• 제목/요약/키워드: Air source

검색결과 2,261건 처리시간 0.036초

공기, 지열 및 복합 열원 열펌프의 중간기 에너지 소비량에 관한 연구 (Study on Energy Consumption of Air-source, Ground-source and Dual-source Heat Pump during Intermediate Season)

  • 조영욱;우태호;정광섭;김영일
    • 한국지열·수열에너지학회논문집
    • /
    • 제9권4호
    • /
    • pp.1-7
    • /
    • 2013
  • This study is to compare energy consumption of air-source, ground-source and dual-source heat pump systems during intermediate season using dynamic simulation. Ground-source heat pump has higher COP than that of air-source but requires additional power consumption of auxiliary equipment such as circulation pump. During intermediate season when the outdoor air temperature is favorable, total COP of air-source heat pump may be greater than that of ground-source when circulation pump power consumption is included. Dual-source heat pump which selects the more favorable heat source is compared with air-source only and ground-source only heat pumps for total power consumption. Results show that power consumption of dual-source heat pump is lower than that of ground-source only by 0.73%.

정수장 내 원수열원 및 공기열원 히트펌프의 냉난방 운전 특성 (Cooling and Heating Operation Characteristics of Raw-water Source Heat Pump and Air Source Heat Pump in Water Treatment Facility)

  • 오선희;윤린;조용
    • 설비공학논문집
    • /
    • 제25권7호
    • /
    • pp.386-391
    • /
    • 2013
  • The dynamic characteristics of both raw-water source and air source heat pump utilized in water treatment facilities were investigated by using TRNSYS simulator. The modeling of the raw water source heat pump was verified by the measured data at the Cheongju water treatment facility, and the modeling at the air source heat pump was verified by the data from the Siheung water treatment facility. The average heating and cooling COPs from the raw-water source heat pump were higher than those of the air source heat pump by 19% and 18%, respectively. The power consumptions of the air source heat pump for the cooling and the heating were higher than those of the raw water source heat pump by 28% and 26%, respectively.

공동주택의 공기열원 히트펌프 적용가능성 검토를 위한 운전성능 및 탄소배출량 평가 (Evaluation of Operational Performance and Carbon Emissions for the Feasibility of Air Source Heat Pump Application in Residential Buildings)

  • 김준석;김종수;전용석
    • 한국지열·수열에너지학회논문집
    • /
    • 제20권2호
    • /
    • pp.24-36
    • /
    • 2024
  • This study analyzed the feasibility of the air source heat pump in residential buildings based on operational performance and carbon emissions. The operational performance and carbon emissions were compared between a gas boiler and an air source heat pump by calculating the annual heating and hot water load based on the 21A and 36A models for actual residential buildings. For the operational performance of the air source heat pump, the lowest (2.3) and highest COP (5.9) were attained during the winter and summer seasons, respectively. The carbon emissions depend on the amount of energy consumed during operations. An air source heat pump consumed 65.10% and 65.4% less energy per year in the 21A and 36A models, respectively compared to the existing gas boiler. Consequently, for air source heat pump carbon emissions were also reduced by 13.3% and 15.1% per year for the 21A and 36A models, respectively. It shows the effectiveness of applying an air source heat pump compared to an existing gas boiler.

대구시 대기오염물질 배출량 산정에 관한 연구 (Emission Estimation of Air Pollutants in Daegu)

