• Title/Summary/Keyword: Air washing

Search Result 212, Processing Time 0.022 seconds

A Study on the Space Planing for Restaurant Kitchens to Improve Hygiene (식당 주방의 위생 향상을 위한 공간계획에 관한 연구)

  • Lee, Jong-Ran
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.11 no.1
    • /
    • pp.5-13
    • /
    • 2011
  • This research proposed the space planing methode and diagrams of restaurant kitchens to improve hygiene by analyzing the related contents collected from books and researches in interior design and HACCP (Hazard Analysis and Critical Control Point). HACCP is an effective and scientific hygiene system for food safety in order to prevent cross-contamination from food hazards. Based on the analyses, improvement of food production environments like restaurant kitchens is necessary for food hygiene. The space planing methode of restaurant kitchens to improve hygiene are followings: The circulation planing is that the direction of movement of the food, workers, waste, and dishes should be fractionated and managed for cross-contamination prevention. The space separation planing is that the spaces in the kitchen should be classified and divided into contaminated area and non-contaminated and clean area depending on the degree of cleanliness. The zoning is space arrangement with feed-back process to check the possible points of cross-contamination and correct space arrangement until the possibility of cross-contamination disappear in kitchen. However, if cross-contamination is unavoidable in some points in restaurant kitchens, hygiene facilities such as washing rooms, pass rooms, and double doors with air-shower should be located in order to remove contamination.

The Design of Low-Cost Vector-Controlled Inverter for Induction Motor Using ARM Cortex-M4 Microcontroller (ARM Cortex-M4 마이크로컨트롤러를 사용한 유도전동기의 저가형 벡터제어 인버터 설계)

  • Kim, Dong-Ki;Yoon, Duck-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.816-821
    • /
    • 2013
  • This paper proposes the design method of low-cost vector control system for induction motor using the ARM Cortex-M4 microcontroller. This MCU can be used instead of expensive DSP to control the home appliances such as refrigerator, air conditioner, washing machine and so on. This paper explains the major features of Cortex-M4 for motor control and how to realize a vector-controlled inverter using it. The developed system is applied to 3-phase induction motor of 200[W] and experimental results show good performance similar to the system using TMS320F28335 DSP.

Analysis of Benzo(a)pyrene in Red Ginseng Beverage (홍삼음료 증 벤조피렌 분석)

  • Hu, Soo-Jung;Jin, Sun-Hee;Choi, Dong-Mi
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.1
    • /
    • pp.26-30
    • /
    • 2008
  • Polycyclic Aromatic Hydrocarbons(PAHs) contamination arises from several source including processing of food(smoking, direct drying, cooking) and environmental contamination of air, water or soil. A red ginseng is produced by steaming the root followed by drying. The methodology involved extraction with n-hexane and washing with water, clean-up on Sep-Pak Florisil Cartridges and determination by HPLC/FLD. The mobile phase was a mixture of acetonitrile and water in 8:2 by the isocratic elution and the excitation wavelength of fluorescence detector was 294 nm and its emission wavelength was 404 nm. The average recovery was about 105% and the relative standard deviation was 0.5. The levels of benzopyrene in the selected red ginseng beverage samples were not detected.

A Study on Remanufacturing of Deactivated Commercial Diesel Oxidation Catalyst by CVS-75 mode in Light Duty Diesel Engine (비활성화된 상용 디젤 산화 촉매의 소형 디젤 기관에서 CVS-75 모드를 이용한 재제조에 관한 연구)

