• Title/Summary/Keyword: Air-Water

Search Result 6,838, Processing Time 0.051 seconds

Comparison and Analysis of Zircaloy-4 Tube Wear in Air and Water Environment (수중 및 공기 중에서의 지르칼로이-4 튜브마멸 비교분석)

  • 김형규;박순종;강흥석;윤경호;송기남
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.19-26
    • /
    • 2001
  • The wear characteristic of Zircaloy-4 tube, which is used for a cladding of light water reactor fuel rod, is investigated experimentally. The experiment is conducted with contacting the crossed tube specimens in air as well as in water at room temperature with various combination of contact normal force and sliding distance of reciprocating motion. The contour and the volume of each wear are examined to study the effect of contact condition and environment on wear. As a result, it is found that the wear volume in the water environment is larger than that in the air for all the contact (i.e., force and sliding distance) conditions. However, the wear depth is greater in air than in water if the contact normal force and the sliding distance are larger. These are explained by the ease of detachment of wear particles from the contact surface. On the other hand, workrate model is applied with the contact shear force range measured by our wear tester. Investigated is the correlation between the workrate and the wear volume increase rate of the present experiment. The parabolic curve is found to fit well for the present wear data.

  • PDF

Study on Design of Air-water Two-phase Flow Centrifugal Pump Based on Similarity Law

  • Matsushita, Naoki;Furukawa, Akinori;Watanabe, Satoshi;Okuma, Kusuo
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.2
    • /
    • pp.127-135
    • /
    • 2009
  • A conventional centrifugal pump causes a drastic deterioration of air-water two-phase flow performances even at an air-water two-phase flow condition of inlet void fraction less than 10% in the range of relatively low water flow rate. Then we have developed a two-phase flow centrifugal pump which consists of a tandem arrangement of double rotating cascades and blades of outer cascade have higher outlet angle more than $90^{\circ}$. In design of the two-phase flow pump for various sized and operating conditions, similarity relations of geometric dimensions to hydraulic performances is very useful. The similarity relations of rotational speed, impeller diameter and blade height are investigated for the developed impeller in the present paper. As the results, the similarity law of rotational speed and impeller diameter is clarified experimentally even in two-phase flow condition. In addition, influences of blade height on air-water two-phase flow performances indicate a little difference from the similarity relations.

Properties of Water-based Paint mixed with Photocatalyst for Indoor Air Quality Improvement (실내 공기질 개선을 위한 광촉매를 혼입한 수성도료의 특성)

  • Choi, Byung-Cheol;Park, Chae-Wool;Kyoung, In-Su;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.29-30
    • /
    • 2020
  • As the modern society enters, the building becomes sealed and the public's interest in the environment increases, so the interest in indoor air pollution increases and the environmental pollution is raised as an important issue not only outdoors but also indoors. In addition, the emergence of sick house syndrome (SHS) has increased the interest in formaldehyde and is a cause of deteriorating indoor air quality. Accordingly, this study prepared a functional paint by incorporating a photocatalyst in an aqueous paint, and conducted formaldehyde adsorption experiments and functional evaluation. As a result of the experiment, as the photocatalyst was added, the formaldehyde adsorption performance tended to increase. In addition, as a result of measuring the impact resistance and alkali resistance according to the KS standard, there is no difference in residual cracks and cracks between the water-based paint without the photocatalyst and the water-based paint with the photocatalyst added. Therefore, it is considered that the water-based paint added with a photocatalyst can improve the indoor air quality by adsorbing formaldehyde and can be used as a functional paint because the functionality is not different from that of a general water-based paint.

  • PDF

Physicochemical Properties of Soybean Curd Residue Powder by Different Soybean and Drying Methods (콩의 종류와 건조 방법에 따른 비지 분말의 이화학적 특성)

  • Eun Ji Kim;Hee Nam Jung
    • Journal of the Korean Society of Food Culture
    • /
    • v.38 no.5
    • /
    • pp.356-364
    • /
    • 2023
  • This study compared the physicochemical properties of soybean curd residue and black soybean curd residue produced by hot air-drying and freeze-drying. Regardless of drying method, the crude protein, crude ash, crude fiber contents, pH, L, a, b color values and water soluble index were higher in soybean curd residue, whereas total polyphenol contents and antioxidant activity were higher in black soybean curd residue. Significant differences in water absorption index, oil absorption capacity and emulsion activity were observed between soybean curd residue and black soybean curd residue in freeze-drying. On the other hand, the emulsion stability was not significant difference in both hot-air drying and freeze-drying. The crude protein and crude fiber contents of soybean curd residue were not significant difference between hot-air drying and freeze-drying. Freeze-drying resulted in higher crude ash contents, pH, water absorption index, water soluble index, oil absorption capacity, emulsion activity and emulsion stability than hot-air drying. Hot-air drying have caused significantly higher water contents, water activity, total polyphenol contents and antioxidant activity in soybean curd residue than freeze-drying. In conclusion, soybean type and drying methods affect the physicochemical and quality characteristics of soybean curd residue, which could be important factors in the manufacture of processed foods.

