• Title/Summary/Keyword: Air unit

Search Result 1,592, Processing Time 0.027 seconds

Leakage and scattered radiation from hand-held dental x-ray unit (이동용 치과 X선 발생장치의 누설 및 산란 선량에 관한 연구)

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.37 no.2
    • /
    • pp.65-68
    • /
    • 2007
  • Purpose: To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. Materials and Methods: For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR III was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of handheld dental X-ray unit were 70 kVp, 3 mA, 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. Results: The mean dose at the hand level when human skull DXTTR III was exposed with portable X-ray unit $6.39{\mu}Gy$, and the mean dose with fixed X-ray unit $3.03{\mu}Gy$ (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was $2.97{\mu}Gy$ and with fixed X-ray unit the mean dose was $0.68{\mu}Gy$ (p<0.01). Conclusions: The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography.

  • PDF

Simulation to identify the frost formation of the heat pump outdoor unit (히트펌프 실외기의 서리층 형성을 파악하기 위한 시뮬레이션)

  • Kim, Jong-Ryeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.1410-1419
    • /
    • 2019
  • In this research, it is to find a method that frost does not form on the outdoor unit to develop a heat pump capable of heating in cold regions. For this reason, we produced an incubator capable of creating an environment of -25℃, and constructed an experimental apparatus so that experiments in the room were possible. However, it is necessary to grasp the characteristics of the air reaching the front of the heat pump outdoor unit installed in the experimental apparatus, and flow analysis was performed using ANSYS CFX, which is general-purpose software. As a result, the flow velocity of the air reaching the front of the outdoor unit in the outdoor unit chamber in the entire region of the simulation conditions (5.0 to 7.5 m/s) has many differences in the upper and lower portions, resulting in a natural state. It turned out that the condition can not be satisfied. Therefore, it is determined that it is necessary to additionally install a frequency divider at the front of the outdoor unit to make the flow velocity constant.

Wafer Motion Control of Clean Tube System (클린튜브 시스템의 웨이퍼 운동 제어)

  • 신동헌;최철환;정규식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.475-481
    • /
    • 2004
  • This paper presents a force model of the clean tube system, which was developed as a means of transferring air-floated wafers inside a closed tube filled with super clean air. The recovering force from the holes for floating wafers is modeled as a linear spring and thus the wafers motion is modeled as a mass-spring-damper system. The propelling forces are modeled as linear along with the wafer location. The paper also proposes a control method to emit and stop a wafer at the center of a control unit. It reveals the minimum value of the propelling force to leave from the control unit. In order to stop the wafer, it utilizes the exact time when the wafer arrives at the position to activate the propelling force. Experiments with the clean tube system built for the 12 inch wafer shows the validity of the proposed model and the algorithm.

Improved Performance Through Air Conditioner Outdoor Fan Airflow Increase and Relative Cost Reduction (에어컨 실외기 풍량증가를 통한 성능 향상 및 상대적 원가절감)

  • Kim, Jae-Yeol;Choi, Seung-Hyun;Kim, Sung-Hyun;Ki, Suk-Ho;Yoon, Sung-Un
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.4
    • /
    • pp.570-574
    • /
    • 2012
  • Spread of household air conditioning system is continued to be increased. Axial fan in the external unit of air conditioning system is for ventilation and air supplying unit, and the related products have been widely adopted as household electronics, automobile engine, big sized blower in factory, tunnel, and subway. In this study, commercial 3-winged propeller fan is modified to shape and modified to 2-winged fan for the airflow increase and cost reduction. Using 3D modelling, the fan shape is modified, and analysis flow is adopted to provide the way to airflow increase and reduce cost while maintaining the same wind capacity.

A Study on the Gun-Oriented Anti Air Warfare Capability of the Patrol Killer Combat System (고속정 전투체계의 함포 중심 대공전 성능 분석)

  • Hwang, Kun-Chul
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.62-72
    • /
    • 2007
  • The Gun-Oreinted Anti-Air Warfare(GOAAW) which is still one of the important weapon systems of the vessel like the patrol killer to confront air threats comprises the components of the combat system - Command & Control(C2), Ballistic Calculation Unit, Sensors and Guns. In this paper, the GOAAW process of the patrol killer combat system is analyzed with probability and simulated to evaluate the effectiveness and capability of the GOAAW. As a result of the simulation, the performance measures of the GOAAW are discussed in the functional and operational aspects of the combat system.

