• 제목/요약/키워드: Air stripping

검색결과 66건 처리시간 0.028초

후처리를 이용한 $CO_2$ 포집이 화력 발전설비 성능에 미치는 영향 해석 (Analysis of the Influence of Post-Combustion $CO_2$ Capture on the Performance of Fossil Power Plants)

  • 탁상현;김동섭;장영수;이대영;김민성
    • 설비공학논문집
    • /
    • 제22권8호
    • /
    • pp.545-552
    • /
    • 2010
  • Research and development efforts to reduce $CO_2$ emission are in progress to cope with global warming. $CO_2$ emission from fossil fuel fired power plants is a major greenhouse gas source and the post-combustion $CO_2$ capture is considered as a short or medium term option to reduce $CO_2$ emissions. In this study, the application of the post-combustion $CO_2$ capture system, which is based on chemical absorption and stripping processes, to typical fossil fuel fired power plants was investigated. A coal fired plant and a natural gas fired combined cycle plant were selected. Performance of the MEA-based $CO_2$ capture system combined with power plants was analyzed and overall plant performance including the energy consumption of the $CO_2$ capture process was investigated.

조기강도 발현형 콘크리트의 현장 적용성 연구 (A Site Application of the Revealing High Early Strength Concrete)

  • 김규동;이승훈;손유신;김한준
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.560-563
    • /
    • 2004
  • This study reports the site application of concrete using AE Water Reducing Agent of Early-Strength Type. According to the lab test results, we have made plans of batch plant pilot test, and we have analyzed the erly aged compressive strength and workability of the concrete. We applied the early-strength development concrete to the construction site. We accomplished the slump test in order to evaluate the workablity and air contents, we made site curing mold to evaluate the early strength of members. As a result, we judgeed the superior property of early strength development of the concrete, and thought that we can reduce the time of form stripping more $40\%$ than ordinary strength concrete. We thought that we can reduce the term of works and finally we can accomplish the economical construction.

  • PDF

혼화제를 이용한 조강콘크리트 배합설계에 관한 연구 (A Study on the Mix Design of Early Strength Concrete using Admixture)

  • 박영신;남성우;박재명
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.69-72
    • /
    • 2005
  • In this study, it is contents to application on AE water reducing admixture for high early strength, which reduce to construction period for cost down in construction. In experiment result on the kinds of AE water reducing admixture for concrete strength promotion, when passed 60 minutes, while it was happened on lignin and naphthalene system about $30\∼35\%$ that loss related to slump, slump flow and air, but happened about $8\∼10\%$ on polycarboxylic system. And the result of compressive strength tests, when 32 hours passed in polycarboxylic system than lignin and naphthalene system, was showing an increase of 10$\%$. Accordingly, concrete properties was measured to condition change by the addition amount and curing temperature of polycarboxylic system. The required curing temperature to gain 5MPa of compressive strength, which is capable of side form stripping, must keep more than smallest 12. 5$^{circ}C$ when polycarboxylic system is used. As a result, AE water reducing admixture of polycarboxylic system may apply effectively to high early strength concrete

  • PDF

반응조의 물리적 인자와 알칼리도가 암모니아 탈기에 미치는 영향에 관한 연구 (Effect of the Physical Parameters and Alkalinity in the Ammonia Stripping)

  • 안주석;임지혜;백예지;정태영;정형근
    • 대한환경공학회지
    • /
    • 제33권8호
    • /
    • pp.583-590
    • /
    • 2011
  • 공기 폭기법을 통해 암모니아를 제거함에 있어, 반응조의 물리적 인자(폭기 깊이, 공기 방울 크기, 표면적)와 알칼리도가 암모니아의 제거 속도에 미치는 영향을 평가하였다. 30 L/min의 공기를 6~53 cm의 폭기 깊이로 실험한 결과, 폭기 깊이는 암모니아 제거 속도에 영향을 미치지 않았다. pH가 10.0, 온도가 $30^{\circ}C$에서 암모니아의 제거 속도 상수와 표준편차는 각각 $0.175h^{-1}$, 0.004로 나타났다. 공기 방울의 크기 및 공기상과 접촉하는 수표면의 표면적은 제거 속도에 영향을 미치지 않았다. 폐수의 알칼리도는 암모니아 제거 속도에 간접적으로 영향을 미치는 것으로 나타났다. 이는 폭기에 의해 이산화탄소가 수용액에 용존되어 pH를 변화시킬 수 있기 때문인 것으로 예상된다. 매립지와 하수 종말 처리장에서 채취한 실제 폐수를 대상으로 암모니아 제거 속도를 살펴보았다. 하수 원수(pH = 7.1, alkalinity = 75 mg/L)의 경우, pH를 9.3으로 조절하여도 암모니아 제거 속도가 크게 증가하지 않았다. 그러나, 알칼리도가 높은 침출수 원수(pH = 8.0, alkalinity = 6,525 mg/L)는 초기 pH가 낮음에도 불구하고, 공기 폭기에 따른 pH 상승으로 인해 암모니아 제거 속도가 증가하는 경향을 나타냈다. 또한, 침출수 원수의 pH를 9.4로 조절한 경우, 하수 원수와 달리 공기 폭기에 따른 pH 저하가 나타나지 않아 암모니아 제거 속도가 유지 되었다.