  • Lee, Chang-Hee;Park, Hea-Kyung
    • Journal of Powder Materials
    • /
    • v.18 no.6
    • /
    • pp.517-525
    • /
    • 2011
  • In this study, the used DOCs, which could remove the air pollutants such as CO and HC in the exhaust gas from diesel vehicle, were remanufactured by various conditions. Their catalytic performances and characterization were also investigated. The remanufacturing process of the deactivated DOCs includes high temperature cleaning of incineration, ultrasonic cleaning for washing with acid/base solutions to remove deactivating materials deposited to the surface of the catalysts, and active component reimpregnation for reactivating catalytic activity of them. The catalytic performance tests of the remanufactured DOCs were carried out by the diesel engine dynamo systems and chassi dynamo systems in CVS-75 mode. All prepared catalysts were characterized by the optical microscopes, SEM, EDX, porosimeter and BET to investigate correlations between catalytic reactivity and surface characteristics of them. The remanufactured DOCs at various conditions showed the improved catalytic performances reaching to 90% of fresh DOC, which is attributed to remove the deactivating materials from the surface of the used DOC through the analysis of catalytic performance test and their characterization.

Study of Recognition about Hospital Infection Management in Physical Therapists (물리치료사의 병원 감염관리에 대한 인지도 연구)

  • Song, Min-Young;Lee, Tae-Sik
    • Journal of Korean Physical Therapy Science
    • /
    • v.9 no.3
    • /
    • pp.141-150
    • /
    • 2002
  • Most of physical therapists has thought be exposed themselves to risk of hospital infection but it is reported that have been low concern about infection management. Above like this haven t done systematical education on hospital infection, also physical therapist's information management of infection disease is found very low. It is lack of driving information about disease condition of the patients. Physical therapists has thought their working room may be polluted a lots of micro-organism(%). The control situation of infection waste articles, only 53% responded that the controller has managed very intensive so we can feel to need more intensive It's reported that air culture investigation of physical therapy room has never initiated. To wash the hand, before, after treatment of the patients of physical therapist, is very low frequency. And 73% have responded that the time to wash the hand stays 15-45 second. It is examined that 70% physical therapy room is equipped with washing system, a response of 58% disinfects physical therapy room 1-2times per one month. 36% responded disinfection of treatment modality have done everyday, 25% responded have never done. The location physical therapy room is above one floor - 65%. A response of 57% is ventilation system sufficiency, it is considered that physical therapists needs more efforts on management of hospital infection.

  • PDF

Fundamental Design of Cyclone Collector for Oil Mist (오일미스트용 사이클론 집진기에 관한 기초 설계 -오일미스트 및 슬러지 입자 융합연구-)

  • Jang, Sung-Cheol;Ahn, Hwi-Woong;Lee, Chan-Kyu
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.2
    • /
    • pp.223-227
    • /
    • 2013
  • Dust collecting performance of cyclone collector for oil mist was alalyzed in the study. The purposes of using cutting fluid during cutting have been colling, lubricating, chip washing and anti-corroding. However, the present manufactaring industry restricts the use of cutting fluid because cutting fluid confains poisonous substances which are harmful to the human body. Also, the optimum design oil-mist collector. The new oil mist collector was designed. In the near future, this device must be tested in the real machining center and CNC machine. Cutting using oil-mist showed better cutting characteristics than dry, air and fluid cutting with respect to by cutting force, tool wear and surface roughness. The model(A, B Type cyclone) of the set of fixture and alveolus are made by using a CAE software. Finally, we have obtained a model A Type solution by using orthogonal array. Therefore, it could be confirmed that as the model-A was increased and model-B was decreased, cut diameter was decreased.

A Statistical Analysis of Recycling Cost for Waste Home Appliances

  • Esher Hsu;Kuo, Chen-Ming
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.59-64
    • /
    • 2001
  • On July 5, 1997, environmental Protection Administration of Taiwan publicized the recycling regulation of waste home appliances that include four items, namely, television, refrigerator, washing machine, and air conditioner. It is believed that this regulation pioneers the law enforcement of waste home appliances in the world. To comply with tile policy, several contemporary waste disposal plants specialized in waste home appliances were established according to a follow-up technical specification oil the waste treatment facilities and methodology. Therefore, the traditional dismantling facilities were substituted and waste collection routes were altered as well accordingly. This study investigates the collection and recycling costs of waste home appliances in accordance with these newly established routes and facilities, respectively. Cost survey was conducted among collectors and recycling plants of waste home appliances; consequently, tire collection and recycling costs were analyzed, correspondingly. Results show that the recycling costs of waste home appliances were much higher than that of other waste items. Since the market share of recycled materials is lacking, these waste recycling plants of home appliances can only survive under the subsidy of EPA in Taiwan. Due to some arduous problems, the subsidiary system has already caused serious financial unbalance for a foundation under EPA of Taiwan, which associated with waste recycling in Taiwan.

