• Title/Summary/Keyword: Air washing

Search Result 214, Processing Time 0.03 seconds

A Study on the Regeneration of SCR Catalyst Deactivated by Unburned Carbon Deposition (탄소침적으로 피독된 탈질 촉매의 재생에 관한 연구)

  • Moon, Seung-Hyun;Lee, Seung-Jae;Ryu, In-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.928-935
    • /
    • 2010
  • A bag filter system was partially burnt down during a trial run of waste wood incineration boiler. This brought about unburned hydrocarbon which caused a rapid deactivation of low temperature SCR catalyst set up in two stage after the bag filter. The deactivated catalyst was investigated in order to trace the origin by several characterization methods such as XRD, EDX, BET, TGA, SEM. The deactivated catalyst was regenerated by different methods such as acid washing, water washing in ultrasonication, and calcination treatment under air condition. It is found the calcination treatment under air condition at $450^{\circ}C$ for 2 hours to be the best regeneration method. The catalytic activity was measured in the form of 2 cm ${\times}$ 2 cm ${\times}$ 10 cm (catalyst weight 10 g) honeycomb type. A deNOx efficiency of the regenerated catalyst showed 100% at $180^{\circ}C$ which is the same level of fresh one.

Utilization of Domestic Small Timbers -Shrinkage and Swelling of Alkali-Treated Woods- (간벌재 및 소경재의 이용개발에 관한 연구 -알칼리 처리 목재의 수축팽윤성-)

  • 황원중;김남훈
    • Journal of Korea Foresty Energy
    • /
    • v.18 no.2
    • /
    • pp.70-77
    • /
    • 1999
  • The behaviors of alkali swelling in four major Korean woods were examined as a function of concentration cf alkali solution. Density of alkali-treated woods increased highly with increasing alkali concentration in both softwoods and hardwoods. Wood samples swelled in dimension during alkali swelling, and thereafter they shrank highly by water washing and air drying. The air-dried wood samples after alkali treatment showed almost isotropic shrinkage in tangential and radial direction.

  • PDF

Hygienic Aspects of Campylobacter Enteritis (Campylobacter장염에 의한 식품위생학적인 고찰)

  • 이용욱;홍종해
    • Journal of Food Hygiene and Safety
    • /
    • v.1 no.1
    • /
    • pp.57-66
    • /
    • 1986
  • Campylobacter jejuni has been recognized as one of the causes of human gastroenteritis. The feces of a variety of reservoir animals contain c. jejuni as commensals in the intestinal tracts, and are fundamental source of contamination. The intestinal organisms contaminate carcasses, equipment tools hands of the processing line workers and air of the processing facility. Once the contamination happens in the slaughterhouses or the meat processing facilities, it is very difficult to keep the carcasses free from the infection of c. jejuni. Various disinfectants are effective in minimizing the number of Campylobacter infections in the processing facilities by washing contaminated carcasses, tools, and hands. Direct contact with infected animals has been incriminated in transmission of infection caused by C. jejuni. Freezing, cooling with dry air and gamma irradiation are an effective way for preserving the meat and eliminating the transmission, but broad and enforced studies are needed for the practical use.

  • PDF

Risk Assessment of Indoor Pollution by BTEX Released from Groundwater (지하수내 BTEX에 의한 실내오염시 위해도 평가)

  • 유동한;이한수;김상준;양지원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.5
    • /
    • pp.373-381
    • /
    • 2002
  • Benzene, Ethyl-benzene, Toluene and Xylene (BTEX) can be released to a groundwater in case of the oil leakage from underground storage tank of a gas station. These chemicals are found to contribute to the total inhalation risk from contaminated indoor air. This study presents the assessment of a human exposure to such chemicals released from the groundwater into indoor air. At first, a 2-compartment model is developed to describe the transfer and distribution of the chemicals released from groundwater in a house through showering, washing clothes, and flushing toilets. The model is used to estimate a daily human exposure through inhalation of such BTEX for adults based on two sets of exposure scenarios. Finally, a sensitivity analysis is used to identify important parameters. The results obtained from the study would help to increase the understanding of risk assessment issues associated with the indoor pollution by BTEX released from contaminated groundwater.

