• Title/Summary/Keyword: Air volume

Search Result 2,291, Processing Time 0.032 seconds

Prediction of GHP Performance Using Cycle Analysis (사이클 해석을 통한 GHP 성능 예측)

  • Cha, Woo Ho;Choi, Song;Chung, Baik Young;Kim, Byung Soon;Jeon, Si Moon
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.1
    • /
    • pp.15-21
    • /
    • 2015
  • In this paper a prediction method of GHP performance is proposed for increasing design accuracy. Two compressors with different capacity and 2311cc gas engine are used for prediction and the target capacity of GHP is 25HP. For predicting GHP performance at first the operation points are randomly selected and then as compared with compressor performance date and heat exchanger characteristic, more accurate operating points are decided through recursive calculation. Lastly engine performance date is used for calculating gas consumption volume. Predicting heating mode performance of GHP, evaporator is separated to the two section of absorbing heat in outdoor air and in engine. From the experimental results, it was found that the simulation model is good for the predicting GHP efficiency and the difference of predicted and measured efficiency is less than 5%.

Study on the Heat Transfer Characteristic of Metallic Foam (발포금속의 열전달 특성에 관한 실험적 연구)

  • Kim, Pil-Hwan;Jin, Mei-Hua;Kim, Young-Jin;Jeong, Hyo-Min;Chung, Han-Shik
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.618-623
    • /
    • 2008
  • To enhancement heat transfer performance, the metallic foam as heat exchanger was studied rapidly. This was attributed to its high surface area to volume ratio as well as intensive flow mixing by tortuous flow passages. So the experimental study about the heat transfer characteristic of metallic foam is presented in this paper. The material in this experiment was used as FeCrAl which has density of 10 ppi, 20 ppi and 30 ppi respectively. And the results show the heat transfer is rise with permeability Reynolds number increase and the pressure drop metallic foam was increased with the ppi increase.

  • PDF

A Study on High Efficiency of Phase Grating (은염에 형성된 위상형 회절격자의 고효율에 관한 연구)

  • Kim, Nam;Gil, Sang-Keun;Park, Han-Kyu
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.3
    • /
    • pp.145-152
    • /
    • 1989
  • Volume phase diffraction grating is formed in 5${mu}m$ Agfa 8E75 photographic emulsion film using He-Ne laser. It is dependent on the chemical processing rather than materials themselves that high diffraction efficiency can obtained in silver halide emulsions. With potassium dichromate bleach and alcohol drying, overall efficiency of 71% (81% after allowing for reflection at the two surfaces) has been achieved at an exposure of 180${mu}J/cm^2.$ Dichromate cross-linkage and air void by rapid dehydration increase refractive index modulation depth. The grating is swollen, which is newly identified by Scanning Electronic Microscope(SEM) photography, and it causes on-Bragg at larger angle than the recording angle. It is pointed out that controlling the emulsion thickness has an important role as a potential source for high diffraction efficiency.

  • PDF

A Study on the Classification of Nursing Diagnoses by Student Nurses (간호학생이 내린 간호진단 분석에 관한 연구)

  • Min, Soon
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.3
    • /
    • pp.457-471
    • /
    • 1995
  • This research was done to promote improvement of practical application of nursing diagnoses and to improve the quality of nursing. The subjects of this research were 156 second year students of C junior nursing college who were giving adult patient care. The nursing diagnoses of 312 reports were analyzed using NANDA. In these case reports only nursing diagnoses were considered, of which there were a total of 982. In the data analysis the 9H of the nursing students' nursing diagnoses matched with 105 NANDA nursing diagnoses, Of these, the most frequent diagnoses were pain(165, 17.48%), anxiety(101, 10.70%), alteration in nutrition(83, 8.79%) , sleep disturbance (67, 7.10%), in activity intolerance (67, 7.10%), ineffective breathing pattern(51,5.40%). The etiology for the students' nursing diagnoses were compared with NANDA's nursing diagnoses by frequency. The most frequent etiology for the nursing diagnoses of pain was a biological etiology(50, 31%), for anxiety, situation crisis(58, 57.43%), for alteration in nutrition, indigesion(23, 27.71%), for sleep disturbance, external etiology(25, 37.32%), for activity intolerance, immobile position(22, 32.84%), for ineffective breathing pattern, pain(35, 68.63%), and for ,impaired physical mobility, pain(31, 65.96%). The most frequent etiology for constipation was inadquate digestion of water and cellulose (16, 34.78%), for fluid volume felicity, loss of body fluid (21, 52.50%), for impaired skin integrity, external etilogy(16, 43.24%), for impaired physical mobility, pain(22, 62.86%) , for knowledge deficits, cognition disturbance(9, 27.27%), for ineffective air way clearance, secretion obstruction(14, 48.27%) , for impaired gas exchange, loss of transport ability of blood oxygen(9, 37.50%) , and for powerlessness, therapy environment (5, 22.73%). The number of nursing diagnoses by pattern was exchange(16), moving(6), feeling(4), choosing(4), relating(3), communication(1), perceiving(1), knowing(1), valuing(1).

