Comparison of Optimum Design due to the Structure of the Regenerative Evaporative Cooler (재생증발실 냉각기의 구조에 따른 최적설계 비교)

  • Choi, Bong-Su;Hong, Hi-Ki;Lee, Dae-Young
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.359-364
    • /
    • 2005
  • In dehumidification evaporation cooling system. the regeneratie evaporative cooler(REC) makes an important role to reduce the sensible cooling load in the system through evaporative cooling, By this reason, many studies about increasing the cooling capacity of the REC were undertook. In this paper, we analyzed the cooling characteristics of the REC due to the structures of the REC and determined the best structure for the REC's effectiveness and cooling capacity. From the study. we could obtain some important results: at first. corrugated type has the benefit to expand the channel width of the REC, But because the type has some weak points about the size and weight. there is almost no benefit to improve the performance of the REC. Through these reasons. we decided that finned type is the best structure to improve the performance of the REC.

  • PDF

The Study on Performance Characteristics due to the Degree of Superheat in Freon Refrigerating System (The Comparison of Heat Exchanger Types) (프레온 냉동장치의 과열도에 관한 성능 특성 연구 (열교환기 타입별 비교))

  • Jeong, Song-Tae;Ha, Kyeong-Soo;Kim, Yang-Hyun;Park, Chan-Soo;Ha, Ok-Nam;Lee, Seung-Jae
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.486-491
    • /
    • 2005
  • Nowadays heat exchangers that have been applied for freon refrigerating systems, a shell and tube type condenser, but because of their large size, large space for installation and more amount of refrigerants are needed. Therefore, in this study, we will find the most suitable operating condition through the comparison of performance between the shell & tube type and shell & disk type heat exchanger with R22. The experiments are carried out for the condensing pressure of refrigeration system from 1500kPa to 1600kPa and for the degree of superheat from 0 to $1^{\circ}C$ at each condensing pressure. As a result of experiment, if the shell & disk type heat exchanger is applied for R22 refrigerating systems, minimized input of refrigerants and space required for installation will be secured, which will have a great contribute to financial improvement for industry.

  • PDF

Construction of Ground Effective Thermal Conductivity Database for Design of Closed-Loop Ground Heat Exchangers (밀폐형 지중열교환기 설계를 위한 지중 유효열전도도 데이터베이스 구축)

  • Choi, Jae-Ho;Sohn, Byong-Hu;Lim, Hyo-Jae
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.776-781
    • /
    • 2008
  • A ground heat exchanger in a GSHP system is an important unit that determines the thermal performance of a system and its initial cost. The Size and performance of this heat exchanger is highly dependent on the thermal properties. A proper design requires certain site-specific parameters, most importantly the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. This paper is part of a research project aiming at constructing a database of these site-specific properties, especially ground effective thermal conductivity. The objective was to develop and evaluation method, and to provide this knowledge to design engineers. To achieve these goals, thermal response tests were conducted using a testing device at nearly 150 locations in Korea. The in-situ thermal response is the temperature development over time when a known heating load imposed, e.g. by circulating a heat carrier fluid through the test exchangers. The line-source model was then applied to the response test data because of its simplicity. From the data analysis, the range of ground effective thermal conductivity at various sites is $1.5{\sim}4.0\;W$/mK. The results also show that the ground effective thermal conductivity varies with grouting materials as well as regional geological conditions and groundwater flow.

  • PDF

Experimental Study on the Drag Reduction & Heat Transfer Ratio in the Circular Pipe with Swirl Generater (난류발생기를 가지는 원형 파이프내에서의 마찰저감 및 열전달율에 관한 실험적 연구)

  • Kim, Seong-Su;Cho, Sung-Hwan;Yoon, Seok-Mann
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.430-435
    • /
    • 2008
  • Total lengths of domestic pipe network for district heating system are above about 2,500Km. A lots of pumping power for heat transportation through long pipe are required by the flow friction of pipe surface. Until now there have been considered about various methods to reduce the flow friction for district heating system such as using surfactants and turbulence promoters by swirl flow and baffles etc. At this study, swirl flow generator was tested about the possibility to increase the heat transfer ratio at the heat exchanger in the case which the suppling water temperature increased from $50^{\circ}C$ until $120^{\circ}C$. Experimental results showed that the heat transfer ratio increased and also pressure increase ratio increased simultaneously in the case which swirl flow generator installed. The amount of the increasing ratio for heat transfer and pressure were reached until 4.33% and 11% at the case of $120^{\circ}C$ suppling temperature which domestic district heating system were using.

  • PDF

The Study of a Atomizing Characteristics of a Multi-Nozzle in a Fire Extinguishing System (소화 시스템에서 다중노즐의 분무특성에 관한 연구)

  • Jung, Young-Kwon;Kim, E.;Kim, Young-Soo;Kim, In-Kwan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1178-1183
    • /
    • 2008
  • This paper is about a study of atomizing characteristics of a Multi-Nozzle, which is an important part in a flooding water mist system for extinguishing fires broke out in ships. Comparing the results of experiments for the Single-Nozzle to that of numerical analyses, characteristics of a Multi-Nozzle can be found out. In situation of a Single-Nozzle’s, the atomizing angle was $34^{\circ}$. And in situation of Multi-Nozzle that combined with 5 single-nozzles, the atomizing angle increase to $125^{\circ}$. The effective area is 3.7 times of the former. The quality factor will reduce, if the diameter of the atomizing region of the nozzle reduces. Although the atomizing angle is reduced because of the atomizing property, the value of SMD still shows a good result.

