• Title/Summary/Keyword: Air unit

Search Result 1,592, Processing Time 0.044 seconds

Architecture of A Launch Control Unit for the Compatibility of Weapon Systems Based on Shipboard (함정 기반 다중 무장 호환 운용을 위한 발사제어기 아키텍처)

  • Shin, JinBeom;Cho, KilSeok;Yoo, MyongHwan;Kim, TaeHyon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.176-184
    • /
    • 2020
  • In this paper, we have proposed hardware and software architecture of a launch control unit for the compatibility between air defense weapon systems loaded on shipboard. Until now, there is no compatibility between weapon systems loaded in battleships of korean navy. In the case of HaeGung system recently completed the test and evaluations, although it will be deployed on several kinds of shipboards, it has no compatibility and flexibility with other air defense weapon systems. Recently it reports that a long range air defense weapon system will be carried on future korean destroyer KDDX. Because the HaeGung and a long range air defense system will be operated together in KDDX, it is necessary to provide the compatibility between two weapon systems. So we have proposed architecture to provide the compatibility of the launch control unit that controls the launching system and the missile interface unit, and the missile in each weapon systems.

Effects of Various Packaging Systems on the Quality Characteristic of Goat Meat

  • Morales-delaNuez, A.;Moreno-Indias, I.;Falcon, A.;Arguello, A.;Sanchez-Macias, D.;Capote, J.;Castro, N.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.22 no.3
    • /
    • pp.428-432
    • /
    • 2009
  • 40 goat kid ribcages were held for 7 days in storage conditions ($4^{\circ}C$) and used to determine the effects of three different packaging methods (atmospheric air, vacuum and modified atmosphere package (MAP) 10:70:20 mixture of $N_2:O_2:CO_2$) on meat quality of the chops. L* was affected by the packaging method being lighter than MAP chops. The coordinate a* significantly increased during storage time. For MAP-packed chops and those kept in atmospheric air, b* increased markedly during storage time whereas it remained unaffected throughout storage when in vacuum packages. Final pH values ranged from 5.6 to 5.8 and no effects were found for either storage time or packaging method. WHC means were lowest for the three packaging methods on day 7 of storage and highest on day 1. Storage time increased water loss in vacuum treatments. Trained panel colour acceptability was lower at 3, 5 and 7 days than on day 1 of storage for atmospheric air treatment and vacuum packaging, while for the MAP treatment average values on days 5 and 7 were lower than those observed on days 1 or 3. Trained panel odour was lower for atmospheric air and vacuum packages at 3, 5, and 7 days storage than at 1 day, while no differences were found in trained panel odour acceptability for MAP packages. With reference to consumers, the MAP proposed in the present study is the chosen method for storing goat meat, rather than vacuum or atmospheric air packaging.

Numerical and experimental study on the pressure dorp of axial-flow cyclone in the air handling unit (공기조화기 장착용 축상유입식 싸이클론의 압력손실에 대한 수치해석 및 실험적 연구)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Youngmin;Kim, Se-Young;Kim, Myeoung-Joon;Kim, Hojoong;Kim, Taesung
    • Particle and aerosol research
    • /
    • v.5 no.2
    • /
    • pp.37-43
    • /
    • 2009
  • Particulate matter (PM) is one of the major indoor air pollutants especially in the subway station in Korea. In order to remove PM in the subway station, several kinds of PM removal system such as roll-filter, auto-washable air filter, demister, and electrostatic precipitator are used in the air handling unit (AHU) of subway stations. However, those systems are prone to operation and maintenance problems since the filter-regeneration unit consisting of electrical or water jet parts might malfunction due to the high load of particulates unless the filter medium is periodically replaced. In this study, the use of axial-flow cyclone was proposed for particulate filter unit in the AHU for its low operation and maintenance cost. Novel shape of axial-flow cyclone was designed by using computational fluid dynamics (CFD). The shape of vortex vane was optimized in terms of pressure drop and tangential velocity. In addition, CFD analysis was validated experimentally through the pressure drop measurement of mock-up model. We found that pressure drop and tangential velocity of fluid through the axia-flow cyclone was significantly affected by the rotating degree of vortex vane and the numerical prediction of pressure drop agreed well with experimental measurement.

  • PDF

Goal Regulation Mechanism through Reinforcement Learning in a Fractal Manufacturing System (FrMS) (프랙탈 생산시스템에서의 강화학습을 통한 골 보정 방법)

  • Sin Mun-Su;Jeong Mu-Yeong
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2006.05a
    • /
    • pp.1235-1239
    • /
    • 2006
  • Fractal manufacturing system (FrMS) distinguishes itself from other manufacturing systems by the fact that there is a fractal repeated at every scale. A fractal is a volatile organization which consists of goal-oriented agents referred to as AIR-units (autonomous and intelligent resource units). AIR-units unrestrictedly reconfigure fractals in accordance with their own goals. Their goals can be dynamically changed along with the environmental status. Since goals of AIR-units are represented as fuzzy models, an AIR-unit itself is a fuzzy logic controller. This paper presents a goal regulation mechanism in the FrMS. In particular, a reinforcement learning method is adopted as a regulating mechanism of the fuzzy goal model, which uses only weak reinforcement signal. Goal regulation is achieved by building a feedforward neural network to estimate compatibility level of current goals, which can then adaptively improve compatibility by using the gradient descent method. Goal-oriented features of AIR-units are also presented.

