• Title/Summary/Keyword: Air ventilation

Search Result 1,575, Processing Time 0.042 seconds

Evaluation of Odor Dispersion from Livestock Building through Field Experiment (현장실험을 통한 축산시설로부터 배출되는 축산악취의 확산 평가)

  • Yeo, Uk-Hyeon;Lee, In-Bok;Ha, Tae-Hwan;Decano, Cristina;Kim, Rack-Woo;Lee, Sang-Yeon;Kim, Jun-Gyu;Choi, Young-Bae;Park, You-Me
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.6
    • /
    • pp.21-30
    • /
    • 2019
  • Livestock odor is comprised of mixed type of odorous compounds. Among these, ammonia ($NH_3$) and hydrogen sulfide ($H_2S$) are the two known major odor causing substances. Because high odor concentration reduces productivity of livestock and causes damage to the surrounding communities, quantitative analysis is needed to manage the odor inside and outside the livestock facilities. It is also necessary to evaluate odor dispersion according to the distance between the receptors taking into account the influence of odor source and weather condition. Therefore, in this study, we tried to evaluate the internal environment and odor dispersion from experimental pig house considering weather conditions. An experimental farm was specifically selected to eliminate the interference of odors generated by adjacent farms. $NH_3$ and complex odor were quantitatively analyzed using a gas detector and air dilution sensory method. The concentration of $NH_3$ and complex odor in pig house showed a distinct concentration difference according to the cleaning and ventilation conditions. $NH_3$ concentration and complex odor was lower than emission standard in the pig house and at the site boundary. The average $NH_3$ concentration (P1~P3) and the $NH_3$ concentration at the site boundary (S1) were strongly correlated with R=0.77. While the correlation for complex odor inside and at the site boundary had R=0.52. The correlation coefficient between $NH_3$ and the complex odor was 0.80.

A Review on Potential Effects of Installation and Operation of Ground Source Heat Pumps on Soil and Groundwater Environment (지열히트펌프시스템의 설치 및 운영이 토양.지하수에 미치는 영향에 대한 고찰)

  • Jo, Yun-Ju;Lee, Jin-Yong;Lim, Soo-Young;Hong, Gyeong-Pyo
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.3
    • /
    • pp.22-31
    • /
    • 2009
  • Recently use of renewable energies such as geothermal energy for space heating and cooling is increasing in Korea due to energy crisis and global warming. Ground source heat pump (GSHP) is known as one of the most environment-friendly HVAC (heating, ventilation and air-conditioning) systems in the world. However, some potential effects caused installation and operation of the GSHP systems on soil and groundwater environment are reported. The potential effects are closely related with inappropriate installation, operation and closure of the GSHP systems. In this paper, possible effects of the GSHPs on soil and groundwater environments are reviewed.

Occurrence and distribution of indoor volatile organic compounds in residential spaces by sampling methods (시료채취 방식에 따른 주거 공간 내 휘발성유기화합물 발생 특성 평가)

  • Lee, Suyeon;Kim, Daekeun
    • Journal of odor and indoor environment
    • /
    • v.17 no.4
    • /
    • pp.362-371
    • /
    • 2018
  • Indoor Volatile organic compounds (VOCs) are classified as known or possible toxicants and odorants. This study characterized VOC levels in 11 homes in an area in the capital of Seoul by using two different methods of VOCs sampling, which are the active sampling using a thermal sorption tube and the passive sampling using a diffusion sampler. When using the active sampling method, the total target VOC concentration ranged from 41.7 to $420.7{\mu}g/m^3$ (mean $230.4{\mu}g/m^3$ ; median $221.8{\mu}g/m^3$) during winter and 21.3 to $1,431.9{\mu}g/m^3$ (mean $340.1{\mu}g/m^3$; median $175.4{\mu}g/m^3$) during summer. When using the passive method, 29.6 to $257.5{\mu}g/m^3$ (mean $81.8{\mu}g/m^3$; median $49.4{\mu}g/m^3$) during winter and 1.2 to $5,131.1{\mu}g/m^3$ (mean $1,758.8{\mu}g/m^3$; median $1,375.1{\mu}g/m^3$) during summer. Forty-nine VOCs were quantified and toluene showed the highest concentration regardless of the season and the sampling method studied. The distribution of VOCs was relatively varied by using the active method. However, it showed a low correlation with indoor environmental factors such as room temperature, humidity and ventilation time. The correlation between indoor environmental factors and VOCs were relatively high in the passive method. In particular, these characteristics were confirmed by principal component analysis.