Anti-air Unit Learning Model Based on Multi-agent System Using Neural Network (신경망을 이용한 멀티 에이전트 기반 대공방어 단위 학습모형)

  • Choi, Myung-Jin;Lee, Sang-Heon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.49-57
    • /
    • 2008
  • In this paper, we suggested a methodology that can be used by an agent to learn models of other agents in a multi-agent system. To construct these model, we used influence diagram as a modeling tool. We present a method for learning models of the other agents at the decision nodes, value nodes, and chance nodes in influence diagram. We concentrated on learning of the other agents at the value node by using neural network learning technique. Furthermore, we treated anti-air units in anti-air defense domain as agents in multi. agent system.

The Study on the Aeroacoustic Characteristics of an Axial Fan for an Air-Conditioner (공기조화기 축류팬의 공력소음 특성 연구)

  • Lee, Soo-Young;Han, Jae-Oh;Kim, Tae-Hun;Lee, Jai-Kwon;Jeon, Wan-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.205-208
    • /
    • 2006
  • This paper proposes a new computational aeroacoustics method for an axial fan analysis. The major aeroacoustic noise source of an outdoor air-conditioner is the axial fan. It was revealed that the dominant noise source is the aerodynamic interactions between the rotating blade and stationary orifice. Many researches were focused on the fan only case. However, it does not fit to a real outdoor unit of air-conditioner. Especially, the inlet part of the axial fan of real system case is complex and not uniform. So, in order to identify the dominant noise source of axial fan, full outdoor unit analysis is important. Transient CFD analysis of full system was performed by commercial CFD code - SC/Tetra. Dominant noise source of the system was calculated by commercial CFN code - FlowNoise. The results show that not only BPF peaks but also broadband noise are similar to the measured data.

  • PDF

Suggestion of Allocation Methodology of Environmental Pollution Cost on Multi - Product (복합생산품에 대한 환경오염비용 배분 방법론)

  • Kim, Deok-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.5
    • /
    • pp.311-318
    • /
    • 2009
  • In previous study, a new allocation methodology of common cost on multi-product have been suggested. The aim of this study is to suggest the methodology that allocates an environment pollution cost including carbon emission cost to each cost of multi-product. For this study, a supposed multi-energy system composed of twenty kinds of systems was made. The multi-energy system produces eighteen kinds of outputs that are electricity, steam, hot water, chilled water, ice, warm air, and cooling air from seven kinds of energy source that are LNG, coil, geothermal energy, sun heat, hydrogen, bio-mass, and waste. The new methodology was applied to the multi-energy system in order to allocate the environment pollution cost to each production cost, and twenty seven equations were induced. From this result, it is concluded that this methodology can estimate each unit cost and allocate each cost flow in any product of any energy system.

Experimental Study on the Effect of Environmentally Friendly Materials on Indoor Air Quality in New Apartment Buildings (신축 공동주택에서의 친환경 마감자재 사용에 따른 실내공기질 개선효과 실증연구)

  • Park, Young-Sok;Lee, Gyu-Dong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.139-142
    • /
    • 2006
  • The indoor air quality of new apartment buildings, which is known to cause sick housing syndrome, has become a major concern among apartment residents as well as construction companies in Korea. In this study, the effects of environmentally friendly materials and ventilation system are evaluated to compare the strategies applied to improve indoor air quality at the pre-occupancy stage. Six residential units are tested under three conditions : one unit is consisted of environmentally friendly materials and ventilation system, another unit is consisted of environmentally friendly materials and non-ventilation system, and the other four units are consisted of common materials and non-ventilation system.

  • PDF

Air Pollutant Reduction Effect on Road Mobility in Hydrogen Economy Era (수소경제 활성화 로드맵 달성에 따른 교통 부문의 대기오염원 저감 효과 분석)

  • KIM, JUNGHWA
    • Journal of Hydrogen and New Energy
    • /
    • v.31 no.6
    • /
    • pp.522-529
    • /
    • 2020
  • This study evaluated the effect of improving the atmospheric environment based on the premise that the supply of hydrogen fuel cell vehicles (HFCV) will be achieved as many as the number of vehicles presented in the hydrogen economy activation roadmap announced by the Korean government in January 2019. The HFCV supply target (2.7 million passenger cars) suggested in the hydrogen economy revitalization roadmap was logically allocated to the five major metropolitan areas in Korea. Air pollution damage costs by region were calculated by reflecting the basic unit of damage cost to the estimated air pollutant emissions. As a result, it was confirmed that the benefits per unit of some cities in Gyeonggi-do were derived more than major cities in the metropolitan area.