• 제목/요약/키워드: Air-conditioning design

검색결과 1,311건 처리시간 0.024초

실외기 shroud 형상 최적 설계 (Optimization of design parameters on the shroud of air conditioner outdoor unit)

  • 유기정;예휘열;이상봉;이관수;차우호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.453-458
    • /
    • 2009
  • This paper presents a numerical evaluation of the flow rate of air conditioner outdoor unit as function of shroud design parameters. To determine the optimal design parameters, we investigated the flow rate by changing bell mouth height, fan height, fan guide height, fan width. The evaluation of the relative priority of the design parameters was performed to choose three important parameters in order to use a response surface method. The flow rate of the optimum model, compared to that of the base model, was increased by about 6.25%.

  • PDF

Electrical and Structural Design of Air-conditioning Fan Motor for Noise Reduction

  • Han Hyung-Suk;Mo Jin-Yong;Kim Chang-Hyun;Lee Jae-Kwon;Jeong Weui-Bong
    • Journal of Mechanical Science and Technology
    • /
    • 제20권10호
    • /
    • pp.1653-1661
    • /
    • 2006
  • AC induction motors have been widely used for fan motor of the air conditioner indoor unit. Noise of these AC induction motors is usually caused by the coupling effects of structural and electrical systems. The rotating torque and the noise from AC induction motor were discussed in this paper,. First, the modification of motor was carried out in order to reduce the unbalance magneto motive force between main and sub winding. Second, structural modification based on normal mode analysis and modal testing was carried out so that the fan motor does not have the natural frequencies near the 2f-line frequency. Numerical modifications through these two processes were verified by experiments, which showed that the sound pressure level at 2f-line frequency of the modified system became about 25dB less than that of conventional one.

빙축열을 이용한 저온급기/급수 냉방 시스템 (Cold Air/Water Distribution System with Ice Storage)

  • 김경훈;이종원
    • 대한설비공학회지:설비저널
    • /
    • 제20권2호
    • /
    • pp.125-133
    • /
    • 1991
  • This paper presents some design guidelines for using cold air/water distribution to cool commercial and industrial buildings. Cold air /water distribution systems provide primary air/water for space conditioning at nominal temperature between $3^{\circ}C$ and $10^{\circ}C$ ($4{\sim}5^{\circ}C$ might be recommendable for better selection). By using lower temperature primary air/water equipment could be downsized, means lower first costs, and often reduce annual energy costs up to 50% less than that of the conventional ($13^{\circ}C$) system. This concept takes full advantages of the $2{\sim}4^{\circ}C$ chilled water (brine) available with ice storate systems.

  • PDF

차륜형 대공포의 냉방기 최적화 설계 (Optimized Design of Air Controlling System in Air Defense Gun Systems of Wheeled Vehicle)

  • 전기현;이부환;이동희
    • 대한기계학회논문집B
    • /
    • 제37권11호
    • /
    • pp.1047-1051
    • /
    • 2013
  • 최신의 전투장갑차들은 통합형 공조장치를 선호하는 경향이 있음에도 불구하고 분리형 공조장치에 대한 필요성이 제기되고 있다. 본 연구에서는 특수목적용 장갑차량 및 군용규격이 요구되는 장갑차량의 냉방, 난방장치에 대한 연구로 상용 Fluent 를 이용한 유동해석을 통해 덕트 및 최적화 배치를 구현하였으며 실차을 통한 시험 수행으로 해석결과를 검증하고, 선정된 냉방 및 난방기의 유효성을 확인하였다. 기존 차량의 변경 모델이나 계열차량의 경우, 현재 선정된 모델의 부분 변경으로 가능하며, 차륜형 장갑차용으로 선정된 현재 모델의 유효성을 본 연구를 통해서 입증되었다.

핀-튜브 열교환기에서의 습증기 발생 메커니즘의 파악을 위한 실험적 연구 (An Experimental Study on Understanding of Production Mechanism of a Mist from Fin-Tube Heat Exchanger)

  • 박상균;윤석훈;김경근;김명환;오철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권3호
    • /
    • pp.595-604
    • /
    • 2001
  • As an improvement in the standard of living and economic growth, the demand for air conditioning equipment is increasing rapidly. Nowadays, air conditioning equipments are being used for industry, large building, house and car. There equipments were concentrated on improving heat efficiency of economic aspects while thy design heat exchanger for cooling and heating. These air conditioning equipments using heat exchanger cause a discomfort to user due to generating mist at the beginning of operating. Therefore, the user demand air of high class and quality. In this experimental study, to acquire elementary data for development of heat exchanger which be able to supply air of high quality, that is to say, possess a restraint effect of mist generation. We estimate an effect on cooling plate quality, supply air velocity, supply air temperature, cooled plate temperature and supply air relative humidity which have an influence on outlet air condition of heat exchanger.

