• 제목/요약/키워드: Air-Tubes

검색결과 495건 처리시간 0.028초

냉매와 습공기가 교차하는 2중관에서 전열계수 예측을 위한 연구 (The study on the estimation of heat transfer coefficient through the counterflow concentric tube using refrigerant and moisture air)

  • 조권희
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권5호
    • /
    • pp.687-694
    • /
    • 1999
  • This study was conducted to develop new drying process for automatic control and marine engi-neering system. Air-water tests were carried out to investigate dryer performance. The dispersed flow in he dryer test apparatuses was also simulated by using a numerical code which solves the Dittus-Boelter equation for continuous liquid phase and the Reynolds equation of droplet motion for continuous liquid phase and the Reynolds equation of droplet motion for dispersed phase to predict droplet removal efficiency. Proper conditions for dehumidification were optimized by response ambient conditions. When the selected indexes were constrained in the range of 85-98% moisture content above $15^{\circ}$ and more than mass flow rates of moist air 750kg/h. The numerical results were compared with the experimental data pertaining to the removal effi-ciency at chamber stage and overall pressure drop along concentric tubes Good agreement was obtained as for the efficiency while relatively poor agreement was obtained for the relative humidity. The results also showed that the efficiency depended strongly on the relative humidity at the inlet condition which indicated the importance of estimating the heat exchanger length. Effects of some design parameters in both removal efficiency and breakthrough onset condition are discussed.

  • PDF

공기 중에서 열증발법에 의하여 제작된 튜브 형상의 ZnO 결정 (Tubular-shaped ZnO Crystals by Thermal Evaporation Technique in Air)

  • 이정헌;이근형;남춘우
    • 한국전기전자재료학회논문지
    • /
    • 제27권3호
    • /
    • pp.141-145
    • /
    • 2014
  • Tubular-shaped ZnO crystals were synthesized by thermal evaporation technique under air atmosphere. Mixture of Zn and Mg powder was used as the source material. The thermal evaporation and oxidation of Zn/Mg mixture were carried out for 1 hr at $1,000^{\circ}C$ and $1,200^{\circ}C$ under in air under atmospheric pressure. When only Zn powder was used as a source material, tetrapod-shaped ZnO crystals were synthesized. This provides that Mg played a key role in the formation of the tubular-shaped crystals. SEM images showed that the tubular-shaped ZnO crystals grew along [0001] direction. XRD spectrum revealed that the ZnO tubes had hexagonal wurtzite structure. Two emission peaks at 380 nm and 510 nm were observed in the room temperature cathodoluminescence spectrum.

사인 웨이브 핀과 타원관으로 구성된 핀-관 열교환기의 공기측 습표면 성능 (Wet Surface Air-Side Performance of Fin-and-Tube Heat Exchangers Having Sine Wave Fins and Oval Tubes)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제16권4호
    • /
    • pp.2415-2423
    • /
    • 2015
  • 본 논문은 12.7mm 원관을 변형하여 만든 세장비 0.6(짧은 직경 10.0mm, 긴 직경 16.5mm)의 타원관이 적용된 사인 웨이브 핀-관 열교환기의 습표면 공기측 성능실험에 관한 것이다. 핀 핏치와 열 수를 변화시켜 총 12개의 시료에 대하여 실험을 수행하였다. 타원관에서 핀 핏치 변화에 따른 j, f 인자의 영향은 미미 하였으나, 열수에 따라서는 1row에서 j인자가 가장 낮았다 (가장 높은 2row의 81%). 하지만 원관에서는 1row에서 가장 높게 나타나는 차이점을 보였다. 이는 타원관에 적용된 사인 웨이브 채널의 유동 특성에 기인한 것으로 판단된다. 원관 열교환기와 $j/f^{1/3}$값을 비교한 결과 1열을 제외하고는 타원관 열교환기의 전열성능이 우수함을 알 수 있다. 즉, 타원관 열교환기의 $j/f^{1/3}$값이 원관의 값보다 2열에서 1.6~2.5 배, 3열에서 1.4~2.4 배, 4열에서 1.2~1.8배 크게 나타났다.

원전 증기발생기 전열관 확관법이 확관부위 잔류응력에 미치는 영향 (Effects of Expanding Methods on Residual Stress of Expansion Transition Area in Steam Generator Tube of Nuclear Power Plants)

  • 김용규;송명호
    • 에너지공학
    • /
    • 제21권4호
    • /
    • pp.362-372
    • /
    • 2012
  • 원전의 증기발생기 전열관은 압력경계 부위로 결함발생으로 인한 누설 시 방사능물질을 함유한 1차 계통의 냉각수가 2차 계통으로 새어나와 발전소 및 대기를 오염시키게 된다. 근래에 전열관의 균열결함은 대개 응력 부식균열이며 전열관의 확관부위, 슬러지 침적부위 그리고 U-bend 등에서 발생한다. 확관부위 및 U-bend 등에서의 균열발생인자 중 가장 영향을 미치는 인자는 잔류응력이다. 폭발확관법이 적용된 한국표준형원전(OPR-1000)의 운전경험에 따르면, 증기발생기 전열관 확관부위에서 가동 초기부터 응력부식균열이 발생해 왔으며, 특히 원주방향 균열이 대량 발생하고 있다. 따라서 본 연구에서는 확관방법에 따른 잔류응력의 분포 및 상태를 비교하였으며, 특정 방향이 우세한 원인을 살펴보았다.