가스상 TCE 처리를 위한 추출막 생물반응기의 수학적 모사

  • 김지석;김관수;장덕진
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 춘계학술발표대회
    • /
    • pp.370-373
    • /
    • 2000
  • In this work, an extractive membrane bioreactor containing coulture broth of Burkholderia cepacia G4 PR1 constitutively expressing the TCE-degrading enzyme, tolune-ortho-monooxygenase(TOM), was used for the degradation of TCE. The membrane bioreactor operates by seperating the TCE-containing waste gas from the aerated biomedium, by which the air-stripping of TCE without degradation was overcome that could occur in conventional aerobic biological treatments of TCE-contaminated waste gases. This was achieved by a silicone rubber membrane which was coiled around a perspex draft tube. TCE from the gas phase diffuses across the silicone rubber membrane into microbial culture broth that was continuously fed from a separate aerobic CSTR. Therefore, TCE degradation occured without the TCE being directly exposed to the aerating gas stream. Of the TCE supplied to the membrane bioreactor, 72.6% was biodegraded during the operation of this system. To construct a mathematical model for this system, parameters describing microbial growth kinetics on TCE were determined using a CSTR bioreactor. Else parameters used for numerical simulation were determined from either indepedent experiments or values reported in the literature. The model was compared with the experimental data, and there was a good agreement between the predicted and the measured TCE concentrations in the system. To achieve a higher treatment efficiency, various operating conditions were simulated as well.

  • PDF

아크릴섬유 폐수의 생물학적 질소제거공정의 개선 (Improvement of the Advanced Treatment for Nitrogen Removal of Acrylic Fiber Wastewater)

  • 이찬원;조인성;임경원
    • 한국환경과학회지
    • /
    • 제15권5호
    • /
    • pp.439-446
    • /
    • 2006
  • The effluent discharge standards of industrial wastewater has become more stringent since 2003. Many industrial wastewater treatment plants has been upgraded to advanced treatment facilities. There are high concentrations of nitrate(>200 mg/L) and ammonium(>50 mg/L) nitrogen in the acrylic fiber wastewater of H textile Co. Wastewater from acrylic fiber industry containing acrylonitrile, which may affect the subsequent biological treatment process. Manufacturing of acrylic fiber also produces shock loadings. Excessive acrylonitrile and polymer debris produced in the polymerization process was screened, coagulated with CaO and settled down. A preaeration system was added to treat this high pH effluent to remove volatile organic compound and ammonia nitrogen by the air stripping effect. it was found that nitrification rate was not sufficient in the Anoxic/Oxic(AO) process. One denitrification tank was converted to nitrification reactor to extend HRT of nitrification. Nitrification rate of ammonia nitrogen was promoted from 32% to 67% by this modification and effluent nitrogen concentration was well satisfied with the effluent standards since then.

반연속배양의 혼합균주에 의한 Benzene, Toluene 및 Phenol 혼합물 분해 (Biodegradation of Benzne,Toluene, and Phenol by a Mixed Culture in Semicontinuous Culture)

  • 오희목;김성빈;이창호;서현효;이문호;고영희;윤병대
    • 한국미생물·생명공학회지
    • /
    • 제22권4호
    • /
    • pp.415-422
    • /
    • 1994
  • The biodegradation of aromatic compounds by a mixed culture GE1 was investigated in an artificial wastewater containing 250 mg/l of benzene, toluene, and phenol in semicontinuous culture. In the control group (no strains) with an aeration rate of 75 ml/l/min, 37% of phenol and 83% of benzene were volatilized during early 24 hrs and toluene was disappeared from the medium within 12 hrs. The biodegradation of benzene and toluene was effective in SB (strains + biofilm) treatment, while phenol was degraded more quickly in SG (strains + glucose) treatment including glucose as an additional carbon source. aromatic compounds added at a concentration of 250 mg/l were completely removed by SG treatment after 16 hrs or 32 hrs, respectively. The removal rate of COD was high as much as 80 mg/l/h in SG treatment during early period, but COD revealed a stable value of 116~140 mg/l after 12 hrs caused by increased biomass. Therefore, it is concluded that the mixed GE1 could be used for the wastewater treatment including aromatic compounds such as benzene, toluene, and phenol.