An Experimental Study on Energy Consumption of Air Washer Outdoor Air Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 에어와셔 외기공조시스템의 에너지소비량에 관한 실험적 연구)

  • Kim, Ki-Cheol;Kim, Hyung-Tae;Song, Gen-Soo;Yoo, Kyung-Hoon;Son, Seung-Woo;Shin, Dae-Kun;Park, Dug-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.297-305
    • /
    • 2012
  • In recent large-scale semiconductor manufacturing clean rooms, the energy consumption of outdoor air conditioning systems to heat, humidify, cool and dehumidify incoming outdoor air represents about 45% of the total air conditioning load required to maintain a clean room environment. Therefore, the energy performance evaluation and analysis of outdoor air conditioning systems is useful for reducing the outdoor air conditioning load for a clean room. In the present study, an experiment was conducted to compare the energy consumption of outdoor air conditioning systems with a simple air washer, an exhaust air heat recovery type air washer and a DCC return water heat recovery type air washer. It was shown from the present lab-scale experiment with an outdoor air flow of 1,000 $m^3/h$ that the exhaust air heat recovery type and DCC return water heat recovery type air washer outdoor air conditioning systems were more energy-efficient for the summer and winter operations than the simple air washer outdoor air conditioning system and furthermore, the DCC return water heat recovery type one was the most energy-efficient in the winter operation.

EXPERIMENTAL STUDY OF TURBULENCE MANIPULATION IN STEPPED SPILLWAYS. IMPLICATIONS ON FLOW RESISTANCE IN SKIMMING FLOWS

  • GONZALEZ CARLOS A.;CHANSON HUBERT
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.09a
    • /
    • pp.588-589
    • /
    • 2005
  • Current expertise in air-water turbulent flows on stepped chutes is limited to laboratory experiments at low to moderate Reynolds numbers on flat horizontal steps. In this study, highly turbulent air-water flows skimming down a large-size stepped chute were systematically investigated with a $22^{\circ}$ slope (Fig. 1). Turbulence manipulation was conducted using vanes or longitudinal ribs to enhance interactions between skimming flows and cavity recirculating regions (Fig. 2). Systematic experiments were performed with seven configurations. The results demonstrated the strong influence of vanes on the air-water flow. An increase in flow resistance was observed consistently with maximum flow resistance achieved with vanes placed in a zigzag pattern.

  • PDF

An Experimental Study on the Characteristics of Bubbles in Air-Water Model (Air-Water 모델에서 기포특성에 관한 실험적 연구)

  • 오율권;서동표
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.1
    • /
    • pp.14-18
    • /
    • 2003
  • The structural development of air-water bubble plumes has been measured under different condition on air flow rate in a cylindrical bath. The time-averaged structure of plumes has been measured with an oscilloscope and an electro-conductivity probe. The temperature of bubbles was also obtained by a thermal-infrared camera. Gas volume fraction and bubble frequency were high since bubbles concentrated on the nozzle. In general, their axial and radial values tended to decrease with increasing distance. Bubble temperature reached water temperature within a short time. The present study showed that thermal equilibrium between bubbles and water was completed before bubbles flow became stable.

Effects of Water Repellency Treated ALC Powder on the Properties of Mortar Mixed with ERCO (발수 처리한 ALC 분말이 유화처리 정제유지류(ERCO) 혼입 모르타르의 품질특성에 미치는 영향)

  • Lee, Myung-Ho;Park, Jun-Hee;Kim, Sang-Sup;Park, Jae-Yong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.112-113
    • /
    • 2014
  • This study was done to resolve the air reduction in mortar when mixed with ERCO. Effects of the water repellent ALC powder due to its particle size and substitution ratio on the cement mortar with ERCO was analyzed. Results showed more water repellent ALC powder ensured more air but did not affect the size of particles. It was determined the compression was caused by more air and water added to achieve the flow. Therefore, substituting with water repellent ALC powder may compensate for the air reduction in mortar with ERCO. Other measures and approaches are needed in order to resolve the reduced strength.

  • PDF

Effect of Temperature and Immersion Time on the Environmental Adhesive Strength of Adhesively Bonded Joints of Rolled Steel Sheet (압연강판 접착제 접합부의 환경 접합강도에 미치는 온도 및 침수시간의 영향)

  • Song, Jun-Hee;Lee, Hee-Jae;Lim, Jae-Kyoo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.12
    • /
    • pp.2662-2669
    • /
    • 2002
  • Recently structural applications of adhesive bonding method have been increased extensively in automobile industry. Adhesively-bonded joints which are used in automobile field are exposed to various environmental conditions. In this study, several environmental factors were concerned to evaluate their effects on the adhesive strength such as air temperature, water temperature, exposed time in water. The specimens are exposed for 1, 10 and 100 hours at various air temperatures to evaluate the effects of the air and water temperature on the adhesive strength. It is proved that the adhesive strength decrease with rising the air and water temperature, and the adhesive strength decrease steeply at the higher temperature with increasing the exposure time in water.

Natural Convection Heat Transfer in Inclined Cylindrical Water Layers (경사진 원형 수층에서의 자연대류 열전달)

  • 장병훈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.787-794
    • /
    • 2003
  • The effect of inclination angle on natural convection heat transfer has been studied for water layers. The range of the Raleigh number was from the subcritical value to 1.4${\times}$10$^{7}$ , and the range of the inclination angle, $\theta$, measured from the horizontal was 0$\leq$$\theta$$\leq$180$^{\circ}$. For horizontal water layers, present results agreed well with the results of previous investigators and also showed significant departures from the results of air layers in the turbulent regime. Inclined cylindrical water layers showed secondary maxima in heat transfer, whereas rectangular air layers showed continuous decline of Nusselt number.