• Title/Summary/Keyword: Air-conditioning design

Search Result 1,313, Processing Time 0.027 seconds

Nanotronics-The Role of the Engineer in Nano-Technology. (나노트로닉스-나노테크놀로지에서 엔지니어의 역할)

  • Stout, K.J.;Johnson, A.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.10
    • /
    • pp.15-26
    • /
    • 1998
  • The role of the Engineer in the era of nano-technology is explored, a trend in manufacture which is expected to yield a $20-30 billion per annum business throughout the world by the year 2020. The engineers who will be working in this subject will be required to have broadly based experience, over a range of traditional disciplines, such as physics. electronics, software engineering, control and mechanical engineering. As well as having an appreciation of other disciplines such as air conditioning, vibration analysis and its minimisation, the selection of materials for maximum stability and minimal thermal distortion as well as an understanding of ultra precision design and nano tribology. In other words the engineer who is to be successful in this new and emerging field, will have to be broader based than engineers of the past, where it was traditional to break up the elements of a discipline to smaller subsets. But as nano-technology advances and the subject brings about the evolution of nanotronics to provide a successful solution to emerging problems, it will be essential for a breed of engineers to develop who can consider the subject in a holistic manner. This paper therefore considers the emergence of nano-technology, predicts the subsets of the development and places them in context of the new engineer which will be required in increasing numbers. The paper summarises the skills of the proposed nanotronics engineer and provides a basis for their training and development.

  • PDF

A Study on Ways to Improve the Smell of Pig Barn

  • Min-Jae JUNG;Su-Hye KIM;Young-Do KIM
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.6 no.2
    • /
    • pp.9-13
    • /
    • 2023
  • Purpose: In this study, we would like to make a technical proposal to solve the odor problem in pig houses. Through this, we would like to suggest an effective way to reduce the odor generated in the pig house as a solution to civil complaints. Research design, data and methodology: Conduct direct visits to pig farms where many civil complaints about bad odor occur, and identify the problems of each farm. Identify elements related to odor control, such as structure, facility, equipment, odor management method, and ventilation type. Through this, the technology to be applied to reduce odor and the solution to the odor problem are presented. Results: The results of major improvements are as follows: 1. Improvement of the structure of the barn or composting shed to an airtight type 2. Improvement of the pig manure treatment structure using the slope inside the barn 3. Establishment of ventilation and cooling systems 4. Automation of the mist spray system. Conclusions: As a result, as practical measures, sealing of facilities using winch curtains, construction of air conditioning systems using negative pressure ventilation, and management systems using AIoT systems were presented. It is judged that this study can be helpful in determining the grievances caused by civil complaints of tenant livestock farms and the direction of facility improvement in the future.

A Study on Reliability Improvement of Domestic Ground Source Heat Pump Units by Analyzing the Certification System (국내 지열원 히트펌프 유닛의 인증제도 분석을 통한 신뢰성 향상 방안 연구)

  • Chan Woo Yang;Hee Jeong Kang;Sewang Oh;Ubin Do;Kwang Ho Lee;Jong Woong Choi;Yong Cho;Jong Min Choi
    • New & Renewable Energy
    • /
    • v.19 no.4
    • /
    • pp.72-83
    • /
    • 2023
  • Only ground source heat pump units certified according to the regulations in Korea can be adopted in ground source heat pump systems. In this study, domestic and international standards and regulations for ground source heat pump units were investigated. Unlike ISO 13256-1~2, which is the international standard, KS B 8292~8294 for ground source heat pump unit only included rated test conditions. Therefore, it is necessary to supplement various test conditions to the KS B series, because its performance data, which is required to calculate the system's design capacity, is dependent on the change in entering water temperature. The difference between the coefficient of performance of the certified ground source heat pump units and the certified criteria changed significantly according to the operating mode, heat source, and load type, because the criteria increased by about 5% for all. Thus, it is highly suggested that the certification standards be revised while considering the product performance level and various conditions.

Development and Research of Thermal Management Equipment for Efficiency Enhancement of PEMFC Systems (PEMFC 시스템 효율 향상을 위한 열 관리 설비 개발 및 연구)

  • JAEHWAN KIM;JISEUNG LEE;INSEAK KANG;HYUNCHUL JU
    • Journal of Hydrogen and New Energy
    • /
    • v.35 no.2
    • /
    • pp.205-215
    • /
    • 2024
  • This study introduced a direct contact heat exchanger to enhance the efficiency of polymer electrolyte membrane fuel cells (PEMFCs) systems. According to previous research, 28% of the operating costs of fuel cell systems are attributed to heat exchanger devices, prompting the design of a direct contact heat exchanger to address this issue. Optimal configurations were determined through computational fluid dynamics analysis and experimental device fabrication, and the enhanced heat exchange performance of the heat exchanger was experimentally confirmed. Through this, the contribution of the direct contact heat exchanger to the heat management and efficiency enhancement of PEMFC systems was established.

