• 제목/요약/키워드: Air volume

검색결과 2,288건 처리시간 0.027초

Influence of Curing-Form Material on the Chloride Penetration of Off-Shore Concrete

  • Park, Sangjun;Choi, Yeol
    • International Journal of Concrete Structures and Materials
    • /
    • 제6권4호
    • /
    • pp.251-256
    • /
    • 2012
  • This paper presents an experimental study on the pore and penetration of chloride in seashore concrete depending on types of curing forms. Three types of concretes (Plain concrete, MSF concrete and FA concrete) with four different form types (wood, coating wood, steel and polypropylene film) were examined. The test results show that the air volume in concrete was relatively higher with steel and polypropylene forms than others, and wood form shows the least air volume. The penetration of chloride depending on type of form is showed a wide variability, that is, the values on plain concrete, MSF concrete and FA concrete are 115.2, 125.5 and 121.6 %, respectively. Based on the present study, concrete should be considered the conditions of curing form-type for durable concrete.

HDD의 DISK 진동감쇠 및 PES 저감을 위한 Disk Damper의 설계와 그 해석 (Reduction of Disk Vibration and PES Using a Disk Damper)

  • 권정민;강성우;한윤식;황태연;구자춘
    • 한국소음진동공학회논문집
    • /
    • 제14권3호
    • /
    • pp.201-207
    • /
    • 2004
  • High speed rotating airflow inside a HDD chamber causes sub-micron scale disk vibration that could generate significant TMR problems in most of current HDD products. Many publications are presented for the reduction of airflow excitation. One of the most effective methods widely adopted in high-end HDD products is SqueezeAir Bearing Plate (SABP). However, because of its tight assembly clearance between the damper and disk, this method could not be easily implemented in volume production. This article presents a disk damper design that is modified to be feasible for volume production by virtue of a new airflow modeling method.

위상동기루프 방식을 이용한 고빈도 JET환기장치의 설계에 관한 연구 (A Study on the Design of High-Frequency Jet Ventilator Using PLL system)

  • 이준하;정재천
    • Journal of Yeungnam Medical Science
    • /
    • 제6권2호
    • /
    • pp.63-70
    • /
    • 1989
  • This paper describes to design and to examine the mechanical characteristics of high frequency jet ventilator. The device consists of Phase lock loop(PLL) system, solenoid valve driving control part and Air regulating system. This study is carried out by changing several factors such as endotracheal tube(E.T. tube)diameter, injector cannula diameter, 1%, and frequency(breaths/mim.) having direct effects on the gas exchange as well as parameters of the entrained gas by venturi effects, so as to measure the tidal volume and minute volume. This system characteristics were as follows : 1) Frequency : 6-594bpm 2) Inspiration time : 1-99% 3) Variance of input air pressure : 1-30PSI.

  • PDF

기포운동에 따른 2상유동 특성에 관한 연구 (A Study on the Characteristics of Two-Phase Flow by Driven Bubbles)

  • 서동표;오율권
    • 설비공학논문집
    • /
    • 제15권4호
    • /
    • pp.268-273
    • /
    • 2003
  • In the present study, the characteristics of upward bubble flow were experimentally investigated in a liquid bath. An electro-conductivity probe was used to measure local volume fraction and bubble frequency. Since the gas is concentrated at the near nozzle, the flow parameters are high near the nozzle. In general their axial and radial values tended to decrease with increasing distance. For visualization of flow characteristics, a Particle Image Velocimetry (P.I..V) and a thermo-vision camera were used in the present study. The experimental results show that heat transfer from bubble surface to water is largely completed within z=10mm from the nozzle, and then the temperature of bubble surface reaches that of water rapidly. Due to the centrifugal force, the flow was more developed near the wall than at bubble-water plume. Vortex flow in the bottom region was relatively weaker than that in the upper region.

혼합냉매를 사용한 열펌프의 성능해석 (II) (Performance Analysis of a Heat Pump Using Refrigerant Mixtures (II))

  • 김민수;김동섭;원성필;노승탁
    • 설비공학논문집
    • /
    • 제2권3호
    • /
    • pp.218-225
    • /
    • 1990
  • Studies on the performance of a heat pump using non-azeotropic refrigerant mixtures are done. In order to estimate the thermodynamic properties for the selected non-azeotropic refrigerant mixtures including R22/R152a, R22/R142b, R22/R114 and R13B1/R152a, Peng-Robinson equation of state is adopted. The pressure-enthalpy diagram and the temperature-entropy diagram are plotted for each refrigerant mixture. Considerations on the capacity modulation for the heat pump system using refrigerant mixtures are taken into. Results show that when the heating load varies, the possibility for the capacity modulation is found in the heat pump system using a compressor with constant volume flow rate. Under a constant heating capacity condition in the heat pump system, the coefficient of performance increases when the refrigerant mixtures are used. The volume flow rate decreases as the mass fraction of lower boiler increases in this case.