증발식 다중효용 담수기에서 열교환기 튜브 배열 및 형상에 따른 액막 유동에 관한 수치해석 (Numerical Study of Liquid Film Flow on Heat Exchanger Tube Arrangement and Configuration of Multi Effect Distillation)

  • 정일영;윤상국;주홍진;곽희열
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.68-73
    • /
    • 2011
  • This study was performed numerical analysis in order to analyze liquid film flow of heat exchanger tube arrangement and configuration of evaporative multi effect distillation system using medium-temperature. Simulation was accomplished the two-dimensional calculations using commercial analyses program FLUENT based on the FVM(finite volume method). Fresh water generator of this study used Shell & Tubes heat exchanger with Cu_Ni tube, configuration of tube used bare tube and corrugated tube, and arrangement of tube used in-line array and staggered array. Performance of heat exchanger through the formation of liquid film was compared and analyzed. Liquid film flow occurred that falling on heat exchanger tube wall. Result of simulation showed that liquid film thickness of in-line arrangement was found 0.57mm with bare tube and 0.67mm with corrugated tube, respectively. And liquid film thickness of staggered arrangement was found 0.39mm with bare tubes and 0.62mm with corrugated tubes, respectively. Liquid film thickness of corrugated tube showed thicker than bare tube, but heat transfer rates of corrugated tube showed higher than bare tube. The reason was considered that surface area of corrugated tube was wider than bare tube. And liquid film thickness of staggered arrangement showed thinner than in-line arrangement, so thermal performance of staggered arrangement showed higher than in-line arrangement.

  • PDF

화력발전소용 슈퍼 듀플렉스 스테인리스 강(STS 329J4L) 조관 튜브 및 핀-튜브재의 부식거동 (Corrosion Behavior of Super Duplex Stainless Steel (STS 329J4L) Tubes and Fin-Tubes Used in Thermal Power Plant Applications)

  • 박진성;김용현;홍승갑;김성진
    • Corrosion Science and Technology
    • /
    • 제22권6호
    • /
    • pp.435-446
    • /
    • 2023
  • Corrosion behaviors of laser-welded super duplex stainless steel (SDSS) tubes after exposure to an actual power plant environment for one year and those of fin-tube welded SDSS were evaluated. Results showed that corrosion damage on the back side of the SDSS tube in the direction of hot air was higher than that on the front side regardless of weldment location. However, corrosion damage showed no difference between weldment and base metal due to recovery of phase fraction in the weldment through post weld heat treatment (PWHT). Nevertheless, the SDSS tube showed severe corrosion damage along grain boundary due to surface phase transformation (δ → γ) and Cr2N precipitation caused by PWHT with a high N2 atmosphere. Corrosion resistance of the SDSS tube was recovered when degraded surface was removed. Corrosion sensitivity of a fin-tube increased significantly due to pre-existing crevice, unbalanced phase fraction, and σ phase precipitation adjacent to the fusion line. Although corrosion resistance was improved by recovered phase fraction and sufficient dissolution of σ phase during PWHT, corrosion reaction was concentrated at the pre-existing crevice. These results suggest that welding conditions for fin-tube steel should be optimized to improve corrosion resistance by removing pre-existing crevice in the weldment.

ENVIROMENTAL CONDITION DURING AIR SHIPMENT OF HORTICULTURAL PRODUCTS FROM OKINAWA TO TOKYO

  • Akinaga, Takayoshi;Kohda, Yoshihiro
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.413-422
    • /
    • 1993
  • Air shipment affords the quickest possible delivery of horticultural products. The price of air shipped horticultural products are relatively high as most of these products are perishable. Usually the temperature in the cargo compartment is not controlled during flight. Thus, special attention should be paid to procooling prior to shipment. The environmental condition during transportation of horticultural products is an essential parameter for maintaining the quality of perishable products. Commonly horticultural products were loaded by ULD(Unit Load Devices) as a container or pallet in the aircraft (except for small aircraft) . Therefore, inside temperature of the container and cargo compartment came into question. Scarce literature on the relationship between environmental condition and quality changes of horticultural products during air shipment can be found. By the stand point of keeping fresh quality, investigations on the actual condition of air shipments were carried out to improve the technique during the distribution process of fresh horticultural products. Temperature, humidity, atmospheric pressure, carbon dioxide, ethylene, impacts, and changes in quality during the air shipment of snapbeans, okras and chrysanthemums were measured. Temperature was measured by recording thermometers, relative humidity by recording hygrometers, atmospheric pressure by a strain -guage type pressure sensor, carbon dioxide by testing tubes, ethylene by sampling bags and a gaschromatograph, impacts and vibrations by impact recorders and a 3D accelerometer. Relationships between environmental conditions and quality changes during air shipments were clarified. It was expected from investigations into actual shipments that the ventilation and insulation properties of air freight containers were related to the quality of agricultural products. Aircraft can no directly load and unload trucks into them. The transshipment is inclined to cause shocks and vibrations, and to invite damages within a short time.