  • PDF

우측이부를 포함한 전두피박이환자의 재이식 치험예 (A CASE REPORT OF TOTAL AVULSED SCALP WITH RIGHT TOTAL EAR)

  • 이열희;변기정;김신호
    • 대한치과의사협회지
    • /
    • 제15권2호
    • /
    • pp.115-120
    • /
    • 1977
  • Extensive avulsion of the scalp, or stripping of a large area of soft tissue from the skull, is a serious accidnet. The avulsed scalp is often injured otherwise, such as by crushing, tearing, or from multiple laceration. The surrounding skin may be devitalized. Replacement of the scalp is usually followed by necrosis and sloughing within a short time. In such instances, the outer table of the cranium may become sucessively exposed. dry, dead, and affected by osteomyelitis. Hence the securing of early healing to prevent these is of the utmost importance. The successful case of reimplantation of the completely avulsed scalp, which is exposured to air for about 14 hours, is reported, in which there was partial growth of hair afterwards. The avulsed scalp caused by her long hair being caught in a grain belt was contaminated with hairs & dust. Authors treated this 19-year old female patient by split thickness skin graft, intermediate skin graft, full thickness skin graft from her own avulsed scalp.

  • PDF

Field Studios of In-situ Aerobic Cometabolism of Chlorinated Aliphatic Hydrocarbons

  • Semprini, Lewts
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.3-4
    • /
    • 2004
  • Results will be presented from two field studies that evaluated the in-situ treatment of chlorinated aliphatic hydrocarbons (CAHs) using aerobic cometabolism. In the first study, a cometabolic air sparging (CAS) demonstration was conducted at McClellan Air Force Base (AFB), California, to treat chlorinated aliphatic hydrocarbons (CAHs) in groundwater using propane as the cometabolic substrate. A propane-biostimulated zone was sparged with a propane/air mixture and a control zone was sparged with air alone. Propane-utilizers were effectively stimulated in the saturated zone with repeated intermediate sparging of propane and air. Propane delivery, however, was not uniform, with propane mainly observed in down-gradient observation wells. Trichloroethene (TCE), cis-1, 2-dichloroethene (c-DCE), and dissolved oxygen (DO) concentration levels decreased in proportion with propane usage, with c-DCE decreasing more rapidly than TCE. The more rapid removal of c-DCE indicated biotransformation and not just physical removal by stripping. Propane utilization rates and rates of CAH removal slowed after three to four months of repeated propane additions, which coincided with tile depletion of nitrogen (as nitrate). Ammonia was then added to the propane/air mixture as a nitrogen source. After a six-month period between propane additions, rapid propane-utilization was observed. Nitrate was present due to groundwater flow into the treatment zone and/or by the oxidation of tile previously injected ammonia. In the propane-stimulated zone, c-DCE concentrations decreased below tile detection limit (1 $\mu$g/L), and TCE concentrations ranged from less than 5 $\mu$g/L to 30 $\mu$g/L, representing removals of 90 to 97%. In the air sparged control zone, TCE was removed at only two monitoring locations nearest the sparge-well, to concentrations of 15 $\mu$g/L and 60 $\mu$g/L. The responses indicate that stripping as well as biological treatment were responsible for the removal of contaminants in the biostimulated zone, with biostimulation enhancing removals to lower contaminant levels. As part of that study bacterial population shifts that occurred in the groundwater during CAS and air sparging control were evaluated by length heterogeneity polymerase chain reaction (LH-PCR) fragment analysis. The results showed that an organism(5) that had a fragment size of 385 base pairs (385 bp) was positively correlated with propane removal rates. The 385 bp fragment consisted of up to 83% of the total fragments in the analysis when propane removal rates peaked. A 16S rRNA clone library made from the bacteria sampled in propane sparged groundwater included clones of a TM7 division bacterium that had a 385bp LH-PCR fragment; no other bacterial species with this fragment size were detected. Both propane removal rates and the 385bp LH-PCR fragment decreased as nitrate levels in the groundwater decreased. In the second study the potential for bioaugmentation of a butane culture was evaluated in a series of field tests conducted at the Moffett Field Air Station in California. A butane-utilizing mixed culture that was effective in transforming 1, 1-dichloroethene (1, 1-DCE), 1, 1, 1-trichloroethane (1, 1, 1-TCA), and 1, 1-dichloroethane (1, 1-DCA) was added to the saturated zone at the test site. This mixture of contaminants was evaluated since they are often present as together as the result of 1, 1, 1-TCA contamination and the abiotic and biotic transformation of 1, 1, 1-TCA to 1, 1-DCE and 1, 1-DCA. Model simulations were performed prior to the initiation of the field study. The simulations were performed with a transport code that included processes for in-situ cometabolism, including microbial growth and decay, substrate and oxygen utilization, and the cometabolism of dual contaminants (1, 1-DCE and 1, 1, 1-TCA). Based on the results of detailed kinetic studies with the culture, cometabolic transformation kinetics were incorporated that butane mixed-inhibition on 1, 1-DCE and 1, 1, 1-TCA transformation, and competitive inhibition of 1, 1-DCE and 1, 1, 1-TCA on butane utilization. A transformation capacity term was also included in the model formation that results in cell loss due to contaminant transformation. Parameters for the model simulations were determined independently in kinetic studies with the butane-utilizing culture and through batch microcosm tests with groundwater and aquifer solids from the field test zone with the butane-utilizing culture added. In microcosm tests, the model simulated well the repetitive utilization of butane and cometabolism of 1.1, 1-TCA and 1, 1-DCE, as well as the transformation of 1, 1-DCE as it was repeatedly transformed at increased aqueous concentrations. Model simulations were then performed under the transport conditions of the field test to explore the effects of the bioaugmentation dose and the response of the system to tile biostimulation with alternating pulses of dissolved butane and oxygen in the presence of 1, 1-DCE (50 $\mu$g/L) and 1, 1, 1-TCA (250 $\mu$g/L). A uniform aquifer bioaugmentation dose of 0.5 mg/L of cells resulted in complete utilization of the butane 2-meters downgradient of the injection well within 200-hrs of bioaugmentation and butane addition. 1, 1-DCE was much more rapidly transformed than 1, 1, 1-TCA, and efficient 1, 1, 1-TCA removal occurred only after 1, 1-DCE and butane were decreased in concentration. The simulations demonstrated the strong inhibition of both 1, 1-DCE and butane on 1, 1, 1-TCA transformation, and the more rapid 1, 1-DCE transformation kinetics. Results of tile field demonstration indicated that bioaugmentation was successfully implemented; however it was difficult to maintain effective treatment for long periods of time (50 days or more). The demonstration showed that the bioaugmented experimental leg effectively transformed 1, 1-DCE and 1, 1-DCA, and was somewhat effective in transforming 1, 1, 1-TCA. The indigenous experimental leg treated in the same way as the bioaugmented leg was much less effective in treating the contaminant mixture. The best operating performance was achieved in the bioaugmented leg with about over 90%, 80%, 60 % removal for 1, 1-DCE, 1, 1-DCA, and 1, 1, 1-TCA, respectively. Molecular methods were used to track and enumerate the bioaugmented culture in the test zone. Real Time PCR analysis was used to on enumerate the bioaugmented culture. The results show higher numbers of the bioaugmented microorganisms were present in the treatment zone groundwater when the contaminants were being effective transformed. A decrease in these numbers was associated with a reduction in treatment performance. The results of the field tests indicated that although bioaugmentation can be successfully implemented, competition for the growth substrate (butane) by the indigenous microorganisms likely lead to the decrease in long-term performance.

