• Title/Summary/Keyword: Air source

Search Result 2,258, Processing Time 0.028 seconds

An Experimental Study on the Heat Transfer Performance of an Air-Source Heat Pump Using a PCM Unit for Continuous Heating (PCM 유닛을 적용한 공기 열원 히트펌프의 연속난방 성능 특성에 관한 실험적 연구)

  • Chang, Min;Jung, Dong Il;Jung, Jong Ho;Kim, Yongchan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.537-543
    • /
    • 2015
  • Air-source heat pumps are widely used in winter as heating units due to their higher efficiency compared to electronic heaters or gas fired equipment. However, the air-source heat pump can cause discomfort during periodic defrosting operations. In this study, a PCM unit for continuous heating was adopted to solve this problem. The PCM unit consisted of a PCM, a heat exchanger, and control valves. It was installed between the outdoor and indoor units. The performance of the proposed system was measured during both defrosting and heating operations. The indoor unit showed an average leaving temperature of $26^{\circ}C$ after adopting the PCM unit for continuous heating during the defrosting operation.

Performance of Air Source Heat Pump with a Fiber Belt Heat Regeneration System (섬유벨트 열재생 시스템을 부착한 공기 열원 열펌프의 난방 성능 특성)

  • 유영선;장진택;김영중;강금춘;윤진하;이건중
    • Journal of Biosystems Engineering
    • /
    • v.25 no.5
    • /
    • pp.385-390
    • /
    • 2000
  • The heat pump is one of heating and cooling systems driven by electricity using natural energy as a heat source. The heat pump system was mainly adopted to a cooling system or a refrigeration system. In regions with a large amount of electricity, it is used as a heating system or a heating and cooling system of houses, buildings and agricultural facilities. During cold weather, air source heat pumps do not work well because of some technical problems, such as frosting on evaporator coil when outside air temperature is below -5$^{\circ}C$. In this research, the heat regenerative technology was employed to eliminate the frosting on evaporator coil and improve the COP of the heat pump system. This fiber belt heat regeneration system(FBHRS) has very simple structure consisting of a geared motor and a porous fiber belt passing through alternatively between cold and warm air duct. The laboratory test showed that the heat pump system with a FBHRS yielded an impressive COP higher than 3.5 at the outside air temperature of -7$^{\circ}C$ in heating mode.

  • PDF

Control of Heat Pump for Low Emission Diesel Engine (저공해 중소형 디젤차량 히트펌프 제어)

  • Park, Byung-Duck;Lee, Won-Suk;Won, Jong-Phil;Kwon, Sun-Ik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.4
    • /
    • pp.379-384
    • /
    • 2002
  • As automotive diesel engines adopt the direct injection method for a lower level of the exhaust emission and a higher fuel efficiency, the maximum temperature of engine coolant decreases. Consequently, the total available heat source from the engine coolant decreases over 35%. However, the heating source of air-conditioning system in automobiles depends on the hot engine coolant completely, so that it is nearly impossible to control air conditioning in heating season. Therefore, the present study has been carried out to develop the air conditioning system for the high efficient heat pump type using the HFC-134a. Especially, the air conditioning system of heating has been developed at a beginning stage, when it has low heat source from small and medium sized diesel recreation vehicles. To develop a control logic system for air conditioning system which is a heat pump type with a heat recovery exchanger, its cycle characteristics has been investigated according to the opening of LEV at a bench system.

  • PDF

Exopolysaccharide Production and Mycelial Growth in an Air-Lift Bioreactor Using Fomitopsis pinicola

  • Choi, Du-Bok;Maeng, Jeung-Moo;Ding, Ji-Lu;Cha, Wol-Suk
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.8
    • /
    • pp.1369-1378
    • /
    • 2007
  • For effective exopolysaccharide production and mycelial growth by a liquid culture of Fomitopsis pinicola in an air-lift bioreactor, the culture temperature, pH, carbon source, nitrogen source, and mineral source were initially investigated in a flask. The optimal temperature and pH for mycelial growth and exopolysaccharide production were $25^{\circ}C$ and 6.0, respectively. Among the various carbon sources tested, glucose was found to be the most suitable carbon source. In particular, the maximum mycelial growth and exopolysaccharide production were achieved in 4% glucose. The best nitrogen sources were yeast extract and malt extract. The optimal concentrations of yeast extract and malt extract were 0.5 and 0.1%, respectively. $K_2HPO_4\;and\;MgSO_4{\cdot}7H_2O$ were found to be the best mineral sources for mycelial growth and exopolysaccharide production. In order to investigate the effect of aeration on mycelial growth and exopolysaccharide production in an air-lift bioreactor, various aerations were tested for 8 days. The maximum mycelial growth and exopolysaccharide production were 7.9 g/l and 2.6 g/l, respectively, at 1.5 vvm of aeration. In addition, a batch culture in an air-lift bioreactor was carried out for 11 days under the optimal conditions. The maximum mycelial growth was 10.4 g/l, which was approximately 1.7-fold higher than that of basal medium. The exopolysaccharide production was increased with increased culture time. The maximum concentration of exopolysaccharide was 4.4 g/l, which was about 3.3-fold higher than that of basal medium. These results indicate that exopolysaccharide production increased in parallel with the growth of mycelium, and also show that product formation is associated with mycelial growth. The developed model in an air-lift bioreactor showed good agreement with experimental data and simulated results on mycelial growth and exopolysaccharide production in the culture of F. pinicola.