Evaluation and Analysis of The Building Energy Saving Performance by Component of Wood Products Using EnergyPlus (EnergyPlus를 이용한 건물 부위별 목질제품 적용에 따른 건축물 에너지 절감 기여도 평가)

  • Seo, Jungki;Wi, Seunghwan;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.655-663
    • /
    • 2016
  • Increasing green house gas and it consequent climate change problems are discussed as a global issue. Accordingly, future local green house gas emission will increase up to 40% of the entire local green house gas emission and therefore, efforts to reduce the emission in construction industry is urgently required. Therefore, in this study, heating energy demand was analyzed by using the EnergyPlus simulation according to wood material finishes configuration. EnergyPlus has the entry for a variety of buildings and heating, ventilation, air conditioning (HAVC) system components, in particular buildings, air conditioning systems, and performs simultaneous integrated calculated through the feedback between the heat source unit, a verification program according to the ASHRAE Standard 140-2007 to be. The climate data for the simulation we used the data IWEC in Incheon and Gwangju provided by EnergyPlus. The analysis of simulation model was farm and fishing house standard design drawings: 2012, presented at the Korea Rural Community Corporation. The results of simulation of central region and southern region were effected by wood products of simulation model into the interior finish, exterior finish, windows, wooden structure. Also, it was confirmed that the reduced heating energy demand.

Development of a Compression/Absorption Hybrid Heat Pump System Using $NH_3/H_2O$ Mixture for High Temperature Generation ($NH_3/H_2O$를 이용한 압축-흡수식 고온제조 하이브리드 히트펌프 시스템 개발)

  • Kim, Min-Sung;Baik, Young-Jin;Shin, Kwang-Ho;Park, Seong-Ryong;Chang, Ki-Chang;Lee, Young-Soo;Ra, Ho-Sang
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1249-1254
    • /
    • 2008
  • Industrial low temperature waste heat exists sparse in surroundings but its amount is huge. However, large portion of waste heat is discarded due to its poor recovery quality and inferior application technologies. The heat pump system in this research is based on the hybrid combination of compression cycle and absorption cycle in order to recycle various kind of industrial waste heat effectively. The prime objective is to design a compression absorption hybrid heat pump system which can produce high temperature above the level of $90^{\circ}C$ and low temperature of $20^{\circ}C$ at the same time using waste heat water of $50^{\circ}C$. A mathematical simulation was carried out as a basis to design a prototype 3 RT class hybrid heat pump. From the simulation results, fundamental parameters to design the system were obtained.

  • PDF

Ventilation Performance Study on Hydrogen Leakage Characteristics of Container Packaged Water Electrolysis Production System (컨테이너 패키지형 그린수소 수전해 생산 시스템의 수소 누출 특성에 관한 환기 성능 연구)

  • SOOIN KWON;BYUNGSEOK JIN;CHEEWOO LEE;SEONGYONG EOM;GYUNGMIN CHOI
    • Journal of Hydrogen and New Energy
    • /
    • v.35 no.3
    • /
    • pp.324-335
    • /
    • 2024
  • The container package type sealed water electrolysis production system installs mechanical balance of plant and electrical balance of plant as an integrated unit to enable independent operation within the package module. The auxiliary equipment required to operate the water electrolysis system must be integrated to reduce the installation area and shorten the installation time. At this time, as leak risk factors are placed in a dense space, when a hydrogen gas leak accident occurs, it can have a mutual influence on other adjacent facilities, so it contains various risk factors. In this study, when a gas leak occurs in a container packaged water electrolysis system, possible sources of leakage in the system according to the KS C IEC 60079-10-1:2015 and KGS GC101 standards were identified, and the leak rate and leak characteristics were calculated. did. The hazardous area and its range were calculated according to ventilation and dilution characteristics. In order to optimize ventilation characteristics, design of experiment was used to analyze the influence to evaluate the adequacy of ventilation, and overseas ventilation standards were analyzed and compared. In addition, the optimal ventilation structure and characteristics of the container packaged water electrolysis system were presented according to the results of the experimental design method.