  • PDF

Cost Estimating of Heat and Electricity on a Gas-Turbine Cogeneration (가스터빈 열병합발전에서 생산된 열과 전기의 원가산정)

  • Kim, Deok-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.351-356
    • /
    • 2008
  • When various kinds of outputs are produced from a single energy system, the methodology which allocates the common cost to each output cost is very important because it is directly related with the profit and loss of producers and purchasers. In the cost allocation methodology of the heat and the electricity on a cogeneration, there are energy method, work method, proportional method, benefit distribution method, various exergetic methods, and so on. On the other hand, we have proposed a worth evaluation method which can be applied to any system. The definition of this methodology is that the unit cost of a product is proportion to the worth. Where, worth is a certain evaluating basis that can equalize the worth of products. In this study, we applied this methodology to a gas-turbine cogeneration which produces 119.2 GJ/h of electricity and 134.7 GJ/h of heat, and then we allocated 3,150 $/h of fuel cost to electricity cost and heat cost. Also, we compared with various cost allocation methods. As the result, we conclude that exergy of various kinds of worth basis evaluates the worth of heat and electricity most reasonably on this system.

  • PDF

Assessment for the effect of heating systems on the energy consumption and environment (개별난방과 지역난방방식의 에너지절감 및 환경개선효과 분석)

  • Im, Yong-Hoon;Kim, Hyouck-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.466-473
    • /
    • 2007
  • The comparison for the performance of heating systems, district heating and separate heating and power, is carried out in terms of energy consumption and environment on the basis of real operating data. The efficiency of boiler and the heat loss within the housing are assumed with reasonable manner due to the lack of reliable data regarding those quantities. The assessment for the established criteria of previous studies is performed and the new criteria for the analysis is proposed. It is shown that the district heating system is superior to the separate heating and power system from the point of view of reduction of energy use and environment improvement. The sensitivity study for those quantities with uncertainty such as the boiler efficiency and heat loss within the housing is carried out also and the reasons for the analysis results are discussed in detail.

  • PDF

An Experimental Study on PAG and POE Oils Return in $CO_2$ Evporator Model ($CO_2$ 냉동시스템 증발기에서 PAG 및 POE 오일 회수에 관한 실험적 연구)

  • Lee, Sung-Kwang;Kang, Byung-Ha;Kim, Suk-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.646-651
    • /
    • 2007
  • This study has been conducted to select the suitable refrigeration oil for a $CO_2$ refrigeration system. The oil return is one of the most important characteristics for refrigeration oils. PAG and POE oils are considered as a test fluids in this study. An evaporator model is employed to simulate the evaporator of a $CO_2$ refrigeration system. Oil return characteristics has been investigated for $CO_2$/PAG and $CO_2$/POE mixtures in the range of oil concentration 0 to 5 weight-percent and the mixture temperature range of $0^{\circ}C$ to $15^{\circ}C$. The results obtained indicate that oil return is decreased with an increase in the oil concentration and mixture temperature for both POE and PAG oils. It is also found that POE oil is seen to be superior than PAG oil in terms of oil return in an evaporator of a $CO_2$ refrigeration system.

  • PDF

Application analysis to a shared apartment house of heat storage type GSHP system with dual storage tank (이중 축열조를 갖는 축열식 지열원 히트펌프시스템의 노인공동주택 적용 분석연구)

  • Park, Jong-Woo;Lee, Sang-Hoon;Cho, Sung-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.27-32
    • /
    • 2008
  • The present study has been conducted economic analysis of heat storage type ground source heat pump system(HSGSHP) and normal ground source heat pump (GSHP) which are installed at the same building in the shared an apartment house. Cost items, such as initial cost, annual energy cost and maintenance cost of each system are considered to analyze life cycle cost (LCC) and simple payback period (SPP) with initial cost different are compared. The initial cost is a rule to the Government basic unit cost of production. LCC applied present value method is used to assess economical profit of both of them. Variables used to LCC analysis are prices escalation rate and interest rate mean values of during latest 10 years. The LCC result shows that HSGSHP (1,050,910,000won) is more profitable than GSHP by 68.9% initial cost. And SPP appeared 3.0 year overcome the different initial cost by different annual energy cost.

  • PDF

Thermal Conductivity measurement of Binary Nanofluids by the Transient Hot-wire Method (비정상 열선법을 이용한 이성분 나노유체의 열전도도 측정)

  • Cho, Chang-Hwan;Sul, Hea-Youn;Koo, June-Mo;Kang, Yong-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.165-169
    • /
    • 2008
  • Binary nanofluids(Binary mixture + nanoparticles) have been extensively paid attention for application in absorption system as a new working fluid. Thermal property evaluation of the new refrigerants is inevitable to apply them for actual system. The objectives of this paper are to measure the thermal conductivity of the binary nanofluids by the transient hot-wire method, and to assess the application possibility of the binary nanofluids for absorption system. It was found that the thermal conductivity of the binary nanofluids ($H_2O/LiBrAl_2O_3$) increased with increasing the concentration of the nanoparticles ($Al_2O_3$) and enhanced up to 27% at 0.1 vol % of the nanoparticles.

  • PDF