• 제목/요약/키워드: Air supply fan

검색결과 71건 처리시간 0.024초

강제대류방식 PCM 축냉장고 개발 (The Development of a PCM Cold Storage Refrigerator using Forced Convection Method)

  • 이상렬;류인근;김진홍;전용호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.517-522
    • /
    • 2005
  • A cold storage refrigerator using phase change material(PCM) has been developed and its performance test results are provided here. The inner temperature of the refrigerator is controlled with forced convection driven by a fan using a DC battery. At the first, to freeze all the PCM of the ambient temperature by a built-in refrigerating machine, it took about 8 and 10 hours respectively at the refrigerator and the freezer mode. Then, without external power supply, the inner temperature of the cold storage refrigerator has been maintained at $-18{\pm}1^{\circ}C$ during 14 hours at the freezer mode and maintained at $3{\pm}^{\circ}C$ during 34 hours at the refrigerator mode. Just after the end of its valid usage as a refrigerator or a freezer, it took about 6 hours to refreeze the PCM for its reuse. During the test, the ambient temperature was kept at $30^{\circ}C$.

  • PDF

굴뚝효과와 외부출입문 개방을 고려한 부속실 제연 (Vestibule Smoke Control Considering the Stack Effect and the Opening of the Outside Door)

  • 김용광;손주달;김서영;공하성
    • 대한안전경영과학회지
    • /
    • 제26권1호
    • /
    • pp.15-24
    • /
    • 2024
  • The purpose of this study is to improve the stack effect of the staircase and the failure to take into account the opening of the outside door of the staircase, which are the disadvantages of the existing smoke control only vestibule. As a result of the study, the new vestibule and the staircase simultaneous smoke control are equipped with an exhaust flap damper with an effective opening area of about 0.25 m2 in the upper part of the staircase, and a ventilator-type air supply fan of about 5 m3/s in the lower part, and take measures to prevent overpressure in the staircase. If you use the new simultaneous smoke control method of the vestibule and staircase, you can achieve the following effects. First, it is possible to open the external entrance door. Second, it can reduce the stack effect. Third, the staircase door closes automatically without fail. And a new method of preventing overpressure was proposed for the vestibule.

대형 주물공정 용접작업장의 건강 위해인자 및 환기 개선 (Health Risk Factors and Ventilation Improvements in Welding Operation at Large-sized Casting Process)

  • 정종현;정유진;이상만;이정희;손병현;임현술
    • 청정기술
    • /
    • 제20권2호
    • /
    • pp.171-178
    • /
    • 2014
  • 이 연구에서는 대형 주물공정 용접작업장 근로자들의 건강보호 및 작업환경 개선을 위해 위해인자 조사 및 분석작업을 수행하였다. 또한, 대상 작업장의 작업환경을 개선하기 위해 측정 및 전산유체해석 모델링을 수행한 후 효과적인 환기방법을 제안하였다. 대형 주물공정 용접작업장 근로자들의 건강 위해인자를 조사한 결과, A사는 산화철분진, B사와 C사는 용접흄, D사는 용접 흄과 산화철분진이 주오염원인 것으로 확인되었다. 작업자 호흡영역에서의 흄 농도는 $0.05{\sim}4.37mg/m^3$이었고, 용접작업장 공기 중 흄 농도는 $0.13{\sim}7.54mg/m^3$이었다. 또한, 용접작업 시 최적의 환기방법을 제안하기 위해 측정 및 전산유체해석 모사를 수행한 결과, 배기공정의 경우에는 배기 덕트를 용접점에 근접시켜 국소배기를 실시하는 것이 효과적인 것으로 나타났다. 급기공정의 경우에는 개구부 끝 부분에서 급기를 하며 급기용 팬은 작업 공간 외부에 설치하는 것이 효과적일 것으로 나타났다. 향후 대형 주물공정 용접작업장의 터널형 반밀폐 공간에 대한 환기방법을 표준화한다면 주물산업 및 조선업 등에 종사하는 용접 근로자들의 건강보호 및 작업환경 개선에 매우 효과적일 것으로 판단된다.