  • PDF

열전달 촉진관에서 R22 대체냉매 및 R134a의 포화증기 온도변화에 따른 외부 응축 열전달계수에 관한 연구 (External Condensation Heat Transfer Coefficients of R22 Alternative Refrigerants and R134a According to the Saturated Vapor Temperature Change on an Enhanced Tube)

  • 유길상;황지환;박기정;정동수
    • 설비공학논문집
    • /
    • 제17권11호
    • /
    • pp.981-989
    • /
    • 2005
  • In this study, external condensation heat transfer coefficients (HTCs) are measured on a low fin tube and Turbo-C tubes at the saturated vapor temperature of $30^{\circ}C$, $39^{\circ}C$, and $50^{\circ}C$ for R22, R410A, R407C and R134a with the wall subcooled at $3{\~}8^{\circ}C$. The HTCs of all refrigerants decreased as increasing the saturation temperature from $30^{\circ}C$ to $50^{\circ}C$. This trend is due to better thermodynamic properties of the liquid phase at low temperature Beatty and Katz's prediction yielded a $20.0\%$ deviation for the low fin tube data. The heat transfer enhancement factors for the 26 fpi low fin tube and Turbo-C tubes are 4.0${\~}$5.5 and 3.0${\~}$8.1 respectively for the refrigerants tested. Finally the performance of Turbo-C tube is better than that of the low fin tube.

모세유관 바닥복사 냉·난방 시스템의 성능평가 (Performance Evaluation of the Capillary Tube Radiant Floor Cooling & Heating System)

  • 서유진;김태연;이승복
    • KIEAE Journal
    • /
    • 제12권4호
    • /
    • pp.89-95
    • /
    • 2012
  • At present, many countries are trying to reduce green gas emissions to mitigate the effects of these gases on climate change. Year after year, there have been efforts to cut energy use for heating and cooling. Heating and cooling systems, common in all forms of housing, are increasing due to the constant supply of new housing resulting from improvements in economic growth and the quality of life. Thus, studies related to the design of cooling and heating systems to improve energy efficiency are expanding. Among the new designs, radiant floor cooling and heating systems which use capillary tubes are becoming viable means of reducing energy use. Radiant floor cooling and heating systems which use capillary tubes are creative and sustainable systems in which cool and hot water is circulated into capillary tube which has small diameter. In this study, the cooling and heating performance of this type of capillary tube system is investigated in an experimental study and a simulation using TRNSYS. The results of the experimental study show that under a peak load, a capillary tube radiant floor cooling system using geothermal energy can achieve desired indoor temperature without an additional heat source. The set room air temperature is maintained while the floor surface temperature, PMV and PPD remain within the comfort range. Also, this system is more economic than a packaged air conditioner system due to its higher COP. The results of the simulation show that the capillary tube radiant floor heating system maintains set temperature more stable than a PB pipe radiant floor heating system due to its lower supply temperature of hot water. In terms of energy consumption, the capillary tube radiant floor heating system is more efficient than the PB pipe radiant floor heating system.

상반류(물/공기) 유동한계에 관한 연구 (Counter-Current Flow Limit of a Vertical Two Phase (Water/Air) Flow)

  • 오율권;조상진;김상녕;이종원
    • 대한기계학회논문집
    • /
    • 제15권1호
    • /
    • pp.308-322
    • /
    • 1991
  • 본 연구에서는 CCFL에 영향을 미치는 관의 크기, 길이, 주입구 형상 등 변화 에 대한 현상해석과 이의 영향을 고려한 관계식의 개발에 있다. 그러므로 본 실험에 서의 물의 주입량을 관에 수막(film)이 형성시킬 수 있는 유량으로 고정시킨 상태에서 공기의 유량을 증가시켜, CCFL이 발생하였을때 공기와 물의 유량을 측정하였다. 그 리고 관의 길이, 크기 그리고 물의 주입구 구조(예각, 둔간, 톱니, 다공)의 변화에 따 른 CCFL의 영향에 관하여 실험을 수행하였다.