• Title/Summary/Keyword: Air sampling

Search Result 713, Processing Time 0.028 seconds

Quality Control(QC) Analysis of Ambient VOCs in Canisters Using GC/MSD Method (Canister와 GC/MSD를 이용한 대기 중 VOCs 분석시스템의 정도관리(QC))

  • Jeon, Jun-Min;Hur, Dang;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.527-538
    • /
    • 2002
  • In this study, the performance of sampling and of analytical methodology was examined against a number of selected volatile organic compounds (VOCs) in the ambient air. The canister-based sampling method for VOCs has been a viable and widely used approach that is based on research and evaluation performed over the past several years. VOCs were determined using canisters by GCMSD analysis. A total of target analyses in this study included approximately 30 VOCs designated in TO-l4A categories including BTEX. The methodology for QC(quality control) was intensively investigated with a wide range of performance criteria such as; (1) cleanliness of canisters, (2) reproducibility of diluter, (3) instrumental detection limits of preconcentrator and GCMSD, and (4) precision and accuracy of GCMSD. For most of the compounds tested, precision was less than $\pm$5%, IDL was 0.2 ppbv, accuracy was $\pm$5%, respectively. This study demonstrated that the combination of canister sampling and GC/MSD analysis could be reliably applied to the measurements of BTEX in ppbv levels that are typically observed in/outdoor air environment.

Gas-Particle Partitioning of PCBs in Ambient Air, Yokohama Japan (일본 요코하마 대기 중 PCBs의 가스-입자 분배)

  • Kim Kyoung-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.3
    • /
    • pp.285-293
    • /
    • 2005
  • This study was aimed at estimation of gas-particle partitioning of polychlorinated biphenyls (PCBs) in ambient air. The samples were collected at urban site in Japan from March 2002 to January 2003. The concentration of total PCBs (from 4 CB to 10 CB) and TEQ (Toxic equivalent) ranged from 62 to $247\;pg/m^3$ and from 2 to $14\;fgTEQ/m^3 $, respectively. The average contribution $(\%)$ of gas phase to total PCBs concentration was above $80\%$, which suggests that in the atmosphere PCBs predominantly existed in the gas phase. The weak correlations between total PCBs concentration and temperature was found. However this result was due to a typhoon during summer and raining during sampling period. The gas-particle partition coefficient (Kp) was obtained as a function of temperature. The partition ratio of gaseous and particulate phase PCBs can be estimated for an arbitrary temperature. The plot of gas/particle partition coefficient (log Kp) vs. sub-cooled liquid vapor pressure $(log\;P_L)$ had reasonable correlations for individual samples but the slope varied among the samples (coefficients of determination for log Kp versus log $P_L$ plot were> 0.76 $(p<0.0001)$, except for 3 samples). As a result, the variations in the slope among the sampling period may be due to change of temperature, raining during sampling period and wind in this study.

지하수 조사에서 환경추적자로서의 $SF_6$의 적용

  • ;Niel Plummer;Eurybiades Busenberg
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.73-76
    • /
    • 2003
  • SF$_{6}$ (Sulfur Hexafluoride) is a gaseous compound whose use is being greatly increased recently. The compound has a negligible background concentration from natural sources and is stable in most of groundwater environments. Therefore, SF$_{6}$ has potential for a dating tool for young groundwater. It has many advantages over chlorofluorocarbons (CFCs) for groundwater investigation that sampling procedure is much simpler than CFCs and its growth is continued up to at least near future in the atmosphere. However, solubility of SF$^{6}$ is so low that excess air causes large uncertainties in recharge date of groundwater. To compensate the limitation, $N_2$/Ar method can be employed to estimate excess air content. A groundwater study is currently carrying out in Jeju Island using SF$_{6}$ as an environmental tracer, Well waters and spring waters were sampled for SF$_{6}$ and $N_2$/Ar. To establish SF$_{6}$ input history in the study area, air sampling is being conducted in the area near the center of the island on a monthly and weekly basis. Based on the present data, the level of SF$_{6}$ concentration in the atmosphere of the Island is corresponding to the trend of the Northern Hemisphere.