Indoor distribution characteristics of airborne bacteria in pig buildings as influenced by season and housing type

  • Kim, Ki Youn;Ko, Han Jong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.5
    • /
    • pp.742-747
    • /
    • 2019
  • Objective: A concentration of airborne bacteria generated from swine houses is recognized to be relatively higher than other work places and it is essential to optimally manage it to prevent farmers' respiratory diseases. This study was conducted to assess the distribution characteristics of airborne bacteria in swine houses located at South Korea. Methods: A total 27 pig buildings of the enclosed type operated with mechanical ventilation system by a side wall fan and deep-pit manure system with slats were surveyed. Air samples were collected at 1.0 m above the middle floor in pig housing room. A six-stage viable particulate cascade impactor was used to identify the distribution of the sizes of particles in diameter. Results: Seasonal mean levels of airborne bacteria in the housing rooms of gestation/farrowing pigs, nursery pigs and growing/fattening pigs were 3,428(${\pm}1,244$) colony forming unit $(cfu)/m^3$, $8,325({\pm}3,209)cfu/m$, and $13,254({\pm}6,108)cfu/m^3$ for spring; $9,824({\pm}2,157)cfu/m^3$, $18,254({\pm}5,166)cfu/m^3$, and $24,088({\pm}9,274)cfu/m^3$ for summer; $1,707({\pm}957)cfu/m^3$, $4,258({\pm}1,438)cfu/m^3$, and $8,254({\pm}2,416)cfu/m^3$ for autumn; and $2,322({\pm}1,352)cfu/m^3$, $6,124({\pm}1,527)cfu/m^3$ and $12,470({\pm}4,869)cfu/m^3$ for winter, respectively. Conclusion: Concentrations of airborne bacteria according to pig housing type were highest in growing/fattening housing room followed by nursery housing room and gestation/farrowing housing room. In terms of seasonal aspect, the pig building showed the highest levels of airborne bacteria in summer followed by spring, winter and autumn. The respirable airborne bacteria which are ranged between 0.6 and $4.7{\mu}m$ accounted for approximately 60% compared to total airborne bacteria regardless of pig housing type.

Machine Learning Approach for Pattern Analysis of Energy Consumption in Factory (머신러닝 기법을 활용한 공장 에너지 사용량 데이터 분석)

  • Sung, Jong Hoon;Cho, Yeong Sik
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.8 no.4
    • /
    • pp.87-92
    • /
    • 2019
  • This paper describes the pattern analysis for data of the factory energy consumption by using machine learning method. While usual statistical methods or approaches require specific equations to represent the physical characteristics of the plant, machine learning based approach uses historical data and calculate the result effectively. Although rule-based approach calculates energy usage with the physical equations, it is hard to identify the exact equations that represent the factory's characteristics and hidden variables affecting the results. Whereas the machine learning approach is relatively useful to find the relations quickly between the data. The factory has several components directly affecting to the electricity consumption which are machines, light, computers and indoor systems like HVAC (heating, ventilation and air conditioning). The energy loads from those components are generated in real-time and these data can be shown in time-series. The various sensors were installed in the factory to construct the database by collecting the energy usage data from the components. After preliminary statistical analysis for data mining, time-series clustering techniques are applied to extract the energy load pattern. This research can attributes to develop Factory Energy Management System (FEMS).

