• Title/Summary/Keyword: Air pollution index

Search Result 136, Processing Time 0.024 seconds

Determination of Correlation between Cetane Number, Derived Cetane Number and Cetane Index for Diesel Fuel (경유연료의 세탄가, 유도세탄가 및 세탄지수의 상관관계 분석)

  • Jeon, Hwayeon;Kim, Ji Yeon;Kim, Shin;Yim, Eui Soon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.1134-1144
    • /
    • 2018
  • Cetane Number is one of the quality standard for diesel, which assesses the compatibility of ignition quality of diesel compression in diesel engines. Cetane number must be upper 52 to keep the recent diesel quality standards. It is known that if cetane number is high, there will be shorter ignition delay periods than being lower. On the other hands, if cetane number is too high that exceeds the quality standard, there will increase the air pollution and decrease of the fuel efficiency because incomplete combustion. In South Korea, various methods are being used to measure the cetane number such as cetane number that used CFR engine, cetane index from calculate density and distillation temperature and derived cetane number to make up for CFR engine that ignition delay in high temperature is implemented. In this study will be conducted by collecting the diesel from the major oil companies, and try to analyze the correlation between the different methods of cetane number with various factors. At the results of this study, it was shown that the cetane index is high then cetane engine and derived cetane number. therefore it will be necessary to additional research for out of cetane number quality standards.

Enhancement of Ozone and Carbon Monoxide Associated with Upper Cut-off Low during Springtime in East Asia

  • Moon, Yun-Seob;Drummond, James R.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.5
    • /
    • pp.475-489
    • /
    • 2010
  • In order to verify the enhancement of ozone and carbon monoxide (CO) during springtime in East Asia, we investigated weather conditions and data from remote sensors, air quality models, and air quality monitors. These include the geopotential height archived from the final (FNL) meteorological field, the potential vorticity and the wind velocity simulated by the Meteorological Mesoscale Model 5 (MM5), the back trajectory estimated by the Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model, the total column amount of ozone and the aerosol index retrieved from the Total Ozone Mapping Spectrometer (TOMS), the total column density of CO retrieved from the Measurement of Pollution in the Troposphere (MOPITT), and the concentration of ozone and CO simulated by the Model for Ozone and Related Chemical Tracers (MOZART). In particular, the total column density of CO, which mightoriginate from the combustion of fossil fuels and the burning of biomass in China, increased in East Asia during spring 2000. In addition, the enhancement of total column amounts of ozone and CO appeared to be associated with both the upper cut-off low near 500 hPa and the frontogenesis of a surface cyclone during a weak Asian dust event. At the same time, high concentrations of ozone and CO on the Earth's surface were shown at the Seoul air quality monitoring site, located at the surface frontogenesis in Korea. It was clear that the ozone was invaded by the downward stretched vortex anomalies, which included the ozone-rich airflow, during movement and development of the cut-off low, and then there was the catalytic photochemical reaction of ozone precursors on the Earth's surface during the day. In addition, air pollutants such as CO and aerosol were tracked along both the cyclone vortex and the strong westerly as shown at the back trajectory in Seoul and Busan, respectively. Consequently, the maxima of ozone and CO between the two areas showed up differently because of the time lag between those gases, including their catalytic photochemical reactions together with the invasion from the upper troposphere, as well as the path of their transport from China during the weak Asian dust event.

Indicators for the Quantitative Assessment of Tree Vigor Condition and Its Theoretical Implications : A Case Study of Japanese Flowering-cherry Trees in Urban Park (도시공원에 식재된 왕벚나무 수종을 중심으로 한 수목활력도의 정량평가지표 개발 및 이론적 고찰에 관한 연구)