  • PDF

원형 CAV 댐퍼의 개발에 관한 연구 (A Study on the Development of a Circular CAV Damper)

  • 권영필
    • 설비공학논문집
    • /
    • 제25권11호
    • /
    • pp.612-616
    • /
    • 2013
  • A circular CAV damper has been developed, based on the investigation of the pressure loss, and the flow-resisting moment by the damper blade. When a torsional spring is attached to the damper axle, and the setting angle is adjusted to around $82^{\circ}$, the volume rate across the damper is almost independent of the static pressure. Such a CAV characteristic appears at an opening angle between $40^{\circ}$ and $60^{\circ}$, where the normalized moment decreases linearly with the angle. In addition, by adjusting the setting angle, the volume rate can be controlled to within 10% error, regardless of the pressure loss.

Computation of Water and Air Flow with Submerged Hydrofoil by Interface Capturing Method

  • Kwag, Seung-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • 제14권7호
    • /
    • pp.789-795
    • /
    • 2000
  • Free-surface flows with an arbitrary deformation, induced by a submerged hydrofoil, are simulated numerically, considering two-fluid flows of both water and air. The computation is performed by a finite volume method using unstructured meshes and an interface capturing scheme to determine the shape of the free surface. The method uses control volumes with an arbitrary number of faces and allows cell wise local mesh refinement. The integration in space is of second order, based on midpoint rule integration and linear interpolation. The method is fully implicit and uses quadratic interpolation in time through three time levels. The linear equations are solved by conjugate gradient type solvers, and the non-linearity of equations is accounted for through Picard iterations. The solution method is of pressure-correction type and solves sequentially the linearized momentum equations, the continuity equation, the conservation equation of one species, and the equations for two turbulence quantities. Finally, a comparison is quantitatively made at the same speed between the computation and experiment in which the grid sensitivity is numerically checked.

  • PDF

블라우스내에 형성되는공기층이 의복내환기에 미치는 영향 연구 (The Effects of Blouse Types on Ventilation Clothing Microclimate)

  • 박우미;최철호
    • 한국의류학회지
    • /
    • 제16권2호
    • /
    • pp.169-180
    • /
    • 1992
  • The purpose of this study is to investigate the effects of type of clothing microclimate and exercise condition on ventilation. The experimental system employed a trace gas technique of the previous research. Clothing microclimate volume measurement was based on the substitution water technique for inter-clothing air volume. The experimental variables were tested at four levels of clothing microclimate spacing, microclimate shape of the previous research and two levels of exercise conditions. 2, 4, 6 cm ease were added to B/2+4 of basic blouse pattern for the microclimate spacing variable. Each combination of three variables were tested in triplicate. Analysis of variance of experimental variables on vetilation, such as oxygen exchange rate, half time of first order model was conducted. Oxygen exchange rate and half time of first order model are affected by the shape of microclimate air and exercise condition.

  • PDF

자탈형(自脱型) 콤바인 환원장치(還元裝置)의 환원물(還元物) 유동현상(流動現象)과 환원성능(還元性能) 개선(改善)에 관한 연구(硏究)(I) -환원율(還元率)과 조성비(組成比)- (Tailings Behavior and Performance of the Tailings Return Unit of the Head-feed Combine(I) -Ratio and Compositions of Tailings-)

  • 조영길;정창주;최규홍;박판규
    • Journal of Biosystems Engineering
    • /
    • 제16권1호
    • /
    • pp.18-26
    • /
    • 1991
  • This study was undertaken to investigate the ratio and compositions of tailings of the tailings return unit in the commercially available head-feed combines. The ratio of the returned tailings to the sum of the threshed grain and the returned tailings was 2.3~7.2% for various varieties of rice and operational conditions of combines tested and increased as the feeding rate and the cleaning air volume increased. The analysis of the returned tailings showed that the composition of rubbish and short straw was decreased as the feeding rate and the cleaning air volume increased.

  • PDF

A Third-order Simulation Model of a Vuilleumier Cycle Heat Pump

  • Kang, Young-Goo;Jeong, Eun-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.80-92
    • /
    • 1998
  • A third-order simulation model of a Vuilleumier{VM) heat pump has been developed. This model takes into account the major losses such as the heat conduction losses through regenerators and displacers, the pumping losses and the wall-to-gas heat transfer losses in active volumes, in addition to the heat exchanger and regenerator losses. The working volume was divided into 12 control volumes and the conservation equations of mass and energy were applied to each control volume. Pressure drops were considered in regenerators only. Thermodynamic behavior of the working gas in a VM heat pump was investigated and effects of the major losses and operating conditions on the performance of a VM heat pump were shown.

  • PDF