A Study on Organic Solvent Exposure in Painting Operation of Automobile Manufacturing Industry (자동차 도장 작업장에서의 유기용제 폭로에 관한 연구)

  • 김영식
    • Journal of Environmental Health Sciences
    • /
    • v.20 no.4
    • /
    • pp.10-16
    • /
    • 1994
  • A Study was performed in order to measure mixed organic solvent concentrations in air of painting operations during January 5-28, 1991. The mixed organic solvent concentrations were analyzed by the gas chromatography. The results were as follows: 1. The detection of organic solvent was highest in aromatic hydrocarbon(68%), and followed by aliphatic hydrocarbon (18%), and ketone (14%). 2. The detection of organic solvent by component category was highest in the grid class solvent (79.4%), and followed by the 3rd class solvent (20.6%). 3. Number of cases exceeding TLVS of mixed solvent level in air was highest on dipping operation (44%), and followed by spray operation (40%), dry and washing operation (33%), and adhensive operation (12%).

  • PDF

A Study on the Gasification of Combustible Waste (가연성 폐기물의 가스화에 관한 연구)

  • 정준화
    • Journal of Environmental Health Sciences
    • /
    • v.16 no.2
    • /
    • pp.89-95
    • /
    • 1990
  • This study was investigated to the energy recovery by the pyrolysis of waste tyre. the pyrolysis of the waste tyre was made by using the pyrolysis chamber for the gasification and the combustion chamber for the combustion of the pyrolysis gas. In batch system, the amount of waste tyre was put 150kg in the pyrolysis chamber and the proper air flow rate for the stable production of the pyrolysis gas was 0.95Nm$^{3}$ /min. the production time of the pyrolysis gas was stable above 210minutes, and the stable production rate was above 3.8Nm$^{3}$ /min. The production temperature of pyrolysis gas was 170$^{\circ}$C and combustion temperature of pyrolysis gas was 1,000$^{\circ}$C. The combustible component of washing gas in pyrolysis gas of waste tyre was CO, CH$_{4}$, $C_{2}H_{6}$ and $C_{3}H_{8}$, and total amount was 22.7%. Heat value of condensed material was 9,804Kcal/kg. The average concentration of air pollutants between cyclone and scrubber was CO 420.4ppm, SO$_{x}$ 349.8ppm. NO$_{x}$ 68.Sppm, HCl 24.4ppm and Dust 240.0g / Nm$^{3}$, respectively.

  • PDF

Efficient Utilization of Energy in Drying Process for Rewetted Red Pepper -Hot-air-convective and Infrared-radiant Drying- (건고추의 재건조 공정에서 에너지의 효율적 이용 -열풍 대류 및 적외선 복사 건조)

  • Koh, H.K.;Cho, Y.J.;Park, J.B.;Kim, Y.H.;Kang, S.W.
    • Journal of Biosystems Engineering
    • /
    • v.14 no.4
    • /
    • pp.262-271
    • /
    • 1989
  • Red pepper is one of the most important agricultural products in Korea. Generally, raw red pepper is dried after harvest and the dried red pepper is powdered. Washing process is necessary to produce clean powder before powdering process. This study, therefore, was performed to analyze the drying characteristics of the rewetted red pepper and the energy utility during hot-air-convective and infrared-radiant drying. Drying effectiveness, De, was defined for the analysis of energy utility in this study, and its value was determined according to the energy source. Infrared-radiant drying was more favorable than convective drying according to drying effectiveness. But the temperature variation was appeared between the radiant surface and opposite surface of red pepper in infrared-radiant drying.

