• 제목/요약/키워드: Air-breathing

검색결과 277건 처리시간 0.026초

인체 호흡 영역에서의 대구시 대기질에 관한 연구 (Breathing Zone Air Quality in Taegu)

  • 조완근;손상호
    • 한국환경과학회지
    • /
    • 제5권1호
    • /
    • pp.7-14
    • /
    • 1996
  • Two experiments were conducted to evaluate breathing zone air quality in Taegu, using automatic analyzers for four air quality standards($SO_2$, $NO_2$, CO, and $O_3$). First, air target compounds were measured for 8 to 12 hours in each of two commercial areas and five residential areas. Second, air target compounds were hourly measured for 24 hours in each of two commercial areas, two residential areas, and an industrial complex area. Based on the first experiment the breathing zone air was more polluted in the commercial area as compared to the residential area, while the second experiment showed that the breathing zone air was polluted rather in the residential are3 as compared to the commercial area. The second experiment also indicated that there was some variation of breathing zone air concentration with time and measuring sites. Diurnal variation of breathing zone air concentrations was consistent with previous studies which measured at building height. The highest breathing zone air concentration was shown in Seongseo industrial complex area. An unusual finding of this study was that $SO_2$ concentration in the breathing zone air of Bisandong, a typical residential area of Taegu, was higher than that of other residential areas, even higher than that of Seongseo industrial complex area.

  • PDF

Analysis on the Age of Air and the Air Change Effectiveness of the Personal Environmental Module System in Intelligent Buildings

  • Cho, Dongwoo
    • Architectural research
    • /
    • 제1권1호
    • /
    • pp.47-53
    • /
    • 1999
  • An interesting of desktop air-conditioning system is the Personal Environmental Module(PEM) System. The PEM system allows the occupant to choose the desired temperature, air volume and direction of the discharged air. In this study, the measurements on the age of air and the air change effectiveness, using the tracer gas method, are carried out to analyze the ventilation performance for provision of fresh air near the breathing zone by the PEM. The relations between the PEM for optimal control and other factors related to indoor air quality, and the ventilation for the PEM are examined. Also, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The minimum local age of air was measured in the breathing zone, which is directly supplied with air from the PEM diffusers, and the measured local air change effectiveness of the desktop diffuser in the breathing zone was about 1.13 to 1.23 times greater than that of the ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

비상호흡법 적용을 통한 공기호흡기 사용시간 증가에 관한 연구 (A Study on the Increase of the Time of Air Respirator Using Emergency Breathing Method)

  • 김구태
    • 대한안전경영과학회지
    • /
    • 제24권3호
    • /
    • pp.1-14
    • /
    • 2022
  • This study is a plan on the way to strengthen the survival ability by increasing the use time of air respirator by applying emergency breathing method in the situation where firefighter has to wait for RIT (Rapid Intervention Teams) because it is impossible to escape by himself or emergency escape during isolation during field activities. The research procedure first drew problems by conducting a survey on fire fighters under the Seoul Fire and Disaster Headquarters, and conducted an experiment to compare normal breathing and emergency breathing with 20 members of the Seoul 119 Special Rescue Team, and suggested emergency breathing method and training process modeling that can be applied to each field situation based on the data obtained. The experiment was conducted over 9 weeks, and it was divided into three categories: field activity situation, movement (emergency escape assumption) situation, and place (assume waiting for RIT). In the field activity situation experiment, it was confirmed that the application of skip breathing method was appropriate and the use time of air respirator increased about 1.6 ~ 1.9 times. In the moving situation or the in-situ situation, wheel breathing method was appropriate and the use time of air respirator increased about 1.6 ~ 2.4 times. However, when conducting intense activities in the field activity situation, it is recommended to use it limitedly because it is difficult to apply the emergency breathing method. If emergency breathing is not clearly learned in the body, it is difficult to use in the field, so I think systematic and continuous training is necessary. This study suggests that the application of emergency breathing method is effective enough to strengthen the survival ability of firefighters in the field.

공기 호흡형 고분자 전해질 연료전지 제작 및 발전 특성 연구 (THE OPERATING CHARACTERISTICS IN AN AIR-BREATHING POLYMER ELECTROLYTE FUEL CELL)

  • 손영준;박구곤;엄석기;임성대;양태현;윤영기;이원용;김창수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.277-280
    • /
    • 2005
  • Air-breathing polymer electrolyte membrane fuel cells (PEMFC) are highly promising particularly for small-power applications up to tens watts class. A distinctive feature of the air-breathing PEMFC is its simple system configuration in which axial fans operate for dual purposes, supplying both oxidant and coolant in a single manner. In the present study, a nominal SOW air-breathing PEMFC system is developed and investigated to determine the optimal operating strategy through parametric studies (i.e., reactant humidity, and fan-blowing flow rate). The cell voltage distributions are examined as a function of time to evaluate the system performance under various operating conditions.

  • PDF

공기호흡형 고분자연료전지의 운전특성에 대한 연구 (The Operating Characteristics of Air-Breathing Type PEFCs)

  • 손영준;임성대;박구곤;김경연;김민진;이원용
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.44-46
    • /
    • 2008
  • Air-breathing polymer electrolyte membrane fuel cells (PEMFC) are highly promising particularly for small-power applications up to tens watts class. A distinctive feature of the air-breathing PEMFC is its simple system configuration in which axial fans operate for dual purposes, supplying both oxidant and coolant in a single manner. In the present study, a nominal 80W air-breathing PEMFC system is developed and investigated to determine the optimal operating strategy through parametric studies (i.e., reactant humidity, and fanblowing flow rate). The cell voltage distributions are examined as a function of time to evaluate the system performance under various operating conditions.

