• Title/Summary/Keyword: Air-containing mass

Search Result 56, Processing Time 0.022 seconds

Air Shadow Containing Mass Lesion in the Chest (공기-수면 음영을 보이는 종괴성 병변)

  • Rhee, Kyoung-Suk;You, Kwan-Hee;Park, Sang-Suk;Kim, Won;Lee, Yong-Chul;Rhee, Yang-Keun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.1
    • /
    • pp.63-67
    • /
    • 1994
  • A 70-year-old female patient was admitted due to the impression of lung abscess via local clinic. Chest P-A showed air shadow containing huge mass lesion in the right lower lung field, pericardio phrenic angle. But the patient complained of only mild upper respiratioy tract infection symptoms and the laboratory tests were within normal limits. Barium enema and chest C-T taken right after barium enema were performed in suggestion of the diaphragmatic hernia. Barium filled transverse colon and associated omentum were in the right anterior hemithorax surrounded by the hernial sac. The mass lesion shown in the chest P-A was compatible with the diaphragmatic hernia, Morgagni type. Operative reduction of the herniated bowel and simple closure of the diaphragm was performed.

  • PDF

Calculation of the air ratio in the case of firing gaseous fuels containing incombustibles

  • Cho, Kil-Won;Kunwoo Han;Park, Heung-Soo;Lee, Yong-Kuk;Lee, Kun-Hong
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1998.05a
    • /
    • pp.43-48
    • /
    • 1998
  • A short-cut equation for the calculation of the air ratio in the case of firing gases containing incombustibles has been derived on the basis of mass balances. The new equation requires the oxygen concentration and the amount of carbon dioxide in the combustion gas, theoretical oxygen and air requirements, and the content of incombustibles other than carbon dioxide in the fuel for the air ratio calculation. By using the equation, a theoretically correct calculation of the air ratio has been enabled.

  • PDF

Experimental Evaluation Method of Mass Transfer Coefficient on Biotrickling Filtration for Air Pollution Control (대기오염제어를 위한 생물살수여과법에서 물질전달계수 실험평가방법에 관한 연구)

  • Won, Yang-Soo;Jo, Wan-Keun
    • Korean Chemical Engineering Research
    • /
    • v.53 no.4
    • /
    • pp.482-488
    • /
    • 2015
  • Biological treatment is promising alternative to conventional air pollution control method. Bioreactors for air pollution control have found most of their success in the treatment of dilute and high flow waste air streams containing volatile organic compounds and odor. The studies of mass transfer in biotrickling filters for air pollution control were of importance in order to control and optimize the purification process. The objectives of this study were to develop the experimental methodologies to evaluate the mass transfer coefficients of gas/liquid(trickling liquid), gas/solid(biomass) and liquid/solid in three phase biotrickling filtration. Also, this study characterized the influence factors on mass transfer such as dynamic holdup volume, gas/liquid flow rate ratio, biomass weight in reactor and recirculation rate of trickling medium for each phase of biotrickling filter.

Anti-bacterial properties and safety evaluation of disinfectant using Dendropanax morbifera (Hwangchil) extract for passenger cabin in the subway (지하철 객실 적용을 위한 황칠 추출물 소독제의 항균특성 및 안전성 평가)

  • Bui, Vu Khac Hoang;Park, Jae-Seok;Lee, Young-Chul
    • Particle and aerosol research
    • /
    • v.18 no.2
    • /
    • pp.37-50
    • /
    • 2022
  • Due to the syndrome coronavirus 2 (SARS-CoV-2) pandemic, the subway passenger cabin should be continuously sterilized. However, a disinfectant such as chlorine is toxic and can lead to different issues to human health. In this paper, we introduced a novel disinfectant based on natural product (Dendropanax morbifera extract). Via ultra-high performance liquid chromatography - mass spectrometer (UHPLC-MS), different compounds from Dendropanax morbifera extract showed antivirus potentials. Antimicrobial experiments confirmed that the air-disinfectant containing Dendropanax morbifera can eliminate harmful microorganisms including Gram (-), Gram (+), and yeast within 5 mins. The as-prepared air-disinfectant also showed high antivirus activity against H1N1, HRV, and EV71. Deodorization test also indicates that the as-prepared air-disinfectant can lower the harmful gas such as ammonia and trimethylamine in the atmosphere. To evaluate the potential of air-disinfectant containing Dendropanax morbifera in practical applications, different safety tests including acute oral toxicity, acute skin irritation, and eye irritation were conducted. Results showed that the as-prepared disinfectant did not negatively affect tested animals during these safety investigations.

