• 제목/요약/키워드: Air supply fan

검색결과 71건 처리시간 0.026초

HVAC 시스템의 중복고장 검출을 위한 실험적 연구 (An Experimental Study on Multi-Fault Detection and Diagnosis Analysis of HVAC System)

  • 조성환;홍영주;양훈철;안병천
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.932-941
    • /
    • 2004
  • The objective of this study is to detect the multi-fault of HVAC system using a new pattern classification technique. To classify the effect of single-fault in determining the pattern, supply air temperature, OA-damper, supply fan, and air flowrate were chosen as experimental parameters. The combination of supply temperature, flow rate, supply fan and OA-damper were chosen as multi-fault conditions. Three kinds of patterns were introduced in the analysis of multi-fault problem. To solve multi-fault problem, the new pattern classification technique using residual ratio analysis was introduced to detect the multi-fault as well as single-fault. The residual ratio could diagnose single-fault or multi-fault into several patterns.

압전 액추에이터를 이용한 DMFC의 공기 공급 시스템 (Air Supplying System for DMFC using Piezo Actuators)

  • 홍철호;김동진;윤효진
    • 한국산학기술학회논문지
    • /
    • 제11권5호
    • /
    • pp.1585-1591
    • /
    • 2010
  • DMFC는 산소를 반응물질로 사용하기 때문에 캐소드 전극이 외부 공기와 직접 접촉해야 한다. 그러나 휴대기기에 사용하는 경우에 사용자의 신체에 의해 공기의 흡입구가 가려져 산소공급이 되지 않는 현상이 발생할 수 있다. DMFC에 공기를 공급하기 위해 냉각팬을 사용하는데 냉각팬은 유로의 압력 손실 및 변동에 따라 출력의 변동이 심하다. 본 논문에서는 냉각팬의 문제점을 해결하기 위해 압전 액추에이터를 이용하여 공기 공급 시스템을 설계하였다. 설계된 공기 공급 시스템의 성능을 평가하기 위해 DMFC 평가 시스템을 구현하였고, 구현된 시스템을 통해 MP3 플레이어를 동작 시켰다.

ESPI를 이용한 에어콘용 시로코팬의 신뢰성평가

  • 김경석;강기수;양승필
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2002년도 정기학술대회
    • /
    • pp.253-260
    • /
    • 2002
  • This paper propose Electronic Speckle Pattern Interferometry(ESPI) for reliability evaluation of electronic device. Especially, vibration problem in a fan of air conditioner, motor of washing machine and etc. is important factor to design the devices. However, it is difficult to apply previous method, accelerometer to the devices with lightweight and complex geometry. ESPI, non-contact measurement technique is applied for vibration analysis of a sirocco fan inside air conditioner. Vibration mode shapes, natural frequency and the range of the frequency are decided and compared with that of FEM analysis. In mechanical deign of new product, ESPI is able to supply effective design information.

  • PDF

초고층건물 계단실 단독 급기가압 제연조건이 연돌효과에 미치는 영향 (The Influence of Stairway Pressurization Conditions on the Stack Effect in Super-tall Buildings)

  • 박용환;김범규
    • 한국화재소방학회논문지
    • /
    • 제24권4호
    • /
    • pp.109-115
    • /
    • 2010
  • 중앙코어형 80층 초고층건물에서 평상시 동절기 연돌효과에 따른 최대차압은 약 75Pa로 외부 풍속이 없을 시에는 별 문제가 되지 않았으며, 화재로 계단실 단독 급기가압 시에는 급기가압 팬의 위치에 따라 급기 초기에 최대 약 225pa의 차압이 발생할 수 있으며 이를 해소하기 위한 적절한 과압배출장치나 대책이 필요하였다. 급기 송풍기의 위치에 따른 단독하부급기 방식이 최대차압의 크기와 분포 특성 및 최소설계차압 유지를 위한 소요풍량 면에서 가장 유리하였으며, 단독 상부급기방식은 소요급기풍량이나 차압분포 특성을 고려할 때 우리나라 특성에는 가장 적합하지 않는 것으로 나타났다. 차가운 외기 급기로 인해 계단실의 온도가 점차 하강하게 되면 계단실 연돌효과의 감소로 인해 소요풍량이 줄어들었으며 고층부에서의 차압은 줄어드는 반면 저층부에서의 차압이 크게 증가하는 양상으로 변화하는 것으로 나타났다.

