• Title/Summary/Keyword: Air supply fan

Search Result 71, Processing Time 0.023 seconds

Comparison of the PMV and $CO_2$ concentration Characteristic in the Lecture Room with a Different Airflow rate of the Ventilation System and Heating System for heating season (강의실에서 환기시스템과 난방시스템의 풍량에 따른 PMV와 $CO_2$ 농도 특성 비교)

  • Han, Chang-Woo;Noh, Kwang-Chul;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.411-416
    • /
    • 2006
  • In this paper, we performed the experimental and numerical study on the thermal comfort(TC) and indoor air quality(IAQ) in the lecture room with a different airflow rate of the ventilation system and heating system for heating season. Through the experimental results, we found out that there was considerably difference of the PMV but there was little difference of $CO_2$ concentration with a different heating system. From a numerical results, the best operating condition was that discharge airflow rate of SAC is 29 CMM and supply airflow rate of the ventilation system is 1,200 CMH from a viewpoint of TC and IAQ.

  • PDF

Estimation of Potential Supply of Offset from Household Electric Appliances (가정용 전자기기의 잠재 상쇄 공급량 추정)

  • Jin, Hyun Joung;Kim, Jeong In;You, Eun Young;Park, Seo Hwa
    • Environmental and Resource Economics Review
    • /
    • v.24 no.3
    • /
    • pp.463-488
    • /
    • 2015
  • A more detailed design of offset system is needed according to the emission trading system started in 2015. This study aims to estimate the supply of potential offset that can be secured by expanding high-efficiency household electric appliances. The target commodities for analysis are three different householding electric appliances: TV, washing machine, electric fan, refrigerator and air conditioner. By using the ARDL model, we estimated the coefficients of diffusion of these high-efficiency appliances from 2016 to 2022. Then, the potential supply of offset was drawn by calculating the amount of electricity saving by efficiency improvement and by applying the rates of carbon exchange. Supposing that the electricity savings rates of high-efficiency appliances are each 10% and 20%, the accumulated carbon decrement in 2022 was respectively $361,899CO_2t$ and $723,797CO_2t$. The appliance that showed the biggest carbon decrement was air conditioner, and the second biggest was refrigerator and the next was TV, followed by washing machine, electric fan.

Mechanism Improvement of the Heat Exchanger for the Thermal Efficiency Increase of Hot Air Heater (온풍난방기의 열효율 증대를 위한 열교환기 구조개선)

  • Kang, Geum-Choon;Kang, Yoen-Ku;Ryou, Young-Sun;Kim, Young-Joong;Lee, Si-Young;Paek, Yee
    • Journal of Biosystems Engineering
    • /
    • v.34 no.5
    • /
    • pp.363-370
    • /
    • 2009
  • Hot air heater with light oil combustion is used as the most common heater for greenhouse heating in the winter season. Hot air heaters of 256,246 units have been supplied as main greenhouse heating equipment until 2008 and greenhouse heating cost has reached to 620 billions won in Korea. In order to improve the thermal efficiency of the hot air heater and to reduce the expenses for greenhouse heating, prototype hot air heater was manufactured and tested in this experiment. The heat exchanger of tested prototype hot air heater was circular and hexagonal pipe type and inline and stagger arrangement type. Capacity of the heating was 43,062 kJ/h and total heat transfer area of the heat exchanger was $10.728\;m^2$. According to the performance test, it could supply heat of 38,240 to 35,100 kJ/h depending on the fan motor speed of 1,740~1,220 rpm, respectively. Thermal efficiency of hot air heater was 87.0% to 80.8% in the same conditions. As a result, thermal efficiency of hot air heater with hexagonal pipe-stagger arrangement heat exchanger developed in this study was higher 10.2% than that of conventional hot air heater and heating energy saving rate of 14.3% increased.