  • 박명희;김해동;홍정혜
    • 한국환경과학회지
    • /
    • 제12권1호
    • /
    • pp.23-34
    • /
    • 2003
  • Urban air quality is usually worse than that of rural counterpart. The contrasting atmospheric properties seem to be direct result of different urban-rural air pollutant emission. Hence, the emission estimation of air pollutants plays an important role to the atmospheric environmental management. The main purpose of this study is to find out the temporal and spatial distribution of air pollutant emission in Daegu area. For the study, the Daegu statistical yearbook and data of waste facilities and the report on traffic survey issued by Daegu metropolitan city and the statistical yearbook on the road capacity issued by the ministry of construction and transportation are used. Each item for the emission estimation is $SO_2$, CO, HC, $NO_x$, PM-10 from point, line and area source. The result were as follow; (1) The air pollutants with the highest amount of emission from the emission source is CO followed by $NO_x$, $SO_2$, PM-10, HC in descending order of magnitude. (2) The annually totaled air pollutant emission consists of 81%(73,185 ton/year) of line, 11%(9,589% ton/year) of area and 8%(7,445 ton/year) of point source in Daegu. Air polluant emission was mainly due to line sources. (3) High-emission of the air pollutants of line source appeared ariond Bukgu, Dalseonggun, Dongu and Seogu ; the areas with highway networks.

에어컨 실내기에서 발생하는 충격 소음원의 위치 추정 (Source localization of impact noise on an indoor unit of air-conditioner)

  • 최영철;김양한;이종구;김구영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.324-329
    • /
    • 2003
  • An air-conditioner has various noise sources such as cooling fan noise, pumping noise, flow noise and impact noise. Among these, impact noise is the most unpleasant source. This is because the noise is produced in indoor unit of air-conditioner. To control the noise source effectively, first we must identify the noise sources. When we identify impact noise source, the measurement have to be carried out simultaneously. So we use beamforming method that requires less measurement points than intensity method and acoustic holography. The objective of this paper is to estimate the location of impact source. This objective can be achieved by using minimum variance cepstrum that is able to detect impulse embedded in noise. In this study, modified beamforming method based on cepstrum domain is proposed. Then this method applied to air-conditioner noise sources which produce impact noise.

  • PDF

질산화가스와 아황산가스의 비를 이용한 대기오염 기여도 분석 (Analysis of Air Pollutant Sources Contribution by using Ratio of Sulfur Dioxide Gas to Nitrogen Oxides Gas)

  • Wan, Cha-Ju;Cheol, Choe-Byeong;Cheon, Choe-Jae
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2003년도 춘계학술대회 논문집
    • /
    • pp.261-264
    • /
    • 2003
  • We try to distribute air pollution sources at target area. The complex method is used to distribute air pollution sources. Most of people, However, want to simple indicator as standard for express air pollution source. In many area, air pollution is caused by different types of sources. The general type is point source, such as tall stack of power plants and oil refineries stacks. A second type is areal source, such as local industry and transportation. In this aspect, the ratio of sulfur dioxide to nitrogen oxides (RSN =SO$_2$/NOx)is an indicator of air pollution source. the role of this ratio is to show the characteristics at target area of the relationship the point and the areal source. (omitted)

  • PDF

PMF모델을 이용한 대기 중 PM-10 오염원의 정량적 기여도 추정 (Estimation of Quantitative Source Contribution of Ambient PM-10 Using the PMF Model)

  • 황인조;김동술
    • 한국대기환경학회지
    • /
    • 제19권6호
    • /
    • pp.719-731
    • /
    • 2003
  • In order to maintain and manage ambient air quality, it is necessary to identify sources and to apportion its sources for ambient particulate matters. The receptor methods were one of the statistical methods to achieve reasonable air pollution strategies. Also, receptor methods, a field of chemometrics, is based on manifold applied statistics and is a statistical methodology that analyzes the physicochemical properties of gaseous and particulate pollutant on various atmospheric receptors, identifies the sources of air pollutants, and quantifies the apportionment of the sources to the receptors. The objective of this study was 1) after obtaining results from the PMF modeling, the existing sources of air at the study area were qualitatively identified and the contributions of each source were quantitatively estimated as well. 2) finally efficient air pollution management and control strategies of each source were suggested. The PMF model was intensively applied to estimate the quantitative contribution of air pollution sources based on the chemical information (128 samples and 25 chemical species). Through a case study of the PMF modeling for the PM-10 aerosols, the total of 11 factors were determined. The multiple linear regression analysis between the observed PM-10 mass concentration and the estimated G matrix had been performed following the FPEAK test. Finally the regression analysis provided quantitative source contributions (scaled G matrix) and source profiles (scaled F matrix). The results of the PMF modeling showed that the sources were apportioned by secondary aerosol related source 28.8 %, soil related source 16.8%, waste incineration source 11.5%, field burning source 11.0%, fossil fuel combustion source 10%, industry related source 8.3%, motor vehicle source 7.9%, oil/coal combustion source 4.4%, non-ferrous metal source 0.3%. and aged sea- salt source 0.2%, respectively.

