibles has been derived on the basis of mass balances. The new equation requires the oxygen concentration and the amount of carbon dioxide in the combustion gas, theoretical oxygen and air requirements, and the content of incombustibles other than carbon dioxide in the fuel for the air ratio calculation. By using the equation, a theoretically correct calculation of the air ratio has been enabled.

  • PDF

대기오염제어를 위한 생물살수여과법에서 물질전달계수 실험평가방법에 관한 연구 (Experimental Evaluation Method of Mass Transfer Coefficient on Biotrickling Filtration for Air Pollution Control)

  • 원양수;조완근
    • Korean Chemical Engineering Research
    • /
    • 제53권4호
    • /
    • pp.482-488
    • /
    • 2015
  • 생물학적 방법에 의한 대기오염물질 처리는 기존의 처리방법을 대체할 수 있는 방법으로 각광을 받고 있다. 생물학적 처리방법은 유기화합물 또는 악취가 포함된 저농도 고유량의 공기를 처리하는데 효과적이다. 생물살수여과법을 이용한 대기오염물질 제거에서 물질전달 연구는 공정 최적화를 위해 매우 중요한 부분이다. 본 연구에서는 3상의 물질전달이 이루어지는 생물살수여과법에서 기체/액체(살수액), 기체/고체(미생물), 액체/고체 물질전달 실험방법 개발과 물질전달 현상을 고찰하였다. 또한 본 연구에서는 각 상간에서 물질전달에 영향을 미치는 인자로 동적적체량, 기/액 유량비, 반응기내 미생물량, 살수액 순환량 등에 대해 고찰하였다.

지하철 객실 적용을 위한 황칠 추출물 소독제의 항균특성 및 안전성 평가 (Anti-bacterial properties and safety evaluation of disinfectant using Dendropanax morbifera (Hwangchil) extract for passenger cabin in the subway)

  • 부이칵호앙부;박재석;이영철
    • 한국입자에어로졸학회지
    • /
    • 제18권2호
    • /
    • pp.37-50
    • /
    • 2022
  • Due to the syndrome coronavirus 2 (SARS-CoV-2) pandemic, the subway passenger cabin should be continuously sterilized. However, a disinfectant such as chlorine is toxic and can lead to different issues to human health. In this paper, we introduced a novel disinfectant based on natural product (Dendropanax morbifera extract). Via ultra-high performance liquid chromatography - mass spectrometer (UHPLC-MS), different compounds from Dendropanax morbifera extract showed antivirus potentials. Antimicrobial experiments confirmed that the air-disinfectant containing Dendropanax morbifera can eliminate harmful microorganisms including Gram (-), Gram (+), and yeast within 5 mins. The as-prepared air-disinfectant also showed high antivirus activity against H1N1, HRV, and EV71. Deodorization test also indicates that the as-prepared air-disinfectant can lower the harmful gas such as ammonia and trimethylamine in the atmosphere. To evaluate the potential of air-disinfectant containing Dendropanax morbifera in practical applications, different safety tests including acute oral toxicity, acute skin irritation, and eye irritation were conducted. Results showed that the as-prepared disinfectant did not negatively affect tested animals during these safety investigations.

An FMN-Containing NADH-Quinone Reductase from Streptomyces sp. (An FMN-containing NADH-quinone reductase from streptomyces sp)

  • Youn, Hong-Duk;Lee, Jin-Won;Youn, Hwan;Lee, Jeong-Kug;Hah, Yung-Chil;Kang, Sa-Ouk
    • Journal of Microbiology
    • /
    • 제34권2호
    • /
    • pp.206-213
    • /
    • 1996
  • NADH-quinone reductase was purified 22-fold from the cytosolic fraction of Streptomyces sp. Imsnu-1 to apparent hemogenity, with an overall yield of 9%, by the purification procedure consisting of ammonium, sulfate precipitation and DEAE Sephacryl S-200 and DEAE 5 PW chromatographies. Thes molecular mass of the enzyme determined by gel filtration chromatography was found to be 110 kDa. SDS-PAGE revealed that the enzyme consists of two sugunits with a molecular mass of 54 kDa. The enzyme contained 1 mol of FMN per subunit as a cofactor. The $A_{272}$ A$_{457}$ ratio was 6.14 and the molar extinction coefficients were calculated to be 20, 800 and 25, 400M$^{-1}$ $cm^{-1}$ / AT 349 AND 457 nm, respectively. The N-terminal sequence of the enzyme contained the highly conserved fingerprint of ADP-binding domain. The enzyme used NADH as an electron donor and various quinones as electron acceptors. Cytochrome c was practically inactive. Air-stable flavin semiquinone was produced by the addition of NADH to the enzyme. Also, naphthosemiquinone was detected in the reaction mixture containing the enzyme.

  • PDF

Collisionally-Activated Dissociation of Peptides with a Disulfide Bond: Confirmation of the Mobile-Proton Model Based Explanation

  • Lee, Youn-Jin;Oh, Han-Bin
    • Mass Spectrometry Letters
    • /
    • 제1권1호
    • /
    • pp.5-8
    • /
    • 2010
  • In the present study, collisionally-activated dissociation (CAD) experiments were performed under low energy collision conditions in six peptides containing a disulfide bond. Fragments produced as a result of the cleavage of a disulfide bond were obtained after CAD in four peptides (bactenecin, TGF-$\alpha$, cortistantin, and linearly linked peptide, Scheme 1) with basic amino acid residues. In contrast, the CAD analysis of two peptides with no basic residue (oxytocin and tocinoic acid) rarely produced fragments indicative of cleavage of a disulfide bond. These results are consistent with the mobile proton model suggested by the McLuckey and O'air groups (ref. 22 and 23); nonmobile protons sequestered at basic amino acid residues appear to promote the cleavage of disulfide bonds.

