• Title/Summary/Keyword: Air-conditioning and Heating system

Search Result 800, Processing Time 0.03 seconds

Simultaneous Heating and Cooling Multi-Air Conditioning System for Agricultural Products Management (농수산물 관리를 위한 냉난방 동시형 멀티 에어컨 시스템)

  • Shin, Jin-Seob;Hong, Ji-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.6
    • /
    • pp.65-70
    • /
    • 2020
  • In this paper, to establish a high-efficiency air-conditioning and heating system, we developed a simultaneous air-conditioning and heating system that can do both air-conditioning and heating at the same time. It was applied to hybrid plant plants to enable automation of complex farms. For this purpose, the heat exchanger, which functions as a condenser during heating, was required to function as an evaporator during cooling so that air conditioning and heating could be implemented simultaneously. For experiments, the simultaneous air conditioning system for heating and cooling was produced and applied to the plant factories in the farms so that plants could be grown, stored, and dried. As a result, a single system was able to control the temperature environment of agricultural products with an energy-saving system that simultaneously resolves heating and cooling. Therefore, efficient crop management was possible by implementing an air conditioning system that did not require installing air conditioners and boilers at the same time.

A Study on the Passive Principle and its Practical Application of Air-conditioning System (난방을 비롯한 공기조화의 자연조절 방식과 현대적 응용에 관한 고찰)

  • Park, Soon-Kwan
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.2
    • /
    • pp.105-112
    • /
    • 2004
  • The objective of this study is to observe today's situation and direction in relation with the natural air-conditioning and heating system to expand the architectural utilization of natural management for human comfort and energy conservation in architectural design. Also this study to provide the fundamental knowledge and. design-techniques on environment-friendly architecture in connection with 'natural idea in architecture'. In accordance with this intention, this thesis is composed of the following contents : 1) to understand the fundermental concepts about natural air-conditioning and heating system, 2) to review the traditional characteristics in Korean and Southeast Asian architecture related to natural air-conditioning and heating system, 3) to examine modern design-techniques in relation with natural air-conditioning and heating system in the selected area, 4) to attempt to synthesize the whole situation. Environment-friendly architecture using natural ideas and design-techniques in architecture is very important architectural aspect in a current architecture, also for the future. In spite of general considerations, it is expected that this study is use to understand the principle and practical application of natural air-conditioning and heating system in architectural design.

Evaluation of Indoor Thermal Environment According to Air-Barrier Air Conditioning System in Perimeter Zone (페리미터존의 에어배리어 공조방식에 따른 실내 열환경 평가)

  • Park Byung-Yoon;Ham Heung-Don;Sohn Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.370-376
    • /
    • 2005
  • For the purpose of investigating the effective removal of heating/cooling load from light-weighted building envelope, two air-conditioning systems, conventional parameter air-conditioning system and air-barrier system, are evaluated and compared by both experiment and simulation with six different cases during heating and cooling season. In addition, the characteristics of window-side building thermal load are assessed by varying supply air velocity in order to seek the optimal system operation condition. The results are as follows. 1) Air-barrier system is more effective to remove heating/cooling load at perimeter zone than conventional parameter air-conditioning system. Moreover, the better effectiveness appears during cooling season than during heating season. 2) The experiment during cooling season provides that indoor temperature of air-barrier system shows $1^{\circ}C$ less than that of the conventional system with similar outdoor air temperature profile, and indoor temperature distribution is more uniform throughout the experimented model space. It concludes that air-barrier system can achieve energy saving comparing to the conventional system. 3) The capturing efficiency of air-barrier system is 0.47 on heating season and 0.2 on cooling season with the same supply air volume. It results that the system performs effectively to remove building thermal load, moreover demonstrates high efficiency during cooling season. 4) The simulation results provide that capturing efficiency to evaluate the effective removal of building load from perimeter zone shows high value when supply air velocity is 1 m/s.

Performance Analysis of Water Direct Contact Air Conditioning System (물 직접접촉식 공기조화장치의 성능해석)

  • Yoo, S.Y.;Kwon, H.K.;Song, J.;Kim, K.Y.;Park, J.T.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.158-163
    • /
    • 2001
  • Performance of the water direct contact air conditioning system, in which heat and mass are transferred directly between air and water droplet, is simulated by semi-empirical method. This system improves transport efficiency compared to conventional indirect contact system and cooling, heating, dehumidification and humidification are attained with one unit. In this study, temperature and flowrate for air and water are measured in the various cooling and heating conditions, and correlations for $h_{c}A/c_{pm}$ are derived from these data. Cooling and heating characteristics of the water direct contact air conditioning system are investigated using correlations.

  • PDF

Performance Analysis of Water/Air Direct Contact Air Conditioning System (물-공기 직접접촉식 공기조화장치의 성능해석)

  • 유성연;권화길;김광영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.2
    • /
    • pp.175-183
    • /
    • 2004
  • Performance of the water/air direct contact air conditioning system, in which heat and mass are directly transferred between air and water droplet, is simulated using semi-empirical method. Direct contact system improves transport efficiency compared to conventional indirect contact system. In this study, correlations for h$_{c}$A / c$_{pm}$ which represent the capacity of direct contact system are derived as a function of air and water flowrate from the experimental data. Cooling and heating performance of the water/air direct contact air conditioning system are evaluated using these correlations.ons.

