• 제목/요약/키워드: Air-Catalyst

검색결과 442건 처리시간 0.025초

UV lamp와 TiO2 광촉매를 이용한 공기 정화에 관한 연구 (A Study of Air Freshing by UV lamp and TiO2 Catalyst)

  • 이건덕;우인성;황명환;이인복;김관중;박화용
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2011년도 춘계학술대회
    • /
    • pp.205-227
    • /
    • 2011
  • On this study, the test for air-purification was executed as using the UV lamp and the UV lamp on which the TiO2 catalyst had been deposited with glass fiber in the reactor chamber. It aimed at the basic data of air-purifier as assessing the features of removing abilities for various contaminants including CH3COOH, NH3, NO, and SO2 as varying the number of TiO2 coating, the wave of UV lamp, and the amount of additive CaO as variables.

  • PDF

모형소각로의 촉매에 의한 배기가스 정화특성에 관한 연구 (A study on the pollutant reduction using catalyst in model furnace)

  • 이용후;이화신;이진석;이도형
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권8호
    • /
    • pp.870-876
    • /
    • 2006
  • In proportion to the increase of industrial development, emission troubles were concerned as global issue. For these reasons, so many researchers and associated institutes effort to reduce pollution with new technology and various devices. As a kind of these methods, we used catalysts as a after-treatment system. At first, we made equipment of model furnace. And various catalysts were equipped at exhaust duct of combustion system, and excess air ratio(a), change cell numbers catalyst materials(Pt, Pd) were changed as experimental conditions. With these various condition, temperature. NOx, CO, HC, $CO_2$ and $O_2$ concentration were measured. As a result, NOx conversion increased with increasing of cell number in Pd catalyst. And Pt catalyst became 100% conversion at 200 and 300 cell. Also, Pt catalyst was better than Pd catalyst at a=1.5 in this condition. In addition, CO and HC concentrations were decreased at a = 1.5 with Pd catalyst.

좁은 간격의 두 벽면 사이에서의 메탄-공기 예혼합 화염 전파에 벽면 상태가 미치는 영향 (The Effect of Wall Condition on the Methane-air Premixed Flame Propagation between Narrow Two Walls)

  • 최원영;권혁모;이대훈;권세진
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제28회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.37-41
    • /
    • 2004
  • Quenching phenomena is one of major concern in development of millimeter or sub-millimeter scale micro combustor for the size of the combustor is near extinction condition. In this work we focused on the effect of combustor wall condition that was parameterized by Perovskite LSC($La_{0.8}$$Sr_{0.2}$$CoO_3$) redox catalyst. The experiment was done by variable gap-width 2D wall equipment. The flame was produced by premixed methane-air jet issuing from millimeter-scale slot burner and it propagated through the narrow gap of the walls. By comparison of flame behaviour near catalyst-coated wall and simple glass wall, we investigated the effect of possible surface reaction on quenching phenomena. The flame between two plates was observed where the gap of the plates was reduced stepwise from 20mm to a distance of quenching occurrence. The two flames with and without surface modification were almost same by observation. But the gap for the occurrence of quenching was increased between catalyst-coated wall. So we concluded that surface reaction close to combustor wall has a negative effect on micro combustion.

  • PDF

촉매 연소기에서 희박 예혼합기의 연소특성 (Combustion Characteristics of Lean Premixed Mixture in Catalytic Combustors)

  • 서용석;강성규;신현동
    • 대한기계학회논문집B
    • /
    • 제22권12호
    • /
    • pp.1681-1690
    • /
    • 1998
  • The aim of this paper is to investigate combustion characteristics of lean premixed mixture stabilized by catalytic surface reaction. The catalytic combustor consisted of a catalyst bed and a thermal combustor. The catalyst bed was made of two stage, Pd catalyst in the first stage and Pt catalyst in the second stage. Auto ignition of lean mixture took place in the thermal combustor. Ignition temperature was about $810{\sim}820^{\circ}C$ at the fuel-air ratio of 1.5~3.0 % and the mixture velocity of 11~18m/sec. The position of flame front in the thermal combustor moved toward back as preheat temperature increased and fuel-air ratio decreased. The f1ame supported by surface reaction was stabilized without any flame stabilizers. NOx emissions from the catalytic combustor were below 2.0 ppm ($O_2$ 15 %) when gas temperature was limited below $1350^{\circ}C$. This result demonstrates that NOx emission from the catalytic combustor is much low comparing with conventional combustors.

Development and validation of diffusion based CFD model for modelling of hydrogen and carbon monoxide recombination in passive autocatalytic recombiner

  • Bhuvaneshwar Gera;Vishnu Verma;Jayanta Chattopadhyay
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3194-3201
    • /
    • 2023
  • In water-cooled power reactor, hydrogen is generated in case of steam zirconium reaction during severe accident condition and later on in addition to hydrogen; CO is also generated during molten corium concrete interaction after reactor pressure vessel failure. Passive Autocatalytic Recombiners (PARs) are provided in the containment for hydrogen management. The performance of the PARs in presence of hydrogen and carbon monoxide along with air has been evaluated. Depending on the conditions, CO may either react with oxygen to form carbon dioxide (CO2) or act as catalyst poison, reducing the catalyst activity and hence the hydrogen conversion efficiency. CFD analysis has been carried out to determine the effect of CO on catalyst plate temperature for 2 & 4% v/v H2 and 1-4% v/v CO with air at the recombiner inlet for a reported experiment. The results of CFD simulations have been compared with the reported experimental data for the model validation. The reaction at the recombiner plate is modelled based on diffusion theory. The developed CFD model has been used to predict the maximum catalyst temperature and outlet species concentration for different inlet velocity and temperatures of the mixture gas. The obtained results were used to fit a correlation for obtaining removal rate of carbon monoxide inside PAR as a function of inlet velocity and concentrations.