A Numerical Analysis of Hydrogen Diffusion for Hydrogen Leakage from a Fuel Cell Vehicle in a Long Road Tunnel (장대터널에서 수소연료전지 차량의 수소 누출에 대한 수소 거동의 수치해석 연구)

  • Choi, Jongrak;Hur, Nahmkeon;Lee, Moonkyu;Chang, Hyungjin;Lee, Kwangbum;Yong, Geejoong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.6
    • /
    • pp.588-597
    • /
    • 2012
  • In the present study, the dispersion characteristics of hydrogen leakage from a Fuel Cell Vehicle (FCV) were analyzed by numerical simulation in order to assess the risk of a hydrogen leakage incident in a long road tunnel. In order to implement the worst case of hydrogen leakage, the FCV was located at the center of a tunnel, and hydrogen was completely discharged within 63 seconds. The Leakage velocity of hydrogen was adopted sub-sonic speed because that the assumption of the blockage effect of secondary device inside a vehicle. The temporal and spatial evaluation of the hydrogen concentration as well as the flammable region in a road tunnel was reported according to change of ventilation operating conditions. The hydrogen was blended by supply air form a ventilation fan, however, the hydrogen was discharged to outside in the exhaust air. It is observed that the efficiency way to eliminate of hydrogen is supply air operating condition under the hazardous hydrogen leaking incident. The present numerical analysis can be provided useful information of ventilation under the hydrogen leaking situation.

A Study on the Ventilation Efficiency of Apartment Housing Bathroom Based on the Flexible Installation Method of Exhaust Fan. (공동주택 욕실 배기팬의 플랙시블 덕트 시공상태에 따른 환기효율에 관한 연구)

  • Lee Kwang Myung;Ham Jin Sik
    • Journal of the Korean housing association
    • /
    • v.16 no.1
    • /
    • pp.73-79
    • /
    • 2005
  • The ventilation efficiency of apartment housing bathroom has been measured by the flexible's diameter, length, and installation format to the exhaust In. The gas density attenuation method of Tracer Gas Method has been specifically utilized for this measurement. Full size mock-up of apartment housing bathroom, which was approximately $100 m^2$ in size, has been established for the ventilation emciency measurement. In addition, the ventilation efficiency has been studied by the possibility of air-supply In. The diameters of flexible are 100 mm, 125 mm, and 150mm. It also have the length of 1.0m, and 1.5 m. The installation formats are I shape, L shape, and S shape. As a result of this measurement, the flexible which has the highest ventilation efficiency was the one has bigger diameter, short in length, and I shape installation format.

Building Energy Management System Coupling with Renewable Energy System

  • Oh, Jin-Seok
    • Journal of Navigation and Port Research
    • /
    • v.34 no.9
    • /
    • pp.705-709
    • /
    • 2010
  • Buildings nowadays are increasingly expected to need higher and more economic performance requirements. Energy consumption in buildings accounts for over 30% of total energy use. The Building Energy Management System (BEMS) and renewable energy (RE) technologies are considered as a potential measure to improve energy efficiency and reduce use of grid-power. It is, however, a challenge to utilise the intermittent energy supply of RE in building energy systems. This paper presents an experimental study on a RE-embedded BEMS. A control algorithm for the RE-embedded BEMS was designed to maximise the utilisation of RE and eventually to reduce electrical utility bill. The proposed system is tested at a laboratorial chamber with an air conditioner, fan and heater. The contribution of RE in building energy system is discussed to this end.

Heating and Cooling System for Utilization of Surplus Air Thermal Energy in Greenhouse and its Control Logic

  • Yang, Seung-Hwan;Lee, Chun-Gu;Lee, Won-Kyu;Ashtiani, Alireza Araghi;Kim, Joon-Yong;Lee, Sang-Deok;Rhee, Joong-Yong
    • Journal of Biosystems Engineering
    • /
    • v.37 no.1
    • /
    • pp.19-27
    • /
    • 2012
  • Purpose: Utilizing air thermal energy during over-heated time in the greenhouse is a necessary component to save greenhouse heating costs for nighttime. However, there is no practical way to implement the related principles. Methods: In this study, a heating and cooling system which utilizes the surplus air thermal energy in a greenhouse was developed. Available air thermal energy and heating load for this experimental glasshouse were estimated based on temperature conditions of the plant growth and weather data. Results: Estimated values were 400 MJ/day for maximum surplus air thermal energy and 340 MJ/day for maximum heating energy which were target values of the design as well. The system consists of a heat pump, fan-coil units and heat storage tanks which are divided into low and high temperature tanks. Moreover, a new control logic was developed for surplus air thermal energy utilization. Conclusions: This paper explains the details of conceptual design process of the system. Results of test operations showed that the developed system performed the recovery and supply of the thermal energy according to design purposes.