CFD를 이용한 선박 기관실 공기 공급용 팬 입구 형상에 따른 성능 비교 연구 (The Study of Performance Comparison on the Inlet Shapes of Fan for Engine Room of Ship Using CFD)

  • 권도훈;홍윤균;구성우;정은수
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2011년도 특별논문집
    • /
    • pp.25-31
    • /
    • 2011
  • The performance of fan for engine room of ship is absolutely important when it take into consideration work efficiency, work condition, and the performance of various equipments. Fan performance test should be carried out during sea trial to satisfy owner's requirement as above mentioned. We have considered various values to affect fan test result. In here, various values are to be silencer, fan inlet shape, and arrangement of fan room. In general, the shapes of fan inlet is overall circular type because of the shapes of axial fan. So, all vessels built at SHI have been applied fan inlet of circular type. And now, in order to reduce sound of noise from supply fan, big silencer often has been installed at high value vessels. In this case, the capacity of supplied air can be insufficient due to silencer which is an obstructer about air flow. In this paper, we have studied the performance of fan through comparison between a circular shape and a square shape of fan inlet. We also compare with CFD results and experimental results.

  • PDF

공동주택 주방의 급ㆍ배기효율을 고려한 기계환기 설계에 관한 연구 (A Study on the Mechanical Ventilation Design that Consider Supply and Exhaust Efficiency of the Apartment House Kitchen)

  • 함진식
    • 한국주거학회논문집
    • /
    • 제15권3호
    • /
    • pp.101-108
    • /
    • 2004
  • To find more efficient exhaust effect, air curtain of upward or downward trend in gas table and left or right side of range hood were made. As result that film vapor from range hood lower part by digital camera, the air current change by moving existence and nonexistence of exhaust fan and direction of air curtain were known. Under all experiment condition, upward air curtain superior exhaust performance.

소형 PEM 연료전지 스택의 제어 알고리즘 개발 (Development of the Control Algorithm for the Small PEM Fuel Cell Stack)

  • 김태훈;최우진
    • 전력전자학회논문지
    • /
    • 제15권2호
    • /
    • pp.134-141
    • /
    • 2010
  • 소형 PEM (Proton Exchange Membrane) 연료전지 시스템은 가습이 필요치 않아 상용화의 가능성이 크지만 그 제어 방법은 뚜렷하게 정립되어 있지 않다. 따라서 본 논문에서는 소형 PEM 연료전지 시스템의 제어를 위해 이중 루프 구조의 제어방식을 정립하고 DSP (Digital Signal Processor)를 이용하여 구현한다. 일반적으로 연료전지 시스템에서 제어의 핵심 요소는 크게 공기와 수소의 공급, 스택 내부의 수분 관리, 스택의 온도 관리로 나뉜다. 별도의 가습이 없이 공랭식으로 구동되는 소형 PEM 연료전지 스택의 제어에 있어서 팬은 스택의 공기 공급과 열관리 및 수분관리를 위한 핵심적인 역할을 하며, 퍼지밸브는 스택 내부의 잉여수분을 배출한다. 제안된 방식은 이중 제어루프를 이용한 팬의 제어를 통해 팬의 과도응답을 빠르게 하여 공기의 공급 속도를 개선시키며, 연료전지 스택의 전압변화를 피드백 하여 보상해줌으로써 연료전지가 부하변동에 대해 신속한 응답 특성을 갖도록 하였다. 제안된 방법의 유용함은 60W급 소형 PEM 연료전지 시스템의 실험과 이를 이용한 노트북 컴퓨터의 구동을 통해 검증된다.

