Numerical Analysis for Optimal Design of Heat Exchanger in Air Compressor for Railroad Vehicle (철도차량용 공기압축기의 열교환기 최적 설계를 위한 해석 연구)

  • Kim, Moo Sun;Chung, Jong Deok;Jang, Seongil;Ahn, Joon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.11
    • /
    • pp.570-579
    • /
    • 2017
  • In this study, we examined the multi-stage piston-type air compressors typically used in a railroad vehicle, and the heat transfer efficiency was analyzed according to the design conditions of the heat exchanger (a compressor component module for cooling the compressed high temperature air). For the fin-tube heat exchanger used in the most air compressors, numerical analysis was performed to analyze heat transfer by defining the various rectangle tube sizes and the number of fin-per-unit area as design variables under the same flow rate of compressed air. Also, this analysis compared the temperature of the compressed air. Regarding environmental conditions for analysis, the flow rate of the external cooling air was measured and the mean value of the values was applied. And a "turbulence model" was considered in both the external flow of the cooling air and the internal flow inside the tube. From the results of analysis, it was found that the change of the aspect ratio value of the tube greatly influences the heat transfer efficiency of the compressed air, and influences if the fin density is relatively small. As a result, the optimum design specifications of the heat exchanger for air compressors were confirmed based on the analysis of the heat transfer efficiency, according to the design conditions of fin and tube by the operating temperature range of the compressed air.

System Design and Performance Prediction of a Stirling Engine for Residential Heat Pumps (가정용 열펌프 구동용 스터링 엔진의 시스템 설계 및 성능 예측)

  • Kim, U.T.;Kang, B.H.;Lee, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.4
    • /
    • pp.231-240
    • /
    • 1991
  • A design method has been developed for a Stirling engine with a tubular heater and cooler and a screen type regenerator. This paper provides a design procedure to determine the thermodynamic states and the geometric configurations of the Stirling engine for residential heat pumps. The major design is concerned with the working spaces, i.e. compression and expansion spaces and the heat exchangers such as the heater, the cooler and the regenerator. The Schmidt analysis has been employed to obtain the mass flow rates and heat transfer requirements of the system. The performance analysis of a model Stirling engine was performed by Martini-Weiss program to prove the validity of this design method. The results obtained indicate that this design method is valid for the Stirling engine conceptual design and performance analysis.

  • PDF

Performance Analysis of Summertime Heat Transfer Characteristics of the Double Skin Window for Plant Factory (식물공장 이중창호의 하절기 열전달 성능 분석)

  • So, Jae-Hyun;Kim, Woo-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.351-357
    • /
    • 2012
  • To reduce the summertime cooling load of a plant factory, a concept design was performed for the double skin window which utilizes the low temperature air from a ground coupled heat exchanger. The design parameters were selected as the number of cavity air inlet, the cavity thickness, the location of cavity air inlet, and the configuration of cavity air outlet. A parametric study was conducted in a systematic way to evaluate the heat transfer characteristics of the double skin window. As the number of cavity air inlet and the cavity thickness increase, the heat flux from outside air to indoor air was decreased. The effect of the location of cavity air inlet was not significant and the larger cavity air outlet area gave us relatively better heat blocking performance from outside hot air. This study demonstrated that it is possible to develop an improved double skin window by utilizing a ground coupled heat exchanger.

Analysis of leakage factors affecting ECV performance in variable compressor

  • Mahmud, Md. Iqbal;Cho, Haeng Muk
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.183-188
    • /
    • 2014
  • Solenoid operated electromagnetic control valve (ECV) using in an external variable displacement swash plate type compressor is widely used for air conditioning control system because of its low energy consumption and high efficient characteristics. ECV controls the entire vehicle air conditioning system by means of a pulse width modulation (PWM) system that supplied from an external controller. Different pressure ports located within ECV has important functions to control the air/refrigerant flow through its internal passages. The flow paths are preciously maintained with acceptable ranges of leakage (gap) between the parts inside it which is followed by effective design and critical dimensioning of its internal features. Therefore, it saves energy losses from the solenoid operation as well as ensures the balance of forces within it. The research paper highlights analysis of the leakages (at different pressure ports) and dimensioning tolerance factors that affects the ECV performance.