  • PDF

THE STUDY OF PATIENT EXPOSURE AND PROTECTION FROM DENTAL RADIOGRAPHY (치과 X선 촬영에 있어서 환자에 대한 피폭과 방어에 관한 연구)

  • Park T. W.
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.9 no.1
    • /
    • pp.25-31
    • /
    • 1979
  • The utilization of x-ray for diagnosis and examination is increasing by about 5-15% every year, therefore, it would be mandatory to protect the patients from exposures and so, studies in this field are performed even now. In dental field, the area of irradiation is limited any to the head and neck area, but the irradiated angle is varied following the objected tooth, so the adjacent structures lens and thyroid gland would be fragile to radiation. And the scattered radiation is one of the complicated problems in the protection because of specificity of dental x-ray and its object structures. The author, by using TLD (Thermo luminescent Dosimeter; Teledyne Isotopes-Model 7300, Element; TLD 200(CaF₂:Dy) and Capintec(Capintec Model 192, PM-30 Diagnostic chamber 28㎖ active volume), tried a measurement of air dose distribution of the scattered radiation and the irradiated dose of lens and thyroid gland under the condition of taking the film on the left maxillary molar. The results were as follows: 1. The half value layer of adapted dental x-ray machine was measured, and is 1.44㎜ Al. 2. The time of irradiation on the left maxillary molar in the Alderson Rando Phantom, the measured doses of left and right lens, and thyroid gland were 8,9mR, 1,2mR and 2,8mR. Under the same conditions, the scattered radiation at the distance of 1 meter from the phantom were 84 μR at the front side, 11μR at the back side, 18μR at the right side and 72μR at the left side. 3. Under the same conditions, the dose showed higher value by about 5% in the presence of object(phantom) than in the case of absence.

  • PDF

A Study on the Ferromagnetic Resonance of FeNb Thin Films (FeNb 박막의 강자성 공명 연구)

  • Lim, Woo-Young;Baek, Jong-Sung;Lee, Soo-Hyung
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.4
    • /
    • pp.120-126
    • /
    • 2004
  • In order to understand the temperature dependence of magnetic properties of $F_{84}Nb_{16}$(wt.%) thin films, ferromagnetic resonance experiments have been carried out. The ferromagnetic resonance spectra for all temperatures consist of several volume modes and one (or two) surface modes. It is suggested that both surface of the film have a perpendicular hard axis to the film plane (negative surface magnetic anisotropy). Saturation magnetization coincides with the Block's T$\^$2/3/ and spectroscopic splitting factor is almost constant in the temperature range from 113 K to 293 K. The surface magnetic anisotropy constant K$\_$s2/ of the film-substrate interface increased with decreasing temperature in the temperature range from 233 K to 293 K. The surface magnetic anisotropy constant K$\_$s1/ of the air-substrate interface decreased from -0.322 erg/$\textrm{cm}^2$ to -0.394 erg/$\textrm{cm}^2$ as the temperature decreased to 253 K and was almost constant below 233 K.233 K.

Effect of Reverse Transformation Treatment on the Formation of Retained Austenite and Mechanical Properties of C-Mn TRIP Steels (C-Mn계 TRIP강의 잔류오스테나이트 생성과 기계적 성질에 미치는 역변태처리의 영향)

  • You J. S;Hong H;Lee O. Y;Jin K. G;Kim S. J
    • Korean Journal of Materials Research
    • /
    • v.14 no.2
    • /
    • pp.126-132
    • /
    • 2004
  • The high strength steel sheets has been widely used as the automobile parts to reduce the weight of a vehicle. The aim of this research is to develop the TRIP aided high strength low carbon steels using reverse transformation process. The 0.15C-4Mn and 0.15C-6.5Mn steel sheets were reversely transformed by slow heating to intercritical temperature region and air cooling to room temperature. The stability of retained austenite depends on the enrichment of carbon and manganese by diffusion during the reverse transformation. The amount of retained austenite formed after reversely transformed at $645^{\circ}C$ for 12 hrs. was about 46vol.% in hot rolled 0.lC-6.5Mn steel. The change in volume fraction of retained austenite with a holding temperature was consistent with the changes in elongation and the strength-ductility combination. The tendency of tensile strength to increase with increasing the holding temperature was due to the decrease of retained austenite after cooling from the higher temperature of $670 ^{\circ}C$. The maximum strength-ductility combination was about 4,250 kg/$\textrm{mm}^2$ㆍ% when the hot rolled 0.lC-6.5Mn steel was reversely transformed at $645^{\circ}C$ for 12 hrs.