An FMN-containing NADH-quinone reductase from streptomyces sp (An FMN-Containing NADH-Quinone Reductase from Streptomyces sp.)

  • Youn, Hong-Duk;Lee, Jin-Won;Youn, Hwan;Lee, Jeong-Kug;Hah, Yung-Chil;Kang, Sa-Ouk
    • Journal of Microbiology
    • /
    • v.34 no.2
    • /
    • pp.206-213
    • /
    • 1996
  • NADH-quinone reductase was purified 22-fold from the cytosolic fraction of Streptomyces sp. Imsnu-1 to apparent hemogenity, with an overall yield of 9%, by the purification procedure consisting of ammonium, sulfate precipitation and DEAE Sephacryl S-200 and DEAE 5 PW chromatographies. Thes molecular mass of the enzyme determined by gel filtration chromatography was found to be 110 kDa. SDS-PAGE revealed that the enzyme consists of two sugunits with a molecular mass of 54 kDa. The enzyme contained 1 mol of FMN per subunit as a cofactor. The $A_{272}$ A$_{457}$ ratio was 6.14 and the molar extinction coefficients were calculated to be 20, 800 and 25, 400M$^{-1}$ $cm^{-1}$ / AT 349 AND 457 nm, respectively. The N-terminal sequence of the enzyme contained the highly conserved fingerprint of ADP-binding domain. The enzyme used NADH as an electron donor and various quinones as electron acceptors. Cytochrome c was practically inactive. Air-stable flavin semiquinone was produced by the addition of NADH to the enzyme. Also, naphthosemiquinone was detected in the reaction mixture containing the enzyme.

  • PDF

Collisionally-Activated Dissociation of Peptides with a Disulfide Bond: Confirmation of the Mobile-Proton Model Based Explanation

  • Lee, Youn-Jin;Oh, Han-Bin
    • Mass Spectrometry Letters
    • /
    • v.1 no.1
    • /
    • pp.5-8
    • /
    • 2010
  • In the present study, collisionally-activated dissociation (CAD) experiments were performed under low energy collision conditions in six peptides containing a disulfide bond. Fragments produced as a result of the cleavage of a disulfide bond were obtained after CAD in four peptides (bactenecin, TGF-$\alpha$, cortistantin, and linearly linked peptide, Scheme 1) with basic amino acid residues. In contrast, the CAD analysis of two peptides with no basic residue (oxytocin and tocinoic acid) rarely produced fragments indicative of cleavage of a disulfide bond. These results are consistent with the mobile proton model suggested by the McLuckey and O'air groups (ref. 22 and 23); nonmobile protons sequestered at basic amino acid residues appear to promote the cleavage of disulfide bonds.

Determination of Volatile Organic Compounds (VOCs) Using Tedlar Bag/Solid-phase Microextraction/Gas Chromatography/Mass Spectrometry (SPME/GC/MS) in Ambient and Workplace Air