Changes in Plant Species on a Grass Roof over Time (초지지붕에서의 시간경과에 따른 식생변화)

  • Lee, Young-Moo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.34 no.6 s.119
    • /
    • pp.39-53
    • /
    • 2007
  • Unlike conventional roof landscaping, where various kinds of plants and structures are employed, a grass roof is a roof on which herbaceous plants are grown in planting medium and which is not accessed or maintained, mainly because it doesn't have sufficient load capacity to support a regular roof garden. They are mostly built on existing roofs, whether flat slab or gabled. Planting on roofs has numerous advantages, such as creating a biotope, purifying urban air, adding moisture to the atmosphere, storing rain water, preventing flash floods, reducing energy use for heating and air conditioning, enhancing the urban landscape and providing relaxation to the city dwellers, not to mention the alleviation of global warming by absorbing $CO_2$. In addition to the general merits of roof planting, the grass roof has its own unique qualities. Only herbaceous species are planted on the roof, resulting in light weight which allows roofs of existing buildings to be planted without structural reinforcement. The species chosen are mostly short, tough perennials that don't need to be maintained. These conditions provide an ideal situation where massive planting can be done in urban areas where roofs are often the only and definitely the largest space available to be planted. If roofs are planted on a massive scale they can play a significant role in alleviating global warming, heat island effects and energy shortages. Despite the advantages of grass roofs, there are some problems. The most significant problem is the invasion of neighboring plants. They may be brought in with the planting medium, by birds or by wind. These plants have little aesthetic value comparing to the chosen species and are usually taller. Eventually they dominate and prevail over the original species. The intended planting design disappears and the roof comes to look wild. Since the primary value of a grass roof is ecological, a change in attitude towards what constitutes beauty on the roofscape is necessary. Instead of keeping the roof neat through constant maintenance, people must learn that the wild grass with bird's nests on their roof is more beautiful as it is.

CFD Analysis on the Flow Characteristics of Ejector According to the Position Changes of Driving Nozzle for F.W.G (수치해석을 이용한 담수장치용 이젝터의 노즐위치 변화에 따른 이젝터 유동특성 연구)

  • Joo, Hong-Jin;Jung, Il-Young;Yun, Sang-Kook;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.23-28
    • /
    • 2011
  • In this study, the ejector design was modeled using Fluent 6.3 of FVM(Finite Volume Method) CFD(Computational Fluid Dynamics) techniques to resolve the flow dynamics in the ejector. A vacuum system with the ejector has been widely used because of its simple construction and easy maintenance. Ejector is the main part of the desalination system, of which designs determine the efficiency of system. The effects of the ejector was investigated geometry and the operating conditions in the hydraulic characteristics. The ejector consists mainly of a nozzle, suction chamber, mixing tube (throat), diffuser and draft tube. Liquid is supplied to the ejector nozzle, the fast liquid jet produced by the nozzle entrains and the non condensable gas was sucked into the mixing tube. The multiphase CFD modeling was carried out to determine the hydrodynamic characteristics of seawater-air ejector. Condition of the simulation was varied in entrance mass flow rate (1kg/s, 1.5kg/s, 2kg/s, 2.5kg/s, 3kg/s), and position of driving nozzle was located from the central axis of the suction at -10mm, 0mm, 10mm, 20mm, 30mm.. Asaresult, suction flow velocity has the highest value in central axis of the suction.

Behavior Analysis of a Self Excited Induction Generator with Various Loads for a Hybrid Electric Propulsion System (하이브리드 전기추진시스템 구축을 위한 SEIG의 출력 특성 분석)

  • Yang, Joo-Ho;Choi, Gyo-Ho;Lee, Jae-Min;Jeong, Seok-Kwon
    • Journal of Power System Engineering
    • /
    • v.22 no.1
    • /
    • pp.41-47
    • /
    • 2018
  • This paper analyzes the output characteristics of a self excited induction generator with isolated mode according to change of its speeds and loads for building a hybrid electric propulsion system in special purpose ships by using power take off. The induction generators are being considered as an alternative choice to the well-developed generators because of their lower unit cost, inherent ruggedness, operational and maintenance simplicity. However, the generator working by stand alone has a few problems that the reactive power is required to establish the air gap magnetic flux, and the induced voltage and magnetizing current fluctuate when the load is varied. In spite of its advantages, basic design data of the capacitor bank and behaviors of the output characteristics of the generator are not sufficient for the system. Based on the operating condition(speed range of main engine) of the target boat, a reduced experimental equipment system was constructed to analyze the output characteristics of the SEIG. And a suitable capacitor bank of a stand-alone generator and its output characteristics under various loads was investigated in detail through these experiments. According to the experimental result, it was confirmed that the capacitor bank should be $70{\mu}F{\sim}100{\mu}F$, and the proper SEIG induced voltage should be DC 80 V ~ 250 V in order to storage electrical energy into a battery.