  • PDF

Numerical Study on the Air-Cushion Glass Transportation Unit for LCD Panels

  • Im Ik-Tae;Jeon Hyun-Joo;Kim Kwang-Sun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.1 s.14
    • /
    • pp.27-31
    • /
    • 2006
  • Non-contact transportation system using air cushion for the manufacturing of large-sized LCD panels was considered. Flow characteristics between air pad and glass plate was analyzed using computational fluid dynamics method to obtain optimized air pad configurations. Effects of the design variables such as hole arrays from which gas is injected, gas-feeding method into the gas supplying channels, and horizontal and vertical pitches of clusters of holes were studied. Optimized air pad unit gave evenly distributed pressure contour on the glass surface and well-suspended levitation height in the experiment.

  • PDF

Numerical Study on the Air-Cushion Unit for Transportation of Large-Sized Glass Plate

  • Jun, Hyun-Joo;Kim, Kwang-Sun;Im, Ik-Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.1 s.18
    • /
    • pp.59-64
    • /
    • 2007
  • Non-contact transportation of a large-sized glass plate using air cushion for the vertical sputtering system of liquid crystal display (LCD) panel was considered. The objective of the study was to design an air pad unit which was composed of multiple injection and exhaust holes and mass flow supplying pipe. The gas was injected through multiple small holes to maintain the force for levitating glass plate. After hitting the plate, the air was vented through exhaust holes. Complex flow field and resulting pressure distribution on the glass surface were numerically studied to design the air injection pad. The exhaust hole size was varied to obtain evenly distributed pressure distribution at fixed diameter of the injection hole. Considering the force for levitating glass plate, the diameter of the exhaust hole of 30 to 40 times of the gas injection hole was recommended.

  • PDF

Design and performance analysis of water-to-air heat pump system using double-tube heat exchanger (이중관 열교환기를 사용한 물 대 공기 열펌프 시스템의 설계와 성능해석)

  • Han, D.Y.;Park, K.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.462-471
    • /
    • 1997
  • The water-to-air heat pump system requires relatively lower energy consumption and less installation space. The heat exchangers used for this system are the finned-tube type for the indoor unit and the double-tube type for the outdoor unit. Mathematical models for this system are developed and programmed in computer. Experimental data from various conditions are obtained and compared with calculated values from the computer simulation program. Differences of cooling capacity and COP are 1.25% and 0.47%, and those of heating capacity and COP are 0.51% and 0.13%, respectively. Simulation results are in good agreement with test results. Therefore, the developed program is effectively used for the design and the performance prediction of water-to-air heat pump system.

  • PDF

Reduction of the Refrigerant-Induced Noise from the Transition of Flow Pattern by Decreasing Tube Diameter

  • Takushima, Akira;Han, Hyung-Suk;Jung, Wei-Bong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.2
    • /
    • pp.37-44
    • /
    • 2009
  • It is well known that a refrigerant-induced noise is caused by two-phase flow in the indoor unit of a heat pump air-conditioner. Especially when the flow pattern in a pipe is intermittent flow, the irregular noise occurs frequently. But it is very difficult to avoid this kind of the noise for the application of air-conditioner. Therefore, in this research, the flow patterns at two-phase flow state in a pipe of the indoor unit for the air-conditioner are researched using cycle simulator at typical cycle conditions. In order to find the relationship between refrigerant-induced noise and flow pattern, the noise patterns are investigated with respect to the estimated flow pattern from the various flow pattern maps. Base on the estimations of the flow patterns by those maps, the refrigerant-induced noise is evaluated as decreasing tube diameter, which can transit the flow pattern from slug to annular flow.

Precise Air-Fuel Ratio Control on Transient Conditions with the PC-ECU in SI Engine (PC-ECU를 이용한 SI 기관의 비정상상태 정밀공연비 제어)

  • Yoon, S.H.
    • Journal of ILASS-Korea
    • /
    • v.5 no.3
    • /
    • pp.9-16
    • /
    • 2000
  • In a SI engine, three-way catalyst converter has the best efficiency when A/F ratio is near the stoichiometry. The feedback control using oxygen sensors in the commercial engine has limits caused by the system delays. So it is necessary to control fuel quantity in accordance with intake air amount in order to reduce exhaust emission and improve the specific fuel consumption. Precise A/F ratio control requires measurement of air amount with respect to the cylinder and injection fuel according to the air amount In this paper, we applied nonlinear fuel injection model and developed the algorithm of A/F ratio control. This algorithm includes the methods of measurement of transient air mass flowing into each cylinder, of calculation of injection pulse width for measured air mass, and the method of feedback and engine control by using lambda sensor. Also we developed control program for IBM-PC by using C++ Builder, and tested it in the commercial engine.

  • PDF

A Study on Air-distribution method for the Thermal Environmental Control in the Data Center (데이터센터의 합리적인 환경제어를 위한 공기분배 시스템에 대한 연구)

  • Cho, Jin-Kyun;Cha, Ji-Hyoung;Hong, Min-Ho;Yeon, Chang-Kun
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.487-492
    • /
    • 2008
  • The cooling of data centers has emerged as a significant challenge as the density of IT server increases. Server installations, along with the shrinking physical size of servers and storage systems, has resulted in high power density and high heat density. The introduction of high density enclosures into a data center creates the potential for "hot spots" within the room that the cooling system may not be able to address, since traditional designs assume relatively uniform cooling patterns within a data center. The cooling system for data center consists of a CRAC or CRAH unit and the associated air distribution system. It is the configuration of the distribution system that primarily distinguishes the different types of data center cooling systems, this is the main subject of this paper.