Determination of Volatile Organic Compounds (VOCs) Using Tedlar Bag/Solid-phase Microextraction/Gas Chromatography/Mass Spectrometry (SPME/GC/MS) in Ambient and Workplace Air

  • Lee, Jae-Hwan;Hwang, Seung-Man;Lee, Dai-Woon;Heo, Gwi-Suk
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권3호
    • /
    • pp.488-496
    • /
    • 2002
  • SPME techniques have proven to be very useful tools in the analysis of wide VOCs in the air. In this study, we estimated VOCs in ambient and workplace air using a Tedlar ba /SPME/GC/MS system. The calibration curve was set to be linear over the range of 1-30 ppbv. The detection limits ranged from 10 pptv to 0.93 ppbv for all VOCs. Reproducibility of TO-14 target gas mixtures by SPME/GC/MS averaged at 8.8 R.S.D (%). Air toxic VOCs (hazardous air pollutants, HAPs) containing a total of forty halohydrocarbons, aromatics, and haloaro-matic carbons could be analyzed with significant accuracy, detection limit and linearity at low ppbv level. Only reactive VOCs with low molecular weight, such as chloromethane, vinylchloride, ethylchloride and 1,2-dichloro-ethane, yielded relatively poor results using this technique. In ambient air samples, ten VOCs were identified and quantified after external calibration. VOC concentration in ambient and workplace air ranged from 0.04 to 1.85 ppbv. The overall process was successfully applied to identify and quantify VOCs in ambient/workplace air.

지하수에 용해된 질소, 아르곤 가스의 동시측정 (Simultaneous Determiniation of Ar/$N_2$Ratios in Groundwater)

  • Kim, Euisik;Roy F. Spalding
    • 대한지하수환경학회지
    • /
    • 제1권1호
    • /
    • pp.6-9
    • /
    • 1994
  • 지하수의 Ar/$N_2$가스의 비율은 탈질화(denitrification)의 정도를 측정하는 하나의 방법으로 사용된다. (Barnes et al., 1975; Vogel et al., 1981; Mariotti et al., 1988) 그 비율 측정은 일반적으로 질량분석기 (Mass Spectrometer)를 사용한다. 본 실험에서 사용한 Mass Spectrometer는 일반적인 Static Mass Spectrometer가 아닌 Ar과 $N_2$을 시간적으로 동시에 측정하여 오차를 줄일 수 있는 VG Optima isotope ratio Mass Spectrometer를 사용하였다. 두 지역 지하수의 Ar/$N_2$가스의 비율을 측정한 결과 Site 1(Grand Island, NE)의 경우 대기가스가 포화된 증류수의 Ar/$N_2$가스 비율인 0.026보다 낮은 0.015-0.018로서 탈질이 일어났음을 알 수 있으며, Site 2(Shelton, NE)의 경우 0.023-0.02로서 탈질이 일어나지 않음을 알 수 있다. 본 실험의 목적은 지하수에 응해되어 있는 Ar/Nitrogen의 비율을 정확히 측정하는 방법을 개발하므로서 탈질의 정도를 정확히 측정하며 탈질의 전개 과정을 관찰하기 위한 것이다.

  • PDF

폐 내엽형 격절부:1례 보고 (Intralobar Puhnonary Sequestration - Report of one case -)

  • 김승규
    • Journal of Chest Surgery
    • /
    • 제25권5호
    • /
    • pp.541-543
    • /
    • 1992
  • We experienced a case of intralobar pulmonary sequestration preoperatively confirmed. The 10 years old male patient was admitted beacuse of recurrent episode of coughing and production of purulent sputum. the chest X-ray showed a dense mass containing a large cyst with air-fiuid level in right lower lung field. An aortogram was performed and revealed that the sequestrated portion of the RLL was supplied by an aberrant large artery arising directly from the lower thoracic aorta. After division and ligation of the aberrant artery in pulmonary ligament, the right lower lobectomy was performed and the patient`s postoperative course was uneventful.

  • PDF

발전소용 공랭식 응축기(ACC)의 작동조건 변화에 따른 성능특성에 대한 수치적 연구 (A Numerical Study on the Performance Characteristics of a Power Plant Air-Cooled Condenser (ACC) Affected by Changes in Operating Conditions)

  • 박경민;주기홍;박창용
    • 한국생산제조학회지
    • /
    • 제26권2호
    • /
    • pp.243-250
    • /
    • 2017
  • A numerical study was conducted to calculate the cooling capacity variation of a power plant ACC (air-cooled condenser) caused by changes in operating conditions. A numerical model was developed using the ${\varepsilon}-NTU$ and finite volume method, containing 100 elements for a single low fin tube. The model was validated through a comparison of cooling capacity between the simulated values and manufacturer's data. Even though simple assumptions and previously presented heat transfer correlations were applied to the model, the prediction error was 1.9%. The simulated variables of the operating conditions were air velocity, air temperature, and mass flux. The analysis on the variation of thermal resistance along the tube showed that the water side thermal resistance was higher than the air side thermal resistance at the downstream end of the tube, indicating that the ACC capacity could be increased by applying technology to enhance in-tube flow condensation heat transfer.