  • Lee, Jae-Hwan;Hwang, Seung-Man;Lee, Dai-Woon;Heo, Gwi-Suk
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.3
    • /
    • pp.488-496
    • /
    • 2002
  • SPME techniques have proven to be very useful tools in the analysis of wide VOCs in the air. In this study, we estimated VOCs in ambient and workplace air using a Tedlar ba /SPME/GC/MS system. The calibration curve was set to be linear over the range of 1-30 ppbv. The detection limits ranged from 10 pptv to 0.93 ppbv for all VOCs. Reproducibility of TO-14 target gas mixtures by SPME/GC/MS averaged at 8.8 R.S.D (%). Air toxic VOCs (hazardous air pollutants, HAPs) containing a total of forty halohydrocarbons, aromatics, and haloaro-matic carbons could be analyzed with significant accuracy, detection limit and linearity at low ppbv level. Only reactive VOCs with low molecular weight, such as chloromethane, vinylchloride, ethylchloride and 1,2-dichloro-ethane, yielded relatively poor results using this technique. In ambient air samples, ten VOCs were identified and quantified after external calibration. VOC concentration in ambient and workplace air ranged from 0.04 to 1.85 ppbv. The overall process was successfully applied to identify and quantify VOCs in ambient/workplace air.

Simultaneous Determiniation of Ar/$N_2$Ratios in Groundwater (지하수에 용해된 질소, 아르곤 가스의 동시측정)

  • Kim, Euisik;Roy F. Spalding
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.1 no.1
    • /
    • pp.6-9
    • /
    • 1994
  • Previously reported Ar/N$_2$ratios in groundwater have been measured by single ion monitoring (Barnes et al., 1975; Vogel et al., 1981; Mariotti et al., 1988). The detector geometry and flared flight tube in VG Optima isotopic ratio mass spectrometer appeared to be fortuitously aligned for the simultaneous measurement of Ar/N$_2$ratios. Method development included mechanical adjustments to optimize the mass spectrometer for Ar/N$_2$ratio measurements followed by development of a preparation system for the extraction of air-saturated water samples. Samples containing known Ar/N$_2$ratios were used to assess accuracy and precision, and to test the applicability of methods for measurements of aqueous Ar/N$_2$ratios. The results indicated that the prepared air-saturated water samples were almost identical to the predicted Ar/N$_2$ratios (p <0.001). Groundwater samples were collected from on-going research sites, Shelton and Grand Island, Nebraska. Samples from the Grand Island sludge injection site form a lower boundary for worldwide reported Ar/N$_2$ratios. These lower Ar/N$_2$ratios can be explained by the production of nitrogen gas from this site, where denitrification was reported previously.

  • PDF

Intralobar Puhnonary Sequestration - Report of one case - (폐 내엽형 격절부:1례 보고)

  • 김승규
    • Journal of Chest Surgery
    • /
    • v.25 no.5
    • /
    • pp.541-543
    • /
    • 1992
  • We experienced a case of intralobar pulmonary sequestration preoperatively confirmed. The 10 years old male patient was admitted beacuse of recurrent episode of coughing and production of purulent sputum. the chest X-ray showed a dense mass containing a large cyst with air-fiuid level in right lower lung field. An aortogram was performed and revealed that the sequestrated portion of the RLL was supplied by an aberrant large artery arising directly from the lower thoracic aorta. After division and ligation of the aberrant artery in pulmonary ligament, the right lower lobectomy was performed and the patient`s postoperative course was uneventful.

  • PDF

A Numerical Study on the Performance Characteristics of a Power Plant Air-Cooled Condenser (ACC) Affected by Changes in Operating Conditions (발전소용 공랭식 응축기(ACC)의 작동조건 변화에 따른 성능특성에 대한 수치적 연구)

  • Park, Kyung-Min;Ju, Kihong;Park, Chang Yong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.2
    • /
    • pp.243-250
    • /
    • 2017
  • A numerical study was conducted to calculate the cooling capacity variation of a power plant ACC (air-cooled condenser) caused by changes in operating conditions. A numerical model was developed using the ${\varepsilon}-NTU$ and finite volume method, containing 100 elements for a single low fin tube. The model was validated through a comparison of cooling capacity between the simulated values and manufacturer's data. Even though simple assumptions and previously presented heat transfer correlations were applied to the model, the prediction error was 1.9%. The simulated variables of the operating conditions were air velocity, air temperature, and mass flux. The analysis on the variation of thermal resistance along the tube showed that the water side thermal resistance was higher than the air side thermal resistance at the downstream end of the tube, indicating that the ACC capacity could be increased by applying technology to enhance in-tube flow condensation heat transfer.