  • Song, Youngkeun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.17 no.4
    • /
    • pp.57-67
    • /
    • 2014
  • The vigor condition of trees is an important indicator for the management of urban forested area. But difficulties in how to assess the tree vigor condition still remain. Previous efforts were limited in the 1) measurement of single indicator rather than using multiple indices, 2) purpose-oriented measurement such as for air-pollution effect or specific pathological symptom, and 3) ordinal-scale evaluations by field crews 4) despite human errors based on his/her experiences or prior knowledge. Therefore, this study attempted to develop a quantitative and objective methodology for assessing tree vigor condition, by measuring multiple modules and building the profile inventory. Furthermore, the possibility and limitations were discussed in terms of schematic frames describing tree vigor condition. The vigor condition of 56 flowering cherry plants in urban park were assessed by in-situ measurements of following eight items; growth of crown(Gc), growth of shoots, individual tree volume(Vol), plant area index, woody area index, leaf area index, leaf chlorophyll content(Lc) and leaf water content(Lw). For validation, these measurements were compared with the ranks of holistic tree vigor condition, which were visually assessed using a 4-point grading scale based on the expert's knowledge. As a result, the measures of each evaluation item successfully highlighted a variety of aspects in tree vigor condition, including the states of both photosynthetic and non-photosynthetic parts. The variation in the results depending on evaluated parts was shown within an individual tree, even though the broad agreement among the results was found. The result of correlation analysis between the tested measurements and 4-point visual assessment, demonstrated that the state of water-stressed foliage of the season (Lw) or the development of plant materials since sapling phase (Vol) could be better viewed from the outer appearance of trees than other symptoms. But only based on the visual assessment, it may be difficult to detect the quality of photosynthesis (Lc) or the recent trend in growth of trees (Gc). To make this methodology simplified for the broad-scale application, the tested eight measurements could be integrated into two components by principal component analysis, which was labelled with 'the amount of plant materials' and 'vigor trend', respectively. In addition, the use of these quantitative and multi-scale indicators underlies the importance of assessing various aspects of tree vigor condition, taking into account the response(s) on different time and spatial scale of pressure(s) shown in each evaluated module. Future study should be advanced for various species at diverse developing stages and environment, and the application to wide areas at a periodic manner.

Development and its Application for Energy Efficiency Operation Indicator and Energy Efficiency Design Index Monitoring System on the Ship (선박의 에너지효율운전지표와 에너지효율설계지수의 모니터링 시스템 개발과 그 응용)

  • Lee, Don-Chool;Kim, Eoue-Sek;Joo, Ki-Se;Nam, Jeong-Gil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.500-507
    • /
    • 2010
  • Regard to the global warming, the shipping industries are progressed the dedicated endeavor to reduce greenhouse gas. As the study results of 2009 GHG study team, the $CO_2$ emission of shipping industries exceeded slightly 1.0 billion ton during one year(2007) and it is 3.3% of total $CO_2$ amount exhausted from all industries. This paper are introduced the energy efficiency design index / operation indicator monitoring system(EDiMS) which matched with EVAMOS software released by the dynamics laboratory of Mokpo maritime university. EDiMS can continuously be monitored amounts of $CO_2$, NOx, SOx, and PM emitted from ship and it can be applied as the useful tool of the inventory work of air pollution and the ship energy management plan for the mitigation or reduction of ship emission.

Recent Progress in Air Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2007 (설비공학 분야의 최근 연구 동향 : 2007년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Shin, Dong-Sin;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.844-861
    • /
    • 2008
  • The papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during the year of 2007 have been reviewed. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro nano fluid, micropump and fuel cell. Traditional CFD was still popular and widely used in research and development. Studies about fans and pumps were performed in the field of fluid machinery. Characteristics of flow and fin shape optimization are studied in the field of piping system. (2) The research works on heat transfer have been reviewed in the field of heat transfer characteristics, heat exchangers, and desiccant cooling systems. The research on heat transfer characteristics includes thermal transport in pulse tubes, high temperature superconductors, ground heat exchangers, fuel cell stacks and ice slurry systems. For the heat 'exchangers, the research on pin-tube heat exchanger, plate heat exchanger, condensers and gas coolers has been cordially implemented. The research works on heat transfer augmenting tubes have been also reported. For the desiccant cooling systems, the studies on the design and operating conditions for desiccant rotors as well as performance index are noticeable. (3) In the field of refrigeration, many papers were presented on the air conditioning system using CO2 as a refrigerant. The issues on the two-stage compression, the oil selection, and the appropriate oil charge were treated. The subjects of alternative refrigerants were also studied steadily. Hydrocarbons, DME and their mixtures were considered and various heat transfer correlations were proposed. (4) Research papers have been reviewed in the field of building facilities by grouping into the researches on heat and cold sources, air conditioning and air cleaning, ventilation and fire research including tunnel ventilation, flow control of piping system, and sound research with drain system. Main focuses have been addressed to the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies were mostly focused on analyzing the indoor environment in various spaces like cars, old tombs, machine rooms, and etc. in an architectural environmental field. Moreover, subjects of various fields such as the evaluation of noise, thermal environment, indoor air quality and development of energy analysis program were researched by various methods of survey, simulation, and field experiment.