Development of high-efficiency heating system using humidifying particles (가습 입자를 활용한 고효율 난방 시스템 개발)

  • Lee, Jeong-Won;Hong, Kyung-Bo
    • Design & Manufacturing
    • /
    • v.14 no.4
    • /
    • pp.17-24
    • /
    • 2020
  • Products for heating indoors in low temperature and dry winter are largely divided into products using fossil fuels and products using electricity. The fossil fuels can warm the entire space by convection, but there is a high risk of fire and the frequent ventilation due to the increase in carbon monoxide and carbon dioxide. Heaters using electricity are mainly used because they are convenient to use and are cheap. However, these products can not efficiently warm the air because they use radiation energy. In other words, only the front part exposed to the heater is warm, and the rear part has no heating effect at all. Also, because it emits a large amount of light, fatigue of the eyes is very high. Another problem is that when using electric heaters, the room tends to be dry by high heat. Indoor humidity maintenance is a very important factor in the prevention and treatment of respiratory diseases. Especially, it is essential for health care for infants, bronchial organs and people with weak respiratory because humidity is low in winter. In this study, we conducted a study to develop a product that can improve heating efficiency while maintaining proper indoor humidity by combining heat energy and moisture particles. The concept of humidification and heating at the same time, moisture particles generated in the humidifier pass through the heater, include thermal energy, and the moisture particles with thermal energy are diffused into the space by forced convection, thereby warming the entire space. In addition, the heating time is shortened as the feeling temperature is increased with the high relative humidity, and this has the effect that the heating cost in winter is reduced.

Hazard Levels of Cooking Fumes in Republic of Korea Schools

  • Lee, Iu-Jin;Lee, Sang-Gil;Choi, Bo-Hwa;Seo, Hoe-Kyeong;Choi, Ji-Hyung
    • Safety and Health at Work
    • /
    • v.13 no.2
    • /
    • pp.227-234
    • /
    • 2022
  • Background and Purpose: In 2021, lung cancer in school food workers was first recognized as an occupational cancer. The classification of the carcinogenicity of cooking fumes by International Agency for Research on Cancer (IARC) was based on Chinese epidemiological data. This study aimed to determine the hazard levels of school cooking fumes in Korea. Materials and Methods: Based on public school cafeterias in one area, 25 locations were selected for the survey according to the number per school type, ventilation states, and environmental pre-assessments of cafeterias. Two inside cooking areas using a heat source and one outside cooking area were selected as control measurement points. Measurements of CO, CO2, polycyclic aromatic hydrocarbons (PAHs), and total volatile organic compounds (TVOCs), including benzene, formaldehyde, and particulate matter (PM10, PM2.5, PM1, respectively), were taken. The concentrations and patterns of each substance in the kitchens were compared with the outdoor air quality. Result: Known carcinogens, such as the concentrations of PAHs, formaldehyde, TVOC (benzene), and particulate matter in school cooking fumes, were all detected at similar or slightly higher levels than those found outside. Additionally, substances were detected at relatively low concentrations compared to the Chinese cooking fumes reported in the literature. However, the short-term exposure to high concentrations of CO (or composite exposure with CO2) and PM2.5 in this study were shown. Conclusion: The school cooking fumes in South Korea was a relatively less harmful than Chinese cooking fumes, however short-term, high exposure of toxic substances can cause a critical health effect.

Study Case on the Log Cultivation of Phellinus baumii for It's High Quality and Large Quantity (고품질 다수확 원목 상황버섯 재배 경영사례 조사)

  • Suh, Gyu-Sun;Chang, Hyun-You;Kim, Soon-Geun
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.10 no.1
    • /
    • pp.153-167
    • /
    • 2008
  • High temperature and natural sun light are considered as the core conditions for high quality and large quantity of Phellinus baumii production. However still now on there has been a mistake of excessively cutting off the natural light by spreading the closing nets on the mushroom cultivating house. For an example there are many houses where the closing nets under the roofs be extended to cover the sides of the houses, which way prevents the mushrooms in the houses from receiving sufficient natural sun light and getting the temperature sufficiently to grow so that the quantity and quality of the produced mushrooms are lowered even though the mushrooms can grow in those conditions. In order to avoid this mistake, the closing nets must be placed on the roofs of the houses only without dropping them to cover the sides. Further more when the closing nets are placed triply at the beginning stage of Phellinus baumii's growth in the house, the nets restrain the internal temperature of the house going up and intercept the natural bright light flowing into the house so that the growing tardiness occur to the Phellinus baumii. Therefore the roof only must have been covered by the closing net for 65% cutting off the light until May, and then covered by double folded the net for June, triple folded the net for July and August, double folded the net for September, and the single net for October. When the ventilation in the house has been maintained until the house tightly balloon out through controling lifting force of internal air, the Phellinus baumii can grow well while the bed logs themselves aren't dried out. Marketing is also very much important as well as increasing quality and quantity of Phellinus baumii production.