A transient CFD simulation of ventilation system operation for smoke control in a subway station equipped with a Platform Screen Door(PSD) when a train under fire is approaching the station (화재열차의 역사 접근 시 PSD가 설치된 역사 제연을 위한 환기장치 운전 비정상상태 해석)

  • Shin, Kyu-Ho;Hur, Nahm-Keon;Won, Chan-Shik
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.269-272
    • /
    • 2006
  • The heat and smoke which generated by subway under fire is one of the most harmful factor in air tighten underground station. To prevent this, Trackway Exhaust System(TES) can be used. The heat released from the train running in the tunnel raises the temperature at the platform and the trackway, and thus proper ventilation system is required for comfortable underground environment. When the fire is occurred, TES is operated as smoke exhaust mode from normal ventilation mode. In the present study, the subway station which is one of the line number 9 in Seoul subway is modeled, and fired situation is simulated with several ventilation mode of ventilation system in trackway. For this simulation whole station is modeled. Non steady state 3D simulation which considered train under fire is entering to the station is performed. Temperature and smoke distribution in platform and trackway are compared. To represent heat by fire, heat flux was given to the fired carriage, also to describe smoke by fire, concentration of CO is represented. As the result of present study, temperature and smoke distribution is different as the method of ventilation in trackway and platform is changed. In over side of trackway, the fan must be operated as exhaust mode for efficient elimination of heat and smoke, and supply mode of fan operation in under side shows better distribution of heat and smoke. The ventilation system which is changed from ventilation mode to exhaust mode can be applied to control heat and smoke under fire.

  • PDF

The Performance Evaluation of the Exhaust Stack used in High Riser Public House (초고층 공동주택 국소배기용 입상덕트의 배기성능평가)

  • Kwon, Yong-Il;Kim, Ung-Yong;Shin, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.3
    • /
    • pp.60-67
    • /
    • 2014
  • Exhaust system used in toilet and cooking place of high riser public house is roof fan of two basic types : natural roof ventilator and natural/forced roof ventilator. Natural/forced roof ventilator has a motor in the rotary shaft. There are many high riser public house in Korea. These buildings were not viewed as being major contributors to exhaust pollutants producted in indoor. It was because many engineers thought that exhaust in high riser building depend on stack effect. This study investigates on stack pressure determined by exterior pressure and the difference pressure control in exhaust stack used in high riser public house. This paper focuses mainly on the effect of the time interval for power supply of motor installed in roof fan with function of natural wind velocity and of exhaust air volume of toilet. It is observed there are higher exhaust efficiency than the existing natural roof ventilator.

A Study on Nitrification and Denitrification in Biofilter & Sulfur- Limestone Single Stream Process (바이오필터와 황-석회석을 이용한 단일흐름 공정에서의 질산화와 탈질 연구)

  • Kim, Tae-Kyu
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.469-477
    • /
    • 2006
  • When denitrification was connected with a single stream process by using biofilter and sulfur-limestone, it was found that such connection enabled highly efficient nitrification without special unit operation of microorganisms or injection of external carbon sources which is being shown in general biological treatment processes. It was observed that in the trickling filter bed, decomposition of organic substances and highly efficient nitrification by both the forced pressure feed trickling and the air fan were simultaneously done. In the denitrification tank where sulfur-limestone was mixed at a certain ratio, limestone was used by autotrophic microorganisms as a source of supply for alkalinity, and nitrate $NO_{3}^{-}$-N was denitrified into nitrogen gas. And in the sulfur-limestone autotrophic denitrification, $NO_{3}^{-}-N\;or\;NO_{2}^{-}-N$ was denitrified as a sulfur compound in reduction state was oxidized into a final output of $SO_{4}^{-2}$. The mean concentration of the discharge water was 8.6 mg/l for T-N and 0.8 mg/l for T-P, respectively, and their mean treatment efficiency was 79.2% and 80.8%, respectively. Implementing highly efficient denitrification without injection of an external organic carbon source or internal return, it is concluded that the proposed process is suitable for a sewerage in a small village with the merits of low power consumption and easy maintenance.