Effects of Ambient Particulate Matter($PM_{10}$) on Peak Expiratory Flow and Respiratory Symptoms in Subjects with Bronchial Asthma During Yellow Sand Period (황사기간 중 천식 환자에서 대기 중 미세먼지($PM_{10}$)가 최대호기 유속과 호흡기 증상에 미치는 영향)

  • Park, Jeong Woong;Lim, Young Hee;Kyung, Ssun Young;An, Chang Hyeok;Lee, Sang Pyo;Jeong, Seong Hwan;Ju, Young-Su
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.6
    • /
    • pp.570-578
    • /
    • 2003
  • Background : Ambient particles during Asian dust events are usually sized less than $10{\mu}m$, known to be associated with the adverse effects on the general populations. But, there has been no considerable evidence linking these particles to the adverse effects on airways. The objectives of this study was to investigate the possible adverse effects of Asian dust events on respiratory function and symptoms in subjects with bronchial asthma. Patients and Methods : From march to June 2002, Asthmatic patients who were diagnosed with bronchial challenge test or bronchodilator response were enrolled. We divided them into three groups; mild, moderate, and severe, according to the severity. Subjects with other organ insufficiency such as heart, kidney, liver, and malignancy were excluded. All patients completed twice daily diaries and recorded peak flow rate, respiratory symptom, and daily activity. Daily and hourly mean pollutant levels of particulate matter < $10{\mu}m$ in diameter($PM_{10}$), nitrogen dioxide($NO_2$), sulphur dioxide($SO_2$), ozone($O_3$) and carbon monoxide(CO) were measured at the 10 different monitoring sites. Results : Dust events occured 14 times during the study period. Daily averages of 4 air pollutant were measured with an increased level of $PM_{10}$, decreased level of $NO_2$ and $SO_2$, and no change in CO during dust days compared to those during control days. An increase in $PM_{10}$ concentration was associated with an increase of subjects with PEF variability of >20% (p<0.05), night time symptom(p<0.05), and a decrease in mean PEF (p<0.05), which were calculated by the longitudinal data analysis. Otherwise, there was no association between $PM_{10}$ level and bronchodialtor inhaler, and daytime respiratory symptoms. Conclusion : This study shows evidence that ambient air pollution, especially $PM_{10}$, during Asian dust events, could be one of the many aggravating factors at least in patients with airway diseases. This data can be used as a primary source to set up a new policy on air environmental control and to evaluate the safety of air pollution index. We also expect that this research will help identify precise components of dust, which are more linked to the adverse effects.

Selection on Representative Compound According to the Characteristics of the Change of VOC Concentration Indoor from the Newly Built House in Japan (일본 신축주택의 실내 VOC의 실태와 농도추이 특성에 의한 유형별 대표물질선정)

  • Yoo, Bok-Hee;Tanaka, Tatsuaki;Yoon, Chung-Sook
    • KIEAE Journal
    • /
    • v.1 no.1
    • /
    • pp.35-43
    • /
    • 2001
  • The VOC, which were detected from the newly built house, exist as a certain number of types according to the characteristics of the change of VOC concentration indoors. In this paper, we aim to divide the VOC into types so that those with similar characteristics of the transition of their concentration are in the same group and select the representative compound according to each classified type, and to verify these processes statistically in order to verify and propose new method creating the representing index of the VOC concentration in indoor which is used in evaluation of the degree of air pollution. As a result, the characteristic of the change of VOC concentration in the indoor can be divided into three types. Type1; the group in which the concentration is relatively high right after the completion of the house, and then decreases rapidly. Type2; the group in which the concentration is relatively low right after the completion of the house, and then although it shows the tendency of increasing and decreasing repeatedly, it decreases overall. Type3 is the group, which show only one peak at a certain time during the measuring period. As the method like this was verified to have the statistical significance, the Ethylbenzene was selected as the representative compound of type1, and Styrene was selected as that of type2. Moreover, if considering transition of the VOC from the point of similarity, the research method of making the classification and the selection of the representative compound in this study are said to be significant method.