지하철 화재시 제연모드에 따른 열 및 연기 배출 특성 연구 (A Study on Heat and Smoke Exhaust Characteristics from the Subway Fire for Different Ventilation Modes)

  • 장희철;윤경범;박원희;김태국
    • 한국방재학회 논문집
    • /
    • 제8권3호
    • /
    • pp.37-42
    • /
    • 2008
  • 본 연구는 지하철에서 화재발생시 최적의 제연모드 예측을 목적으로 수치해석을 수행하였다. 현재 국내 지하철 화재발생시 제연모드는 승강장 내 화재구역 배기, 비화재구역 급기 또는 정지로 설정 되어있다. 수치해석 조건은 2가지 국내 비상시 제연모드 및 발화 4분(승강장 피난허용시간, NFPA 130) 이전까지 승강장에서 배기를 하며, 발화 4분이 후 터널 배기로 전환되는 스위치모드의 3가지 경우에 대하여 비교 분석하였다. 승객 호흡높이(1.7 m)를 기준으로 열, 일산화탄소 및 가시거리를 비교하였다. 수치해석 결과 급기팬 작동은 연기를 교란시키고 확산시킬 수 있으며, 또한 승강장 및 터널 제연모드로 작동할 경우 승강장의 제연모드로만 작동한 경우에 비하여 연기 배출에 효과적임을 확인할 수 있었다.

TOP DOWN 지하공사의 작업환경체크 컴퓨터시물레이션에 관한 기초적 연구 (Computer Simulation for Working Condition of Undergroundwork Using TOP DOWN Technique)

  • 고성석;손기상;심경수
    • 한국안전학회지
    • /
    • 제10권3호
    • /
    • pp.96-105
    • /
    • 1995
  • The better industry develops, the more spaces need but in the limited area. Most building become larger and more complicated if the more spaces need in the constant area. And this leads to do underground work in long period generally six(6) months for 6 basement stories due to the selection of TOP DOWN technique. Working environment in this underground area can be problems and should not be overlooked, because air quality in underground spaces become quickly worse. Recently, department name to control construction safety has been changed to ENVIRONMENT & SAFETY TEAM from SAFETY TEAM. This means that it is very important to control against environmental condition at site so much. Overall construction work as well as underground work should conform to the requirement of working environment, particularly against inhabitants around the construction area. Strut protection, one of earth protection method, in case to 40m long strut may become weaker due to thermal stress or its longitudinally compressive strain and the another one, earth anchor protection may not be applied to the site In case of encroaching on vertical underground borderline because of regulation to prohibit it. It is necessary that TOP DOWN technique should be introduced in order to solve the external and internal problem of the site such as difficulty level of the work, potential danger with excavating depth, and shortening workperiod. It is needed that improving way of working condition should be shown and simplified computer simulation program should be also provided for checking pollution level & ventilation, excluding of lighting problem here. Results measured with conformance to the Regulation for Working Environment Measurement, enforced by Ministry of Labor have been applied to the computer program developed here. Sample air taken at unit workplace which was considered as exposing condition of pollutant at breathing point and within a range of behavior of the workers, Identified exposing group in underground work, using Moded Flow Life Finally, three types of ventilation system, type I with blower & ventilator, type II natural supply with mechanical ventilation system, and type I mechanical ventilation with Drivent Fan Unit System are selected for this study.

  • PDF

공동주택의 하이브리드 환기시스템 성능평가 연구 (A Study on the Performance of the Hybrid Ventilation System for Apartment Houses)