Preliminary Source Apportionment of Ambient VOCs Measured in Seoul Metropolitan Area by Positive Matrix Factorization (PMF를 이용한 수도권지역 VOCs의 배출원 추정)

  • Han J. S.;Moon K. J.;Kim R. H.;Shin S. A.;Hong Y. D.;Jung I. R.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.1
    • /
    • pp.85-97
    • /
    • 2006
  • The PAMS data collected at four sites in Seoul metropolitan area in 2004 were analyzed using the positive matrix factorization (PMF) technique, in order to identify the possible sources and estimate their contributions to ambient VOCs. Ten sources were then resolved at Jeongdong, Bulgwang, Yangpyeong, and Seokmo, including vehicle exhaust, LPG vehicle, petroleum evaporation, coating, solvent, asphalt, LNG, Industry & heating, open burning, and biogenic source. The PMF analysis results showed that vehicle exhaust commonly contributed the largest portion of the predicted total VOCs mass concentration, more than $30\%$ at four sites. The contribution of other resolved sources were significantly different according to the characteristics of site location. In the case of Jeongdong and bulgwang located in urban area, various anthropogenic sources such as coating, solvent, asphalt, residual LPG, and petroleum evaporation contributed about $40\%$ of total VOCs mass. On the other hand, at yangpyeong and Seokmo located in rural and remote area, the portion of these anthropogenic sources was reduced to less than $30\%$ and the contribution of natural sources including open burning and biogenic source clearly observed. These results were considerably corresponding to the emission inventory investigated in this region.

Feasibility study of ground source heat pump system according to the local climate condition (지역 기후 특성에 따른 지열시스템의 도입경제성 차이에 관한 연구)

  • Nam, Yujin
    • KIEAE Journal
    • /
    • v.14 no.4
    • /
    • pp.127-131
    • /
    • 2014
  • The ground source heat pump (GSHP) system is a kind of the temperature differential energy system using relatively stable underground temperature as heat source of space heating and cooling. This system can achieve higher performance of system than it of conventional air source heat pump systems. However, its superiority of the system performance is different according to installation location or local climate, because the system performance depends on the underground condition which is decided by annual average air temperature. In this study, in order to estimate the feasibility of the ground source heat pump system according to the local climate, numerical simulation was conducted using the ground heat transfer model and the surface heat balance model. The case study was conducted in the condition of Seoul, Daejeon, and Busan, In the result, the heat exchange rate of Busan was 34.33 W/m as the largest in heating season and it of Seoul was 40.61 W/m as the largest in cooling.

Natural Convection in a Rectangular Enclosure with Heat Sources at the Bottom (밑면에 열원이 존재하는 밀폐공간에서의 자연대류)

  • Kwon, Y.I.;Kim, S.J.;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.3
    • /
    • pp.197-205
    • /
    • 1991
  • A numerical study has been performed to investigate two dimensional natural convection heat transfer in a rectangular enclosure with heat sources of constant temperature at the bottom. Calculations were made for various dimensionless heat source lengths, W/L=0.1-0.5, and positions of heat sources at $Gr=2.57{\times}10^6$, Pr=0.71 and Ks/Kf=28.98. For various positions of heat sources, the maximum local Nusselt numbers generally show X=0.81-0.85 at the bottom and X=0.23 at the top. For various dimensionless heat source lengths, the maximum local Nusselt numbers at the bottom show W/L=0.4 for one heat source, W/L=0.2 for two heat sources with fixed centers, W/L=0.5 for two heat sources with moved centers. Finally the maximum heat transfer at the bottom exhibits in condition of W/L=0.4 for two heat sources with moved centers.