The Stress -Strain Behavior of Sand in Torsion Shear Tests (비틀림전단시험에 의한 모래의 응력 -변형률 거동)

  • 남정만;홍원표
    • Geotechnical Engineering
    • /
    • v.9 no.4
    • /
    • pp.65-82
    • /
    • 1993
  • A series of torsion shear tests were performed to study the drained stress -strain behavior of medium dense Santa Monica Beach sand under various stress paths. The torque was applied to both clockwise and counterclockwise directions at the end of hollow cylinder specimen. Two clip gages had been previously used to measure the changes in wall thickness and diameter of the specimen. In this study, however, the lateral strain was determined by measuring volume changes in specimen. Specimens were prepared by the air pluviation method and gaseous carbon deozide( CO2) was used to measure precisely volumetric strain in specimen. The drained stress -strain behavior of cohesionless Boils during rotation of principal stress directions was analysed based on the results of torsion shear tests. The coupling of mal stress were applied. It was also found from the test results that the atrial strain at failure decreased with increasing value.

  • PDF

Effect Analysis of Mix Designing Factors on Workability and Rheological Parameters of Self-Compacting Concrete (배합요인이 자기충전 콘크리트의 워커빌리티 및 레올로지 파라미터에 미치는 영향 분석)

  • Yoon, Seob;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.3
    • /
    • pp.235-242
    • /
    • 2018
  • The objective of the paper is to investigate the effect of mix designing factors on the workability and rheological parameters of self compacting concrete in order to facilitate the difficulties of quality control of high sensitivity of SCC. Mix proportions of SCC were prepared with various conditions of coarse, and fine aggregate, and unit water content, and the SCC mixtures were tested on workability, rheological properties to provide basic data for quantitative evaluation. Test results indicated that the yield stress of SCC decreased with increasing the coarse aggregate volume ratio, and increased with increasing the amount of VMA. However, unit water content, fine aggregate type, and air content didn't affect the yield stress value. The plastic viscosity according to the mixing factors showed a similar tendency to the yield stress. In addition, there was no correlation between yield stress and workability (flow, T50, V-lot). However, there was closely correlation among plastic viscosity and T50 and V-lot. Especially, T50 and V-lot time decreased with decreasing plastic viscosity.

Decay Rate of the Nitrogen Dioxide in Indoor Residence Using Mass Balance Model (물질수지 모델을 이용한 주택 실내의 이산화질소 감소율)

  • 유승진;배현주;양원호;정문호
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.2
    • /
    • pp.145-152
    • /
    • 2001
  • The purpose of this study was to determine nitrogen dioxide(NO$_2$) decay rate by reaction between NO$_2$ and interior materials in Korean residence. The results of this research could be helpful to choose the interior construction materials and to study on reduction of indoor air pollutants. The results of this research are as follows; For 30 residences in Seoul and Incheon from October 2000 to march 2001, the mean of infiltration rate was 0.70$\pm$0.44 ACH, and single-detached houses (7 houses) and apartments (19 houses) were 0.97$\pm$0.55 ACH and 0.61$\pm$0.34 ACH, respectively. The $CO_2$ decay followed approximately first-order process ($R^2$=0.97$\pm$0.02). There existed a statistic significance in filtration rate between houses built in 1980’s and built in 1990’s by t-test (p<0.02). Mean of NO$_2$ decay rates in 26 residence3s except 4 residences was 0.94$\pm$0.49hr$^{-1}$ , and also 0.86$\pm$0.49hr$^{-1}$ , 0.97$\pm$0.50hr$^{-1}$ in single-detached houses and apartments, respectively. Mean NO$_2$ decay rates in houses built in 1980’s were 0.78$\pm$0.37hr$^{-1}$ , 1.33$\pm$1.03hr$^{-1}$ , respectively. Nothing were showed statistical significance among indoor temperature, indoor humidity, and NO$_2$ decay rate. However, NO$_2$ decay rates had a tendency to increase by increase of temperature and humidity. Average volume/surface of participated houses was 0.55$\pm$0.07m and mean NO$_2$ deposition velocity was calculated as 1.46$\pm$0.59msec$^{-1}$ .

  • PDF