  • 전주영;김길태;김상희
    • 토지주택연구
    • /
    • 제3권1호
    • /
    • pp.89-96
    • /
    • 2012
  • 본 연구는 공동주택에서 하이브리드 환기시스템의 적용성을 검토하고, 하이브리드 환기시스템의 성능을 향상하기 위해 CFD시뮬레이션을 이용하여 설계방안을 제시하고자 하였다. 연구대상으로는 전용 $51m^2$, $84m^2$의 공동주택을 선정하였으며, 하이브리드 환기시스템은 창틀자연급기와 각실을 덕트로 연결하여 배기하는 시스템(Hybrid 1)과 창틀자연급기와 욕실 거실배기가 혼합된 시스템(Hybrid 2)을 적용하였다. 이때 각 시스템별 배기구의 위치를 변수로 하여 CFD를 수행하였다. $51m^2$, $84m^2$ 모두 Hybrid 2가 Hybrid 1보다 환기효율이 우수한 것으로 나타났으며, 평균공기연령 또한 낮은 것으로 나타났다. Hybrid 1의 경우, 덕트 배기구의 위치가 각 실 입구에 설치하는 것보다 실 안쪽 모서리에 설치하여 기류이동을 많이 유발할 수 있는 유형이 효과적인 것으로 나타났다. Hybrid 2의 경우, 욕실 고정압팬에 덕트를 연결하여 거실중심에 배기구를 설치하는 시스템이 환기효율이 가장 우수한 것으로 나타났다. 그러나 $51m^2$의 경우 Hybrid 2가 Hybrid 1보다 20%의 향상된 환기효율을 나타낸 반면, $84m^2$의 경우는 14%의 향상된 환기효율을 나타내 공동주택 규모에 따른 적정한 하이브리드 환기시스템에 대한 검토가 필요하다.

강제대류시 계절에 따른 KURT 내 열전달계수 결정에 관한 연구 (A Study on the Determination of the Seasonal Heat Transfer Coefficient in KURT Under Forced Convection)

  • 윤찬훈;권상기;황인필;김진
    • 방사성폐기물학회지
    • /
    • 제8권3호
    • /
    • pp.189-199
    • /
    • 2010
  • 고준위 방사성 폐기물 처분장의 경우 폐기물의 방사성 붕괴에 의해 열이 발생되며, 암반을 통한 열전달에 의해 처분장 주변 환경이 변화됨으로써 처분장의 안전성에 영향을 미칠 수 있다. 그러므로 지하 처분장 대기의 열전달계수를 결정하는 것은 매우 중요하다. 이에 본 연구에서는 Korea Atomic Energy Research Institute Underground Research Tunnel (KURT)에서 내부 환경 인자들의 측정을 통해 강제대류시 열전달계수를 산정하였다. 실험을 위해 KURT 내 히터구간의 막장 벽면에는 길이 2 m, 용량 5 kw의 히터를 삽입하여 암반 내부를 $90^{\circ}C$로 가열하였고, 외부와 연결된 급기용 팬에 의해 신선한 공기를 공급하였다. 연구결과, 외부공기 공급 후 히터구간 대기의 기류속도는 평균 0.81 m/s로 측정되었고 레이놀즈수는 약 310,000~340,000의 값을 나타냈다. 그리고 강제대류조건에서 히터구간 내 계절별 열전달계수는 각각 여름철 $7.68\;W/m^2{\cdot}K$와 겨울철 $7.24\;W/m^2{\cdot}K$의 수치를 나타냈다.

SLAM기반 확률적 필터 알고리즘을 이용한 스마트 식물 제어 시스템 개발 (Development of Smart Garden Control System Using Probabilistic Filter Algorithm Based on SLAM)

  • 이양원
    • 한국전자통신학회논문지
    • /
    • 제12권3호
    • /
    • pp.465-470
    • /
    • 2017
  • 본 논문은 가전로봇 항해 성능 개선을 위하여 사용된 SLAM기반 확률적 필터 개선 알고리즘을 이용하여 최근 각광받고 있는 사물인터넷과 융합한 아파트 실내나 베란다에서 사용이 가능한 스마트 가든 시스템을 설계 구현하였다. 이를 위하여 개방하드웨어 제어기인 아두이노와 센서들을 이용하였고, 세 가지 무선방식(블루투스, 이더넷, 와이파이)으로 자동 급수 및 조명, 성장모니터링을 제어 및 관찰이 가능하도록 설계하였다. 본 시스템은 이미 많은 활용이 되고 있는 기존의 식물공장과 같은 대규모 재배 시스템이 아니고 아파트와 같은 실내에서 사용 할 수 있도록 하기 위하여 개발되었다. 개발된 시스템은 스마트폰 앱을 통한 제어는 물론 토양센서, 조도센서, 습도센서, 온도센서 등을 이용하여 환경데이터를 수집하고 수집된 데이터를 분석하여 급수펌프와 LED 램프, 온도를 제어하기 위한 환기팬 등의 기능으로 구성되었다. 무선 원격제어 방법으로는 블루투스, 이더넷, 와이파이 등이 모두 가능하도록 구현 하였다. 따라서 사용자가 집안에 없을 때 원격 제어 및 모니터링이 가능하도록 설계하였다.