An Experimental Study on the Performance of a Heat Pump with a Refrigerant Heating Device (냉매가열식 열펌프시스템의 성능특성에 관한 실험적 연구)

  • Kim, Sang-Hyuk;Park, Youn-Cheol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.9
    • /
    • pp.707-713
    • /
    • 2006
  • To improve heating performance of the heat pump in winter season, refrigerant heating device was applied to conventional heat pump. The refrigerant heating device operates at the heating capacity does not enough to the heating load requirement of the conditioning space. When the discharge air temperature of the indoor heat exchanger goes down to below $40^{\circ}C$ which is criterion for comfort of the occupants in the conditioning space, the system also starts. The refrigerant heating system has new concept of auxiliary heating device for heat pump in winter. In this study, the system performance was analyzed through experiments and parametric study was conducted to improve the COP and control strategies.

An Experimental Study on the Characteristic of the Hot Water-Air Heating Generating System with a Solar Collector

  • Rokhman, Fatkhur;Hong, Boo-Pyo;You, Jin-Kwang;Yoon, Jung-In;Choi, Kwang-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.360-363
    • /
    • 2012
  • A solar air heating has low efficiency compared with the solar water heating because the heat capacity of the air is small. The heat received by solar collector plate is not fully transferred to the air and then a part of them became the losses to the environment through conduction and convection process. This research is focusing on a design of better combined multi-purposed system suggested by us and aims to secure the more efficient solar energy utilization by combining the hot water and air heating system. The result in this paper has shown that the proposed design has better thermal performance than that of the common design. Furthermore, it was found that the performance of the combined air - water heating system increases the efficiency from 30% to 35%-40%.

  • PDF

An Experimental Study on the Performance of Air/Water Direct Contact Air Conditioning System

  • Yoo, Seong-Yeon;Kwon, Hwa-Kil
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.1002-1009
    • /
    • 2004
  • Direct contact air conditioning systems, in which heat and mass are transferred directly between air and water droplets, have many advantages over conventional indirect contact systems. The purpose of this research is to investigate the cooling and heating performances of direct contact air conditioning system for various inlet parameters such as air velocity, air temperature, water flow rate and water temperature. The experimental apparatus comprises a wind tunnel, water spray system, scrubber, demister, heater, refrigerator, flow and temperature controller, and data acquisition system. The inlet and outlet conditions of air and water are measured when the air contacts directly with water droplets as a counter flow in the spray section of the wind tunnel, and the heat and mass transfer rates between air and water are calculated. The droplet size of the water sprays is also measured using a Malvern Particle Analyzer. In the cooling conditions, the outlet air temperature and humidity ratio decrease as the water flow rate increases and as the water temperature, air velocity and temperature decrease. On the contrary, the outlet air temperature and humidity ratio increase in the heating conditions as the water flow rate and temperature increase and as the air velocity decreases.

Operating characteristics of 3RT heat pumps

  • Moon, Chang-Uk;Choi, Kwang-Hwan;Yoon, Jung-In;Jeon, Min-Ju;Heo, Seong-Kwan;Sung, Yo-Han;Park, Sung-Hyeon;Lee, Jin-Kook;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.2
    • /
    • pp.140-145
    • /
    • 2017
  • Newly designed vapor-injection heat pumps have been proposed and analyzed in the present study. An economizer-type vapor-injection (V-I) system has been employed as the standard system because of its reliability and simple control method. The V-I system has a re-cooler and re-heater for cooling and heating, respectively. Solar panels have been installed in the V-I heat pump as well as in the re-heater in order to enhance heating capacity and performance. R410A has been employed as a working fluid and performance analysis has been conducted under various conditions. Results are summarized as follows: (1) The V-I system with the re-cooler yielded a marginally higher coefficient of performance (COP) than the conventional V-I refrigeration system. (2) By increasing the re-cooler cooling capacity, enhanced system performance as compared to the conventional V-I system was observed. (3) The re-heater negatively affected the system performance; hence, the V-I heat pump with the re-heater yielded a lower COP than that of the conventional V-I heat pump used for heating. (4) Although the solar panels increased the system performance, this increase could not offset performance degradation by the re-heater.

Study on the Collector Efficiency of an Air Heater in a Solar Air Conditioning System (태양열 이용 냉난방 공조시스템 중 공기식 집열기의 집열효율에 관한 연구)

  • Kim, B.C.;Shin, H.J.;Choi, K.H.;Kum, J.S.
    • Solar Energy
    • /
    • v.20 no.4
    • /
    • pp.1-8
    • /
    • 2000
  • The suggested year round solar air conditioning system has been developed for cooling and heating. In particular, this system focused on cooling and dehumidification and it could reduce a peak time owing to the use of air conditioners in summer. This study was performed to find out how much heating loads could be saved and furthermore whether this suggested system would be possible to do heating without a switch of system in real situations. Through model house experiments, the following conclusions were obtained. 1) The collector efficiency was 36% at maximum, but more improved structure of suggested collector could increase its efficiency. 2) The temperature of outlet air was about $30^{\circ}C$ and it could reduce heating loads. 3) Measured temperature and calculated one agreed well within ${\pm}1.5^{\circ}C$.

  • PDF