  • PDF

Numerical Prediction of Smoke Concentration in a Compartment Fire by Using the Modified Volumetric Heat Source Model (수정된 체적열원모델을 이용한 실내 화재의 연기농도 예측)

  • Kim Sung-Chan;Lee Seong-Hyuk
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.4
    • /
    • pp.344-350
    • /
    • 2006
  • The present study investigates the characteristics of fire-driven heat flows and gas concentration in a compartment fire by using the modified VHS model (MVHS). The main idea of this model is to add some source terms for combustion products and oxygen consumption to the original VHS model for providing more accurate and useful information on gas concentration distributions as well as thermal fields. It is found that the present MVHS model shows fairly good agreement with the experimental data and the eddy breakup combustion model. The tilting angle of fire plume calculated by MVHS is larger than that of EBU model because the fire source of VHS is affected by ventilating flow less than EBU. However, this discrepancy is apparently reduced in the downstream region of fire source.

A Study on Pollution Levels and Source of Polychlorinated Biphenyl (PCB) in the Ambient Air of Korea and Japan (한국과 일본의 환경대기 중 폴리염화비페닐(PCB)의 농도수준 및 발생원 해석에 관한 연구)

  • Kim, Kyoung-Soo;Song, Byung-Joo;Kim, Jong-Guk;Kim, Kyeo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.2
    • /
    • pp.170-176
    • /
    • 2005
  • This study was conducted to investigate the level of PCBs and distribution of PCB congeners in the ambient air of Korea and Japan. The source of PCBs were also studied by a statistical method. The TEQ concentration of PCB in the ambient air of Korea and Japan were between 0.003 and $1.01\;pgTEQ/m^3$(mean value : $0.22\;pgTEQ/m^3$) and between 0.002 and $0.014\;pgTEQ/m^3$ (mean value: $0.007\;pgTEQ/m^3$), respectively. The ambient air of industrial area of Korea showed a fluctuation in PCB concentration than other sampling area. The isomer distribution patterns in the ambient air was more or less similar in all sampling places. In addition, highly chlorinated homologues ($7{\sim}10CB$) were detected in the only Korea industrial area. This observation suggests that there is a possibility of specific source of PCBs in the industrial area. The source identification of PCB in ambient air was performed using multivariate statistical analysis(principal component analysis). As a result, it is estimated that the Korean ambient air was more influenced by combustion process than the ambient air of Japan and also the effect of PCB commercial products was relatively a small.

A Regional Source-Receptor Analysis for Air Pollutants in Seoul Metropolitan Area (수도권지역에서의 권역간 대기오염물질 상호영향 연구)

  • Lee, Yong-Mi;Hong, Sung-Chul;Yoo, Chul;Kim, Jeong-Soo;Hong, Ji-Hyung;Park, Il-Su
    • Journal of Environmental Science International
    • /
    • v.19 no.5
    • /
    • pp.591-605
    • /
    • 2010
  • This study were to simulate major criteria air pollutants and estimate regional source-receptor relationship using air quality prediction model (TAPM ; The Air Pollution Model) in the Seoul Metropolitan area. Source-receptor relationship was estimated by contribution of each region to other regions and region itself through dividing the Seoul metropolitan area into five regions. According to administrative boundary, region I and region II were Seoul and Incheon in order. Gyeonggi was divided into three regions by directions like southern(region III), northern(IV) and eastern(V) area. Gridded emissions ($1km{\times}1km$) by Clean Air Pollicy Support System (CAPSS) of National Institute of Environmental Research (NIER) was prepared for TAPM simulation. The operational weather prediction system, Regional Data Assimilation and Prediction System (RDAPS) operated by the Korean Meteorology Administration (KMA) was used for the regional weather forecasting with 30km grid resolution. Modeling period was 5 continuous days for each season with non-precipitation. The results showed that region I was the most air-polluted area and it was 3~4 times more polluted region than other regions for $NO_2$, $SO_2$ and PM10. Contributions of $SO_2$ $NO_2$ and PM10 to region I, II and III were more than 50 percent for their own sources. However region IV and V were mostly affected by sources of region I, II and III. When emissions of all regions were assumed to reduce 10 and 20 percent separately, air pollution of each region was reduced linearly and the contributions of reduction scenario were similar to those of base case. As input emissions were reduced according to different ratio - region I 40 percent, region II and III 20 percent, region IV and V 10 percent, air pollutions of region I and III were decreased remarkably. The contributions to region I, II, III were also reduced for their own sources. However, region I, II and III affected more regions IV and V. Shortly, graded reduction of emission could be more effective to control air pollution in emission imbalanced area.