공사 중 환기덕트 누풍 최소화를 위한 접속부 개발 및 성능평가 연구 (A study on the development and performance evaluation of duct coupling for the minimized leakage of temporary ventilation duct)

  • 조형제;전규명;민대기;김종원;백종훈
    • 한국터널지하공간학회 논문집
    • /
    • 제20권1호
    • /
    • pp.145-160
    • /
    • 2018
  • 초장대 해저터널은 환기를 위한 연직갱 또는 경사갱 설치에 공간적으로 많은 제한을 받게 되므로 일부 인공섬을 건설하여 환기를 수행할 필요가 있다. 그러나 인공섬 설치는 건설의 어려움뿐만 아니라 건설비용이 증가하게 되므로 인공섬 설치를 최소화할 필요가 있다. 이에 따라 환기거리가 증가하여 누풍에 의한 공급 풍량이 커지게 되면, 공사 중 환기를 위한 덕트 설치가 불가능해지거나 팬 정압 및 동력이 상당히 증가하게 된다. 따라서 초장대 해저터널을 건설하기 위해서는 이러한 현실적인 문제를 극복하고 시공 중 터널 내 환경을 쾌적한 상태로 유지할 수 있는 기술력이 필요하다. 선행 연구에서 우리는 누풍이 이 문제들을 해결하는 핵심 인자이며 실험 결과 새로운 접속방식의 누풍율은 대략 $1.46mm^2/m^2$임을 밝혔다(Jo et al., 2017). 본 연구에서는 새로운 접속방식이 적용된 시제품의 누풍율 측정 결과를 제시하고 기존 접속방식의 누풍 성능 개선을 위해 덕트 내부에 연질막 적용시의 누풍 성능 개선을 실험적으로 분석하였다.

흡수성 Biofilter 를 이용한 농촌 소규모 오수처리 시설의 성능 (Performance for a small on-site wastewater treatment system using the absorbent biofilter in rural areas)

  • 권순국;윤춘경
    • 한국환경농학회지
    • /
    • 제18권4호
    • /
    • pp.310-315
    • /
    • 1999
  • 본 연구에서는 생물막법의 일종인 흡수성 Biofilter 시스템(ABS)을 설치하여 14개월의 실험기간 동안 건국대 농생대 구내의 염기성 부패조로부터 유입수를 3가지 수리부하율로 처리하여 시험하였다. 모니터링 결과에 의하면 ABS는 평균농도 $BOD_5=6.2mg/l$, TSS=4.4mg/l 이라는 아주 낮은 유기성 유출수를 연속적으로 발생시킬 수 있음이 확인되었다. 이러한 저농도 유출수는 현재 우리나라 오분법의 특정지구(상수원 보호구역)에 대한 방류수 기준($BOD_5=10mg/l$, TSS=10mg/l)에도 훨씬 못 미치는 양호한 농도로서 ABS의 우수한 유기성오수 처리성능이 입증되었다. 특히 유출수내의 TSS 농도가 지극히 낮아서 슬러지의 발생이 거의 없으므로 침전조를 생략할 수 있어 설치비용이 저렴해지고, 유지관리가 단순한 장점을 지니고 있음을 알 수 있었다. 그러나 ABS시설이 농촌에 널리 보급되어 실용적인 시스템이 되기 위해서는 앞으로 T - N과 T- P의 처리효율 향상 방안, 겨울철에 대한 Biofilter탱크내 임계온도 유지문제, 광역모니터링 및 신속보수 유지관리체계 확립에 대한 계속적인 연구가 필요하다. 이러한 문제점만 어느정도 해결된다면 ABS는 우리나라 농촌의 소규모 현장 오수처리시설로서 앞으로 미래가 밝은 차세대형 시스템이 될 것으로 확신한다.

  • PDF