• Title/Summary/Keyword: Air system model

Search Result 2,062, Processing Time 0.027 seconds

A Numerical Analysis on Forced Ventilation using Indoor Air Cleaner in an Apartment House (아파트주택에 있어서 실내공기청정기에 의한 환기의 수치해석)

  • 고재윤;김일겸;최병훈;임장순
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.3
    • /
    • pp.217-223
    • /
    • 2001
  • There exist a number of approaches which can evaluate ventilation and indoor air quality. The measurement and analysis of indoor carbon dioxide concentrations can be useful for evaluating indoor air quality and ventilation. This paper describes a numerical analysis of carbon dioxide concentrations for evaluating indoor air quality and ventilation and the factors the need to be considered in their use. The conditions of this numerical analysis are tow types of positions and inlet velocities of ventilation system in a two-dimensional model of an apartment house. The simulation results could be used as a base data for further analysis for ventilation design of other industrial processes producing a proper ventilation system for a healthier and more comfortable environment in a building.

  • PDF

Acoustical Characteristics of Air Filter in the Engine Intake System (엔진 흡기계 공기 여과기의 음향 특성)

  • Kang, J.H.;Ih, J.G
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.190-193
    • /
    • 2005
  • The air filter in engine intake system filters the dirt in the breathing air but also it attenuates the noise although the phenomenon has been regarded negligible. For the analysis of the acoustical performance of air filter, an acoustical model is suggested in this paper. The air filter consists of a porous filter element, which catches the particulate dirt, and a plastic filter box, which supports the filter element. Fibrous structure of the filter element is modeled as a micro-perforated panel using the flow resistivity and porosity. The pleated geometry of the filter element is modeled as two coupled ducts and a mathematical model is developed for the analysis of sound propagation. The filter box Is modeled as a rigid rectangular box. By combining two models, a 4-pole transfer matrix for the air filter is derived. The transmission loss calculated using the transfer matrix of the suggested model is compared with the measured data. Reasonably good agreement is observed. The result can be improved by considering the visco-thermal effect in modeling, in particular at a frequency range near the troughs of TL curve.

  • PDF

Evaluation of energy efficiency ratio in the mixed air conditioner system (혼합 공조 시스템의 EER(A) 평가)

  • 김병순;이승홍
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.542-548
    • /
    • 1999
  • Instead of testing split air conditioners, an empirically based calculation procedure may be used to estimate the Energy Efficiency Ratio at ARI A test conditions. Typically, the system involving the indoor unit well sold and the given outdoor unit is called the matched system. All other systems involving a given outdoor unit and other indoor units are called the mixed systems. To estimate the EER(A) for the mixed systems, EER(A) for the matched system must be known, Generally, the EER(A) for the matched system is known. This procedure relies on independent measurements and calculations made on an outdoor unit in conjunction with a matched indoor and a mixed indoor coil. A heat pump simulation model was used to quantify the effects of individual system components on the system performance. The procedure is applicable to all air-conditioning units having rated cooling capacities less than 19,000W and charged with refrigerant 22.

  • PDF

A Study on Thermal Analysis for a Data Center Cooling System under Fault Conditions at a Chilled Water Plant (비상시 열원중단에 따른 데이터센터의 냉각시스템 열성능 평가에 관한 사례연구)

  • Cho, Jinkyun;Kang, Hosuk
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.5
    • /
    • pp.178-185
    • /
    • 2016
  • This study describes the analysis of a 20 MW chilled water plant used for the IT cooling of a recently constructed data center in Korea. The CFD model was developed with the aim of evaluating the impact of problems such as chiller failure on the water and air temperatures in the cooling system. The numerical model includes the chilled water hydraulic network and individual water-to-air CRAC units. The coupling between the IT server room air temperature levels and the cooling plant has enabled a full assessment of the cooling system design in response to system fault conditions to be performed. The paper examines an emergency situation involving the failure of the cooling plant, and shows how the inherent thermal inertia of the system along with additional inertia achieved through buffer systems allowed a suitable design to be achieved.

Nonlinear Sliding Mode Control of an Axial Electromagnetic Levitation System by Attractive Force (흡인력을 이용한 자기 부상계의 비선형 슬라이딩 모드 제어)

  • 이강원;고유석;송창섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.10
    • /
    • pp.165-171
    • /
    • 1998
  • An axial electromagnetic levitation system using attractive force is a highly nonlinear system due to the nonlinearity of materials, variable air gap and flux density. To control the levitating system with large air gap, a conventional PID control based on the linear model is not satisfactory to obtain the desired performance and the position tracking control of the sinusoidal motion by simulation results. Thus, sliding mode control(SMC) based on the input-output linearization is suggested and evaluated by simulation and experimental approaches. Usefulness of the SMC to this system is conformed experimentally. If the expected variation of added mass can be included in the gain conditions and the model, the position control performance of the electromagnetic levitation system with large air gap will be improved with robustness.