Drawing of Twenty Kinds of State and Process on Psychrometric Chart (습공기선도 상에 20 종류의 상태 및 과정 값의 작도)

  • Kim, Deok-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1201-1206
    • /
    • 2008
  • Psychrometric chart displays graphically the thermophysical properties of moist air, so it is very conveniently used in air-conditioning and refrigeration. On general psychrometric chart, there are dry bulb temperature, web bulb temperature, absolute humidity ratio, relative humidity, specific enthalpy, specific volume, sensible heat factor, and enthalpy-humidity difference ratio. However, various state and process values besides aboves can be plotted on psychrometric chart. In this study, we developed the software drawing twenty kinds of lines, that is vapor pressure, mole fraction ratio of vapor, dew point temperature, degree of saturation, density, specific entropy, specific exergy, contact or bypass factor, uncomfort index, discomposition index, predicted mean vote index, predicted percent dissatisfied, and so on. We wish to this software is a help to design, analysis and education.

  • PDF

Performance Evaluation of a Fin-Tube Heat Exchanger Using One-Dimensionalized Refrigerant Circuit (냉매유로를 1차원 배열화한 휜-관 열교환기 성능해석)

  • Kim, Doo-Hwan;Ye, Huee-Youl;Lee, Kwan-Soo;Cha, Woo-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.833-843
    • /
    • 2008
  • A new method is presented for developing a simulation program which can analyze the heat transfer characteristics of fin-tube heat exchanger. This method is able to describe several types of refrigerant circuit arrangement. The delivery path of air and refrigerant properties is simplified by transforming three-dimensional array into one-dimensional array. By comparing simulated results with experiment results, the deviation was 8.2%. Several fin-tube heat exchangers of different design factors and operating conditions were simulated using this program. It was shown that this program could be used for designing practical fin-tube heat exchangers.

Study on the Peltier Module to Insure the Structural Stability (Peltier module의 구조적 안정성 확보에 관한 연구)

  • Jun, Jong-Hoon;Kim, Jae-Jung;Kim, In-Kwan;Kim, Young-Soon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1144-1149
    • /
    • 2006
  • Electric power is generated by Seeback Effect if there is thermal difference in pettier module. Peltier module is composed by alumina, Bi-Te semiconductor and insulation (or air). If load is increased in pettier module, the alumina of module will be destroyed. One of the preventing method of module destruction is using damper between module and heat source. But the electric Power is dropped because of decrease of thermal difference, if thermal conductivity of damper was tourer than other thermoelectric materials. We design, Polymer Pad for enhancing thermoelectric porter. As the result of these experiment, Polymer Pad is more superior than the Rubber in the stability and thermal conduction.

  • PDF

Optimum Design of Axial-Flow Fans Including Noise Parameters (소음파라메터를 고려한 축류송풍기의 최적설계)

  • Son, B.J.;Lee, S.H.;Yoon, S.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.1
    • /
    • pp.1-12
    • /
    • 1995
  • In order to seek various relationships among many design parameters employed in the design of the axial-flow fans the program which generates acoustic spectrum has been developed and its validity verified. Outputs of the program, with other outputs from a formerly developed performance prediction program, have been used to form a multi-objective function, for which an optimal design process was carried out. The present analysis shows that overall noise level and efficiency has contrasting trends, and the chord length turns out to be the most critical design variable. In the chosen design case of requirements $Q=2000m^2/min$, ${\Delta}P_s=67mmAq$, D=1.4m, the chord length of 0.2059m minimizes the overall noise level, while chord length of 0.1254m maximizes the efficiency. The resulting chord length in the balanced optimization is 0.1809m.

  • PDF

Optimal Design Variables of a Parallel-Flow Heat Exchanger by Using a Desirability Function Approach (만족도 함수를 이용한 평행류 열교환기 설계인자 최적화)

  • Oh Seok-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.6
    • /
    • pp.587-595
    • /
    • 2005
  • The heat and flow characteristics in a parallel-flow heat exchanger were examined numerically to obtain its optimal design variables. A desirability function approach was introduced to optimize its performance with respect to the design parameters over the design domain. By varying the importance of heat transfer and pressure drop which are out put variables, the optimal values of the design parameters are examined. As a result, the us-age of the desirability function is very effective for the optimization of the design variables in a heat exchanger since the changes of optimal values are physically appropriate by varying the importance of each output variable.

Parametric Study on the Performance of a Counterflow Type Cooling Tower

  • Shin, Jee-Young;Son, Young-Seok
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.1
    • /
    • pp.17-23
    • /
    • 2003
  • A design procedure for cooling towers was set up using the Merkel theory In the past, the design data could be different depending on the characteristic curve that the engineer adopted. Therefore, consistent and reasonable criteria are required, which are based on the exact information of the cooling tower performance. In this study, analysis program for both the design and off-design for a counterflow-type cooling tower was developed and verified by comparing with experimental data. The off-design performance with various operating conditions was analyzed, as well.