  • PDF

Ventilatory Responses to Continuous Negative Pressure Breathing(CNPB) in Awake Dogs

  • Cha, Eun-Jong;Goo, Yong-Sook
    • The Korean Journal of Physiology
    • /
    • 제27권1호
    • /
    • pp.37-49
    • /
    • 1993
  • Ventilatory responses to inhaled $CO_2$ were measured during continuous negative pressure breathing (CNPB) in awake dogs. End expiratory lung volume (EELV) decreased linearly with pressure level during CNPB (correlation coefficient= 0.81, p<0.005) during air breathing. When CNPB was applied during 5% $CO_2$ inhalation, the decrease in EELV was not significantly different (p<0.5) from that during air breathing. As a result of a lowered EELV, tidal volume ($V_T$) significantly decreased by 22% and breathing frequency ($f_B$) increased by 68% in the steady state during air breathing (p<0.0001). These responses were similar during 5% $CO_2$ inhalation, thus the $CO_2$ response curve measured during CNPB shifted upward without a change in sensitivity (p>0.05). These results indicate additive effects of CNPB and $CO_2$ inhalation. The degree of hyperventilation during CNPB at eupnea was estimated to be 63% of that during control ventilation and was significantly greater than zero (p<0.0001), which suggests an alveolar hyperventilation due to CNPB. These results suggest that the mechanical alterations associated with n decrease in lung volume could play an important role in ventilatory control independently of chemical regulation of breathing. Thus, exercise hyperpnea, which is associated with a lowered functional residual capacity (FRC), may in part be explained by this mechanical stimulation of breathing.

  • PDF

극초음속 공기흡입식 추진기관 지상 시험설비의 구성 및 특성에 관한 연구 (A Study on the Hypersonic Air-breathing Engine Ground Test Facility Composition and Characteristics)

  • 이양지;강상훈;양수석
    • 한국추진공학회지
    • /
    • 제19권6호
    • /
    • pp.81-90
    • /
    • 2015
  • 램제트 엔진, 스크램제트 엔진과 같은 극초음속 공기흡입식 추진기관을 지상에서 시험하기 위해서는 극초음속 추진기관이 작동하는 고고도, 고 마하수 환경을 모사해야 한다. 따라서 고압, 고온 환경을 조성하여 고고도 고 마하수 환경을 지상에서 구현해야 한다. 본 논문에는 한국항공우주연구원에서 설계 및 제작한 극초음속 공기 흡입식 추진기관 지상 시험설비의 구성과 특성에 대하여 소개한다.

차세대 극초음속 공기흡입식 추진기관의 개발 동향 (Current Technological Trends in Hypersonic Flight with Air-Breathing Propulsion System)

  • 이양지;강상훈;양수석
    • 항공우주산업기술동향
    • /
    • 제7권1호
    • /
    • pp.43-55
    • /
    • 2009
  • 20세기 전반 극초음속 공기흡입식 추진시스템에 대한 개념이 정립된 이래 항공우주기술선진국은 이러한 개념을 구현하기 위하여 꾸준히 연구를 진행하였으며 2004년 NASA의 X-43A Hyper-X가 마하 10의 극초 음속 공기흡입식 비행을 성공적으로 수행하였다. 현재 각 국에서는 이러한 극초음속 공기흡입식 추진시스템을 SSTO(Single Stage to Orbit) 또는 TSTO(Two Stage to Orbit) 개념의 재사용 위성 발사체 및 극초음속 미사일에 적용하기 위한 프로젝트가 본격적으로 진행되고 있다. 본 논문에는 미국, 유럽, 호주 아시아에서 개발하고 있는 극초음속 공기흡입식 추진시스템의 역사 및 현황과 이러한 추진시스템을 적용한 비행체, 미사일 개발 연구를 정리하였다.

  • PDF

공조취출방식에 따른 공기의 나이 및 환기효율 비교 (Comparison of age of air and air change effectiveness between supply diffuser types)

  • 조동우
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.117-124
    • /
    • 1999
  • In this study, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The measurements on the age of air and the air change effectiveness using the tracer gas method are carried out to analyze the ventilation performance for provision of fresh air between the diffusers. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The measured local air change effectiveness of the desktop diffuser in the breathing zone was usually 1.13 to 1.23 times greater than that of ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

공기 흡입 엔진의 총추력 및 측추력 분석 (Analysis of Gross Thrust and Side Thrust of Air-Breathing Engine)

  • 김정우;정치훈;안동찬;이규준
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.572-582
    • /
    • 2017
  • 공기 흡입 엔진을 개발하기 위해서는 지상 시험을 통한 추력 측정이 반드시 필요한데, 공기 흡입 엔진은 추력 측정 장치에서 측정된 값 이외에도 엔진 흡입구로 들어오는 공기 유동에 의한 힘을 고려하여 총추력을 계산해야 한다. 또한 다분력 추력 측정 장치를 활용하여 요와 피치 방향의 측추력도 정확하게 측정하고 분석할 수 있어야 한다. 래버린스 씰 격리, 1축 총추력 계산, 다분력 추력 측정 장치 개발, 측추력 분석 등의 일련 과정을 통해 공기 흡입 엔진의 총추력을 정밀하게 추정하여 엔진 성능을 보다 정확하게 평가할 수 있게 하였다.

  • PDF