  • PDF

Development of the Sentiment Indicators of Housing Welfare (주거복지지표 개발에 관한 연구 II - 수요자 측면의 주거복지체감지표와 지수를 중심으로 -)

  • Jee, Eun-Young;Eun, Nan-Soon;Hong, Hyung-Ock
    • Journal of the Korean housing association
    • /
    • v.19 no.5
    • /
    • pp.85-92
    • /
    • 2008
  • The aim of this research is to develop the sentiment indicators of housing welfare for evaluating housing welfare policies conducted by the Korean government. The methods of this research are used by analysis of related documents, FGI (Focus Group Interview), and survey. The survey was made by experts and consumers. To analyze the survey, this research also uses confirmatory factor analysis by SPSS (Statistical Package for the Social Science) program, AHP (Analytical Hierarchy Process) by Expert Choice program, frequency, average, percentages, Factor analysis etc. As a result of this research, selected housing welfare indicators are settled as follows: In the housing welfare aspect, 11 indicators in the department of 'Housing Satisfaction' and 11 indicators in the department of 'Community Satisfaction' (22 in total) are suggested. The indicators are 1) Water Supply and Distribution Equipment 2) Heating equipment 3) the size of the exclusive residential area 4) the number of rooms 5) Ventilation and Lighting 6) Sound Insulation (Indoor Noise) 7) Air Pollution/Odor 8) House Deposit 9) Rent Paid 10) Maintenance (Dwelling) Cost 11) The length of Occupation 12) Proximity to Welfare Facilities 13) Educational Environment 14) Convenience of Facilities (shops, hospitals etc.) 15) Convenience of Transportation and Commuting 16) Distance from Workplace 17) Landscape and Green Space (Tree, Flowers, Grass etc.) 18) Vandalism (Destruction Behavior, graffiti etc.) 19) Privacy 20) Noise in Public Places (Drinking, Loudly Talking etc.) 21) Safety from Crime 22) Safety from a Disaster. As of 2007, the housing welfare sentiment index is measured by the survey of 1,000 inhabitants in the public housing, which shows 3.51.

A Review Study on Ozone Phytotoxicity Metrics for Setting Critical Levels in Asia

  • Agathokleous, Evgenios;Kitao, Mitsutoshi;Kinose, Yoshiyuki
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.1
    • /
    • pp.1-16
    • /
    • 2018
  • Ground-level ozone ($O_3$) can be a menace for vegetation, especially in Asia where $O_3$ levels have been dramatically increased over the past decades. To ensure food security and maintain forest ecosystem services, such as nutrient cycling, carbon sequestration and functional diversity of soil biota, in the over-populated Asia, environmental standards are needed. To set proper standards, dose-response relationships should be established from which critical levels are derived. The predictor of the response in the dose-response relationship is an $O_3$ metric that indicates the dose level to which the plant has been exposed. This study aimed to review the relevant scientific literature and summarize the $O_3$ metrics used worldwide to provide insights for Asia. A variety of $O_3$ metrics have been used, for which we discuss their strengths and weaknesses. The most widely used metrics are based only on $O_3$ levels. Such metrics have been adopted by several regulatory agencies in the global. However, they are biologically irrelevant because they ignore the plant physiological capacity. Adopting AOT40 ($O_3$ mixing ratios Accumulated Over the Threshold of $40nmol\;mol^{-1}$) as the default index for setting critical levels in Asia would be a poor policy with severe consequences at national and Pan-Asian level. Asian studies should focus on flux-based $O_3$ metrics to provide relevant bases for developing proper standards. However, given the technical requirements in calculating flux-based $O_3$ metrics, which can be an important limitation in developing countries, no-threshold cumulative exposure indices like AOT0 should always accompany flux-based indices.

The Economic Analysis of A Solid Refuse Fuel (SRF) Project in the Urban Area (가연성 폐기물 고형연료(SRF) 사업의 경제성 분석)

  • Jang, EunMi;Cho, Yongsung
    • Journal of Climate Change Research
    • /
    • v.4 no.3
    • /
    • pp.245-254
    • /
    • 2013
  • Korea government promote renewable energy as the core of their energy matrix to break the dependence and reduce greenhouse effects. This study analyzes the economic assessment of Solid Refuse Fuel project in urban area, considering the marginal external costs of air pollution in this area. Assessment index defined as costs (i.e., construction cost, operation cost) and benefit (margin, external cost) data which is located in Sudokwon landfill site. The result indicates that cost-benefit analysis of SRF is calculated as 1.0. In addition, SRF project is very sensitive about electric power selling price, operating cost and labor cost according to inflation rates. This study shows that the sustainability of SRF project is required the government financial support like investment funds as well as policy support. Variability analysis of SRF economic assessment due to renewable energy can be used for making policies in various fields such as waste and public energy field.