집단 에너지 시설에 의한 주변 대기질 영향 (The influence on air quality of the surroundings by the facility of the district heating)

  • 연익준;주소영;이민희;손종렬;김광렬
    • 환경위생공학
    • /
    • 제17권2호
    • /
    • pp.18-25
    • /
    • 2002
  • The comparison of the air quality with the evaluation of the environmental assessment before and after operations of the heat source and of the flue-gas desulfurization facilities were studied. First of all, several sites were selected for the representative sample points, and then they were examined air quality of the surroundings. The results were that TSP(total suspended particulate) analysis after an operation of the heat source facility was $74~81{\mu}g/m^3$, PM-10 was $31~94{\mu}g/m^3$, and $SO_2$concentration was 0.002~0.009ppm, respectively. As the result of examination to the concentrations of diffused pollutants, there was no relations between TSP concentration of sample points and the effect of air quality according to the heating source. When we compared the neighbored area of the heating source with the other area, the concentration of air pollutants after an operation of the facility of the heating source was similar to the heating source, the neighbored area, and the other area. So we concluded that there was no the effect of the air pollution by producted pollutants from the heating source.

선박배출 오염물질의 영향을 고려한 부산지역 대기질 모델의 개발 (The Development of Air Quality Model Considering Shipping Source in Pusan Region)

  • 이화운;김유근;원경미
    • 한국환경과학회지
    • /
    • 제8권1호
    • /
    • pp.135-144
    • /
    • 1999
  • Air quality modeling about coastal urban region such as Pusan shoud be consider shipping source emmited from ships anchoraging and running. It has been proved at our previous studies that the ratios of air pollutants emission amount in coastal area to inland are 12.2% for NO$_2$ and 11.7% for $SO_2$ and the air qualify of coastal urban area consierably counts on ships. Also the dispersion pattern of the all pollutants followed local circulation system in this region. Therefore this study has been developed air quality model which can describe the formation, transport, transformation and deposition processes of air pollutants considering shipping source. Currently, restriction for emission amount of ships does not exist, so our study will be useful to set the omission standard and for devising air quality policy in coastal urban region.

  • PDF

2열 외부가압 공기 저어널 베어링에서 급기구 위치에 따른 부하지지 특성에 관한 연구 (A Study on the Loading Capacity According to the Source Positions in Externally Pressurized Air Journal Bearing with Two Row Sources)

  • 이종열;성승학;이득우
    • Tribology and Lubricants
    • /
    • 제17권5호
    • /
    • pp.365-372
    • /
    • 2001
  • This paper has been presented the hydrodynamic effect by the journal speed, eccentricity and source positions in order to overcome the defects of air bearing such as low stiffness and damping coefficient. Choosing the two row source position of air bearing is different from existed investigations in the side of pressure distribution of air film because of the high speed of journal and the wedge effects by the eccentricity. These optimal chooses of the two row source positions enable us to improve the performance of the film reaction force and loading force as making the high speed spindle. In this paper, The pressure behavior in theory of air film according to the eccentricity of journal and the source positions analyzed. The results of investigated characteristics may be applied to precision devices like ultra-precision grinding machine and ultra high speed milling.