Developing a BIM-Based Methodology Framework for Sustainability Analysis of Low Carbon High-Rise Buildings

  • Gan, Vincent J.L.;Li, Nan;Tse, K.T.;Chan, C.M.;Lo, Irene M.C.;Cheng, Jack C.P.
    • International conference on construction engineering and project management
    • /
    • 2017.10a
    • /
    • pp.14-23
    • /
    • 2017
  • In high-density high-rise cities such as Hong Kong, buildings account for nearly 90% of energy consumption and 61% of carbon emissions. Therefore, it is important to study the design of buildings, especially high-rise buildings, to achieve lower carbon emissions in the city. The carbon emissions of a building consist of embodied carbon from the production of construction materials and operational carbon from energy consumption during daily operation (e.g., air-conditioning and lighting). An integrated analysis of both types of carbon emissions can strengthen the design of low carbon buildings, but most of the previous studies concentrated mainly on either embodied or operational carbon. Therefore, the primary objective of this study is to develop a holistic methodology framework considering both embodied and operational carbon, in order to enhance the sustainable design of low carbon high-rise buildings. The framework will be based on the building information modeling (BIM) technology because BIM can be integrated with simulation systems and digital models of different disciplines, thereby enabling a holistic design and assessment of low carbon buildings. Structural analysis program is first coupled with BIM to validate the structural performance of a building design. The amounts of construction materials and embodied carbon are then quantified by a BIM-based program using the Dynamo programming interface. Operational carbon is quantified by energy simulation software based on the green building extensible Markup Language (gbXML) file from BIM. Computational fluid dynamics (CFD) will be applied to analyze the ambient wind effect on indoor temperature and operational carbon. The BIM-based framework serves as a decision support tool to compare and explore more environmentally-sustainable design options to help reduce the carbon emissions in buildings.

  • PDF

Exposure Assessment of Tile Manufacturing Workers to Crystalline Silica (타일 제조 작업자의 결정형 유리규산 노출평가 사례)

  • Won-Seok Cha;Eun-Young Kim;Dae-Ho Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.3
    • /
    • pp.291-297
    • /
    • 2023
  • Objectives: An epidemiological investigation was requested for a worker who developed COPD and IPF after long-term molding and firing at a domestic tile manufacturing site. We would like to share the results of the exposure assessment and the estimation of past work. Methods: The content of crystalline silica in four raw materials was analyzed, and the respirable fraction of crystalline silica and dust generated in the air from molding and firing workers and other processes were measured. The measurement and analysis method referred to the NIOSH method. Results: The crystalline silica content of the raw material was 24~47%. The concentration of crystalline silica in the molding and firing process workers and the surrounding area was at the level of the exposure standards set by the Ministry of Employment and Labor and ACGIH, and the respirable and total dust exposure levels were generally low. The crystalline silica concentration of the area samples measured to estimate past work was about twice as high as the exposure standard of the Ministry of Employment and Labor (0.05 mg/m3), and the exposure levels of respirable dust were also quite high at 0.903 and 1.332 mg/m3. Conclusions: It was confirmed that tile molding and firing workers are currently exposed to a fairly high level of crystalline silica, and a high level is also confirmed in area samples to estimate past work. In the past, it is judged that the level of exposure would have been much higher due to differences in production volume, working method, presence/absence of local ventilation facilities, and process layout. When working in such a working environment for a long time, respiratory diseases such as lung cancer, COPD, and IPF can occur.