  • PDF

Associations between Air Pollution and Asthma-related Hospital Admissions in Children in Seoul, Korea: A Case-crossover Study (환자교차 설계 방법을 적용한 소아천식 입원에 대한 도시 대기오염의 급성영향평가)

  • Lee, Jong-Tae
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.1
    • /
    • pp.47-53
    • /
    • 2003
  • Objectives : I used a case-crossover design to investigate the association between air pollution, and hospital admissions for asthmatic children under the age of 15 years in Seoul, Korea Methods : I estimated the changes in the levels of hospitalization risk from theinterquartile (IQR) increase in each pollutant concentrations, using conditional logistic regression analyses, with controls for weather information. Results : Using bidirectional control sampling, the results from a conditional logistic regression model, with controls for weather conditions, showed the estimated relative risk of hospitalization for asthma among children to be 1.04 (95% confidence interval (CI), 1.01-1.08) for particulate matter with an aerodynamic diameter less than or equal to 10m (IQR=40.4ug/m3); 1.05 (95% CI, 1.00- 1.09) for nitrogen dioxide (IQR=14.6ppb): 1.02 (95% CI,0.97-1.06) for sulfur dioxide (IQR=4.4ppb): 1.03 (95% CI, 0.99-1.08) for ozone (IQR=21.7ppb): and 1.03 (95% CI, 0.99-1.08) for carbon monoxide f10R=1.0ppm). Conclusions : This empirical analysis indicates the bidirectional control sampling methods, by design, would successfully control the confounding factors due to the long-term time trends of air pollution. These findings also support the hypothesis that air pollution at levels below the current ambient air quality standards of Korea is harmful to sensitive subjects, such as asthmatic children.

Aerosol Filtration/Sampling Device Based on Irrigated Rotating Wires

  • M. J. Shaw;M. R. Kuhlman;;J. A. Gieseke
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.265-267
    • /
    • 2000
  • The objective of this study is to analyze, design and evaluate a new gas cleanup or sampling system that will remove erosive, corrosive, and fouling contaminants present in an effluent stream as either solid or liquid particles providing a clean gas stream. The gas clean-up or sampling system considered in this study is an irrigated, rotating element device. The device consists of a central disk-like hub from which emanate radially wires or cylindrical elements. (omitted)

  • PDF

Comparison of VOCs' stabilities in sampling bags (Sampling bag에서 저농도 VOC의 안정성 비교)

  • 김정우;허귀석;유연미;이재환;이진홍
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.346-347
    • /
    • 2001
  • Sampling bag은 비교적 저렴한 가격으로 쉽게 구할 수 있어 VOC 및 악취물질을 분석할 때 널리 사용되고 있다. 그러나 저농도의 분석에서는 흡착으로 인한 농도 변화가 일어날 수 있어 분석결과에 큰 영향을 줄 수 있다고 알려져 있다. 그러나, bag내부에서의 안정도에 대한 충분한 조사가 이루어져 있지 않아 VOC 화합물이 얼마나 bag에서 안정성의 문제가 있는지에 대한 정량적인 이해가 매우 부족한 실정이다. (중략)

  • PDF

Comparison of storage stability of polar VOCs in sampling bag (Sampling bag에서 극미량 극성 VOCs의 안정성 비교)

  • 허귀석;김정우
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.04a
    • /
    • pp.231-232
    • /
    • 2002
  • 대기중에 존재하는 미량의 극성 유기화합물들은 비극성 유기화합물 보다는 반응성이 크고 불안정하므로 이를 채취하여 분석하는 과정이 매우 어려운 실정이다. 일반적으로 sampling에 자주 사용되는 stainless steel로 특수 내면처리 시킨 canister를 이용하였으나 이 방법에 의한 시료 채취방법은 고가의 비용이 소요되며, 반응성이 큰 VOC의 경우에는 성분에 따라 안정도가 낮은 경우도 많다. 그러므로 본 연구에서는 대기 시료를 bag 이나 캐니스터와 같은 용기로서 채취하여 측정할 경우 극성 VOC 성분이 얼마나 안정하게 유지될수 있는지를 조사하고저 하였다. (중략)

  • PDF

Evaluation of an electrical impactor with porous metal substrate (다공성 금속판을 이용한 전기적 임팩터의 평가)

  • Jeong Jeong-Seon;Gwon Sun-Park;Lee Gyu-Won
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.276-277
    • /
    • 2002
  • One of drawbacks of the inertial impactor measurement is the required long sampling time (Keskinen et al., 1992). In a gravimetric method, an impaction substrate must be weighed and placed on the corresponding collection plate before being assembled. After sampling, the inertial impactor is disassembled and the collection plate is weighted again. The sampling time depends on the sampled particle mass because the collected particle mass must be sufficiently high to be measured by a sensitive microbalance. (omitted)

  • PDF

A study on the variation of orifice diameter in a straight pipe giving dqual-sampling rate (직선배관에서 균일한 공기 흡입을 하는 오리피스 직경변화에 대한 연구)

  • Kim, Jin-Guk
    • Fire Protection Technology
    • /
    • s.24
    • /
    • pp.17-22
    • /
    • 1998
  • The objective of this paper is to investigate the variation of orifice diameter in a straight pipe which can give equal-sampling rate. This can be utilized for designing orifice in air-sampling smoke detector. The elements which should be considered for designing orifices was presented and the calculation procedure was also given in this paper. The effects of pipe length, the number of orifices, fan pressure was decribed.

  • PDF