  • PDF

빙상경기장의 공조시스템 분석에 관한 연구 (A Study on Analysis of Air Conditioning System in Ice Rinks)

  • 채문병;윤해동;이종신;변운섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.441-446
    • /
    • 2009
  • A modern industrial society is presently considering not only cultural life but also health promotion to enhance the quality of life. There are many ways to enjoy the wellbeing life. Especially, ice-skating has been focused on as leisure sports with many remarkable advantages. Even though ice-skating was recognized as winter sport, nowadays people enjoyed skating are increased more and more because of indoor ice link. So, construction of indoor ice link has been boomed up. However, The techniques of ice link freezing system are insufficient because the ice link freezing system on the local construction was designed by advanced country techniques. So, this study has been conducted to analyze the air conditioning and refrigeration system in existing local ice link to suggest the design method of ice link.

  • PDF

내벽에 유체가 있는 대류 사다리꼴 형상 Fin의 최적화 (Optimization of Convective Trapezoidal Profile Fin having Fluid inside the Wall)

  • 정병철;이성주;윤세창;강형석
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.95-102
    • /
    • 2006
  • This study analyzes and optimizes a design for a trapezoidal profile straight fin using one-dimensional analytical method. The heat transfer, fin length and fin height are optimized as a function of fin volume, fin shape factor and fin base length. In this optimization, convection characteristic number over fin surface and that of fluid inside fin wall are considered. One of the results shows that the maximum heat loss increases as fin volume increases and both fin shape factor and fin base length decrease.

덕트설비의 BIM 기반 자동검토를 위한 규칙개발에 관한 연구 (A Study on the Rule Development for BIM-based Automatic Checking in a Duct System)

  • 송종관;조근하;주기범
    • 설비공학논문집
    • /
    • 제25권11호
    • /
    • pp.631-639
    • /
    • 2013
  • This study derives quality checking items in Building Mechanical Systems Design Criteria, and suggests quality criteria to review BIM models in the duct system of an air conditioning system for rule-based automatic checking. First, components for the duct system of an air conditioning system were reviewed, and the quality checking items were drawn from Building Mechanical Systems Design Criteria, through assessment according to object, attribute and relationship composing the BIM model. Second, quality checking types were derived, by analyzing the quality checking items and Rule set of the Solibri Model Checker. Finally, methods of algorithm functioning for checking the BIM models for mechanical systems in computers were drawn, and Elements to comprise the quality checking criteria (rule) were suggested. This study means that that checking items are derived from domestic criteria, and a way for the development process of determining quality checking criteria (rules) is suggested.

증기-액 이젝터를 적용한 해양온도차발전 시스템의 성능 특성 (Performance Characteristics of OTEC(Ocean Thermal Energy Conversion) Power Cycle with Vapor-Liquid Ejector)

  • 윤정인;손창효;김현욱;하수정;이호생;김현주
    • 동력기계공학회지
    • /
    • 제18권5호
    • /
    • pp.88-93
    • /
    • 2014
  • In this paper, the performance analysis of condensation and evaporation capacity, turbine work and efficiency of the OTEC power system using vapor-liquid Ejector is presented to offer the basic design data for the operating parameters of the system. The working fluid used in this system is $CO_2$. The operating parameters considered in this study include the vapor quality at heat exchanger outlet, pressure ratio of ejector and inlet pressure of low turbine, mass flow ratio of separator at condenser outlet. The main results were summarized as follows. The efficiency of the OTEC power cycle has an enormous effect on the mass flow ratio of separator at condenser outlet. With a thorough grasp of these effects, it is possible to design the OTEC power cycle proposed in this study.

CFD를 이용한 지능형 객차 공기조화시스템 설계 (A Design of Intellectual Air-conditioning System using by CFD)

  • 배상호;박덕신;양우봉;박태영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.177-182
    • /
    • 2004
  • Railroad car is one of major public transportation because of an increase in population and heavy traffic problems. We design the concept with air filtration of HVAC system using CFD, select environment-friendly components and compose intellectual HVAC system. For this object, the research to connect HVAC system which control temperature, humidity, air flow with pollutant controlling system which can deal with particular dust, nasty smell. In case of train, fresh air should be provided continuously for pleasant environment of the cabin every season. The air will control outer dust, inner particular dust, $CO_2$ density by air conditioning, heating, humidity regulating, air filtering and ventilating. Ventilation system on passenger cars should be designed for the health and comfort of the passengers.

  • PDF