연료량 변조법에 의한 연료분사식 가솔린엔진의 공연비 제어 (Modulated Fuel Feedback Control of a Fuel Injection SI Engine)

  • 박경석;박진일;고상근;노승탁;이종화
    • 한국자동차공학회논문집
    • /
    • 제4권3호
    • /
    • pp.102-111
    • /
    • 1996
  • For the air-fuel ratio control in a fuel injection SI engine, the Jump-Ramp control algorithm has been widely adopted by using the on/off type oxygen sensor. But the Jump-Ramp control method has limitation on treating the frequency and amplitude of the air-fuel ratio oscillation. This study suggests another feedback control logic named modulated fuel feedback control, which has a concept of pre-tuned air-fuel ratio oscillation. In the modulation method, the oxygen sensor output is not treated as on/off signal but as analog signal for feedback. By using the modulation method, the frequency and the amplitude of air-fuel ratio oscillation can be adjustable to some extent for improving the conversion efficiency of the Three-Way Catalyst. The result shows that the performance of the modulation method is better than that Jump-Ramp control method in reducing the amplitude of the air-fuel ratio oscillation as well as in increasing the frequency of the air-fuel ratio oscillation.

  • PDF

시동 배기가스 점화기술을 이용한 촉매의 예열시간 단축 (Fast Light-Off of Catalyst using Cranking Exhaust Gas Ignition)

  • 조용석;엄인용;이윤석;김득상;김충식;천준영;최진욱
    • 한국자동차공학회논문집
    • /
    • 제9권2호
    • /
    • pp.43-49
    • /
    • 2001
  • In order to satisfy the ULEV emissions regulation, fast light-off of a catalyst is essential for reduction of HC and CO emissions during the cold start. Cranking Exhaust Gas Ignition(CEGI) method developed in this study showed that the catalyst reaches the light-off temperature in a few seconds. The CEGI stops the ignition signal for a few seconds during the cranking period, so the unburned fuel-air mixture bypasses the combustion chamber and flows through the exhaust manifold. When the unburned mixture reaches two glow plugs installed upstream of the catalyst, it burns and releases the thermal energy to heat up the catalyst, In the FTP-75 vehicle tests, the CEGI showed that the exhaust emissions reduced by 47.7% for THC and by 88.6% for CO in the cold-transient phase of the test.

  • PDF

공존 환원제가 NOx 흡장촉매의 NOx 흡$\cdot$ 탈착에 미치는 영향 (Effects for Coexistent Reductant to NOx Adsorption and Desorption of the NOx Storage Catalyst)

  • 이춘희;최병철
    • 한국자동차공학회논문집
    • /
    • 제13권5호
    • /
    • pp.181-187
    • /
    • 2005
  • The behavior of fox adsorption and desorption of the NOx storage catalyst supported on Ba additive were studied by the TPA/TPD experiments and reactivity tests. Applying the transient responses and NOx TPA/TPD test by CLD were effective methods to analyze the characteristics of the NOx storage catalyst. NOx variation of the NOx storage catalyst in the lean air/fuel conditions according to temperature was dominated by NOx adsorption and desorption rather than catalytic reduction. The presence of reductants in the lean mixture promoted the NOx desorption at the $500^{\circ}C$ higher temperature. The temperatures for maximum NOx conversion with CH4 and $C_3H_6$ as a rich spike reductant appear around $500^{\circ}C\;and\; 400^{\circ}C$ respectively.

냉시동시 촉매의 예열시간 단축에 관한 연구 (A Study for Fast Light-Off of a Catalyst During Cold Start)

  • 조용석;이윤석
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1998년도 제17회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.69-77
    • /
    • 1998
  • In order to meet the stringent emission regulations, fast light-off of a catalyst is essential to reduce the HC and CO emissions during cold start. Cranking Exhaust Gas Ignition (CEGI) method developed in this study showed that the catalyst reaches the light-off temperature in a few seconds after cold start. The CEGI system cuts off the ignition signal for a few seconds during the cranking period. so the unburned fuel-air mixture bypasses the combustion chamber and flows through the exhaust manifold. When the unburned mixture reaches two glow plugs installed upstream of the catalyst, it burns and releases the thermal energy to heat up the catalyst. Results from the FTP-75 tests showed that the exhaust emissions with the CEGI reduced by 47.7% for THC and by 88.6% for CO in the cold-transient phase of the test.

  • PDF

모형소각로의 촉매에 의한 배기가스 정화특성에 관한 연구 (A study on the pollutant reduction using catalyst in model furnace)

  • 이용후;이진석;이화신;강인구;이도형
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.154-159
    • /
    • 2005
  • In proportion to the increase of industrial development, emission troubles were concerned as global issue. For these reasons, so many researchers and associated institutes effort to reduce pollution with new technology and various devices. As a kind of these methods, we used catalysts as a after-treatment system. At first, we made equipment of model furnace. And various catalysts were equipped at exhaust duct of combustion system, and excess air ratio( ), change cell numbers, catalyst materials(Pt, Pd) were changed as experimental conditions. With these various condition, temperature, NOx, CO, HC, $CO_2$ and $O_2$ concentration were measured. As a result, NOx conversion were increased with increasing of cell number in Pd catalyst. And Pt catalyst were became 100% conversion at 200 and 300 cell. Also, Pt catalyst was better than Pd catalyst ${\alpha}$=1.5 in this condition. In addition, CO and HC concentrations were decreased${\alpha}$=1.5 with Pd catalyst.

  • PDF