  • PDF

Decomposition of Hazardous Gaseous Substances by Discharge Plasma (방전 프라즈마 화학반응을 이용한 유해물질의 분해)

  • 우인성;황명환;산외번장
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.4
    • /
    • pp.79-83
    • /
    • 1996
  • In this study, in attempt to develop a new application technique of discharge plasma, we employed a kind of discharging method called SPCP ( short for Surface discharge induced Plasma Chemical Process). Applications of SPCP have been widely used for years. Compact ozonizers to deodorize household equipments like refrigerators we a part of such applications. We took advantages of the compactness and durability of the SPCP electrode to set up an experimental apparatus for decompositing vapor of aromatic hydrocarbons such as toluene, benzene and xylenes, which are major substances given off In painting or washing processes and aggravate working conditions. Results obtained from this study are summarized as follows. 1) Aromatic hydrocarbon vapors of up to 2,000ppm were almost thoroughly decomposed at the flow rate of 4ℓ/min or lower under the discharge with electric power of 400 Watts. 2) In dry air, as the decomposition progresses, tar-like substance deposits on the discharging areas, which deteriorated the decomposition rate in the end. This substance, however, was almost thoroughly removed by keeping discharge in dry air containing no solvent vapor.

  • PDF

A Study on Sustainable Laundry Behavior -Comparison between Korean and European Consumers- (국내 세탁행동의 지속가능성에 관한 연구 -유럽과의 비교를 중심으로-)

  • Wee, Jeeweon;Lee, Yoon-Jung;Jung, Hye Jung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.3
    • /
    • pp.525-545
    • /
    • 2021
  • The purpose of this study was to assess the sustainability of laundry practices among Korean households in comparison with European households. A total of 329 responses were collected through an online survey and analyzed using SPSS. Detergent dosing, use of fabric softener, prewashing, rinsing, washing programs, and washing temperatures of Korean households were not optimal for sustainability. Only 11.2% of respondents followed dosage instructions while the majority based on load size. Use of fabric enhancer, prewashing, and rinsing were frequent. Cotton 40℃ was the most frequently used program (81.5%) while eco and cold wash programs were among the least (1.5%). In terms of laundry sorting, load size, drying, and ironing, more sustainable actions were reported. Laundry was often sorted by color, machines were commonly filled, and clothes tended to be air-dried and not excessively ironed. Gender was the primary socio-demographic factor denoting sustainable habits, with males being more attentive to instructions and care labels than females. European households, however, were more sustainable in all areas except for frequent ironing, and education level and employment status were significant factors affecting sustainable practices.

Quality Characteristics during Storage of Ginseng Washed by Different Methods (세척방법에 따른 인삼의 저장 중 품질특성)

  • Lee, Hyun-Seok;Cha, Hwan-Soo;Kim, Byeong-Sam;Kwon, Ki-Hyun
    • Food Science and Preservation
    • /
    • v.16 no.3
    • /
    • pp.342-347
    • /
    • 2009
  • We sought to improve the methods for washing fresh raw ginseng. The quality of ginseng surface-washed by different methods was evaluated during storage at 10C and $20^{\circ}C$. The raw ginseng surface-washing method was a full-cone spray-type procedure using water and air. The water for decontamination had an electrolysis value of 80 ppm, also known as electrolysis water $2^{\circ}C$ water and water containing 5 ppm chlorine dioxide, were also used for decontamination. The Hunter color (${\Delta}E$) of ginseng washed with water withan electrolysis value of 80 ppm, or water with 5 ppm chlorine dioxide, was greater than that seen after other washing methods were used. The weight loss after washing with 5 ppm chlorine dioxide water was similar to that seen after washing with $2^{\circ}C$ water or 80 ppm electrolysis water. Reductions in total microorganism levels, and counts of yeasts and molds, assayed 10 days after washing with 5 ppm chlorine dioxide water were greater than seen after use of other sterilization methods. Quality maintenance on storage, at both 10C and 20C, after washing with 80 ppm electrolysis water, was better than that noted after other sterilization methods. The moisture content of washed ginseng was similar under all storage conditions tested.