  • PDF

Electromagnetic Noise Reduction of Reciprocating Compressor using Random PWM (랜덤 PWM을 이용한 왕복동식 압축기의 전자기소음 저감)

  • 조관열;양순배;김학원
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.200-207
    • /
    • 2000
  • Recently, it is increased to apply the inverter system to household electrical appliances, especially in the air c conditioners, refrigerators and washing machines, to reduce the power consumption and the acoustic noise by t the low speed operation, and to make their functions more comfortable for human beings. For the inverter s systems, however, it is highly required to reduce the undesirable electromagnetic noise and psychoacoustic n noise generated by PWM for variable speed operation. In this paper, the electromagnetic noise for the d detenninistic PWM and random PWM for the reciprocating compressors driven by the brusWess dc motor was a analyzed. It was also verified through the experiment that the elt'Ct$\tau$omagnetic noise was reduced and the s sound quality was improved by applying the random PWM.

  • PDF

Reuse of Weaving Wastewater with BAF Process (BAF 공정을 이용한 제직폐수의 재이용)

  • Jung, Yong-Jun;Bae, Jong-Hong;Kwon, Koo-Ho;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.664-669
    • /
    • 2004
  • An upflow BAF(Biological Aerated Filter) equipped with an expanded clay media was applied to reuse weaving wastewater of water jet loom. The performance of lab-scale biofilter was investigated by the adjustment of EBCTs(Empty Bed Contact Time) and the packing ratio of media, which were changed 1.1 to 3.7hr and 38 to 63%, respectively. In most conditions except 1.1hr of EBCT, BOD, CODcr, SS and Turbidity of the effluent were 1~4mg/L, 7~16mg/L, 1~5mg/L and 5~14NTU, where their removal efficiencies were 76~95%, 82~93%, 63~94% and 59~81%, respectively. From the observation of SEM(Scanning Electron Microscope) photographs of porous clay media, it was revealed that this media provided good performance of retaining microbes effectively. In addition, $0.44~0.49kgVSS/kgBOD_{rem}$. of low sludge reduction was expected. The most efficient back washing cycle and procedure were once per 4 to 9 days and air including collapse-pulsing method, respectively. Therefore, this system can be of use as an weaving wastewater treatment for reuse.

Study on an Intermediate Compound Preparation for a HTGR Nuclear Fuel (고온가스로용 핵연료 중간화합물 제조에 대한 연구)

  • Kim, Yeon-Ku;Suhr, Dong-Soo;Jeong, Kyung-Chai;Oh, Seung-Chul;Cho, Moon-Sung
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.11
    • /
    • pp.725-733
    • /
    • 2008
  • In this study the preparation method of the spherical ADU droplets, intermediate compound of a HTGR nuclear fuel, was detailed-reviewed and then, the characteristics on an ageing and a washing steps among the wet process and the thermal treatment process on the died-ADU${\rightarrow}UO_3$ conversion with the high temperature furnaces were studied. The key parameters for spherical droplets forming are a precise control of feed rate and a suitable viscosity value selection of a broth solution. Also, a harmony of vibrating frequency and amplitude of a vibration dropping system are important factor. In our case, an uranium concentration is $0.5{\sim}0.7mol/l$, viscosity is $50{\sim}80$ centi-Poise, vibration frequency is about 100Hz. In thermal treatment for no crack spherical $UO_3$ particle, the heating rate in the calcination must be operated below $2^{\circ}C$/min, in air atmosphere.