  • PDF

304 및 430 스테인레스 강판의 산화 및 중성염 전해산세 거동 (Oxidation and Neutral Electrolytic Pickling Behavior of 304 and 430 Stainless Steels)

  • 김태수;박용택
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 제5회 압연심포지엄 신 시장 개척을 위한 압연기술
    • /
    • pp.285-293
    • /
    • 2004
  • Oxidation behavior of 304 and 430 stainless steel were studied using thin film X-ray analysis and glow discharge spectrum analysis (here-after GDS). The oxidation layer of 304 stainless steel was composed of $Cr_2O_3\;and\;FeCrO_4$ and its thickness was about $1.5{\mu}m$ after $1\~5$ minutes of annealing at $1120^{\circ}C$ open air. However, the oxidation layer of 430 stainless steels was mainly composed of $Cr_2O_3$ and its typical thickness was 0.5um after $1\~5$ minutes of annealing at $1000^{\circ}C$ open air. Electro-chemical analysis revealed that the descaling of oxidation layer could be activated by Fe, Cr dissolution from the matrix behind the oxidation layer at the current density of $5\~10ASD$ and by Fe, Cr-oxide dissolution from the oxidation layer at the current density over than 10ASD. Electrolytic stripping of 430 and 304 revealed the intial incubation period of descaling by oxygen evolving at low current density range such as $5\~10ASD$. However the dissolution of oxide layer was occurred when applying the anodic current of $10\~20ASD$ on 430 and 304 stainless steels. It was suggested that the electrolytic pickling of high Cr bearing stainless steel such as 430 and 304 seemed to be the more effective in the high current density range such as $10\~20ASD$ than the low current density range such as $5\~10ASD$.

  • PDF