  • PDF

Analysis of the Effects of CO Poisoning and Air Bleeding on the Performance of a PEM Fuel Cell Stack using First-Order System Model (일차계 모델을 이용한 고분자전해질 연료전지 스택의 CO Poisoning 및 Air Bleeding 효과 분석)

  • Han, In-Su;Shin, Hyun Khil
    • Korean Chemical Engineering Research
    • /
    • v.51 no.3
    • /
    • pp.370-375
    • /
    • 2013
  • We analyze the effects of CO poisoning and air bleeding on the performance of a PEM (polymer electrolyte membrane) fuel cell stack fabricated using commercial MEA (membrane electrode assembly). Dynamic response data from the experiments on the performance of a stack are identified by obtaining steady-state gains and time-constants of the first-order system model expressed as a first-order differential equation. It is found that the cell voltage of the stack decreases by 1.3-1.6 mV as the CO concentration rises by 1 ppm. The time elapsed to reach a new steady state after a change in the CO concentration is shortened as the magnitude of the change in the CO concentration increases. In general, the steady-state gain becomes bigger and the time-constant gets smaller with increasing the air concentration (air-bleeding level) in the reformate gas to restore the cell voltage. However, it is possible to recover 87%-96% of the original cell voltages, which are measured with free of CO, within 1-30 min by introducing the bleed air as much as 1% of the reformate gas into the stack.

Modelling CO2 and NOx on signalized roundabout using modified adaptive neural fuzzy inference system model

  • Sulaiman, Ghassan;Younes, Mohammad K.;Al-Dulaimi, Ghassan A.
    • Environmental Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.107-113
    • /
    • 2018
  • Air quality and pollution have recently become a major concern; vehicle emissions significantly pollute the air, especially in large and crowded cities. There are various factors that affect vehicle emissions; this research aims to find the most influential factors affecting $CO_2$ and $NO_x$ emissions using Adaptive Neural Fuzzy Inference System (ANFIS) as well as a systematic approach. The modified ANFIS (MANFIS) was developed to enhance modelling and Root Mean Square Error was used to evaluate the model performance. The results show that percentages of $CO_2$ from trucks represent the best input combination to model. While for $NO_x$ modelling, the best pair combination is the vehicle delay and percentage of heavy trucks. However, the final MANFIS structure involves two inputs, three membership functions and nine rules. For $CO_2$ modelling the triangular membership function is the best, while for $NO_x$ the membership function is two-sided Gaussian.

Numerical Analysis of Wintertime Air Pollution in East Asia Region Using Long-Range Transport Model

  • Jang, Eun-Suk
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.2
    • /
    • pp.103-110
    • /
    • 2000
  • In order to understand the wintertime intermittent characteristics of the trans-boundary air pollutant transport observed in East Asia, a numerical simulation of the long-range transport of pollutants was applied using an atmospheric transport model(STEM-II). The numerical simulation was carried out for the entire month of January 1997 and specific atmospheric aerosol (including sulfate, nitrate, and other ion compounds0 observation data were compared from four observation sites(Cheju Island, Kanghwa Island, Dazaifu, and Fukue Island). The observation data revealed that concentration peaks were intermittently observed at 3 to 4-day intervals plus the four observation sites exhibited a very similar spatial variation. The horizontal and spatial scale of the heavily polluted air masses was analyzed based on numerical results. The mechanism of the intermittent transport of air pollutants was clearly explained by a comparison of the observed data with the numerical output. It was found that the wind pattern variations associated with the synoptic scale pressure system changes play an extremely important role in the transport of pollutants in this region.

  • PDF

Heat Transfer Enhancement of a Piezoelectric Fan for Cooling of Electronic Devices (전자기기 냉각용 압전팬의 열전달 향상)

  • Kim, Eun-Pil;Yoon, Jung-In
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.14-21
    • /
    • 2014
  • Piezoelectric fans are thin elastic beams whose vibratory motion is actuated by means of a piezoelectric material bonded to the beam. These fans have found use as a means to enhance convective heat transfer while requiring only small amounts of power. This study presents new types of models with heat sink having air passage and investigates experimentally their heat transfer characteristics. From the comparison results for four models, the heat transfer coefficients of model 1 are approximately 44~66% higher than those of the reference model 0. The model 1 show the best overall performance about heat transfer and cooling capability. As shown in above results, it is necessary to design the heat sink with air pass for cooling of electronic devices, in order to increase the convective heat transfer coefficient of a piezoelectric fan for electronic cooling.

Optimal Placement of CRNs in Manned/Unmanned Aerial Vehicle Cooperative Engagement System

  • Zhong, Yun;Yao, Peiyang;Wan, Lujun;Xiong, Yeming
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.1
    • /
    • pp.52-68
    • /
    • 2019
  • Aiming at the optimal placement of communication relay nodes (OPCRN) problem in manned/unmanned aerial vehicle cooperative engagement system, this paper designed a kind of fully connected broadband backbone communication topology. Firstly, problem description of OPCRN was given. Secondly, based on problem analysis, the element attributes and decision variables were defined, and a bi-level programming model including physical layer and logical layer was established. Thirdly, a hierarchical artificial bee colony (HABC) algorithm was adopted to solve the model. Finally, multiple sets of simulation experiments were carried out to prove the effectiveness and superiority of the algorithm.