전산유체역학을 이용한 단일 송풍기가 적용된 공냉식 연소설비의 효율개선 (Enhancement of combustion efficiency of a air-cooled combustor system with single F.D. Fan Using CFD)

  • 김민철;손병현;이재정;박흥석
    • 한국산학기술학회논문지
    • /
    • 제22권6호
    • /
    • pp.460-468
    • /
    • 2021
  • 본 연구는 multi fan 방식의 "공랭식 연소설비"의 공정관리상의 문제점을 single F.D. fan 으로 대체하여 개선시키기 위해 CFD 진행하였고, 연소로 내 유동조건 변화를 분석하여 문제점을 확인하였다. 이를 개선하기 위해 연소공기 주입구조를 변경하였고, 구조 변화에 따른 연소효율 개선을 수치해석으로 평가하였다. 또한 실제 연소설비에 수치해석결과를 반영하여 구조개선을 한 후 개선 전·후의 연소효율을 실험적으로 측정하였다. 먼저 기존 Single F.D fan 이 적용된 연소설비에 대한 수치해석을 통해, 2개의 유로로 공급되는 연소공기가 각 유로의 마찰력 차이와 압력의 변화로 인해 연소로 내에서 공급비율이 불규칙하게 되어 선회방식의 연소조건을 위한 축 형태의 난류형성이 어려움을 확인하였다. 이를 개선하기 위해서 연소로에 주입하는 공기 공급 방식을 두 가지로 나누어 수치해석을 하였다. 첫 번째 방식은 연소공기를 외벽에서 180 ~ 360° 회전 후 예열된 연소공기가 주입되는 구조에 대하여 검토하였고, 두 번째는 연소로 내에는 선회할 수 있는 베인(vane) 구조를 적용하여 연소로 밖에서 1차 열교환 후 연소로 내부에 접선방향으로 연소공기가 주입되는 구조에 대하여 검토하였다. 그 결과, single F.D. fan을 가진 공랭식 연소로에 선회방식으로 공기를 주입할 경우, 연소로 외벽의 냉각과 연소로 내부의 완전혼합 유지를 위해 이중 냉각벽을 가지는 덕트 구조를 적용하는 것이 연소조건을 최적화하는데 바람직한 것으로 나타났으며, 실제 운영중인 설비에 적용하여 개선 전·후의 연소효율을 비교한 결과 연소효율이 개선되는 것을 확인할 수 있었다.

에너지 절약용 냉방사이클 (Cooling Cycle for Energy Saving)

  • 이흥주;김용구
    • 설비공학논문집
    • /
    • 제1권2호
    • /
    • pp.116-127
    • /
    • 1989
  • Research on reheating cooling cycle and its practical application have been made to prevent unequalized distribution of temperature and humidity of room due to lack of supply air volume and dewdrops on supply diffusers to be taken place as a result of lower temperature of supply air than that of dew point of room air in cooling cycle of constant air volume, single duct, single zone and draw-through fan type. In view of the fact that human body is insensitive to humidity, it is possible not only to construct the complete non-reheating cooling cycle by increasing the humidity point allowable with the deduction of occupant's sense of pleasantness minimizing, but also to get cooling cycle decreasing the reheating quantity if the humidity exceeds the point allowable. In addition, it is possible to save maximum 8% in electric energy for cooling in cooling system by constructing non-reheating cooling cycle instead of reheating cooling cycle and by increasing the relative humidity of room from 50% to 65% in case efficiency and air pressure of cooling system are low. It is also possible to get an optimum cooling cycle by determining the room humidity in consideration of pleasantness of occupants and conservation rate of electric energy if the cooling capacity, efficiency and total pressure of cooling equipment are fixed.

  • PDF